Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.7 L+₹3.7 L (15.0%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹23.3 L
EMD Value
₹46,500
Closing Date
8 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF GUARD ROOM WITH ATTACHED TOILET AND BATHROOM AT AP HATIALI AND GANESHBARI UNDER GE DINJAN
2020_MES_351323_3
C/8972/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE DINJAN
₹46,500
Yes
2 Nov 2020
16 Sept 2020
10 Oct 2020
16 Sept 2020
8 Oct 2020
25 Sept 2020
60 days
Amount
Surface dressing not exceeding 15cm deep in soft /loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation etc or for shafts, wells, cesspits ,manholes, pier holes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out soft/loose soil complete all as specified and as directed.
Returning, filling in soft and loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in soils complete all as specified and as directed.
M&L for cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any ) of foundation and plinth beams: and similar work: vertical or to batter rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete square, rectangulr or polygonal complete all as specified and as directed.
M&L for form work to soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc rough finished flat surfaces complete all as specified and as directed.
M&L for form work to edges of concrete flats and sides of RCC/PCC bands in walls,horizontal or slopeing and similar work all exceeding 20cm wide rough finished flat surfaces complete all as specified and as directed.
M&L for RCC (design mix) M-25 (using 20 mm graded aggregates) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC (design mix) M-25 (using 20 mm graded aggregates) in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC (design mix) M-25 (using 20 mm graded aggregates) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC (design mix) M-25 (using 20 mm graded aggregates) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
M&L for DPC to horizontal or vertical surfaces incl necessary formwork in cement concrete 1:2:4, type B-1, 40mm thick complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for sand filling under floors or in foundations incl watering and consolidation complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and cm thick, watered and rammed to a true surface of broken stones complete all as specified and as directed.
M&L for cement concrete in sub floors, sub bases type C-2, 1:3:6 (using 40mm graded aggregate) 75mm thick complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06Sqm but n. exc 0.11 qm, in floors etc. including 15 mm thick screed bed or bedding laying in cement mortar (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11Sqm but n. exc 0.18 qm, in floors etc. including 15 mm thick screed bed or bedding laying in cement mortar (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc. 0.11Sqm but n. exc. 0.18Sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including10mm thick in cement mortor in 1:4 on fair face of brick work in dado and skirting finish fare & even to receive tiles etc complete all as specified and as directed.
M&L for glazed colour ceramic tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in cement mortor (1:4) as a backing coat complete all as specified and as directed.
M&L for glazed colour ceramic tiles in vertical surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in cement mortor (1:4) as a backing coat complete all as specified and as directed.
M&L for 15mm thick rendering cement mortar (1:4) on fair faces of brick work in two layers (10mm and 5 mm thick) mixed with water proofing compound in top layer as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note : Integral water proofing compund shall be measured and paid separtely.
Supply only integral water proofing compound conforming to IS : 2645-1975 specifications complete all as specified and as directed. Make : CICCO No -1/SIKA/ACCO PROOF
M&L for rendering 5 mm thick in cement mortar (1:3) for fair finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) for fair finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and as directed.
M&L for three coats of white wash on ceiling including preparation of surfaces complete all as specified and as directed.
M&L for preparation of surfaces of wall and applying two coats of distemper over a coat primer complete all as specified and as directed.
M&L for preparation of surfaces of wall and applying two coats of acrylic weather proof external emulsion over one coat of acrylic primer complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein belowand directed :- (a)15 mm thick plastering in cement mortar 1:4 finished even and smooth. (b) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (c) Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horinzontal face of groove with cement mortar 1:3. (d) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete 1:2:4, Type B-1 as required exc. half brick wall but n. exc. one brick wall complete all as specified and as directed.
S&F for mild steel flat iron work as in holdfasts etc and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for preparing surfaces of timber piles and diping in a hot mixture of tar and creosote in the proportion of 20 Kg coal tar pitch to 25 litres of creosote oil, for 4 mins complete all as specified and as directed.
S&F for 2nd class hard wood, solid straight chowkat and frame, wrought framed rebated on the solid rounded of chamfered put together with glue pinned a joints complete all as specified and as directed.
S&F for 35mm thick plain framed panel shutters (three panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
M&L for 35 mm thick 2nd Class H/Wood gauged and skeleton shutters, open rebated and prepared to receive gauge etc (with sash bars), edges of raming plain, chamfered or grounded, fitted with cut of and mitred beads for securing gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and as directed.
S&F for 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5Sq m in each pane complete all as specified and as directed.
S&F for galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and as directed.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290 Gde-E-165 complete all as specified and as directed.
S&F for solid PVC door frame of size 50 X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed in repair in opening as per specifications and drawing complete all as specifiedn and as directed.
S&F for factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; Panelling of plain colur PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, Supplied and Fixed in the frame at site as per specification and drawings complete all as specified and as directed.
S&F for 100mm butt hinges medium weight cold rolled mild steel complete all as specified and as directed.
S&F for 150mm long aluminium anodised tower bolts complete all as specified and as directed.
S&F for 125mm size aluminium anodised door handles complete all as specified and as directed.
S&F for 300 mm long alluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded section and fixing bolts and sliding of extruded section complete all as specified and as directed.
M&L for preparation of wooden surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
S&F for 15mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F for 20mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F for 10 litres capacity PVC flushing cistern low level white colour including PVC connection PVC flush pipe of reqd length CI brackets nin lieu of old unservisable push button flushing system complete all as specified and as directed.
S&F for vitreous china squating pane orissa pattern size 580x440mm white with internal footrest (excluding fixing bolts flushing cistern and flush pipe) complete all as specified and as directed.
S&F for bib taps fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete all as specified and as dierected.
S&F for swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all as specified and as directed.
S&F for shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour (Minimum weight 40gms) complete all as specified and as directed.
S&F for towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
S&F for stop valves, fancy type, chromium platedcast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for pillar taps, fancy type cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore complete all as specified and as directed.
S&F for 15mm size PVC Connection with PTMT nut of length 450mm complete all as specified and as directed.
S&F for vitreous China bowl urinal flat back, size of 465x355x265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400m excluding taps, waste , chain & plug & porcelain stopper ut including brackets incl cutting for pinning in ends of bracketes or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks of capacity 500 iltres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
S&F for PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for PVC (SWR) bends any radius 100 mm dia complete all as specified and as directed.
S&F for PVC (SWR) floor trap, 75 mm bore plain with grating including jointing with solvent cement
M&L for salt glazed stone ware drain pipes 150mm dia graded "A" laid in trenches, jointed and tested complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded coarse aggregate) as in bed to 150mm dia drain pipe including packing under and haunching against the size of pipe after they are laid and tested complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area), PVC insulated FRLS, multistranded, single core, sheathed, copper conductor cables with low halogen drawn through concealed including PVC casing caping with all fittings and accessories (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) PVC insulated, sheathed, stranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point including steel terminal box made out of 1.2mm thick MS concealed in walls for housing switches, sockets, regulators, etc for ne light point/fan point controlled by one switch complete all as specified and as directed.
All as per item No. 72 here-in-above but one 5A 3 Pin switch socket combination on independent board.
All as per item No. 72 here-in-above but one 5A 3 pin socket outlet on same board.
All as per item No. 72 here-in-above but wiring with cables of size 2.5 sqmm & cables of size 2.5 Sqmm as continuous earth wire for one 15 Amps switch socket combination on independent board.
S&F for switch piano, flush type, 5/6 Amps, single pole, one way, 240 volts complete all as specified and as directed.
S&F for socket outlet 3/5 pin 5A flush type complete all as specified and as directed.
S&F for switch socket combination 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and as directed.
S&F for switch socket combination 2 in 1, 6 pin, 6/16 Amps, flush type, 240 volts complete all as specified and as directed.
S&F for ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete all as specified and as directed.
S&F for lamp holder insulated body with back plate suitable for batten/PVC fittings complete all as specified and as directed.
S&F LED bulb 9 watt complete all as specified and as directed. Make : Crompton/Bajaj/Havells
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed. Make : Cat No : DHDPSHODRW04 of Havells/L&T/Legrand
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with 200 Amps rated common bus bar at incomming end, SPN, 4 way, 240 Volts, suitable for housing MCBs complete all as specified and directed. Make : Cat No : DHDPSHODRW04 of Havells/L&T/Legrand
S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No TSPC6-32 of HPL/Havells/Legrand
S&F for MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No TSPNC6-32 of HPL/Havells/Legrand
S&F for decorative ultra slim round profile LED lighting fixture with LED tube integrated type for 18/20 watt , energy efficient ready to use pack complete all as specified and as directed. Make: Bajaj/Havells/Philip
S&F for 20 watt Cub LED building security light fitting comes with pressure die cast housing, prismatic polycarbonate diffuser, LEDs with secondary optic and IP65 protection including GI bracket of 32 mm bore n.less than 1 mtr complete all as specified and as directed. Make : HPL/Havells/Bajaj
S&F for ceiling fan 1200 mm sweep 230 volt, 5 Star rating including hanging arrangement of fan under different roof with considering the effective air circulation on carpet area and made out of heavy duty MS rod/flat hook etc making connection by using 3 core 1 Sqmm flexible wire complete all as specified and as directed.
S&F for heavy duty exhaust fan 300 mm sweep, 900rpm, 240V with all accessories complete all as specified and as directed. Make : Model Turbo force SP of Havells/Bajaj/Usha
S&F in repair stepped type electronic fan regulator flush type 230 volt 5 speed control and connecting up and fix position , complete all as specified and as directed. Make : ANCHOR/Legrand/Havells.
M&L for sub main wiring with two runs of 6 sqmm (Nominal area) single core cable FRLS multistranded,copper conductor cables 1100 Volts grade drawn through providing (new) casing-caping of suitable size, fixed to wall/ceiling etc including 4 sqmm single core as earth wire and duly connected to common earth point complete all as specified and as directed.
S&F for 10W, LED energy saving new generation bulk head luminaire with opal diffuser including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Cat Part No - RUGBYNEONFT10WLED860SSYMTOPC of Havells/Bajaj/Philip.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe , wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm, 2 core complete all as specified and as directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm, 2 core complete all as specified and as directed.
M&L for sand cushioning for protection of cable complete all as specified and as directed.
Supply and laying well burnt bricks,sub class "B" bricks laid breath wise along length of cable in trenches for cable protection laid for UG cable protection complete all as specified and as directed.
Supply and laying tube galvanised iron light grade 25 mm size for protection of cables complete all as specified and as directed.
Labour for Horizontal Boring Road/Foot Path, not exc. 15.00 metre in length by any method for 40 mm dia GI pipe complete all as specified and as directed.
M&L for tubes med grade galvanised iron with all fittings laid under trench as directed for the 25 mm bore of pipes complete all as specified and as directed.
M&L for tubes med grade galvanised iron with all fittings and fixed complete to walls and ceilings or laid under trench as directed for the 20 mm bore of pipes complete all as specified and as directed.
S&F for gun metal,globe or gate valves, with iron wheel, screwed both ends for iron pipe of size 20 mm dia complete all as specified and as directed.
S&F for gun metal,globe or gate valves, with iron wheel, screwed both ends for iron pipe of size 25 mm dia complete all as specified and as directed.
Cutting the existing 50/40 mm galvanised iron pipe line and making necessary arrangement for taping of new pipe line of 25 mm dia including threading, welding and all required accessories complete all as specified and as directed.
M&L for valve pit and construction of brick masonry valve pit of internal dimension 40 x 40 x 40 cm depth with sub class 'B' bricks in CM (1:6) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:2:4) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 5 mm angle iron and 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and as directed.
FREEZCON
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .