| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹37.6 LAccepted-AOC GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | ₹37.6 L Quoted ₹39.1 L | L 1 | Accepted-AOC Being lowest bid and EAS Accepted by TC |
| 2 | L 2₹42.3 L+₹3.2 L (8.15%)Rejected-Finance 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | ₹42.3 L+₹3.2 L (8.15%) | L 2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L 3₹44.9 L+₹5.7 L (14.6%)Rejected-Finance | ₹44.9 L+₹5.7 L (14.6%) | L 3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L 4₹48.6 L+₹9.5 L (24.2%)Rejected-Finance 118 442 E 2 KAUSHALPURI KANPUR 208012 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹48.6 L+₹9.5 L (24.2%) | L 4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43.0 L
EMD Value
₹85,920
Closing Date
18 Sept 2024, 6:00 pmClosed
GE (EAST) LUCKNOW
GE EAST LUCKNOW PIN 226002
SPL REPAIR REPLACEMENT TO ELETRIC METER PANEL AT SANJOG CHHETRI VIHAR JCOS ORS MD ACCN AND IMPROVEMENT OF RE WIRING IN BLDG NO P 39 ALONG WITH CHEMICAL EARTHING AT HQ CC CCSOW UNDER GE EAST LUCKNOW
2024_MES_667645_1
GE/E/LKO/T-45 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹85,920
Yes
24 Oct 2024
24 Jul 2024
25 Sept 2024
24 Jul 2024
18 Sept 2024
7 Aug 2024
Amount
Material and labour for one way switch 6 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall/ floor by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick modular type etc incl taking down old wiring with complete switch and socket any type and making good to the disturbed surfaces to match the existing complete all as specified and directed. one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.compete all as specified and directed.
Material and labour for one way switch 6/16 Amp wiring with 2.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall/floor by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick modular type etc. incl taking down old wiring with complete switch and socket any typeand making good to the disturbed surfaces to match the existing complete all as specified and directed. one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.compete all as specified and directed.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
Supply and fix fan step regulator, 120W 2 module complete all as specified and as directed
S&F Modular White cover plate with frame,12 module complete all as specified and as directed
S&F Modular White cover plate with frame,8 module complete all as specified and as directed
S&F Modular White cover plate with frame,3 module complete all as specified and as directed
Supply and fix of recessed mounted 2'x2' LED ceiling light fitting 36 watt, 6500K, with IP 20 protection comprises of CRCA housing, high efficiency diffuser cover, electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix of industrial type AC Modular type SPN enclosure with plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Material and labour for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases incl taking down old wiring with complete switch and socket any type in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall incl taking down old wiring with complete switch and socket any type and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Supply and fix SPN MCB DB 12 ways with 200 Amps rated bus bar 240Volt, Double door type all as specified
Supply and fixing MCB SPN 32 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed.
Supply and fixing MCB SP 6-32 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all as specified and directed
M&L for Chemical earthing complete for VTPN DB's with copper earth plate electrode in ground (Earth pit not less than 2.25 metre below normal ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected and including copper strip 25mm x 4mm (upto the body of euipment ) by means of GI bolts, nuts, check nuts and washers, earth plate surrounded by picked layers of chemical 15 cm thick, all ground top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel, testing on completeion including PCC chamber (1:3:6) using 20mm grade stone aggregate and 50mm thick cover with RCC 1:2:4 type B-1 using 20mm grade stone aggregate and 8mm dia deformed TMT bars @ 10 cm C/C both way including form work and MS frame using MS angle of size 45mm x 4 mm x 5mm complete all as shown in electrical plate No. 3 of MES schedule 1991 Part-I compete all as specified and directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 08 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 160 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 63 Amp, "C" curve, 10 KA breaking capacity - 06 Nos. (c) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 06 Nos.
Supply and fix in repairs copper strip of size 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level compete all as specified and directed.
Supply and fix in repairs Air Termination, single pointed copper rod 12mm dia and 300mm long compete all as specified and directed. by Engineer-in-Charge.
Supply and fix epoxy insulator with red colour incl with nut and bolt suitable for fixing size of strip 25 X 3.15 mm compete all as specified and directed.
Supply and fix in repairs Test Point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexognal head screw.compete all as specified and directed.
Supply and fixing in wall galvanised iron water tubing medium grade 20 mm including provison of all necessary nuts, bolt, steel fittings/accessaries complete all as specfified and directed for the following sizes.
Supply, laying and testing of size 50 sqmm 4.0 core XLPE cable insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor , lugs complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient incl cutting of floor after laying of cable re -plastring of cutting surface complete all as directed & specified
M & L for Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M & L for Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement)
M & L for Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other compete all as specified and directed.
Supply and fixing in replacement of HDPE corrugated pipe of ISI marked 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required incl taking down old pipe with complete fittings any type compete all as specified and directed.
Material and labour in replacement for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing colour code with 1mm putty complete all as specified & directed. Note : 2 runs of 6 sqmm, 1 run of 6 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
Supply and fixing in replacement of HDPE corrugated pipe of ISI marked 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and directed.
Supply and fix in replacement SPN MCB DB 8 ways with 200 Amps rated bus bar 240Volt, Double door type complete all a specified and directed
Supply and fixing in replacement MCB SPN 32 Amps 240 V, C- curve, 50 Hz, breking capacity-10 kA. complete all as specified and directed.
Supply and fixing in replacement MCB SP 6-32 Amps240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all as specified and directed.
M&L in replacement for incl nessasary earth work complete earthing complete for panel with galvanized steel earth plate electrode in ground (Earth pit not less than 2.25 metre below normal ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected and including GI earth lead 4.00 mm dia (upto the body of euipment ) by means of GI bolts, nuts, check nuts and washers, earth plate surrounded by picked layers of coal dust and common salt 15 cm thick, all ground top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel, testing on completeion including PCC chamber (1:3:6) using 20mm grade stone aggregate and 50mm thick cover with RCC 1:2:4 type B-1 using 20mm grade stone aggregate and 8mm dia deformed TMT bars @ 10 cm C/C both way complete all as shown in electrical plate No. 3 of MES schedule 1991 Part-I including taking down old earthimg complete all a specified and directed by Engr-in-charge.
HS ASSOCIATES (BID ID -3089977)
M/s Bhadoria Associates (BID ID -3098607)
Supreme Builders (BID ID -3097608)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .