Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.7 L+₹8.0 L (23.9%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹46.4 L+₹12.8 L (38.0%)Rejected-Finance | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹49.4 L+₹15.8 L (47.0%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹50.6 L+₹17.0 L (50.6%)Rejected-Finance TRIVANDRUM | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
20 Jan 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT MAINTENANCE OF UPS SOLAR STREET LIGHT FITTINGS SOLAR PANEL AND MAINTENANCE OF DG SETS AND SMOKE CHIMNEY AT INHS ASVINI UNDER AGE I ASVINI COLABA MUMBAI
2023_MES_633309_1
8031/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
AGE (I) Asvini
Class C Category b(i)
7 documents required · 7 mandatory
₹1,000
Yes
AGE (I) Asvini
₹1.1 L
Yes
20 Mar 2024
18 Dec 2023
22 Jan 2024
18 Dec 2023
20 Jan 2024
8 Jan 2024
18 Dec 2023 - 1 Jan 2024
Amount
Comprehensive maintenance of UPS system upto 3 KVA capacity -9 Nos of any make including attending fault /complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i). The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 visits shall be made by the technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 3.5 KVA to 6.25 KVA capacity -12 Nos of any make including attending fault /complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i). The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 visits shall be made by the technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 20 KVA capacity - 1 No of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic partsas per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 visits shall be made by the technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 30 KVA capacity - 1 No of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 visits shall be made by the technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 40 KVA capacity - 1 No of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make installed at Bldg INDS as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 visits shall be made by the technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance/cleaning of solar panels having efficiency around 20.1% of capacity 9 KW compleate with 150 AH battery 18 nos 3.5 KVA solar inverter 03 nos of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e connector, leads , LED lamps, minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 visits shall be made by the technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Supply and fixing in repairs Commercial UPS system 5.2 KVA capacity, Sine wave, Rated out put power -4420watts, Maximum charging current -21 Amperes, Max VA rating - 3501VA to 5500 VA, Protection - deep discharge, MCB, Over load, shortcircuits, Features - digital display, fast charging, easy UPS bypass, Net Weight - 44.5 Kgs, complete system and testing after replacement to the satisfaction of Engineer-in-Charge .
Supply and fixing in repairs solar panel size 1656mm x 991mm x 40mm, 270Wp, 12/24volt, Max voltage power -31.5 Vmp(V), Max current power- 8.57 Imp (A), testing after replacement to the satisfaction of Engineer-in-Charge.
Supply and fixing in repairs solar panel size 600mm x 450mm x 40mm, 40Wp, 12volt, Max voltage power -21.5 Vmp(V), Max current power- 2.48 Imp (A), testing after replacement to the satisfaction of Engineer-in-Charge . Make:- Luminous or Equivalent of make as specified in Appendix B
Supply and fixing in repairs UPS battery 12 Volts, 7.2 AH Capacity, sealed maintenance free and uninteruppted life complete all as specified and as directed. Make:- Amaron Quanta or Equivalent of make as specified in Appendix B
Supply and fixing in repairs UPS battery 12 Volts, 18 AH Capacity, sealed maintenance free and uninteruppted life complete all as specified and as directed. Make:- Amaron Quanta or Equivalent of make as specified in Appendix B
Supply and fixing in repairs UPS battery 12 Volts, 26 AH Capacity, sealed maitnenance free and uninteruppted life complete all as specified and as directed. Make:- Amaron Quanta or Equivalent of make as specified in Appendix B
Supply and fixing in repairs UPS battery 12 Volts, 42 AH Capacity, sealed maitnenance free and uninteruppted life complete all as specified and as directed. Make:- Amaron Quanta or Equivalent of make as specified in Appendix B
Supply and fixing in repairs solar charging battery 12 Volts, 150 AH Capacity, red charge RC 18000 tall tubular battery, long back up and low maintenance, filled height -503 x 189 x 41, complete all as specified and as directed. Make:- Luminous RC 180000 or Equivalent of make as specified in Appendix B
Supply and fixing in repairs Lead acid Battery 12 Volts, 150 AH Capacity, Inverlast tall tubular battery, High life and low maintenance complete all as specified and as directed. Make:- Luminous Model No. ILTT 180478 or Equivalent of make as specified in Appendix B
Supply and fixing in repairs FRP solar street light battery box 5mm thickness, black colour, weight upto 5Kgs, fixed to pole with clamp made out of MS flat 25x5 mm duly painted with one coat of red oxide and two coats of silver paint t complete all as specified. Make: RK Solar system or Equivalent of make as specified in Appendix B
Supply and fixing in repairs Solar LED standalone street light 45 Watts, system volt -24 Volt, Lumens- 4725Lumen, Maximum power point tracking control with in built SCC, SPV Panel - 200wp (100 x 2 Nos), Low maintenance lead acid tubular battery-120AH (2 x 60AH), Hot Dip Galvanized tubular pole length - 6 mtr above ground level with base plate and clamps including complete all accessories, Pole/box with clamp duly painted with one coat of red oxide and two coats of Syntheticenamel paint blue/silver colour complete all as specified. Note:- Earth work and PCC foundation shall be measured and paid separately.
Supply and fixing in repairs Mild steel solar street light battery box 5mm to 10mm thickness, surface finished, rectangular shape, single phase, weight - upto10Kgs, fixed to pole with MS clamp 25x5 mm duly painted with one coat of red oxide and two coats of synthetic enamel paint blue/silver colour to MS box and MS clamp complete all as specified.
Taking down carefully street light/ flood light fittings for repair/replacement of any capacity from 40-200 W and refixing the same after all repair work complete all as specified and directed by Engr-in-charge. Note: Spares shall be measured and paid separately.
Supply only LED driver of 40/45 W LED Street light/Post top/Flood light fitting.
Supply only LED driver of 60/72 W LED Street light/Flood light fitting.
Supply only LED driver of 90 W LED Street light/Flood light fitting.
Supply only LED driver of 100 W LED Flood light fitting.
Supply only LED driver of 160 W LED Flood light fitting.
Supply only LED driver of 200 W LED Flood light fitting.
Supply and fixing in repairs PVC insulated sheathed multistranded flexible copper conductor cable size 2.5 sqmm x 3 core, drawn through existing conduit / pipe from junction box to fitting complete all as specified and directed by Engr-in-charge
Supply, laying, commissioning and testing XLPE insulated screened, PVC inner sheathed galvanised steel strip or wire armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm x 4 core including taking down existing cable complete all as specified and directed by Engr-in-charge
Supply, laying, commissioning and testing XLPE insulated screened, PVC inner sheathed galvanised steel strip or wire armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm x 4 core including taking down existing cable complete all as specified and directed by Engr-in-charge
Supply, laying, commissioning and testing XLPE insulated screened, PVC inner sheathed galvanised steel strip or wire armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm x 4 core including taking down existing cable complete all as specified and directed by Engr-in-charge
Supply, laying, commissioning and testing XLPE insulated screened, PVC inner sheathed galvanised steel strip or wire armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm x 2 core including taking down existing cable complete all as specified and directed by Engr-in-charge
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables and getting out in any type of soil complete all as specified and directed by Engr-in-charge
Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge
Removing excavated materials (soils) outside MD land complete all as specified and directed by Engr-in-charge Note: The place of disposal shall be found out by the contractor.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed by Engr-in- Charge Note :- Only compacted thickness of sand will be measured and paid .
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and directed by Engr-in-charge
Cutting existing road surfaces or hard standing 450 mm wide and 450 mm depth (22 thick comprising bituminuous topping) for laying of pipes/cables and filling, compacting and making good disturbed surfaces as per existing surfaces complete all as specified and directed by Engr-in-charge
S&F in repairs 50mm High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface complete all as specified and directed by Engr-in-charge
S&F in repairs 100mm High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface complete all as specified and directed by Engr-in-charge
S&F in repairs GI pipe, light grade 40mm bore in road crossing for cable protection or above ground surface complete all as specified and directed by Engr-in-charge
M&L for Solar street light Hot Dip Galvanized tubular poles 80mm dia complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified (7.5 meter Long) and applying one coat of red oxide zinc chrome primer and two coats of aluminium paint and marking pole ser number as per existing number including taking out old corroded/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge.
M&L for Post top lantern GI tubular poles 50mm dia, 5 meter Long and applying one coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (black colour) and marking pole ser number as per existing number including taking out old corroded/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge.
M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified and directed by Engr-in-charge
M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in coping for steel pole including necessary formwork complete all as specified and directed by Engr-in-charge
S&F in repairs street light bracket bend to shape made as required of 40mm bore, 1 mtr long GI pipe light grade fixed to pole/ Wall with flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting and making all electric connection including taking out old bracket complete all as specified and directed by Engr-in-charge
M&L for Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and applying one coat of red oxide zinc chrome primer and two coats of aluminium paint (for supporting frame for flood light fitting) complete all as specified and directed by Engr-in-charge
M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metre Long) and applying one coat of red oxide zinc chrome primer and two coats of aluminium paint and pole ser number as per existing number including taking out old unserviceable/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge.
M&L for removing old paint by scraping from Steel/HDG tubular poles 5 to7.5 mtr length above ground level including street light arms ansd applying one coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (post top lantern to apply black colour and Solar street light pole to apply blue colour) and marking of pole numbers serially with 60 mm circle yellow base sticker and pole serial no written with radium letter in white colour, 150 cm above benching of pole complete all as directed by Engineer-in-Charge.
Supply and fixing in repairs PVC insulated and sheathed stranded copper conductor cable of size 2 x 2.5sqmm + 1 x 1.5sqmm 1100 Volts grade connecting from FRP type looping box to street light fitting connector, passing through steel tubular pole complete with fixing arrangement complete all as specified and directed.
Supply and fixing in repairs junction box made from FRP sheet ready made of size 300x200x110 mm including connector blocks four way having suitable size bolt to connect upto 35 sqmm x 3.5 core cable two Nos with the help of suitable gland, thimble nuts, washers supports by flat aluminium clamps not less than 25 mm x 3mm with suitable size nuts, bolts and washers inside and outside looping box including fixing with electric pole complete all as specified and directed.
Supply and fixing in repairs MCB TPN 32 Amp 10 kA, 415 V, 50 Hz, AC complete all as specified and directed by Engr-in-charge Make: Legrand Cat No. 4086 80 or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs MCB TPN 63 Amp 10 kA, 415 V, 50 Hz, AC complete all as specified and directed. Make: Legrand Cat No. 4086 83 or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs Timer switch 3 phase, 63 Amps capacity including power contactor with all accessories suitable for existing complete all as specified and directed.. Make :- (a) Timer switch - Legrand, Cat No 649915, MaxiRex 4QT or equivalent make as specified in Appendix B to PS -1 No. (b) Power contactor - Legrand, Cat No 412544, Nominal rating 25A or equivalent make as specified in Appendix B to PS - 2 Nos.
Supply and fixing in repairs LED Flood light fitting 150 watts luminaries with secondary optics made in pressure die-cast housing and heat sink in aluminium extrusion with IP66, complete all as specified and directed. Make:- Bajaj Cat No-PRAZE F 180L WH NB A5 TG SD or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs LED street light 120watts luminaries with secondary optics made in pressure die-cast housing and heat sink in aluminium extrusion with IP66, complete all as specified and directed. Make:- Bajaj Cat No-ZELA P 144L WH PO TG SD or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs LED Post top lantern 40 watts made in cast aluminium with decorative opal polycarbonate diffuser with IP65 protection, complete all as specified and directed. Make:- Bajaj Celesta Cat No- BGCL 40W LED WH or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs LED Post top lantern made in cast aluminium 25 Watt with decorative clear opal acrylic diffuser with IP65 protection, complete all as specified and directed. Make:- Bajaj Arian Cat No- BGCTN 25 W LED WW or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs LED Post top lantern 45 watts made in cast aluminium with innovative glare free indirect lighting distribution and IP65 protection, complete all as specified and directed. Make:- Bajaj Arian Cat No- BGCTN 45W LED WW or equivalent make as specified in Appendix B to PS
Supply and fixing in repairs 9 W LED Bollard offers a high level of durability with high impact resistance. It is easy to install, comes with ingress protection and provides compartable soft lighting complete all as specified and directed. Make:- BAJAJ TETRIS Bollard Cat No- BGBOS 650 9W LED WW or equivalent make as specified in Appendix B to PS
Material and Labour for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in earth pit with XPM not less than 4Kg per Sqm and Earthpit with cover including excavation and earthwork in any type of soil ,returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation of earthpit to mach existing surfaces after taking out old/unserviceable earthing and testing on completion all as specified and directed by Engr-in-Charge.
Material and Labour for Galvanised iron strip 32 x 6mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable strip complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs test point terminal block for connecting the earth pit and down conductor or Aluminium strip, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and directed by Engineer-in-Charge.
Comprehensive maintenance and Material and Labour for over hauling of HOT Crane, of 5 ton capacity of bay length 80.0 metres, span 20.0 metres and height of lift 4.0 metres from floor level, situated at AC Plant/ DG Set room to carryimg out monthly maintenance for renewal of unserviceable gears, oiling and greasing the chain pulleys etc, including load test verticality test and deflection test complete all as specified and as directed. NOTE: (a) All miscellaneous items required for satisfactory completion of the job deemed to be included in the unit rate quoted. (b) The contractor has to employ minimum one experienced and trained electrician having full knowledge on cranes and one helper to carry out the regular maintenance once in a month for smooth and effective functioning of Cranes and the cost deemed to be included in the unit rate quoted by the contractor. (c) Technician is responsible for cleaning and maintenance for HOT cranes under monthly maintenance. (d) Necessary tools & plants like ladder etc., required to attend the break down if any, shall be provided by the contractor and the cost is deemed to include in the unit rate quoted. (e) The contractor should submit the identity proof of Technician/Person visiting the site and also responsible for the integrity of the personnel attending the break down and monthly visits. (f) Full load test with 10% over load to be carried out once in the currency of the contract and the rates will be measured and paid under respective item accordingly.
Supply and fixing in repairs MS chain pulley block 5.0 ton capacity, standard lift-9Mtr, lift speed 2-8mtr/min suitable for HOT crane 5.0 Ton complete all as specified and as directed.
Supply & fixing in repairs fan belt of existing size and capacity suitable for 1000KVA DG set complete all as directed by the Engineer-in-Charge. Make : Fenner/LUCAS/TVS.
Disconnecting & removing carefully unserviceable diesel filter from 1000KVA DG set and Supply & Fix new diesel filter assembly suitable for 1000KVA DG set including cleaning filter cell, fixing filter element with new rubber gasket complete all as directed by the Engineer-in-Charge. Make: MICO/Puralator/Bosch.
Disconnecting & removing carefully unserviceable diesel filter from 62.5/40KVA DG set and Supply & Fix new diesel filter assembly suitable for 62.5/40 KVA DG set including cleaninng filter cell, fixing filter element with new rubber gasket complete all as directed by the Engineer-in-Charge. Make: MICO/Puralator/Bosch.
Disconnecting & removing carefully unserviceable oil filter from 1000KVA DG set and Supply & Fix new oil filter assembly suitable for 1000KVA DG set including cleaning filter cell, fixing filter element with new rubber gasket complete all as directed by the Engineer-in-Charge. Make: MICO/Puralator/Bosch.
Disconnecting & removing carefully unserviceable oil filter from 62.5/40KVA DG set and Supply & Fix new oil filter assembly suitable for 62.5/40KVA DG set including cleaning filter cell, fixing filter element with new rubber gasket complete all as directed by the Engineer-in-Charge. Make: MICO/Puralator/Bosch.
Disconnecting & removing carefully unserviceable air filter from 1000KVA DG set and Supply & Fix new air assembly suitable for 1000KVA DG set including cleaning filter cell, fixing filter element with new rubber gasket complete all as directed by the Engineer-in-Charge. Make: MICO/Puralator/Bosch.
Disconnecting & removing carefully unserviceable air filter from 62.5/40KVA DG set and Supply & Fix new air assembly suitable for 62.5/40KVA DG set including cleaning filter cell, fixing filter element with new rubber gasket complete all as directed by the Engineer-in-Charge. Make: MICO/Puralator/Bosch.
Supply and filling Engine oil 20W 40 complete all as directed by the Engineer-in-Charge. Make: Castrol GTX/Greaves Max therm/Kirloskar.
Supply and fixing in repairs electronic speed control unit with necessary connection terminal suitable for 1000KVA DG sets complete all as directed by the Engineer-in-Charge. Make : Kirloskar /Greaves.
Taking down u/s automatic voltage regulator, supply and fixing new regulator with UVN, PQ, F1F2 terminals rated voltage upto 180 Volts suitable for 1000KVA DG sets complete all as directed by the Engineer-in-Charge. Make : Kirloskar/Greaves/ Castrol.
Taking down u/s automatic voltage regulator, supply and fixing new regulator with UVN, PQ, F1F2 terminals rated voltage upto 180 Volts suitable for 62.5KVA DG sets complete all as directed by the Engineer-in-Charge. Make : Kirloskar/Greaves/ Castrol.
Supply and topping up of coolant. Make: castrol/ Veedol.
Supply and fix in repairs battery charging unit of capacity suitable for 12/24 volts battery and fixing inside the AMF panel enclosure complete all as specified.
Supply and fixing in repairs fuel/oil pipe lines (High pressure ruber pipe with benjo bolt covered with steel armoured specified.
Taking down carefully self starter assembly from engine for repairs and servicing of starter assembly including replacement of worn out parts complete all as specified. Note : Spare parts required shall be measured and paid separately under relevant items of this schedule.
Supply only Soleniod switch any type for self starter.
Supply only Carbon brush set any type with brush holder.
Supply only Drive End Plunger.
M&L for rewinding of field coils with existing gauge super enamelled copper wire complete all as specified.
Supply and fixing in repairs unserviceable Lead acid Battery 12 Volts, 180/200AH Capacity, Inverlast tall tubular battery, Super long backup and super long life complete all as specified and as directed. Make:- Luminous/Exide/Emerson.
Supply and fill in the batteries of DG sets distilled water and acid mix water at different locations complete all as specified and as directed.
Supply and fixing Engine control/protection relay having the auto manual mode, contactor close/open, DG start/stop functions suitable for 1000KVA capacity DG sets including taking down u/s protection relay complete all as specified and as directed. Make:- L&T,C&S,Siemens.
Supply and fixing in repairs injector over flow pipe as er existing complete all as specified and as directed.
Taking down dynamo assembly from engine for repair/replacement of worn out parts and refixing the same including cheking of proper charging of batteries complete all as directed.
Supply and fixing in repairs non return benjo bolt as per existing make complete all as directed.
Material and labour for dismantling/ opening carefully injectors DG set engine and transporting to the authorised dealer / workshop for servicing including replacement of injector nozzles and "O" rings and testing & calibration on bench after completion and transporting back to the place and refixing the same at the DG set engine.
Material and labour for dismantling /opening carefully fuel injection pump for calibaration and tesing on bench from authorised dealer / workshop and refixing the same after calibaration including transportation complete all as spcified.
Disconnection and removing the defective wiring from AMF Panels of any capacity and rewiring the same with copper wire of existing size,gauge and make including replacement of electrical/ electronic parts of AMF panel such as timers, contactors, Overload relays ,Micro prossser control Systems etc. for DG Set of capacity 1000/1500KVA, complete all as directed by Engr-in-charge.
Supply and fixing Auxilary Contactors (Existing type) with logic units. Make:- L&T/ Siemens/C&S.
Supply and fix in repairs unserviceable fuel feed pump .
M&L for removing old rusted paint from complete DG Set surfaces of the 1000 KVA capacity & AMF/DG panel complete and applying one coat of red oxide zinc chrome primer and two coats of synthetic enamel paint by spray painting including writing Ser No of DG set complete all as specified and directed.
Supply and fix in repairs unserviceable Radiator rubber hoses for 1000KVA DG set
Supply and fix in repairs unserviceable Clamp hump hose for 1000KVA DG set
Supply and fix in repairs unserviceable Hose clamps for 1000KVA DG set
Supply and fix in repairs unserviceable Hump hose for 1000KVA DG set
Material and labour for drain out the fuel tank of DG set of capacity 1000 Ltrs and above and keeping it in separate container Disconnectingg all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including applying one coat of black synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe protected with steel flexible pipe calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements omplete all as directed by Engr-in-charge.
Supply & fixing in repairs engine oil control pressure switch suitable for 1000 KVA DG set complete all as directed by Engr-in-charge.. Make- Kirloskar- Cummins or equivalent as specified in Appendix B to PS.
Material and Labour for dismantling of exhaust pipe of the 1000KVA DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engr- in- Charge.
Material and labour for Complete opening/ dismantling of chimney hood, smoke duct by removing rusted nut bolts, supports,angles,clamps,brackets,anchor fasteners, washers etc. Cleaning of complete hood, smoke duct by removing deposited dust particles, ash, smoke, oil by means of cleaning agent, replacement of new nut, bolt, washers aluminium filter, aluminium sheet of existing gauge and size, oiling, greasing of nut, bolt, washers and all joints,replacement of worn out smoke duct clothing ,maintenance of blower fan and motor including painting with heat resistant aluminium paint complete all as directed by Engr- in- Charge.
Taking down carefully blower motor for rewinding with suitable guage, insulating, drying, reinstalling, testing and commissioning of electric blower of capacity 7.5 HP, 3 phase, 240 volts, AC including electrical connection complete all as directed by Engineer-in-charge .
Supply and fixing in repairs MU- Automatic DOL starter for 3 phase, 415 volts, 50 Hz , AC Supply , suitable for 7.5 HP motor complete all as directed by Engineer-in-charge.
SHRI SAI ENTERPRISES
NOEL ENGINEERS
SHREE JAGDISH FURNITURE CO.
Vandan Enterprises
AGRAWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .