Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAdmitted-Finance | ₹2.2 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical 216 BHARAT NAGAR INDRAPURI BHOPAL MADHYA PRADESH 462021 | BHOPAL | MADHYA PRADESH | 462021 | - | - | Rejected-Technical Technically Not Qualified |
| 3 | Rejected-Technical 810 VISHWASADAN TOWER DISTRICT CENTRE JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | Supreme Audiotek Pvt Ltd. L1 |
|---|---|---|---|---|
| 1.00Sub Head-1 | ||||
| 2.00INTELLIGENT FIRE ALARM SYSTEM | ||||
| 3.00Supplying, installation, testing and commissioning of fire micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less then 240 device (including detector) and minimum 120 detector per loop and loop length up to 2 km, network communication card , graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5% v, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with digital voice evacuation system ( which is part of the schedule of work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BCA net / Modbus over IP complete as per specifications. (The FAP shall have inbuilt talk-back system) | ||||
| 4.00 | Ten Loop Panel | 2 | Each | - |
| 5.00 | Two Loop Panel | 1 | Each | - |
| 6.00 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required as per specifications. | 1 | Each | - |
| 7.00 | Supplying, installation, testing & commissioning of repeater panel with 320 character / Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required as per specifications. | 1 | Each | - |
| 8.00 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mountingh base complete as reqired as per specifications. | 2,300 | Each | - |
| 9.00 | Supplying, installation, testingh & commissioning of response indicator on surfece / recessed MS box having two LED, metallic cover complete with all connection etc as reqiuired as per specifications. | 400 | Each | - |
| 10.00 | Supplying , installation, testing & commission of intelligent addresseble programmeble sounder complete as required as per specifications. | 30 | Each | - |
Tender Value
₹2.4 Cr
EMD Value
₹4.8 L
Closing Date
16 Oct 2019, 3:00 pmClosed
Executive Engineer Electrical
Works Organisation, Hauz Khas, IIT Delhi, New Delhi 110016
Augmentation of Fire Detection System in M.S. Building at IIT Delhi
2019_IIT_503880_1
IITD/WORKS(SP-2520)/2019
Open Tender
Miscellaneous Works
Supply
90 days
IIT Delhi, Hauz Khas, New Delhi
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹4.8 L
24 Jul 2020
18 Sept 2019
17 Oct 2019
18 Sept 2019
16 Oct 2019
18 Sept 2019
Amount
Sub Head-1
INTELLIGENT FIRE ALARM SYSTEM
Ten Loop Panel
Two Loop Panel
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required as per specifications.
Supplying, installation, testing & commissioning of repeater panel with 320 character / Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required as per specifications.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mountingh base complete as reqired as per specifications.
Supplying, installation, testingh & commissioning of response indicator on surfece / recessed MS box having two LED, metallic cover complete with all connection etc as reqiuired as per specifications.
Supplying , installation, testing & commission of intelligent addresseble programmeble sounder complete as required as per specifications.
Supllying, intallation, testing & commissioning of fault isolator comlete with base as required as per specifications.
Supplying, intallation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required as per specifications.
Supplying, installation, testing & coomissioning of addressable fire control module complete as required as per specifications.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt of separate) complete with emitter and receiver including connections with remote test features etc complete as required as per specifications.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable photo detector complete with base as required as per specifications.
Supplying, installation, testing & commissioning of intelligent addressable multi criteria [smoke + Heat + CO + IR] detector including suitable photo detector complete with base as required as per specifications.
Supplying, installation, testing & commissioning of intelligent addressable High Sensitivity Photo Detector with sensitivity level of 0.02% to 2% Obs/Feet. The detector shall have the parabolic amplifier to focus the light beam to a very small volume near the receiving photo sensor at the incipient stage of fire- when the smoke particles are lesser than 0.3 microns intrudes inside the detection chamber & shall have better response time at much earlier stage of fire.. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches as per specifications.
Supplying, installation, testing & commissioning of addresable manual call point complete as required as per specifications.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required as per specifications.
Supplying, installation, testing & commissioning of addressable strobe complete as required as per specifications.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required as per specifications.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required as per specifications.
Supplying, installation, testing & commissioning addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide DPDT contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of 6 zone, digital voice alarm controller with USB, MP3 player (including 6 zone button paging station ) with seamless integration facility with main fire alarm panel for voice evacuation complete as required as per specifications.
Supplying, installation, testing & commissioning of 1.5/3/6W ceilling speaker complete as required as per specifications.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/ speakers complete as required as per specifications.
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 watt in ABS enclosure complete as required as per specifications.
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required as per specifications.
Supplying, installation, testing & commissioning of digital audio amplifier 50 watt, 25V rms operating at 240 volt AC supply complete as required as per specifications.
Supplying, installation, testing & commissioning of digital audio amplifier 75 watt, 25V rms operating at 240 volt AC supply complete as required as per specifications.
Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with sound pulse petterns complete as required as per specifications.
Supplying, installation, testing & commissioning of voice commond keypad 6 zone, with microphone assembly complete as reqiured.
CABLING & WIRING
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed coper conductor having glass mica fire barrier tape coverd by an extruded layer of cross linkable ethylene propylene rubber (EPR) insualtion and LSZH inner bedding, steel wire armouring & LSZH outersheath complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed coper conductor having XLPE insuulation, steel wire armouring & FRLS outer sheath complete as required.
supplyingh and drawing of cable fire retardant PVC insulated copper conduter cable in the exitingh surface / recessed steel conduit of following pairs, coress and size including connections and interconnections etc. as required
Speaker cable single pair, 2-core,1.5 sqmm
Speaker cable two pair, 2-core,1.5 sqmm
Speaker cable three pair, 2-core,1.5 sqmm
Speaker cable four pair, 2-core,1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required
Supplying, installation, testing and commission of cloud based facility management software for remote health monitoring utilising cloud based software-as-a-service web application and supplementary network gateway software. System shall provide secure web access to cloud based web application using any of the web browsers like Google Chrome (preferable), Internet Explorer etc. from any computer/ tablet/ smartphone connected over internet via defined credentials – username and password. The cloud based web application shall capture all fire alarm system data as received from the system via supplementary gateway hardware of the same make as Fire Alarm Panel. The software shall display real time view of fire system effectiveness, multi-location unified view, custom dashboard, device level information, 100000 events, scheduled reporting, e-mail of critical alarms as per specifications.
Dismantling of the old fire detection system including removing of cable, detector, call points, R.I.s, Panels, etc. mending good the damages and dumping all dismantled items at a designated place in IIT Delhi etc. as directed.
(Supplementary Agreement shall be formed for Sub Head - 2)
Sub Head - 2 ( Round the Clock Monitoring & Maintenance)
Routine, preventive and breakdown maintenance & round the clock x 7 days monitoring of installed Fire Detection & Alarm system by deputing skilled technical [minimum ITI Electrical / Electronics / Instrumentation passed] person[s] who shall be vigilant and be available round the clock x 7 days etc. as required. [N.B. - [a] Materials, if any, required due to fault / malfunction of the system during DLP to be given & to be replaced by the contractor [b] Attendance of deputed staff shall be maintained through manual as well as biometric machine to be kept in the fire control room [c] any shortfall of attendance of staff will affect the billing proportionately [d] Latest Labour regulation shall be complied strictly]. 1 Job means for a period of 01 month N.B.:: 1st year to be done free of cost [to be reckoned from the date of commissioning of the entire installations to the satisfaction of the Engineer-in-charge]
2nd year
3rd year
4th year
5th year
Buy back of old dismantled Fire Detection System components:
Detector [approx 2000 nos]
Call Point [approx 20 nos]
R.I. [approx 250 nos]
Cable [approx 9000 metre of different sizes]
Hooter [ approx 70 nos]
Panel [approx 12 nos]
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_527620.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .