Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹2.8 L
Closing Date
26 Dec 2025, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
WORKS
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. (For details refer tender documents)
Similar work means: Construction/ repairs/ maintenance of any Civil Engg. Work.
30 conditions · 2 needing a document upload
Whether History sheet of tenderers (Annexure-2 of Part-II of Tender documents) uploaded duly filled in with supportive documents.
Whether the details of facilities available vis-a-vis the requirements mentioned in STR in a tabular/narrative form if you are not on the approved list of RDSO, if required in the Annexed Document, is submitted.
Whether, EACH PAGE of the copy of documents/certificates in support of credential is self attested/digitally signed by tenderer/authorised representative with signature, stamp & date.
Whether all the documents related "Mandatory Requirement", as applicable and mentioned in the bid documents are enclosed with the tender.
Please submit bank details as per enclosed Annexure-12 of Part - II of Tender Documents or photo copy of a "Cancelled Cheque". (For details refer tender documents)
Please submit Certificate of Familiarisation as per Annexure-1 of Part-II of Tender Documents. (For details refer tender documents)
Please submit required details as required from Annexure 2 to 11 of Part-II of Tender documents duly filled in and signed. Supportive documents/separate sheet are to be submitted, if required. Annex-2: HISTORY SHEET OF THE TENDERER, Annex-3: TECHNICAL EIGIBILITY CRITERIA, Annex-4: DETAILS OF CONSTRUCTIONS MACHINERIES, TOOLS & PLANTS, VEHICLES ETC. AVAILABLE (ON HAND AND PROPOSED TO BE UTILISED, Annex-5: DETAILS OF TECHNICAL AND OTHER PERSONNELS AVAILABLE ON HAND & PROPOSED TO BE ENGAGED. Annex- 6: DETAILS OF WORKS COMPLETED DURING PREVIOUS THREE FINANCAIL YEARS & CURRENT YEAR, Annex-7: DETAILS OF WORKS ON HAND, Annex- 8: DECLARATION REGARDING ASSOCIATION OF RAILWAY OFFICER (S) WITH TENDERER(S), A n n e x - 9 : LIST OF COURT CASES, Annex-10: LIST OF ARBITRATION CASES. Annex- 11: BROAD PLAN FOR EXECUTION OF THIS WORK. (For details refer tender documents)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF)/ Limited Liability Partnership (LLP) etc. If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm/Partnership firm/Joint Venture/Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender . The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN card along with the tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (for details refer tender documents) NOTE: Any document containing PAN number of the tenderer(s) shall also be considered in lieu of PAN card. However, if no document having mention of PAN number is uploaded, offer will be summarily rejected. (For details refer Tender documents)
For all tenders having advertised cost of Rs.10 lakh or above, the contractor shall have to submit the option to take payment from Railways through a letter of credit (LC) arrangement. The tenderer shall affirm having read over and agreed to the terms and conditions of the LC option. The option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract. (The tenderer have to submit the option to take payment from Railway through a Letter of Credit arrangement) (For details refer Tender documents)
The list of personnel / organization on hand and proposed to be engaged for the tendered work. Similarly, list of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work. (For details refer tender documents)
Documents to be submitted as per Clause 14 of GCC-April 2022 in support of (a)Sole Proprietorship firm (b) HUF (c) Partnership Firm (d) Joint Venture (JV) (e) Company registered under Companies Act 2013 (f) LLP (Limited Liability Partnership) (g) Registered Society & Registered Trust. (for details refer tender documents) NOTE: Non submission of above documents will lead to summarily rejection of the offer.
Proposed repairs of miscellaneous work of Way side station staff Quarters and service buildings under the jurisdiction of ADEN/I/Cuttack of KUR division.
etenderEastkur-314-2025~ECOR
etenderEastkur-314-2025
Open
Works - General
12 Months
Khordha, Odisha
₹0
₹2.8 L
26 Dec 2025
4 Dec 2025
12 Dec 2025
86 items across 2 schedules · ₹2,52,07,808.75 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. | cum | 2000 | 494.1 | 9,88,200 |
| 2 | All kinds of soil | cum | 2000 | 177.5 | 3,55,000 |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | cum | 20 | 2,123.75 | 42,475 |
| 4 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | Sqm | 2000 | 17.6 | 35,200 |
| 5 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | cum | 200 | 7,878.5 | 15,75,700 |
| 6 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | cum | 250 | 6,812 | 17,03,000 |
| 7 | Lintels, beams, plinth beams, girders, bressummers and cantilevers | Sqm | 100 | 736.4 | 73,640 |
| 8 | Columns, Pillars, Piers, Abutments, Posts and Struts | Sqm | 100 | 961.3 | 96,130 |
| 9 | Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | cum | 20 | 20,355.8 | 4,07,116 |
| 10 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | Kg | 500 | 107.85 | 53,925 |
| 11 | Cement mortar 1:6 (1 cement : 6 coarse sand) | cum | 85 | 7,132.25 | 6,06,241.25 |
| 12 | With Modular bricks | cum | 100 | 8,942.35 | 8,94,235 |
| 13 | cement mortar 1:4 (1 cement : 4 coarse sand) | Sqm | 20 | 905.05 | 18,101 |
| 14 | Cement mortar 1:4 (1 cement :4 coarse sand) | Sqm | 80 | 1,123.8 | 89,904 |
| 15 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 800 | 1,267.95 | 10,14,360 |
| 16 | Fixed to steel windows by welding | Kg | 1000 | 219.1 | 2,19,100 |
| 17 | 100x60x2.50 mm | Each | 200 | 106.35 | 21,270 |
| 18 | 150x10 mm | Each | 120 | 82.55 | 9,906 |
| 19 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer- in-Charge. | Metre | 300 | 492.7 | 1,47,810 |
| 20 | 30 mm thick plain PVC door shutters | Sqm | 120 | 3,182.95 | 3,81,954 |
| 21 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. | Metre | 80 | 570.95 | 45,676 |
| 22 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. | Sqm | 40 | 3,720.75 | 1,48,830 |
| 23 | Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). | Sqm | 30 | 8,298.85 | 2,48,965.5 |
| 24 | 125 mm | Each | 15 | 119.2 | 1,788 |
| 25 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | Kg | 1200 | 133.7 | 1,60,440 |
| 26 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | Kg | 300 | 172.6 | 51,780 |
| 27 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). | Kg | 80 | 772.4 | 61,792 |
| 28 | 40 mm thick with 20 mm nominal size stone aggregate | Sqm | 500 | 614.2 | 3,07,100 |
| 29 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 800 | 1,315.3 | 10,52,240 |
| 30 | Size of Tile 600x600 mm | Sqm | 1500 | 1,553.45 | 23,30,175 |
| 31 | Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. | Sqm | 100 | 3,186.7 | 3,18,670 |
| 32 | 110 mm diameter | Metre | 300 | 377.4 | 1,13,220 |
| 33 | 110x110x110 mm | Each | 40 | 234.15 | 9,366 |
| 34 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in- charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 500 | 738.65 | 3,69,325 |
| 35 | Gutter (600 mm over all girth) | Metre | 500 | 1,313.7 | 6,56,850 |
| 36 | 1:6 (1 cement: 6 fine sand) | Sqm | 1500 | 383 | 5,74,500 |
| 37 | Neat cement punning. | Sqm | 200 | 79.95 | 15,990 |
| 38 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. | Sqm | 500 | 262.7 | 1,31,350 |
| 39 | Two or more coats on new work | Sqm | 50 | 155.9 | 7,795 |
| 40 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | Sqm | 100 | 156.05 | 15,605 |
| 41 | Old work (one or more coats) | Sqm | 7000 | 62.7 | 4,38,900 |
| 42 | Two coats | Sqm | 3000 | 137.45 | 4,12,350 |
| 43 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | Sqm | 17000 | 25.15 | 4,27,550 |
| 44 | One or more coats on old work | Sqm | 500 | 102.8 | 51,400 |
| 45 | One or more coats on old work | Sqm | 1500 | 96 | 1,44,000 |
| 46 | Old work (one or more coats @ 2.20 kg/10 sqm) complete. | Sqm | 1000 | 75.8 | 75,800 |
| 47 | Old work (one or more coats applied @ 0.83 ltr/10 sqm). | Sqm | 7000 | 88.55 | 6,19,850 |
| 48 | 2mm (for corrugated roof sheets) | Sqm | 200 | 498.35 | 99,670 |
| 49 | 3 mm thick | Sqm | 2000 | 537.45 | 10,74,900 |
| 50 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) | cum | 20 | 2,434.25 | 48,685 |
| 51 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | cum | 30 | 3,551.25 | 1,06,537.5 |
| 52 | In cement mortar | cum | 90 | 2,060.2 | 1,85,418 |
| 53 | Of area 3 sq. metres and below | Each | 180 | 367.2 | 66,096 |
| 54 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | Sqm | 2300 | 54.65 | 1,25,695 |
| 55 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . | cum | 300 | 1,046.95 | 3,14,085 |
| 56 | On W.B.M / W.M.M. @ 0.4kg/sqm | Sqm | 2000 | 13.45 | 26,900 |
| 57 | 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. | cum | 200 | 12,126.2 | 24,25,240 |
| 58 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. | Sqm | 200 | 1,091.5 | 2,18,300 |
| 59 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 50 | 6,767.4 | 3,38,370 |
| 60 | W.C. pan with ISI marked white solid plastic seat and lid | Each | 30 | 6,515.55 | 1,95,466.5 |
| 61 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 30 | 2,648.85 | 79,465.5 |
| 62 | 610x460 mm bowl depth 200 mm | Each | 40 | 3,873.8 | 1,54,952 |
| 63 | 15 mm nominal dia Pipes | Metre | 30 | 244.7 | 7,341 |
| 64 | 20 mm nominal dia Pipes | Metre | 150 | 274.3 | 41,145 |
| 65 | 25 mm nominal dia Pipes | Metre | 120 | 355.4 | 42,648 |
| 66 | 50 mm nominal dia Pipes | Metre | 600 | 794.25 | 4,76,550 |
| 67 | 20 mm nominal bore | Each | 30 | 462.5 | 13,875 |
| 68 | 25 mm nominal bore | Each | 30 | 464.05 | 13,921.5 |
| 69 | Class II | Each | 4 | 4,985.85 | 19,943.4 |
| 70 | Class II | Each | 4 | 7,312.4 | 29,249.6 |
| 71 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Per Litre | 30000 | 11 | 3,30,000 |
| 72 | 15 mm nominal bore, 86 mm long, weighing not less than 88 gms | Each | 80 | 125.6 | 10,048 |
| 73 | 15 mm nominal bore, 86 mm long, weighing not less than 88 gms | Each | 30 | 118.5 | 3,555 |
| 74 | 15 mm nominal bore, 107 mm long, weighing not less than 110 gms | Each | 10 | 208.45 | 2,084.5 |
| 75 | 100 mm dia Ductile Iron Class K-7 pipes | Metre | 100 | 1,257.8 | 1,25,780 |
| 76 | 150 mm dia Ductile Iron Class K-7 pipes | Metre | 50 | 1,789.6 | 89,480 |
| 77 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) | Kg | 100 | 495.05 | 49,505 |
| 78 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) | Kg | 150 | 598.6 | 89,790 |
| 79 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) | Sqm | 40 | 1,505.25 | 60,210 |
| 80 | With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. | Sqm | 150 | 1,907.35 | 2,86,102.5 |
| 81 | 25 mm average thickness | Sqm | 200 | 126.75 | 25,350 |
| 82 | Bars upto 12 mm diameter | Metre | 100 | 8.25 | 825 |
| 83 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make | Sqm | 200 | 285.2 | 57,040 |
| Schedule total | ₹2,47,58,798.75 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .