Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.9 LAccepted-AOC 78 PARASI NEAR PRIMARY SCHOOL PARASI RENUSAGAR RENUSAGAR RENUSAGAR SONBHADRA UTTAR PRADESH 231218 | SONBHADRA | UTTAR PRADESH | 231218 | 1 | Accepted-AOC L-I | |
| 2 | 2₹14.0 L+₹24,853 (1.81%)Rejected-Finance | 2 | Rejected-Finance Stands Highest | |
| 3 | Rejected-Technical | - | Rejected-Technical Incomplete Docs |
Tender Value
₹13.1 L
EMD Value
₹26,000
Closing Date
25 Jan 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER O and MC II DTPS ANPARA
OFFICE OF SUPERINTENDING ENGINEER O and MC II DTPS ANPARA
Overhauling/Servicing/Replacement of HP/ LP Valves of Turbine side of Unit No. 7 2X500 MW DTPS Anpara
2020_RVUNL_537018_1
08/TMD/DTPS/2020-21
Open Tender
Power/Energy Projects/Products
Piece-work
25 days
Anpara
Tender Cost, EMD and
Docs as per PQC
2 documents required · 2 mandatory
₹1,180
Dy GM CFA and BO DTPS Anpara
₹26,000
18 May 2021
15 Dec 2020
27 Jan 2021
15 Dec 2020
25 Jan 2021
15 Dec 2020
120 days
Servicing of Isolating Valve, Control Valve & NRVs of Condensate Line, TDBFP Extraction, Extraction-5 and Booster Pump Suction Line; Size: 400 mm, Class: 150 to 300.
Servicing of Isolating Valve, Control Valve & NRVs installed on BFP discharge, Feed Discharge Line, HPH Inlet/ Outlet, HPH 50% Bypass and other similar valve; Size: 350 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC.
Servicing of HPH 100% Bypass valve and Feed water inlet to Economiser of Size: 500 mm, Class:2850
Servicing of BFP Recirculation Line Control Valve; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC.
Servicing of BFP Recirculation Line Isolating Valve and SCNRV; Size: 200 mm, Class: 2500 Design press.: up to 320 Kg/cm2, temp.> 180 oC.
Servicing of Isolating Valve and Control Valve from Main Steam Line to Auxiliary Steam Header; Size: 200 mm, Class: 2750 SPL Design press.: 188.5 Kg/cm2, temp.: 545 oC.
Servicing of Main Steam Control Valve to Aux Steam Header; Size: 350 mm, Class: 3500 Design press.: 188.5 Kg/cm2, temp.: 545 oC.
Servicing of Isolating, Control Valve and SCNRVs installed on Aux Steam, Extraction Steam to Deaerator, Extraction Steam to TDBFPs, Extraction Steam to LPH-3; Size: 500 mm, Class: 150 to 300 Design press. <40 Kg/cm2, temp.<330 oC.
Servicing of Extraction Steam Valve or NRV to LPH-2; Size: 800 mm, Class: 150, Design Press.: Vacuum, temp.:135 oC.
Servicing of motor operated control valve, motor operated gate/ globe valves, manually operated gate/ globe valves, check valves; Size:300~350 mm, Class: 150 to 300, Design Pr.< 40 Kg/cm2 and temp.:350 oC.
Servicing of HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:185 oC.
Servicing of HP Bypass Warm up line regulating valves, Isolation valves, NRVs and other similar valve; Size:50 to 80 mm, Class: 3000 special, Pr.: 188.2 Kg/cm2 and temp.:545 oC.
Servicing of turbine MAL drain valves & Angle Drain Valves (MAL-11, MAL-12, MAL-22, MAL-26, MAL-27, MAL-31, MAL-32, MAL-47, MAL-51, MAL-52, MAL-54, MAL-55, MAL-65, MAL-81, MSV-105, MSV-106, HRHV-105, HRHV-106) and othe similar valves.
Servicing of Isolating valve and control valve of Feed Control Station Size:250 mm, Class: 2500, Pr. : 320 Kg/cm2 and temp.:260 oC.
Servicing of Isolating valve, control valve and NRVs of Size:250 mm, Class: 150-600.
Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 1500, Pr. : 54 Kg/cm2 and temp.:360 oC.
Servicing of Isolating valve, control valve and NRVs of Size:150 mm to 200 mm, Class: 150-600.
Servicing of Isolating valve, control valve and NRVs of Size:40 mm to 50 mm, Class: 1500 to 2500.
Servicing of HP Evacuation valve.
Servicing of Hydraulic Operated Vacuum Breaker Valve.
Servicing of Isolating valve, control valve and NRVs of Size: 15 mm to 100 mm, Class: 1500.
Replacement of LP valves of different Floors by cutting of damaged valve & arc welding of new valve. Size: 15~50 mm.
Replacement of HP line drain valves of different Floors by cutting of damaged valve & welding of new valve. Size: 15~50 mm.
Replacement of HP line valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40~65 mm.
Replacement of HP valves of Feed Water/ Main Steam Line/ CRH Line/ HRH Line etc; size Nb-65~150 mm.
Replacement of LP Valves of size Nb-300 mm, Pressure rating < 40 Kg/cm2.
Replacement of LP Valves of Nb-250 mm, Pressure Rating < 40 Kg/cm2.
Replacement of LP Valves of Nb-350 mm, Pressure Rating < 40 Kg/cm2.
High Pressure Argon/ Arc Welding by IBR Welder.
Replacement of butt welded gate / globe valves of LP lines. Size: 80-100 mm.
Repair/ Replacement of LP/HP piping by cutting & welding on per mm ID basis.
Replacement of flange type gate / globe valves of LP lines; Size: 75 -100 mm.
Servicing of Safety valve of HP Heater, Deaerator & FST, HT< Header of Aux. PRDS & TDBFP Inlet Steam line.
Revisioning / Servicing of Butterfly valves; Size: 65 mm to 250 mm.
Revisioning / Servicing of Butterfly valves; Size: 300 mm to 800 mm.
Revisioning / Servicing of TDBFP Exhaust Butterfly valves; Size: 1600 mm.
Revisioning / Servicing of Condenser inlet/ outlet Butterfly valves; Size:2200 mm.
Revisioning / Servicing of NRV installed on ACW line & ECW line; Size: 300 mm to 500 mm.
Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 65~250 mm.
Servicing of gear boxes of butterfly valves installed on ACW & ECW System. Valve Size: 300 to 600 mm.
Servicing of gear boxes of butterfly valves installed on ACW System. Valve Size: 800 mm.
Servicing of gear boxes of butterfly valves Size: 1600 mm.
Servicing of gear boxes of butterfly valves Size: 2200mm.
Inspection/ Minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size: 2200 mm.
M/S BHARAT ENGINEERS AND ERECTORS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .