| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC | ₹4.5 L | L1 | Accepted-AOC Lowest tenderer |
| 2 | L2₹5.9 L+₹1.4 L (30.6%)Rejected-Finance | ₹5.9 L+₹1.4 L (30.6%) | L2 | Rejected-Finance Other than Lowest tenderer |
| 3 | L3₹6.0 L+₹1.5 L (33.3%)Rejected-Finance | ₹6.0 L+₹1.5 L (33.3%) | L3 | Rejected-Finance Other than Lowest tenderer |
| 4 | L4₹7.6 L+₹3.2 L (70.4%)Rejected-Finance | ₹7.6 L+₹3.2 L (70.4%) | L4 | Rejected-Finance Other than Lowest tenderer |
| 5 | Rejected-Technical MULTICARE ENTERPRISES PRIVATE LIMITED COMMERCIAL COMPLEX VARDHMAN TOWER PREE T VIHAR G 63 GROUND FLOOR PLOT NO 16 17 18 110092 DELHI EAST DELHI N N 110092 | EAST DELHI | DELHI | 110092 | - | - | Rejected-Technical DD for tender cost not received. Notice was given in short fall to upload DD but not uploaded |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
12 Apr 2022, 6:00 pmClosed
Maj Aditya Gorhe
GE Utility Bathinda Mil stn
REPAIR / MAINTENANCE OF ELECTRIC PANEL, UG CABLE AND EARTHING OF AC PLANTS AND CONNECTED ITEMS UNDER GE (U) BATHINDA.
2022_MES_513393_1
8635/2022-23/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
Garrison Engineer Utility Bathinda
class E cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹20,000
Yes
11 May 2022
12 Mar 2022
14 Apr 2022
12 Mar 2022
12 Apr 2022
28 Mar 2022
Amount
Supply and fix in repair MCCB 25 A, 4 Pole 16 KA with thermal magnetic releaase, Ics-100%Icu, four optimum frames, Thermal Adjustable - 0.8 to 1 In, option for inbuilt or add on module for earth leakage protection complete all as directed.
All as per serial item No. 01 above but for MCCB 63 A, 4 Pole ,16 KA.
All as per serial item No. 01 above but for MCCB 100 A, 4 Pole, 16 KA
All as per serial item No. 01 above but for MCCB 125 A, 4 Pole, 25 KA
All as per serial item No. 01 above but for MCCB 160 A, 4 Pole, 25 KA
All as per serial item No. 01 above but for MCCB 200 A, 4 Pole, 25 KA
All as per serial item No. 01 above but for MCCB 250 A, 4 Pole, 25 KA
All as per serial item No. 01 above but for MCCB 250 A, 4 Pole, 36 KA
All as per serial item No. 01 above but for MCCB 320 A, 4 Pole, 36 KA
All as per serial item No. 01 above but for MCCB 400 A, 4 Pole, 36 KA
All as per serial item No. 01 above but for MCCB 630 A, 4 Pole, 36 KA
Supply and fix in repair power contactor of AC3 rating, 03 pole, with 1NO+1NC Aux Contacts, 415V , type MNX 09, 25 A including making all electric connection, complete all as directed.
All as per serial item No. 12 above but for power contactor of type MNX 18, 30 A
All as per serial item No. 12 above but for power contactor of type MNX 25, 45 A
All as per serial item No. 12 above but for power contactor of type MNX 32, 55 A
All as per serial item No. 12 above but for power contactor of type ML 02, 40 A
All as per serial item No. 12 above but for power contactor of type ML 1.5, 25 A
All as per serial item No. 12 above but for power contactor of type MO 12, 32 A
All as per serial item No. 12 above but for power contactor of type MO 18, 32 A
All as per serial item No. 12 above but for power contactor of type MO 45, 50 A
Supply and fix in repair over load relay range 17-25.5 Amps, with built in single phase preventer, direct / separate mounting on contactors, as required including making all electric connections complete all as directed. Make : L&T cat part No CS96356OODO/ Schneider Elect / Siemens / C&S / Legrand
All as per serial item No. 21 above but for over load relay range 8.5 to 12.5 Amps. Make : L&T cat part No CS96355OOAO/ Schneider Elect / Siemens / C&S / Legrand
All as per serial item No. 21 above but for over load relay range 3.5 to 5.2 Amps. Make : L&T cat part No CS96355OOSO/ Schneider Elect / Siemens / C&S / Legrand
All as per serial item No. 21 above but for over load relay type MN2, range 20-33 Amps. Make : L&T / Schneider Elect / Siemens / C&S / Legrand
All as per serial item No. 21 above but for over load relay type MN2, range 14-23 Amps. Make : L&T / Schneider Elect / Siemens / C&S / Legrand
All as per serial item No. 21 above but for over load relay type MN2, range 4.5-7.5 Amps. Make : L&T / Schneider Elect / Siemens / C&S / Legrand
Supply & fix in repair LED type indicator lamp of red/blue/green colour for phase indication, complete all as directed. Make : Siemens / Schneider Elect / L&T / Essbee / C&S
Supply & fix in repair push button, projecting head (push function) type, complete all as directed. Make : C&S / Converse / Salzer / Schneider Elect / BCH
Taking down carefully existing copper/aluminium point wiring (light/fan/call bell) complete with all accessories such as switches sockets ceiling rose, wall bracket etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface etc complete all as directed.
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including PVC conduit 20 mm dia medium grade ISI marked, PVC gang boxes mounting on wall including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid separately under appropriate items ).
All as per serial item No 32 above but for one socket out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor FR-LSH cable and 1.5 sqmm PVC insulated copper conductor FR-LSH cable as earth contiuity conductor.
Supply and fix switch piano flush type 5/6 Amp 230V AC one way complete all as directed.
Supply and fix one switch and one socket 3 pin 5 and 5 pin 15 Amp 230 volts AC including cover plate complete all as directed. (Switch and socket shall be of same make)
Supply and fix ceiling rose surface type bakelite 65x50mm two to three terminal 230V complete all as directed.
Supply and fix in repair double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting TPN, 4 way, 415 Volts, with 200 Amp rated bus bar suitable for fixing MCBs, isolators including making good disturbed surface with the help of sand and cement as per site requirement complete all as directed.
Supply and fix MCB 230V , 40 to 63 Amp, TPN 'C' curve having repturing capacityof 10KA complete all as directed.
Supply and fix MCB 6 Amp to 32 Amp SP 10 KA ‘C’ series complete all as directed.
M & L for Sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable FR-LSH conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 Sqmm single core PVC insulated & unsheathed copper conductor FR-LSH cable as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing including taking down old unserviceable sub main wiring complete all as specified and directed. (Note : 2 runs of 4 sqmm cable, 1 run of 2.5 sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run).
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / hard standing /along poles and testing XLPE LT Cable, with PVC outer sheath Type-I as per IS - 5831, insulated stranded aluminium conductor as Per Class-2 of IS - 8130 served with and inner sheathining of PVC tape- ST-I as per IS-5831 color Red, Yellow, Blue & Black ,armoured with Galvanised steel strip or wire and over all PVC sheathed stranded conductor conforming to IS-1554 (Part-I & II) with latest amendments of Size cross sectional area 10 Sqmm 2 core ,1100 volts grade heavy duty complete all as specified and as directed.
All as per serial item No. 43 above but for LT UG Cable 16 Sqmm 4 Core.
All as per serial item No. 43 above but for LT UG Cable 35 Sqmm 3.5 Core.
All as per serial item No. 43 above but for LT UG Cable 50 Sqmm 3.5 Core.
Material & labour sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. ( Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supplying, fixing, connecting & testing energy efficient LED Flood light fitting 100 Watt exclusive innovative designed, long life versatile pressure die cast aluminium IP 65 luminaire with high power LED as light source with two nos of suitable clamps and connecting to existing circuit with using 2.5 sqm aluminium conductor PVC insulated three core copper cable including taking down old existing unserviceable light fittings complete all as directed. Make : Havells Model No LHEUACN7PN6K100 or equivalent make of Surya/ Crompton/Wipro/Osram.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in (1 : 2 : 4) type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: (i) The cost of earth lead wire and its protection pipe upto 7.5 Metre from the top of earth electrode are included under this item.
PREM ENTERPRISES
M/s Kataria Construction Company
PRAJAPATI E and S ENGG CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .