| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC L1 quoted rates are overall reasonable,hence Accepted | |
| 2 | L2₹36.1 L+₹5.6 L (18.4%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹37.2 L+₹6.7 L (22.0%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹40.3 L+₹9.8 L (32.0%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-AOC REJECTED |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Dec 2019, 6:00 pmClosed
GE (NW) BHNADUP
GE (NW) BHNADUP , MUMBAI
REPAIR/REPLACEMENT OF LT PANELS/CABLES AND OTHER MISC AND ALLIED EXTERNAL ELECTRIFICATION ITEMS AT NCHC POWAI AND ULHASNAGAR UNDER GE(NW) BHANDUP
2019_MES_300199_1
8787/B
Open Tender
Civil Works
Item Rate
274 days
POWAI
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat b(i)
9 documents required · 9 mandatory
₹500
GE (NW) BHNADUP
₹70,000
Yes
13 Mar 2020
22 Nov 2019
27 Dec 2019
22 Nov 2019
24 Dec 2019
5 Dec 2019
22 Nov 2019 - 27 Nov 2019
Amount
Dismanting/Disconnect of unserviceable LT panel board and shifting to new location, refixing, testing complete including all MCCBs under ground cables with necessary copper control wiring, cable gland lugs etc and remove rusted paint and applying one coat of synthetic enamel paint all as specified and directed.
M & L for broken stone or boulders hardcore og gauge n exc. 63 mm, deposited, spread and levelled in layers n exe. 15 cm thick, watered and rammed to a true surface for surrounding of trasformers/VCBs complete all as specified and directed
S&F in repairs MCCB 100 Amps 3 Pole, fixed type, 415 Volts, 25 KA complete all as specified and directed.
S&F in repairs MCCB 100 Amps 4 Pole, fixed type, 415 Volts, 25 KA including suitable sheet metal enclouser complete all as specified and directed.
Repairs and overhauling of Air Circuit Breaker (ACB) 3/4 pole, 415 Volt, upto 1200 Amp with thermal magnetic release by replacement of worn out parts and cleaning the complete ACB and testing the same after repair for smooth functioning etc, complete all as specified and directed.
Supply and fix in repair power capacitor bank 10KVAR, 3Ph, 415V all as specified and directed.
Supply and fix in repair power capacitor bank 15KVAR, 3Ph, 415V all as specified and directed.
Supply and fix in repair power capacitor bank 25KVAR, 3Ph, 415V all as specified and directed.
M & L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized iron strip 32 x 6 mm by means of GI bolts nuts, check nuts and washers etc all as shown in electrical plate No. 3 of SSR part 01 1996 including earth work PCC pit with cover, funnel with watering pipe, wire mesh and GI protection pipe light grade all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable all as directed.
Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Supply and spreading sand in trenches as cushioning to under ground cable on top and bottom of cable all as specified.
Supply and laying un-reinforced pre cast concrete cable cover class LV type I flat of size 250 x 150mm 40mm.
M& L for cement concrete type B-1 1:2:4 using 20 mm graded aggregate for road finishing / foundation etc.
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection .
M&L in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection .
Cutting of existing road/PCC for laying of LT cables complete all as specified and directed
Taking down unserviceable LT cables of size upto 120 sqmm complete all as specified and directed
Supply and lay cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm x 3.5 core
All as per item No . 20 here-in-before but of size 95 sqmm x 3.5 core
All as per item No .20 here-in-before but of size 70 sqmm x 3.5 core
All as per item No .20 here-in-before but of size 35 sqmm x 3.5 core
All as per item No. 20 here-in-before but of size 25 sqmm x 3.5 core
All as per item No. 20 here-in-before but of size 16 sqmm x 4 core
All as per item No. 20 here-in-before but of size 20 sqmm x 4 core
All as per item No. 20 here-in-before but of size 20 sqmm x 2 core
Taking down existing unserviceable burnt out end termination of LT UG cable from LT panel, pole box etc and taking out loop by excavation and repairs the cable by providing aluminium lugs and connecting up by replacing uncerviseable bolts nuts etc complete all as specified and directed of following sizes for 16 to 35 Sqmm 3.5/4 Core
All as per Item No 21 here-in-before but for 50 to 95 Sqmm 3.5 Core
All as per Item No 21 here-in-before but for 120 to 150 Sqmm 3.5 Core
Supply and fixing in repairs of multifunction panel meters for panel board of 3 phase, 4W IPM 240 V (L-N) 5 Amps panel mounted digital type meter of size 96mm x 96mm including modification of panel to fix complete all as specified and directed.
S&F in repairs of rubber mat suitable for 433V,of size approx. 2m x 1m x 10mm thick complete all as specified and directed
Material and labour for finding faults (any number in one running length) of LT under ground cables of size upto 185 sqmm by using computerised / primary current injection method /any other method and locating fault .Cutting removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at sitefor the following sizes. Note:-(i) Excavation earth work sand cushioning PCC cover etc will be measured and paid separately under relevant items of schedule here in after.(ii) Cable joint will be measured and paid separately.(iii) Additional length of cable required at site for jointing will be measured and paid separately
M&L for LT straight through joint heat shrinkiable suitable for 3 ½ / 4 core of following sizes underground cable all as specified and directed for 10 to 16 sqmm
All as per Item No 25 here-in-above but for 25 to 50 sqmm
All as per Item No 25 here-in-above but for 70 to 120 sqmm
All as per Item No 25 here-in-above but for 150 to 185 sqmm
S&F in repairs MCCB 250 Amps 4 pole, fixed type, 36 KA, 415 Volts complete all as specified and directed.
S&F in repairs of on load change over switch with front operated 4 pole, 400 amps, 415 volts, 50 Hz with sheet metal enclouser complete all as specified and directed
S&F in repairs MCCB 200 Amps 4 Pole, fixed type, 415 Volts, 36 KA complete all as specified and directed.
Taking down unserviceable security light fitting and Supply and fixing LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 3000lumens with maximum system wattage 25W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. including suitable pipe for bracket of 1.2 mtr complete all as specified. Make: Philips BRP046 LED 30 CW MR S1 PSU GR or Orsram / Keselec
S&F in repairs MCCB 100 Amps 4 Pole, fixed type, 415 Volts, 25 KA complete all as specified and directed.
S&F in repairs MCCB 63 Amps 4 Pole, fixed type, 415 Volts, 16 KA complete all as specified and directed.
S&F in repairs MCCB 200 Amps 3 Pole, fixed type, 415 Volts, 36 KA complete all as specified and directed.
Taking out existing terminal box and S&F Pole mounting type weather proof FRP terminal box of size 250 x 200 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and aluminium bus bar for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to street light pole with suitable MS iron flat of size 25 x 3 mm clamps fixed with GI Bolts, nuts and washer of suitable sizes all as specified and directed Make : Sintex/national
Taking down HPSV / MH street light fitting and Supply and fixLED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 6500lumens with maximum system wattage 60W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 110lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to Philips BRP062 LED 65 CW SLA S1 PSU Or Keselec / Osram
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 140 x 140 x 95 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall all as specified and directed Make : Sintex/national
M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (02 Run of 2.5sqmm and 01 Run of 1.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd
Surface dressing not exceeding 15 cms deep in soft / loose soil including removal of brick/stone pieces, herbs, shrubs and vegetation complete all as specified
S&F in repairs of Digital type display, three phase electric energy meter range 10A-60A, LED indicating for current reversal, phase voltage RYB, pulse output and anti-tamper features with poly carbonate enclouser with making incoming & outgoing cable connection with proper thimble and sealing the meter as specified and directed.(The cost of sealing of meter shall be included in the meter cost) Direct connected Wiring three phase, 4 wire, accuracy Class 1.0, Mains frequency 50 Hz, surge withstand capbility upto 8 KV complete all as specified and as directed make-L&T /Secure/Schnider Note :- Old electric meter shall be deposited in E/M store yard on own contractor cost.
M&L for preparing surface of existing painting of LT panel board and applying one coat of synthetic enamel paint including to repair hinges /door lock mechanism by necessary welding/ fabrication etc completeall as specified and directed
Disconnecting the incoming and out going cable connection and dismantling the unserviceable meters and meter board and removing from site for further disposal. Design fabricating supplying and fixing indoor type vermin and weatherproof totally enclosed cubical type front operated, sufficient ventilation on sides cubicle type fabricated out of 2mm thick CRCA sheet duly painted epoxy powder coated Siemens grey colour and with industrial type built in locking arrangement. The panel shall be factory made from a reputed panel fabricators (CPRI approved manufacturers). The panel shall be wall mounting type and to be fixed on wall with all necessary fixing arrangements complete. The panel to be prewired with PVC insulated copper conductors for monitors and heat shrinkable PVC insulated copper strips of appropriate current carrying capacity for connecting the incoming and out going MCCB and MCBs. Bldg no : 165, 166 &167 Note : unsv meter shall be deposited to mes store yard.All the control gears and electric meter to be provided in separate compartments with view glass and cable alleys busbar chambers etc to be provided in separate compartments and cable alleys busbar chambers etc to be provided with sufficient spacing . The following shall be provided :- (a) Copper busbar 200 Amps for phases and neutral duly sleeved with heat shrinkable insulation using colour code for R Y B &N set of 4- 01 Set.(b) MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 25 KA, fixed type - 01 No (incomer)(c) Fixing the existing electric energy meters - 09 Nos obtained from the existing panel of respective Qtrs (d) MCB SPN 32 Amps 240 V “C” series 09 Nos (out going ) (e) Indicator lamp RYB, LED type complete -01 set (f) multifunction panel meters 3 phase, 4W IPM 240 V (L-N) 5 Amps panel mounted digital type meter of size 96mm x 96mm
Supply and fixing of fire Extinguisher CO 2 type 2 Kg capacity to fixed on wall including fixing bracket complete all as specified and as directed.
Supply and fixing of fire Extinguisher CO 2 type 4.5/5 Kg capacity to fixed on wall including fixing bracket complete all as specified and as directed.
S&F in repairs of single phase static energy meters in LCD display from 10A-60A, 240 volts AC supply, tamper proof with making incoming & outgoing cable connection with proper thimble and sealing the meter as specified and directed.(The cost of sealing of meter shall be included in the meter cost) Direct connected Wiring Single phase, two wire Voltage range 230/240 V (L-N) Current range 10-60 A, Accuracy Class 1.0, Mains frequency 50 Hz ± 5% Burden , make-Secure/Schnider/HPL Note: ( a) . The meter shall have at least 4 temper recording (Phase reversal, earth loading indication, line load reversal, magnetic temper) available as Icons on LCD. (b). The meter shall display in absence of power supply Note :- Old electric meter shall be deposited in E/M store yard on own contractor cost.
NOEL ENGINEERS
Radha Engineering Services
AGRAWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .