RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Automated Hematology Analyser ( 5 Part ) ( 1 pieces ) Technical Specifications 1/10 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Certifications for the product CE European (with verified number) * Certification number and date - * Confirmity to quality management standards ISO 9001 & ISO 13485 * Confirmity to electrical safety standards IEC 61010-1
RequiredIEC 61010-2-081
RequiredIEC 61010-2-101 or BIS equivalent * Performance Parameters UMDNS Name and Code "Analyzers
RequiredLaboratory
RequiredHematology
RequiredCell Counting
RequiredAutomated [17-741] Analyzers
RequiredLaboratory
RequiredHematology
RequiredCell Counting
RequiredSemiautomated [17-742] Analyzers
RequiredPoint-of-Care
RequiredWhole Blood
RequiredHematology [18-513] Computer Aided Detection Systems
RequiredPathology Slide
RequiredBlood Cell Classification [24-248]" * Clinical Purpose Hematology Analyzers are used to count and characterize blood cells for disease detection and monitoring. Basic analyzers return a complete blood count(CBC) with a 5-part differential white blood cell(WBC) count.Sophisticated analyzers measure cell morphology and can detect small cell populations to diagnose rare blood conditions. * Type of Configuration benchtop * Type of system offered closed system closed system Type of automation fully automatic * Equipment should have Yes * 2/10 automatic start up
Requiredshut down and sample analysis Analysis principle Based on principle of counting and sizing Based on principle of counting and sizing
RequiredLASER based scatter analysis Type of cell counting 5 part WBC differential with Retics and NBRC enumeration capability 5 part WBC differential with Retics and NBRC enumeration capability Should have multi channel analyssi for better resolution and reproductability Yes * Analysis available WBC
RequiredLympho#
RequiredLympho %
RequiredNeutrophil#
RequiredNeutrop hil %
RequiredBasophil#
RequiredBasoph il%
RequiredEasinophil #
RequiredEasino phil%
RequiredMonocyte#
RequiredMono cyte%
RequiredRBC
RequiredHGB
RequiredMCV
RequiredP CV
RequiredMCH
RequiredMCHC
RequiredRDW- SD
RequiredRDW CV
RequiredPLT
RequiredMPV
RequiredP DW
RequiredPLT
RequiredPLCR
RequiredPLCC
RequiredHCT
RequiredPCT
RequiredRET#
RequiredRET%
RequiredNRBC #
Requiredsynovial
Requiredser ous) parameters like WBC-BF
RequiredRBC-BF
RequiredMN #
RequiredMN%
RequiredPMN%
RequiredPMN#
RequiredTC-BF# Yes Yes IPF analysis Yes Yes PLT-0 Analysis Yes Yes PLT-F Analysis Yes Yes IG % analysis Yes Yes IG# analysis Yes Yes RET-HE analysis Yes Yes HFR analysis Yes Yes LFR analysis Yes Yes MFR analysis Yes Yes IRFanalysis Yes Yes Discrete analysis modes available CBC
RequiredCBC+DIFF
RequiredCBC+R ETIC
RequiredCBC+RETIC+DIFF CBC
RequiredCBC+DIFF
RequiredCBC+R ETIC
RequiredCBC+RETIC+DIFF
RequiredCBC+NRBC
RequiredCBC+Diff+ NRBC
RequiredCBC
RequiredCBC+DIFF
RequiredCBC+RETIC
RequiredCBC+RETI C+DIFF 3/10 Analysis method for WBC Tri angle Laser flow cytometry Tri angle Laser flow cytometry method for platelet measurement dual angle light scatter/fluroscent dye based dual angle light scatter/fluroscent dye based RBC Measurement method electrical impedance electrical impedance Hb measurement cyanide free colorimtery cyanide free colorimtery Retic measurement on board light scatter(flouroscent dye/retic stain based) for reticulocyres on board light scatter(flouroscent dye/retic stain based) for reticulocyres no of sample racks to cater to different tube sizes 1 1 Maximum sample Aspiration volume needed in all modes 100 µl or less 100 µl or less Minimum sample volume required in all modes 20µl or less 20µl or less Throughput capacity in CBC/Differential > 100 > 100 Throughput capacity in Retic mode 45 or more 45 or more Type of modes of sample running Closed vial Closed vial Linearity of Platelet " 0 to 3000 * 10 3 cells micro litres" * RBC Linearity 0 to 8 x 10^6 per micro litre or more * Hemoglobin linearity 0 to 25 gm per litre 0 to 25 gm per litre Rectic linearity 0 to 24.5 0 to 24.5 WBC linearity " 0 to 300 * 1000 cells micro litres" * Directly measures MCV Yes * Time taken by the analyser to produce the test results(Analysis time) in seconds 40-60 * Availability of Auto dilution Yes Yes
RequiredNo should have clot detection facility Yes Yes Automatic probe wipe Yes * 4/10 Extended Analyses for cytopenic samples Yes * Number of reagents 5 * Quality assurance system with calibration and controls Yes * Atleast 3 quality control programs Yes * Type of Calibration Both manual and automatic Both manual and automatic Direct aspiration for capillary blood from finger prick No No Floating discriminator for platelets and RBC counting for reliable RBC and PLT data Yes * Separate diluting nozzles for RBC and WBC Yes Yes Double bathing mechanism Yes Yes Upgradable to integrate with attachment "Fully automated slidemaker & slide stainer" "Fully automated slidemaker & slide stainer" Data Management and Display Type of data management inbuilt system inbuilt system Display LED LED PC hard disk >500 GB >500 GB Inbuilt monitor size in inches NA (for PC based) >5
RequiredNA (for PC based) Processor of PC Provided with system I 5 or more I 5 or more RAM 8 GB 8 GB HDD 1 TB 1 TB PC Monitor size in inches if PC provided externally 17 INCHES OR MORE 17 INCHES OR MORE The processor and RAM of the board system should be latest version Yes * HIS/LIS Interface RS232 RS232 Type of external storage USB USB No of USB Port 4 4 5/10 provided Printer facility Yes Yes Type of printer unit External External Printer type LASER printer LASER printer Display and print provided scatter plot and histograms * Auto loader facility Yes * Facility for user defined flagging Yes * "Database capability of storing sets of results and graphics" >= 50000 >= 50000 L J Plot facility Yes Yes delta check for cumulative review Yes Yes
RequiredNo On line QC option Yes Yes patient moving average Yes Yes QC File management Yes Yes Facility for workload recording Yes * "Flagging in event of unacceptable control data" Yes * Ability to transmit results to host computer Yes * Make of PC provided (Reputed make PC to be provided ) - * Type of user Interface or data entry all three all three Have auto cleaning function in the analyser’s software Yes * Power Requirements Type of power supply in VAC
RequiredHz 100-240 VAC
Required50-60 Hz * Power Backup facility UPS * Type of UPS Online * Rating of UPS in KVA 0.5 KVA 0.5 KVA Back up time in minutes 30 min 30 min 6/10 AVAILABILITY OF Sufficient Number of Quality control fileswhich store 100 or more XB Analysis Yes * ACCESSORIES
RequiredSPARE PARTS AND CONSUMABLES "Offered equipment unit to be supplied with sufficient consumables (with at least 2/3rd of total shelf life) required for
Requiredsufficient to carry out haematological testing of samples" 500 500 Should have on board regent facility and automatic reagent inventory management Yes * Net work integration with lab information system feature Yes Yes Operating temperature and humidity "Capable of operating continuously in ambient temperature of 10 to 35 deg C and relative humidity of 15 to 85% in ideal circumstances" * Miscellaneous Parameters Warranty in years 3 3 Number of installations in Central/State/PSU Govt Hospitals ( Hint: Seller should supply a performace certificate of the device to the buyer incase demaneded after placement of order) More than 3 More than 3 OEM/Reseller ( if supplied by reseller shall ensure uninterputed availabilty of all spares for 10 years) Yes * Availability of toll free facility for technical support maintened by OEM or authorised agencies Yes Yes 7/10 During the warranty period it shall be ensured that all the break down calls are attended with in 48 hrs and the complete details of service agents/contact details should be furnished to buyer and consignee at time of supplies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished Yes * List of important spares and accessories
Requiredwith their part numbers to be supplied to the buyer at the time of supplying the equipment Yes * Installation and Demonstration of equipment and training to be provided after completing supplies before acceptance Yes * The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * Calibration certificates as per NABH requirement Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. 8/10