| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹32.5 L+₹69,205 (2.17%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.3 L+₹1.5 L (4.68%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹33.5 L+₹1.6 L (5.17%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹33.8 L+₹2.0 L (6.17%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
28 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITIONAL / ALTERATION TO ELECTRICAL DISTRIBUTION SYSTEM AT CG AREA UNDER GE HADDO
2021_MES_443304_1
8535/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
D b (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹84,000
Yes
1 Sept 2021
17 May 2021
30 Jun 2021
17 May 2021
28 Jun 2021
26 May 2021
17 May 2021 - 22 May 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. NOTE: 1. If new cable is laid as replacement of old cable in the same trench, all excavation and earth work shall be measured only once. 2. If any pipe is laid in trenches as cable protection, all excavation and earth work shall be measured either for cable or for pipe only and not for both. 3. If cable is laid in tiers and in loops, all excavation and earth work shall be measured accordingly.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings of poles/stays including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 70 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 95 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 120 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 240 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 300 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 400 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed. NOTE for all items of cable: 1. Cable test results like continuity test, megger test shall be submitted to Engr-in-charge before the cable is laid. 2. Necessary excavation and earth work shall be measured and paid separately under relevant items of this schedule.
M&L for HDPE DWC (Double wall corrugated) pipe of size 77mm (Outer diameter) x 63mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 120mm (Outer diameter) x 103.5mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for 100mm dia or bore galvanised steel tubing, medium grade for cable protection in road crossing including cutting of road and making good to match with the existing surface (OR) fixed on poles etc., including taking out old rusted GI pipes complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion including demolition of old unserviceable earth pit and taking out earthing material from pit complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
S&F Galvanised iron strip 32x6mm buried in ground or fixed to walls/poles with necessary clamps, bolts and nuts including taking down old unserviceable strip complete all as specified and as directed.
S&F Outdoor LT panel / LT pillar box of dimensions 2.4m x 1.3m x 0.5m size with following specifications. Fabrication Details : CPRI approved Main frame 3.0 mm thick CRCA sheet, partition sheets / covers / doors of 3.0 mm thick CRCA sheet, gland plates 3.0 mm thick MS sheet (undrilled), all over body front and back cover with hinges and aldrops for locking arrangements duly 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for bus bar cover panel partitions and bottom cable entry covers duly painted with one coat of red oxide and two coats of synthetic enamel paint with control wiring to complete LT panel with 2.5 Sqmm FRLS copper cable and 6 A MCB's, meters, indication lamps, base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP-65 and locking arrangements including taking down old unserviceable LT panel complete all as specified and as directed.
Bus bar details: Material shall be aluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 40x20mm aluminium flat, neutral 40x10mm aluminium flat and bus bar support of epoxy type. Painting Details : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer and marking of details of capacity/ rating/ incoming/ outgoing/ danger notice board in capital English alphabets with red colour radium sticker of required size. Accessories for Pillar Box: (i) 0-500V Digital voltmeter - 01 No (Flush type) (ii) 0-500A Digital Ammeter - 01 No (Flush type) and (iii) Indication Lamps (LED) RYB - Set of 03 Nos. MAKE: L&T / BINAY/ ELMEASURE
(iv) Incomer:- 400A, 4 pole, Change over switch Make:L&T, Cat No. CO44000OOOO -1 No. (v) Outgoing:- (a) 250A, 3 pole, MCCB, 36 KA Make: L&T, Cat No. CM98060OOO -2 Nos. (b) 125-160A, 3 pole, MCCB, 30KA Make: L&T, Cat No. CM90678OOLO -5 Nos. (c) 100A, 3 pole, MCCB, 10 KA Make: L&T, Cat No. CM98922OOOO -2 Nos. (d) 63A, 3 pole, MCCB, 30 KA Make: L&T, Cat No. CM97894OOJ2 -4 Nos. MAKES OF SWITCH GEAR: L&T (Cat part Nos. as given above) or equivalent in SCHNEIDER/ ABB NOTES: (i) All MCCBs are of adjustable overload 80 to 100% with thermal magnetic release Ics= 100% of Icu (ii) The unit rate quoted is deemed to include the cost of MCCBs, Volt meter, Ammeter, Indication lamps, Changeover switch and connected wiring with necessary spreader links, lugs, glands and connecting of cables as per site conditions and complete all as specified and as directed. (iii) The unit rate quoted deemed to include for cost of breaking the existing PCC foundation, if any and making good the disturbed surfaces to match with existing surfaces. (iv) Drawings must be approved by Engineer-in-Charge before fabrication of LT Panel.
S&F Out door LT panel / LT pillar box of dimensions 1.6m x 1.4m x 0.9m size with following specifications. Fabrication Details : CPRI approved Main frame 3.0 mm thick CRCA sheet, partition sheets / covers / doors of 3.0 mm thick CRCA sheet, gland plates 3.0 mm thick MS sheet (undrilled), all over body front and back cover with hinges and aldrops for locking arrangements duly 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for bus bar cover panel partitions and bottom cable entry covers duly painted with one coat of red oxide and two coats of synthetic enamel paint with control wiring to complete LT panel with 2.5 Sqmm FRLS copper cable and 6 A MCB's, meters, breaker control supply and indication lamps, base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP-65 and locking arrangements including taking down old unserviceable LT panel complete all as specified and as directed.
Bus bar details: Material shall be aluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 50x12mm aluminium flat, neutral 50x12mm aluminium flat and bus bar support of epoxy type. Painting Details : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer and marking of details of capacity/ rating/ incoming/ outgoing/ danger notice board in capital English alphabets with red colour radium sticker of required size. Accessories for Pillar Box: (i) 0-500V Digital voltmeter - 01 No (Flush type) (ii) 0-500A Digital Ammeter - 01 No (Flush type) and (iii) Indication Lamps (LED) RYB - Set of 03 Nos. MAKE: L&T / BINAY/ ELMEASURE
(iv) Incomer:- 400A, 4 pole, Change over switch Make:L&T, Cat No. CO44000OOOO -1 No. (v) Outgoing:- (a) 250A, 3 pole, MCCB, 36 KA Make: L&T, Cat No. CM98060OOO -3 Nos. (b) 125-160A, 3 pole, MCCB, 30KA Make: L&T, Cat No. CM90678OOLO -3 Nos. (vi) Astro timer switch for controlling street lights/post top lanterns/bollard lights Make: L&T, Cat No. AUTS02AST00 -1 No. MAKES OF SWITCH GEAR: L&T (Cat part Nos. as given above) or equivalent in SCHNEIDER/ ABB NOTES: (i) All MCCBs are of adjustable overload 80 to 100% with thermal magnetic release Ics= 100% of Icu (ii) The unit rate quoted is deemed to include the cost of MCCBs, Volt meter, Ammeter, Indication lamps, Timer switch, Changeover switch and connected wiring with necessary spreader links, lugs, glands and connecting of cables as per site conditions and complete all as specified and as directed. (iii) The unit rate quoted deemed to include for cost of breaking the existing PCC foundation, if any and making good the disturbed surfaces to match with existing surfaces. (iv) Drawings must be approved by Engineer-in-Charge before fabrication of LT Panel.
S&F Out door LT panel / LT pillar box of dimensions 1.6m x 1.4m x 0.9m size with following specifications. Fabrication Details : CPRI approved Main frame 3.0 mm thick CRCA sheet, partition sheets / covers / doors of 3.0 mm thick CRCA sheet, gland plates 3.0 mm thick MS sheet (undrilled), all over body front and back cover with hinges and aldrops for locking arrangements duly 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for bus bar cover panel partitions and bottom cable entry covers duly painted with one coat of red oxide and two coats of synthetic enamel paint with control wiring to complete LT panel with 2.5 Sqmm FRLS copper cable and 6 A MCB's, meters, breaker control supply and indication lamps, base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP-65 and locking arrangements including taking down old unserviceable LT panel complete all as specified and as directed.
Bus bar details: Material shall be aluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 50x12mm aluminium flat, neutral 50x12mm aluminium flat and bus bar support of epoxy type. Painting Details : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer and marking of details of capacity/ rating/ incoming/ outgoing/ danger notice board in capital English alphabets with red colour radium sticker of required size. Accessories for Pillar Box: (i) 0-500V Digital voltmeter - 01 No (Flush type) (ii) 0-500A Digital Ammeter - 01 No (Flush type) and (iii) Indication Lamps (LED) RYB - Set of 03 Nos. MAKE: L&T / BINAY/ ELMEASURE
(iv) Incomer:- 400A, 4 pole, Change over switch Make:L&T, Cat No. CO44000OOOO -1 No. (v) Outgoing:- (a) 250A, 3 pole, MCCB, 36 KA Make: L&T, Cat No. CM98060OOO -2 Nos. (b) 125-160A, 3 pole, MCCB, 30KA Make: L&T, Cat No. CM90678OOLO -4 Nos. (vi) Astro timer switch for controlling street lights/post top lanterns/bollard lights Make: L&T, Cat No. AUTS02AST00 -1 No. MAKES OF SWITCH GEAR: L&T (Cat part Nos. as given above) or equivalent in SCHNEIDER/ ABB NOTES: (i) All MCCBs are of adjustable overload 80 to 100% with thermal magnetic release Ics= 100% of Icu (ii) The unit rate quoted is deemed to include the cost of MCCBs, Volt meter, Ammeter, Indication lamps, Timer switch, Changeover switch and connected wiring with necessary spreader links, lugs, glands and connecting of cables as per site conditions and complete all as specified and as directed. (iii) The unit rate quoted deemed to include for cost of breaking the existing PCC foundation, if any and making good the disturbed surfaces to match with existing surfaces. (iv) Drawings must be approved by Engineer-in-Charge before fabrication of LT Panel.
Sree Tirumala Enterprises
SKV Engineering
SRI HARSHITA ELECTRICALS
bansal construction
SMS Engineering Corporation
OPS Associates
SACKSON ENTERPRISES
ISLAND SALES ENTERPRISES
M/S R R ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .