Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.7 L+₹75,670 (4.73%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹16.9 L+₹89,500 (5.60%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹18.3 L+₹2.3 L (14.5%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹20.3 L+₹4.3 L (27.0%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L5 | Rejected-Finance other than lowest |
Tender Value
₹27.2 L
EMD Value
₹54,320
Closing Date
12 Jul 2024, 6:00 pmClosed
CWE NEW CWE NEW DELHI
CWE NEW DELHI-10
REPAIR/ MAINT OF PACKAGE TYPE DUCTABLE AIR CONDITIONING PLANT OF VARIOUS CAPACITIES, VRG ACs, AHUs, LT PANEL BOARDS (AC) AND VARIOUS TYPE OF ALLIED WORKS AT AHRR UNDER GE E/M RR HOSP, DELHI CANTT-10
2024_MES_658925_1
CWE/ND-10/2024-25
Open Tender
Civil Works - Others
Item Rate
120 days
RR HOSPITAL NEW DELHI
refer tender
9 documents required · 9 mandatory
₹500
GE RR HOSPITAL
₹54,320
Yes
11 Sept 2024
11 Jun 2024
15 Jul 2024
11 Jun 2024
12 Jul 2024
27 Jun 2024
Amount
Material and labour for servicing of outdoor VRF ACs capacity 12 HP (Dental New building) as per OEM(Voltas) direction with the help of Pressure Booster Pump along with chemical removing front PVC grills, air filters, cleaning, washing, removing dirt and including checking power connection .cleaning / wash of cooling coil of outdoor cooling unit and condenser coil of out door unit and re-assembling the dismantled components of its original position complete all as directed by Engr-in-Charge.
Material and labour for servicing of out door VRF ACs capacity 10HP (Dental New building) as per OEM (Voltas) direction with the help of Pressure Booster Pump along with chemical removing front PVC grills, air filters, cleaning, washing, removing dirt and including checking power connection .cheleaning / wash of cooling coil of outdoor cooling unit and condenser coil of out door unit and re-assembling the dismantled components of its original position complete all as directed by Engr-in-Charge.
Note - For ser item 1 and 2, during the contract period if more then one serviceing is required based cooling efficiency deemed in the quoted rate and time to time checkup for the healthy condition of instruments/equiptment are deemed to be included in quoted rate.Hard copy of servicing records should be deposit in this office before payment procedure.
Material and Labour for servicing of Cassette unit of various capacity with the help of Air pressure and chemical washing including cleaning of air filter refixing in its original position all as directed by Engr-in-Charge.
Material and labour for servicing of fan coil unit (FCU) with the help of chemical cleaning and Pressure booster pump all as directed by Engr-in -Charge.
Material and labour for Top up Gas Charging with R-407C for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
Material and labour for Top up Gas Charging with R-410 for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
Material and labour for Top up Gas Charging with R-404 for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
Calibration of VRF outdoor & indoor communication estabilishing (12 HP+10 HP) x4 circuit and all safety features all as directed by Engr-in-Charge.
S&F, in replacement of copper tubing of 3/8” dia suitable for VRF AC/Package type ACs as per existiong copper tube including brazing / cutting / bendinng all as specified and directed by Engr-in-Charge.
S&F, in replacement of copper tubing of 5/8” dia suitable for VRF AC/Package type ACs as per existiong copper tube including brazing / cutting / bendinng all as specified and directed by Engr-in-Charge.
M & L for servicing Air cooled scroll type chiller unit with multi compresor capaacity 15 TR to 30 TR ( -ART,JRC,BMT and Lab) as per direction of OEM (Bluestar)comprising with following works (a) cleaning the cooling ,condense coil with the help of Pressure Booster Pump recommended chemical and removing extra deposit material (b) Checking the helthly condition of compressor along with electric cable connection. (c) PCB should be original sitting as per OEM recommendation and checking all electric cable connection ,during the serviceing if any type of cable for connection in the chiller unit should be replaced by the contractor with out any cost effect .(e) During the serviceing if the required welding /brazing /nut/bolt and which are not mentioned in the schedule but necessary for serviceing or made functional should be repaced by the contractor with out financial effects , all as directed and specified by the Engr-in-Charge. Note - during the contract period if more then one serviceing is requited based cooling efficiency and time to time checkup for the helthy condition of instruments/equiptment are deemed in the quoted rate.
M&L for dismantling of electric driven horizontal induction motor of capacity 2 HP of any type and make, including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts if required i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
M&L for dismantling of electric driven horizontal induction motor of capacity 3 HP of any type and make, including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts if required i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
M&L for dismantling of electric driven horizontal induction motor of capacity 5 HP of any type and make, including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts if required i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
M&L for dismantling of electric driven horizontal induction motor of capacity 7.5 HP of any type and make, including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts if required i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
M&L for complete overhauling of condenser / chiller centrifugal pump set of 2 HP to 3.0 HP including disconnecting suction & discharge water lines and removing electric connection, dismantling the existing pump set from MS foundation, detaching the pump, opening the pump, remetaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump bodyreplacement of foot anti vibration pad and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc, checking the alignment, reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed. Note: including TPT,tools ,Item/ spare parts as per site requirment deemed in the quoted rate.
M&L for complete overhauling of condenser / chiller centrifugal pump set of 3.0 HP including disconnecting suction & discharge water lines and removing electric connection, dismantling the existing pump set from MS foundation, detaching the pump, opening the pump, remetaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump bodyreplacement of foot anti vibration pad and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc, checking the alignment, reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed. Note: including TPT,tools ,Item/ spare parts as per site requirment deemed in the quoted rate.
M&L for complete overhauling of condenser / chiller centrifugal pump set of 5.0 HP including disconnecting suction & discharge water lines and removing electric connection, dismantling the existing pump set from MS foundation, detaching the pump, opening the pump, remetaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump bodyreplacement of foot anti vibration pad and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc, checking the alignment, reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed. Note: including TPT,tools ,Item/ spare parts as per site requirment deemed in the quoted rate.
M&L for complete overhauling of condenser / chiller centrifugal pump set of 7.5 HP including disconnecting suction & discharge water lines and removing electric connection, dismantling the existing pump set from MS foundation, detaching the pump, opening the pump, remetaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump bodyreplacement of foot anti vibration pad and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc, checking the alignment, reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed. Note: including TPT,tools ,Item/ spare parts as per site requirment deemed in the quoted rate.
S&F, in replacement of control MCB, C Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
Supply & fixing in replacement, of MCB 32 Amp,4 pole, 10 KA, C Curve, complete all as directed.
Supply & fixing in replacement, of MCB 40 Amp,4 pole, 10 KA, C Curve, complete all as directed.
Supply & fixing in replacement, of MCB 63 Amp,4 pole, 10 KA, C Curve, complete all as directed.
Supply & fixing in replacement, of MCCB 63 Amp, 3 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
Supply & fixing in replacement, of MCCB 100 Amp, 4 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
Supply & fixing in replacement, of MCCB 160 Amp, 3 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
Supply & fixing in replacement, of MCCB 250 Amp, 4 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
Supply & fixing in replacement, of MCCB 400 Amps, 3 pole, Micro processor based with breaking capacity 36KA, Ics = 100% Icu, with adjustable natural pole protection ,Innovative front indication LEDs ,adjustable over load setting alongwith Spreader terminals and phase barriers complete all as specified and directed .
Supply and fix in replacement three pole power contactor capacity 32/40 Amps type MNX32/40 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
Supply and fix in replacement three pole power contactor capacity 25 Amps type MNX25 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
Supply and fix in replacement three pole power contactor capacity 18 Amps type MNX18 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
Supply and fix in replacement three pole power contactor capacity 12 Amps type MNX12 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
Supply and fix in replacement front mounting auxilary contact blocks for suitable contactor any description type 2NO+2NC (MNX/MCX) all as direction by Engr-in-Charge.
Supply & fixing in replacement of over load relay upto 3-5 Amps, direct / separate mounting on contactors, as required, and making all electric connection, complete all as directed.
Supply & fixing in replacement of over load relay range 9-15 Amps, direct / separate mounting on contactors, as required, and making all electric connection including, complete all as directed.
Supply & fixing In replacement of Star Delta electronic timer time delay 3 to 30 second as per existing size and all as directed by Engr -in Charge.
Supply & fixing in replacement of single phase preventor relay 415 V ,mode of operation Auto/Manual/Bypass, auto restrat with in 30 sec suitable for Star-delta strater incl taking down of unserviceable relay and making all electric connection, complete all as directed.
Supply & fixing in replacement of LED type indicator lamp of red/blue/green colour for phase indication, complete all as directed.
Supply & fixing in replacement of Start/Stop push button, projecting head (push function) type, complete all as directed.
Supply & fixing in replacement of current transformer of 30/5A,15 VA Class 1 burden, suitable to measuring current complete all as directed.
M & L in replacement for panel wiring in replacement of un-armoured 10 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
M & Lin replacement for panel wiring in replacement of un-armoured 6 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
M & L in replacement for panel wiring in replacement of un-armoured 1 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
Supply & fixing in replacement of connector of suitable for 16 Sq mm capacity for making electric connections in LT panel board, complete all as directed.
Supply & fixing in replacement of PVC channel for panel wiring complete all as directed by Engr- in- Charge.
M&L for applying one coat of synthetic enameled spray paint of existing colour on steel/iron surfaces(existing) of pipes, LT panel boards etc with and incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc complete all as directed.
S & F in replacement Sheet metal enclosure of size 600 mm X 450 mm X 300 mm made with the help of 2 mm thick CRCA Sheet suitable for MCCB /Star & Delta switch gear/relay etc,Switch gear should be hold on the shock proof hylam sheet of 2 mm thick , fornt door should be openable type holding with hinges and lock and key system for protection , start/ stop button and three phase indicator lamp including voltmeter/ameter approches or hole made on front door ,single phase MCB , busbar 200Amps Capacity . Note - fastener, nut and bolt /anchoring hook /drilling/colour painting deemed in the quoted rate and Switch gear should be measured and paid seperately .
S & F three phase VFD (Variable Frequency Drive ) 7.5 Hp to 15 Hp capacity compact type with micro processor suitable for controlling of motor speed working voltage 415 Volt,50 Hz including cable connection as per existing position and taking down old unserviceable one all as directed by Engr-in-Charge.
M&L for outdoor fan motor of suitable capacity 415 volt ,50 Hz for Package type AC's of capacity 22.5 TR by taking down old unserviceable motor all as directed by Engr-in-Charge
S& F in replacement scroll Compressor capacity 12 TR for package type ACs and taking down old unserviceable one complete as directed by Engineer-in-charge. Make: Danfoss(As per existing)
Supply and fix V-Belt suitable for 12000 CFM AHU including taking down u/s item all as directed by .
Supply and fix V-Belt suitable for 6000 CFM AHU including taking down u/s item all as directed by .
Supply and fix V-Belt suitable for 3000 CFM AHU including taking down u/s item all as directed by .
M&L for rewinding outdoor fan motor for package type AC 34 TR including fixing in the same position all as directed by Engr-in-charge.
S & F in replacement thermostatic expansion valve suitable for package type unit with 12 TR circuit complete all as specified and as directed.
S & F in replacement drier filter suitable for package type AC complete all as specified and as directed.
S&F in replacement water flow switch suitable for package type AC 22.5TR TR complete all as specified and as directed.
S&F in replacement water flow switch suitable for package type AC 34 TR complete all as specified and as directed.
S & F in replacement HP/LP switch suitable for package unit 22.5 TR complete all as specified and as directed.
S & F in replacement HP/LP switch suitable for package unit 34 TR complete all as specified and as directed.
S & F in replacement EWT/LWT sensor suitable for package unit 22.5/34 TR complete all as specified and as directed.
S & F in replacement AFT switch suitable for package unit 22/34 TR complete all as specified and as directed.
S&F in replacement condenser coil 3 row-deep suitable for package type unit 22.5TR including taking down old unserviceable coil complete all as specified and as directed.
Checking of leakage in chiller circuit of package type AC Plant 22.5/34 TR, with the help of full pressure of Nitrogen gas to check the leakage and repairing/blocking of leakage with the help of copper brazing or block the leakage pipe and testing of complete circuit system to the satisfaction of Engr-in-charge complete all as specified and directed. Note: Nitrogen gas required to check leakage is deemed to be included in quoted rates.
S & F PVC insulated LT XLPE armoured heavy duty electric cable 4 core with aluminium conductor,1100 volt grade cross-sectional area 10 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable all as specified and directed by Engr- in -Charge.
S & F PVC insulated LT XLPE armoured heavy duty electric cable 4 core with aluminium conductor,1100 volt grade cross-sectional area 16 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable all as specified and directed by Engr- in -Charge.
S & F PVC insulated LT XLPE armoured heavy duty electric cable 3.5 core with aluminium conductor,1100 volt grade cross-sectional area 25 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable all as specified and directed by Engr- in -Charge.
S & F in replacement compressor for VRF(Variable Refrigerant Flow) unit 12 HP including taking down old unserviceable compressor complete all as specified and as directed.
S & F in replacement compressor for VRF(Variable Refrigerant Flow) unit 10 HP including taking down old unserviceable compressor complete all as specified and as directed.
S&F PCB card of outdoor unit of 12/10 HP VRF unit including taking down old unserviceable PCB complete all as specified and as directed.
Calibration of chiller safety and electronic circuit by OEM or authorized dealer of OEM including checking all safety features i.e, all HP/LP switch, water flow switch, AFT switch with the help of multimeter, checking of electronic circuit plate (PCB) and find and rectify any fault in PCB and safety complete all as specified and as directed. Note: Any parts replaced or rectified shall be measured sepeartely
M&L for repair of PCB of package type unit 23TR/34TR by replacing whichever of the following parts is required to be changed i.e. capacitor, relay, optocoupler, microcontroller, resistor by taking out unserviceable complete all as specified and as directed.
S&F in replacement PCB card of air cooled package type unit (Bluestar) capacity 22.5/34 TR by taking down old unserviceable card and doing proper electrical connection and testing on completion complete all as specified and as directed.
S&F in replacement HMI display of air cooled package type unit (Bluestar) capacity 22.5/34 TR by taking down old unserviceable display and doing proper electrical connection and testing on completion complete all as specified and as directed.
S&F in replacement wall mounted Star delta Starter 7.5 HP 3 phase including overload relay, electronic timer, phase failure relay, start and stop push buttons, ON/OFF indication lamp, voltmeter and ammeter including electrical connection complete all as specified and as directed.
S&F in replacement wall mounted Star delta Starter 5 HP having overload relay, electronic timer, phase failure relay, start and stop push buttons, ON/OFF indication lamp, voltmeter and ammeter including electrical connection complete all as specified and as directed.
M&L for servicing of hot water generator suitable for package type AC 22.5/34 TR by checking all safety, heaters, electronic circuit plate including proper cleaning of control panel complete all as specified and as directed.
S&F in replacement 4 core communication cable of VRF AC 12/10 HP complete all as specified and as directed
DP Traders
Flint India
RUCHIKA ENGG.WORKS
SNOWY ENGINEERING INC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .