Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹42.1 L
Closing Date
30 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrical and allied works for 04-Storeyed Research Hostel at Zakura Campus (Balance Work).
2022_UDJK_166510_1
F(E.Tend)(UCD)/KU/02/22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Zakura Campus
As per NIT
3 documents required · 3 mandatory
₹1,100
Registrar University of Kashmir
Exempted
4 May 2022
12 Apr 2022
4 May 2022
12 Apr 2022
30 Apr 2022
12 Apr 2022
120 days
Amount
EXETRNAL FEEDER PILLER NON DSR ITEMS Supply, installation, testing and commissioning of outdoor type External Feeder Pillar complete with busbars , M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables, with following material in each as per Single line diagram complete as required in cement foundation complete. (MR) "EXTERNAL FEEDER PILLAR(TYPE-1) shall consists of : Note : Enclosure should be IP54 protected " INCOMER 1No., 63 Amps DP (15kA) MCB (Icu ) having IP 20 Protection, CE Approved, Applicable BIS Standards (ISI mark, IS 8828-1996, IEC 898) "Indicating lamps (LED) with protection MCB for Incomer i) ON, OFF, Trip indication. Ii) RYB indication." Voltmeter, Ammeter and KWH with 1 set of CT's of 125/5 Amp. BUSBAR 63 Amp DP busbars of aluminium alloy. TIMER 1 No. 40A Digital , 365 Days, 24 HRS. Programmable astronomical timer with suitable contactor. OUTGOINGS 10 nos. 25 AMPS SP MCB( C- Curve), 10KA for Light Circuit having IP 20 Protection, CE Approved, Applicable BIS Standards
LIGHT FIXTURES NON DSR ITEMS Providing and Fixing of lighting fixture pressure die-cast aluminium IP66 roadway luminaire with high power LED(30W) as light source with toughened glass applicable BIS Standards and ISI Marks etc. Certification: LM79-08, LM80, L70, NABL etc.
Providing and fixing of 0.75meter long MS Painted outdoor luminary arms for holding 1 no luminary and duly fitted on the pole with clean Welding job i/c Supplying/Applying priming coat with ready mixed red oxide Zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works and anti-corrosive Bitumastic paint of approved brand and manufacture to give an even shade. two or more coats work as per requirement.
LT CABLE NON DSR ITEMS Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. having ISO 9001/14001 marks etc.
(MR) 16 sqmm 2 core
(MR) 50 sqmm 2 core
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required. Upto 35 sq. mm
EARTHING & MISCELLANEOUS DSR ITEMS (DSR 5.4) "Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Note:-Described item only for earthing of Feeder Piller." Point taken upto desired panel
(MR) Supply of advance maintenance free Chemical Gel Earthing of Single Pipe Technology of 3mtrs length 60-63 mm dia CHEMRODE filled with highly conducting metallic compounds with the permanant sealings at the both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connected the strip/wire to the load. Point taken upto desired panel
Supply of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
MISCELLANEOUS D.S.R.ITEMS (DSR 2.21) Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red colour on front side as required.
Supply, laying, jointing, testing and commissioning of ISI marked (IS : 14930, part 2) H.D.P.E. (DWC) Double wall Corrugated pipe for cable laying having corrugation on outer wall and plain smooth surface at inner side including transportation upto the site, jointing, providing and fixing all fittings i.e. sockets, couplers, reducers, end caps etc to complete the works in all respects.
(MR) 50 mm OD
(MR) 175 mm. ID / 210 mm OD
(MR) Design, fabrication, supplying to site of installation, testing and commissioning of 4 meter height above ground level M.S. Tubular steel poles of 100 mm dia steel pipe with suitable size of reducer for fixing light fixture i/c Supplying/Applying priming coat with ready mixed red oxide Zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works and supplying&applying anti-corrosive Bitumastic paint of approved brand and manufacture to give an even shade. two or more coats work as per requirement. suitable cable entry space as per requirement and standard design i/c base plate for 4 no. places to insert bolts
Providing & Laying of cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size)for G I poles 18”x18”x36” (2'' below ground level) i/c cost of plaster the outer surface with frame work curing, shuttering and anti-corrisive Bitumastic paint two coats etc. with anchor bolts structure for mounting pole. Foundation size may varry as per site requirement
Providing and fixing of suitable size IP 65 or equivalent protected Cable Junction Box for poles 6sq mm terminal block with water tight cover and suitable cable entry space as per requirement and standard design with 2 coatts of anti-corrisive paint Note:-(i)Cost of termination of incoming and out going cable in pole box shall be include with the above item.
(DSR 1.7.1) Wiring for light pole alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, two core cable ISO Certified having Acceptance Tests, Type Tests, Routine Tests, Optional Tests etc. in surface/ recessed medium class PVC conduit as required. 2CX 1.5 sq. mm
(MR) Providing & Laying in position, alignment, jointing etc RCC hume pipes 300mm(1 feet) dia of NP2 class for culverts, road crossing, including cutting, collars jointing etc all complete as per specifications, drawing and direction of EIC. Excavation, backfilling, PCC 1:5:10 (1 Cement: 5 Fine aggregate: 10 Coarse aggregates) alround the pipe to be included in rates.
Supplying and fixing 2A rating, Double Pole 240/415 V, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required pertaining to IEC 60947-2 standards
Supplying and Erection of Steel Tubular poles (9m) complete with base plate & top cap for tapping point including drilled holes for supporting channel including carriage chargers, loading/unloading and Erection of steel tubular or rail pole strut in cement concrete foundation including excavation and refilling i/c Painting of poles with primer coat/paint coat
Providing & Laying of cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) for poles 18”x18”x28” i/c cost of plaster the outer surface with frame work curing, shuttering and apex two coats etc. with anchor bolts structure for mounting pole i/c 2 coats of anti-corrisive paint
Providing and fixing of suitable size IP 65 or equivalent protected Cable Junction Box for poles having space for 4 Nos 2A DP MCB & 6sq mm terminal block with water tight cover and suitable cable entry space as per requirement and standard design and 2 coats of anti-corrisive paint Note:-(i)Cost of termination of incoming and out going cable in pole box and 04 no's 2 A D.P MCB shall be include with the above item.
Providing and fixing of 2 row frame structure to accommodate 4 flood lights of M.S. Pipe of suitable diameter to fit on pole with bolts keeping opening for cable entry duly painted with minimum coating of 10 micron to be kept at suitable angle i/c Supplying/Applying priming coat with ready mixed red oxide Zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works and anti-corrosive Bitumastic paint of approved brand and manufacture to give an even shade. two or more coats work as per requirement, having clean welds
Providing and Fixing of lighting fixture pressure die-cast aluminium IP66 roadway luminaire with high power LED(120W)with toughened glass
Supplying, Installation, Testing and Commissioning of Silent Diesel Generator Set 50 kVA, 3 Phase, 50 Hz Air Cooled Silent DG Set comprising of Air cooled Diesel Engine & Alternator rated at Three Phase, 415V, 50 Hz both mounted and aligned on a common MS base frame complete with manual panel, fuel tank, Residential Exhaust Silencer, 12 V battery, AVM Pad, Maintenance Free Battery lead fitted in Sound Proof acoustic enclosure approved by CPCB. Governing class (As per ISO 8528 Part-V), Noise level <75 dBA, Rated output :Prime Continuous rating as per ISO 8528-1, 1500RPM/50Hz, ALternator Insulation Class H, Voltage Reg: +-1%
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Constructing of masonry Chamber 100x100x100 cm, inside with 75 class designation brick work in cement moryar 1:5 ( 1 cement : 5 fine sand ) for valve, with C.I.surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design (NOTE: Actual Depth of chamber may vary as per Site conditions).
Supply, Installation, Testing and Commissioning of 20 kVA servo stabilizer Digital Microcontroller Buck booster Servo Voltage Stabilizer 3 phase 4 wire out-door Radiator type (3 phase: 230 V to 460 V input and 415 V Out put) of with fresh dehydrated oil. With protection, complete in all respects.(Specifications are attached) 1. High & low voltage Cut off 2. Over current protection, SC Protection 2. Cooling:- ONAN 3. Time delay protection
Supplying/transportation/insurance/ installation/testing/ commissioning of pilfer resistant 11KV metering Kiosk suitable for housing Resin cast CT, PT and bi-directional Tri-vector meter fabricated out of MS Sheet steel of thickness not less than 2mm duly powder coat painted. The foundation base should be of MS channel iron not less than 100mmx50mmx6mm should be suitably grouted in M15 cement concrete. it should have two chambers, HV chamber and LV chamber both chambers having one side hanged door arrangement. The LV chamber shall be suitable for installation of tri-vector meter and HV chamber suitable for installation of CTs/PTs and termination of 11KV cable. it should be possible to take meter readings manually, through CMR and computer without opening the LV chamber door, including 11KV cables, the chamber also should contain the following essentials. a) 11kv CT 1set 30/5 Amp ISI mark. b) 11Kv/110V PT 3phase 1set resin cost of ISI mark. c) 1 set of copper bus bar duly insulated by the monopolist tape. d) Nuts bolts washers of brass as required. e) 1 lot of PVC insulated copper wire flexible multi-strand multi-core of required size for secondary connection. For CT wiring the minimum size shall be 4mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB). f) Copper lugs preferably ring type duly crimped for termination of wires and cables. g) Grounding bus bar of minimum 40mm copper 25cm long fixed to the unit in HV chamber. The CTs and 11KV Cable sheath shall be grounded to the bus through grounding wire (green) of minimum 10mm2. h) Supply/ fixing /testing/ commissioning of DLMS complaint HT, bi-directional Tri-vector meter of 3 phase/4wire/--5Amp &110/63.5volt i) Supply/ fixing /testing/ commissioning of 3 core 11KV aluminum XLPE armored cable 50mm2 of make including cost of thimbles/ clamps for fixing where ever required complete in all respects. j) Supply/ fixing /testing/ commissioning of Heat Shrink outdoor cable termination kit suitable for 3x35mm, 11KV cable ISI mark. 4set k) Supply/ fixing /testing/ commissioning of Heat Shrink indoor cable termination kit suitable for 3x35mm2 11KV cable ISI mark. 2set l) Supply/ fixing of grounding to the metering in 40mm dia GI pipe 2.5 meter long including connectivity in all respects as per site requirement 2no.
Providing/fixing of MS Channel Iron 75x40x40x6 mm 9' long (06+08 No.'s) for LA's, DO's & Link Set's duly painted & transformer bed. ISI mark.
Providing/fixing /testing/ commissioning of 11KV Lighting Arrester Set (Station type) ISI Mark
Providing/fixing /testing/ commissioning of 11KV pin type insulator including pin ISI Mark
Providing and fixing of 11kV, Air Break Switch gang operated 11kV Polymer Type
Providing/fixing /testing/ commissioning of 11 KV Drop-out set (Horn-gap type) Heavy Duty ISI Mark
Supplying of single core, LT 400 sq.mm aluminium armoured power cable of 1.1kV grade confirming to IS 7098 having ISI Marks, including cost of iron clamping, cable end jointing with cast resin compound, and other jointing materials/kit including thimbling complete as per site requirement complete
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Providing/fixing of Solder less Clamps 400mm² ISI mark.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR 5.4)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (DSR 5.6)
Providing and fixing of outdoor type MS Steel cubical panel having minimum thickness of 2mm, double doors, dust and vermin proof in cement foundation of M20 of required size. Two coats of epoxy based primer shall be applied before applying two final coats of epoxy paint. Electrostatic epoxy powder coating shall be applied after pre-treatment.The colour of paint shall be RAL 2009 including providing and fixing of following equipments with required sizes of thimbles: a) 630A MCCB TPN, 50kA complete with lug sets for both ends =1 No. shunt trip coil, adjustable O/L, S/C, E/F release 1 to 0.8 adjustable current having ISI mark, pertaining to IS 8828-1996, IEC 898 b) end termination with brass compression gland c) Phase indication R,Y,B d) 800 Amp aluminium busbars of suitable length. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminium shall not be more than 0.8 Amps/ sq.mm. e) 1 Set of Amp meter, Volt Meter & Frequency Meter with 1 set of CT's for outgoing feeder.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(DSR 5.15)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.(DSR 5.14)
Providing/fixing of MS Nuts & Bolts /washers (Galvanized of sorts)
Providing/fixing of GI Strip for LA Earthing as required. IS standard.
Providing/fixing of Anti-Climbing Devices heavy duty as per IS standards.
Providing/fixing of 0.05 ACSR Aluminium Conductor ISI Standard.
Supply/ fixing /testing/ commissioning of HT 3 core 11KV aluminum XLPE armored cable 50 mm2 including cost of thimbles/ clamps for fixing where ever required complete in all respects Conforming to IS 7098 (Part-2) 2011 with upto Date Amendments.
Supply/ fixing /testing/ commissioning of Heat Shrink outdoor cable termination kit suitable for 3x35mm, 11KV cable ISI mark
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench including sand cushioning and protective covering etc., complete as required. 300 mm dia for road cross
Supplying /fixing /testing/ commissioning of outdoor type, 400 kVA transformer, level 2 11KV/440V, 50 Hz, 3ø, delta- star connections, ONAN type cooling, IP 55 Degree of protection, DYN11 Vector group (ISI mark) ,Copper as winding material, fully insulated, including all charges, accessories( Silica gel breather,Pressure relief valve, Wheels,Rating and Diagram Plate,Lifting Lugs. etc.) having Oil Temperature Indicator with enclosure, Winding Temperature Indicator with enclosure, dehydration heat run complete including cost of transformer oil, loading & un-loading, transportation complete in all respects etc . Complete job Note: All material used in manufacturing should be ISI certified and manufacturer be ISO certified
Supplying and Erection of Steel Tubular poles (9m) complete with base plate & top cap for tapping point including drilled holes for supporting channel including carriage chargers, loading/unloading and Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling i/c Painting of poles with primer coat/paint coat pertaining to IS: 2713 (Part I to III)
Supplying and Erection of Steel Tubular poles (3m) complete with base plate & top cap for tapping point including drilled holes for supporting channel including carriage chargers, loading/unloading and Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling i/c Painting of poles with primer coat/paint coat pertaining to IS: 2713 (Part I to III)
Supplying and fixing approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liters capacity as per IS:2546:1974 and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 4 buckets).
First Aid Kit as per Red Cross Standards, complete with Medicines for Burns, Cut Vomiting , Swelling , Cotton Wool, Cotton Bandage , Surgical Sprit etc placed in a wall mounting box with 6mm thick front hinged glass cover, with the sign " +" and the inscription "FIRST AID" in Red Paint - Overall size not less than 450mm x 300mm x 200mm deep in two tier shelf pattern.
Providing and fixing of 4.5kg. capacity I.S.I. Marked. (IS : 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.
Sabtech Engineering Works
HUBBI ELECTRICALS
Powermech Engineering Services
M/S BCON
stage.html
html • 0.02 MB
finance_386229.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .