Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | ₹26.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹26.6 L+₹33,369 (1.27%)Rejected-Finance | ₹26.6 L+₹33,369 (1.27%) | L2 | Rejected-Finance L2 |
| 3 | L3₹30.8 L+₹4.5 L (17.3%)Rejected-Finance | ₹30.8 L+₹4.5 L (17.3%) | L3 | Rejected-Finance L3 |
| 4 | L4₹34.3 L+₹8.1 L (30.9%)Rejected-Finance X 125 NEW ROSHANPURA SHAHEED RAJESH GILL MARG NAJAFGARH SOUTH WEST DELHI DELHI 110043 UDYAM DL 10 0019190 06AADCJ2143B1Z8 B 07AADCJ2143B1Z6 R MSME STATUS AS VERIFIED | WEST DELHI | DELHI | 110043 | ₹34.3 L+₹8.1 L (30.9%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Conditional Tender not acceptable therefore Technically Disqualified |
Tender Value
₹37.9 L
EMD Value
₹76,000
Closing Date
17 May 2023, 12:00 pmClosed
Principal Hansraj College
Hansraj College University of Delhi
As per tender document
2023_DU_751464_1
HRC/Build/Tender/2023-24/01
Open Tender
Civil Works
Works
45 days
Hansraj College University of Delhi
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Principal Hansraj College
₹76,000
Yes
Hansraj College University of Delhi
4 Jul 2023
3 May 2023
18 May 2023
3 May 2023
17 May 2023
3 May 2023
12 May 2023
Amount
VRV HVAC Works
ITC of VRV Variable refrigerant Volume modular type outdoor units equipped with highly efficient inverter type compressor(s) , air coolled condenser with special precoated fins type heat exchanger and direct drive low noise propeller fan system suitable for heating / Cooling.Indoor and outdoor units complete as per quantity given below. Electrical equipments suitable 415V 50Hz power supply. Inclusive of Stand. Outdoor Units.
Installation and gas charging - first charge refrigerant (R-410A or equivalent) with lubricating oil.
SITC of Indoor Units (Nominal Capacity).
Slim type Indoor Unit with fittings equipped with pre- filter, fan section with low noise fan and multispeed motor, drain pump complete as reqd. (Including Corded Remote & Refnets). Vendor to supply shop drawings before starting the works
FXAQ40ARVE6
FXAQ63ARVE6
FXAQ50ARVE6
SITC of Wired Remotes including fixing on the wall.
Refrigerant Piping
SITC of interconnecting following sizes of refrigerant copper pipe work refnets, Nitogen pressure testing, Vacuumising, insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units properly fixed/support with suitable size of clamp /M.S. hanger as reqd.
34.9 mm O.D (insulation -19mm thick)
28.6mm O.D (insulation -19mm thick)
22.2mm O.D (insulation -19mm thick)
19.1mm O.D (insulation -13mm thick)
15.9mm O.D (insulation -13mm thick)
12.7mm O.D (insulation -13mm thick)
9.5 mm O.D (insulation -13mm thick)
6.4mm O.D (insulation -13mm thick)
SITC of Covered GSS Cable Tray of suitable size for exposed piping . 300 mm width
Drain Piping
SITC of Rigid PVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber.
25 mm dia
Electrical
Electrical Panel For Supply to OD Units.
Design, fabrication, assembling, wiring, supply, testing at works, packaging, forwarding to site, installation, testing & commissioning of Main LTcum synchronizing panel /Main distribution panels / sub-distribution panels, fabricated out of 14 gauge CRCA sheet steel in cubicle formation, compartmentalized, from 3b consutruction, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 16 gauge CRCA sheet steel shall be used for final distribution panels. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 No. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. Fabrication size shall be as site conditions. Note:- ( Job is including all wo including the cost of connection, cable,all fixture/fitting) ( MAKE:- L&T)
315 Amps 4 pole MCCB with following accessories:
Phase indicating light shall be protected by 2 Amps SP MCB's. - 1 Set
500 Amps TPN Aluminiun bus bars with heat coloured shrinkable insulation sleeve. - 1 Set
25 Amps 4 pole MCCB. 10 Nos +2 Spare
63 Amps 4 pole MCCB. 2 Nos
40 Amps 4 pole MCCB. 2 Nos
Providing & fixing / Laying AL. Cable 4 core 150Sqmm
Providing & fixing control cum transmission wiring in Heavy Duty PVC 20/25 mm conduit buried in wall or in suitable surface, between indoor units and outdoor units.
2 Core x 1.5 Sqmm Copper wire/Cable
4 Core x 10 Sqmm Copper wire/Cable
Isolator with weather proof box (25A to 63A)
Supply of VRV Variable refrigerant Volume modular type outdoor units equipped with highly efficient inverter type compressor(s) , air coolled condenser with special precoated fins type heat exchanger and direct drive low noise propeller fan system suitable for heating / Cooling.Indoor and outdoor units complete as per quantity given below. Electrical equipments suitable 415V 50Hz power supply. Including stands etc.
Outdoor Units.
10 HP Top discharge
SITC of Indoor Units (Nominal Capacity) (Including Corded Remote & Refnets
Slim type Indoor Unit with fittings equipped with pre- filter, fan section with low noise fan and multispeed motor, drain pump complete as reqd. (Including Corded Remote & Refnets). Vendor to supply shop drawings before starting the works
FXAQ40ARVE6
FXAQ63ARVE6
FXAQ50ARVE6
Refnets
SITC of Wireless Remotes
Twinning Kit
Leakage testing of copper pipe with Nitrongen and cleaning of copper pipe with CTC Chemical for future carbon issues that will occour in commissioning stage. Addressing of copper pipe and drain pipe & make the existing copper pipe in working condition.( Note:- Contractor should visit the site before quoting this item.)
Xavient Solutech
Reliable Furnishers
JUHI AND JAI CONTRACTORS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .