Repair and maintenance of internal wiring EM Fittings and fixtures at Md Accn under jurisdiction of GE Army Jaisalmer
2019_MES_282581_1
8810/19-20/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹60,000
Yes
3 Feb 2020
16 Sept 2019
14 Oct 2019
16 Sept 2019
12 Oct 2019
26 Sept 2019
Amount
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surface of walls,floors etc all as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down submain wiring any type any size from existing conduit complete all as specifie d and directed
Taking down light fitting any type any watt complete all as specified and directed
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, PVC casing caping and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box of 1.8 mm thick and 60 mm deep (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps.
All as per Item No 5.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board.
All as per Item No. 5.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board.
All as per Item No 5.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified.
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and existing PVC /Steel Concealed conduit of 20 mm bore with accessories in wall floor etc ISI mark covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps.
all as per Item No 9.00 here-in-before but for one bell/buzzer point controlled by one push botton.
all as per Item No 9.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board.
all as per Item No. 9.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board.
all as per Item No. 9.00 here-in-before but for point wiring controlled by 2 way switch
all as per Item No 9.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLS) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLS) in and including PVC Concealed / Surface Conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC Conduit shall be paid as one unit length.)
S&F switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete specified.
S&F switch piano, flush type, 15 amps, 230 volts, single pole, one way (ISI marked) complete all as specified.
S&F switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified
S&F sockets outlet multipurpose 2 in 1, 5 Amps flush type confirming to IS all as specified.
S&F sockets outlet multipurpose 2 in 1 pin, 5 and 15 Amps flush type confirming to IS all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Modular Switch Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for modular step type fan regulator 120 watt 2 module suitable for operation on 230 volt 50 HZ AC supply complete all as specified and as directed
S & F for Modular Bell Switch 6 Amps, single pole, single module complete all as specified.
S&F ceiling rose, PVC of size 65 mm x 18 mm two to three terminals (ISI marked) all as specified.
S&F bell push flush type 5 Amps complete all as specified.
S&F stepped type, Socket type, electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specfied
M&L for lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings including taking down unserviceable lamp holder of any description complete all as specified
S&F bell AC single pole Ding Dong type 230 volt all as specified.
S & F in repair of LED tube light fitting 18/20 watt tube LED, Neutral white in colour 1200 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified and directed.Make: Havells/ Philips/ Crompton/ Bajaj / Wipro/ Syska/ Philips.
S & F in repair of LED tube light fitting 9/10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified and directed.Make :- Havells/ Philips/ Crompton/ Bajaj / Wipro/ Syska/ Philips.
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 15 watts complete all as specified and as directed. Make Havells Cat No LHDLO6160099 or its equvalent in Philips, Bajaj.
S&F, sheet metal single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 10 Amps 240 volts all as directed.Make - S Schindier/Legrand/L&T/ ABB/C&S
S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Make - Schindier/Legrand/L&T/ ABB/C&S
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Make - Schindier/Legrand/L&T/ ABB/C&S
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA complete all as specified and as directed. Make - Schindier/Legrand/L&T/ ABB/C&S
S & F for MCB Single pole and neutral rated capacity 40 A, 240 volts breaking capacity 10 KA complete all as specified and as directed. Make - Schindier/Legrand/L&T/ ABB/C&S
M & L for bore earthing not less than 250mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanised iron pipe 40 mm bore medium grade 3m long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre upto 2.5 m of length from bottom, burried directly in ground filled with 45 cm alternate layer of magnesium sulphate, charcol & salt up to ground level & connected to galvanised iron strip 32 x 6 mm upto 7.5 Mtr above ground level as earthing lead by means of bolt and nut, check nuts and washers of galvanised iron or steel including brazing work upto equipment in including GI strip drawn into GI pipe 40 mm dia light grade up to required as protection pipe top edge of earth electrode to be plugged with GI plug including taking out old earthing complete all as specified.
S & F for MCB Single pole rated capacity 6 to 32 A, 240 volts breaking capacity 10 KA complete all as specified and as directed. Make - Schindier/Legrand/L&T/ ABB/C&S
S.D. And Company
vinayandsons
M/s Shri Inder Construction Company
Dwarka Enterprises
Rasam Engg Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .