Tender Value
₹25.4 L
EMD Value
₹50,700
Closing Date
13 Aug 2026, 4:00 pmClosed
Ex. Engineer RnB Electric Hospital Division Kmr
Rajbagh Srinagar
SITC of Smart Racks at SKIMS MCH Bemina
2026_PWDJK_319014_1
eNIT No. HDE 25 of 2026_27 dated 01_08_2026
Open Tender
Network /Communication Equipments
Percentage
60 days
SKIMS MCH Bemina Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Ex. Engineer RnB Electric Hospital Division Kmr
₹50,700
Ex. Engineer RnB Electric Hospital Division Sgr
18 Aug 2026
1 Aug 2026
14 Aug 2026
1 Aug 2026
13 Aug 2026
1 Aug 2026
5 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of | - | - | - | - |
| 2 | Smart Rack
Individual modular racks should be of 48U (Height-Min) × 800 mm (Width-Min) × 1200 mm (Depth-Min). Overall depth of the setup should not be more than 1200 mm. All-steel construction rack with an integral base frame should have the following features: UDL Carrying Capacity: Minimum 1000 kg. Provision for Grouting: Racks shall have provision for grouting at site as required. Space Management: Efficient space management inside the rack ensuring maximum usable space. Similar space shall be available at the rear of the rack to facilitate proper and efficient airflow. Equipment Mounting Space: Minimum 44U equipment mounting space shall be available in each rack. 19" Mounting Rails: Rails shall be provided with U Identification Numbers clearly visible even after mounting of equipment. Rack Doors: All rack doors shall be easily removable to facilitate installation and service activities. Side Panels: Side panels shall be fully secured. Locking System: Industry-standard swing handle multi-point locking with Digital Locking shall be provided. The locks shall electronically confirm locking status with local LED indication and remote monitoring capability. EM (Electro-magnetic) Locks or Solenoid-type Locks shall not be used for the rack-based access control solution. Rack Colour: Shall be customized as per customer requirements. Branding: Required entity branding shall be provided as per customer requirements. ( Client emblem/logo/badge to be engraved on the front face of the Rack )
Contd... | - | - | - | - |
| 3 | Cooling Capacity
Solution provided should have an Integrated Rack Bottom Mounted (4U) Self-contained Split Type Cooling Unit, designed for cooling the racks during 24×7 operations, complying with ISHRAE/ASHRAE standards, and integrated with a Remote Monitoring System. Cooling Capacity: Minimum 3.5 kW × 1 No. for a Single Rack Micro DC. The cooling unit shall not consume more than 4U of rack space. Fans: High-efficiency EC Fans shall be used and shall be site-replaceable for ease of servicing. Variable speed operation shall be implemented in accordance with industry best practices. Scalability: The cooling unit shall support future cooling capacity enhancement up to 30% of the rated capacity, with the upgrade performed at site without disturbing the running setup. Design & Maintenance: Cooling unit design shall follow industry best practices, be user-friendly, and require minimal local expertise for maintenance. Monitoring: Power parameters and cooling conditions shall be monitored over IP. Day-1 Configuration: 3.5 kW Cooling Capacity × 1 Unit shall be provided on Day-1. Controller: Microprocessor-based controller supporting N+N Redundant Operation. HMI: Integrated HMI Display for local physical-level monitoring. Energy Monitoring: Power consumption of all cooling units shall be monitored separately and used to generate periodic Energy Efficiency Reports. Display Parameters: Power Parameters, Inlet Temperature, and Outlet Temperature shall be displayed on the top of the cooling unit for physical-level monitoring. Physical Design: Cooling unit height and depth shall match the rack dimensions, with aesthetics aligned to the rack design. Colour: Cooling unit colour shall be customized as per customer requirements.
Contd... | - | - | - | - |
| 4 | Cooling Type: Rack Bottom Mounted (4U) Self-contained Split Type Cooling Unit
Cooling Technology: Direct rack cooling with EC fans, microprocessor-based controller, remote IP monitoring, and future scalability up to 30% additional cooling capacity
Hot Aisle Containment: Optional
Cold Aisle Containment: Optional
VESDA System Ready: Fire Detection & Suppression: The system includes multi-sensor smoke detectors for early fire detection, an external suppression cylinder with zero rack space utilization, and a wall-mounted fire alarm panel with integrated alarms. It uses FK-5-1-12 as the suppression agent, ensuring safe and effective protection for critical IT equipment.
Contd... | - | - | - | - |
| 5 | Fire Alarm & Detection: Multi-sensor Smoke Detector shall be provided for early detection of fire within the rack environment. Fire Suppression: External Fire Suppression Cylinder with Zero U IT Rack Space Occupancy shall be provided to ensure no usable rack space is consumed. Fire Alarm Panel: Wall-mounted Fire Alarm Control Panel with integrated audible and visual alarm indications shall be provided for monitoring and control of the fire detection and suppression system. Suppression Agent: Clean Agent FK-5-1-12 shall be used for automatic fire suppression. The complete fire detection and suppression system shall be fully integrated with the rack monitoring solution for alarm, status, and event monitoring.
Contd... | - | - | - | - |
| 6 | Keyboard Tray: 1U Electric retractable keyboard tray.
Cable Manager: Following Rack Accessories should be included: - Blank Panels for closing the opening/gaps in the front mounting rails - Rack internal Cable Management for Vertical and Horizontal Cables - Front Panel Mounting Hardware - Brush Panel / Glands / Seals for all Cable Entry Points in the cabinet
Contd... | - | - | - | - |
| 7 | IP-based Biometric Access Control: Biometric Access Control shall be provided at every individual rack level. The integrated DC rack doors shall have digital locking to permit access only to authorized personnel through a fingerprint reader. The design shall comply with TIA-942 Guidelines. Access Control: The solution shall support multi-level access control and 4-Eye Principle authentication, requiring users to be authenticated at two levels. The system shall support remote door opening under administrative control during critical situations. Authentication: The biometric system shall support Biometric + Proximity Card (Prox Card) based authentication with an in-built controller, real-time IP monitoring, and remote door opening capability. Smart Card Reader: Proposed biometric system shall have a built-in Smart Card Reader. Integrated Camera: Proposed biometric system shall have a built-in camera to capture images of authorized and unauthorized users as part of event/data logs. Tamper Detection: The system shall generate a warning alarm in case of tampering. Scalability: The system shall support any number of user terminals over LAN/WAN. Connectivity Monitoring: The software shall continuously monitor terminal connectivity. Protection Rating: Biometric terminal shall be IP65, weatherproof and waterproof. Certifications: The system shall be CE and FCC Certified. Transaction Log Capacity: Minimum 1,00,000 transaction logs. Rack Door Locks: Each rack shall have an electronic digital swing handle lock on both the front and rear doors. Lock Technology: Digital swing handle lock shall use low-power gear motor technology. EM (Electromagnetic) locks shall not be used at the rack level. Lock Monitoring: Digital swing handle lock shall have integrated lock and latch status sensors and an integrated LED status indicator. Software Integration: The Access Control System shall integrate with the MDC Monitoring Software for remote monitoring and management.
Contd... | - | - | - | - |
| 8 | IR Camera:
Camera: 4 MP Dome Camera. NVR: 8-Channel Network Video Recorder (NVR). Storage: 2 TB Surveillance Grade Hard Disk Drive (HDD).
Contd... | - | - | - | - |
| 9 | Warranty including CAMC: 5 Year warranty/CAMC on all above mentioned components.
Contd... | - | - | - | - |
| 10 | Monitoring Details: Integrated MDC Monitoring Software with Monitoring for Rack Power, Environment, Cooling Unit, Fire Detection, Rack Access Control, Door Status, Temperature, Humidity, Power Parameters, Energy Consumption, and Alarm Monitoring
Contd... | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.98 MB
BOQ_1054431.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .