Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC H N 48 GALI NO 3 PREM NAGAR HANSI HARYANA 125033 | HANSI | HISAR | HARYANA | 125033 | ₹4.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.9 LRejected-Finance 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | ₹4.9 L | L2 | Rejected-Finance L2 |
| 3 | L3₹5.0 LRejected-Finance 67 FIRST FLOOR SECTOR 9 11 HISAR 125005 | HISAR | HARYANA | 125005 | ₹5.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹5.9 LRejected-Finance VPO BARWA NEAR DO JHANTI DHAM STADIUM ROAD VPO BARWA 127045 | BARWA | BHIWANI | HARYANA | 127045 | ₹5.9 L | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical 1093 GALI NO 6 JAWAHAR NAGAR HISAR HARYANA | HISAR | HARYANA | 125001 | - | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | Virender Singh prop. Balaji electric company L2 | J D B POWER PROJECTS L3 | Pri-Power Enterprise L4 | DEVI ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] | 54 | Each | 100 ₹5,400 | 137 ₹7,398 | 120 ₹6,480 | 140 ₹7,560 |
| 2.00 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] | 6 | Each | 500 ₹3,000 | 1,297 ₹7,782 | 1,350 ₹8,100 | 1,200 ₹7,200 |
| 3.00 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] | 210 | Per Meter | 150 ₹31,500 | 177 ₹37,170 | 185 ₹38,850 | 160 ₹33,600 |
| 4.00 | [24.14.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] | 605 | Per Meter | 150 ₹90,750 | 187 ₹1.1 L | 190 ₹1.1 L | 160 ₹96,800 |
| 5.00 | [24.4.16]STREET LIGHT 16. Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement , housed in wall , including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections . [Through Rate] | 54 | Each | 200 ₹10,800 | 537 ₹28,998 | 603 ₹32,562 | 480 ₹25,920 |
| 6.00 | [24.4.7.2]STREET LIGHT 7.2. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia [Through Rate] | 30 | Per Meter | 200 ₹6,000 | 377 ₹11,310 | 431 ₹12,930 | 300 ₹9,000 |
| 7.00 | [24.5.1.1]MISCELLANEOUS ITEMS 1.1. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.
Submersible Copper Cable 3 Core 1.5 sqmm [Through Rate] | 96 | Per Meter | 57 ₹5,472 | 47 ₹4,512 | 50 ₹4,800 | 50 ₹4,800 |
| 8.00 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] | 190 | Per Meter | 80 ₹15,200 | 124 ₹23,560 | 100 ₹19,000 | 110 ₹20,900 |
| 9.00 | Supply and erection of MS Saddle and clamps duly galvanized , on wall / RCC parapet for fixing underground cable at a distance of 0.60 meter center to center fixed by means of raw plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work. (GST Exclusive) | 975 | Each | 5 ₹4,875 | 5.65 ₹5,508.75 | 7 ₹6,825 | 5 ₹4,875 |
| 10.00 | Supply and erection of 30 W LED Post lantern new generation energy saving envirmental friendly long life aesthetically desinged with symmetrical light distribution, spen aluminium land scap luminiaries with high power LED as light source with the protection of IP-66of LHEVBGP7PN 6K 025 (Rubby clear) of complete with all accessories and labour to complete the job upto the entire satisfaction of Engineer-in-charge of the work .Make Philips / Surya / wipro/ Bajaj (Exclusive GST) | 6 | Each | 4,500 ₹27,000 | 5,100.5 ₹30,603 | 3,600 ₹21,600 | 4,800 ₹28,800 |
Tender Value
₹5.3 L
EMD Value
₹10,527
Closing Date
26 Dec 2025, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Construction of Revenue Colony in Mini Secct. Colony Hisar (Pdg. Gate Light and Flood Light only)
2025_HRY_491727_1
20258FD9F1B3 4778 45D8 95C5 98C8DC79F0F3666BAR
Open Tender
Electrical Works
90 days
Hisar
2 documents required · 2 mandatory
₹1,000
₹10,527
Yes
25 Feb 2026
19 Dec 2025
29 Dec 2025
19 Dec 2025
26 Dec 2025
19 Dec 2025
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.14.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
Supply and erection of MS Saddle and clamps duly galvanized , on wall / RCC parapet for fixing underground cable at a distance of 0.60 meter center to center fixed by means of raw plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work. (GST Exclusive)
DSR No 8.17 ,LED Flood Light, powder coatedpressure die cast aluminium (System lumen efficacy )135lm/Watt) Supplying, Installation, Testing and Commissioningof Flood Light, powder coated pressure die cast aluminiumbody with built in or separate driver as per the requirementwith Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0Cto 50 0C, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC61000-3-2, P. F.=0.95, IP-66,IK-10, CRI )70,under voltageand over voltage protection EMI-EMC as per CISPR-15,lenses for beam angle 30 deg-120deg as perthe applicationand the project requirement., suitable tilt able fitting, life time(LED, Driver and electrical circuitry) of minimum50000Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-2111report, CCT3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM (Standard Deviation Colour Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output. LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C DSR No. 8.17.6 ( 250 W Flood Light ) Make :- Phillips , Wipro , surya,bajaj Rates Are exclusive Gst
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_570050.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid