Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC SATYAPIRTALA CHINSURAH DIST HOOGHLY 712101 | CHINSURAH | HOOGHLY | WEST BENGAL | 712101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.9 L+₹1,489.47 (0.10%)Rejected-Finance MALLICK JAYANTI BAGAN KUMAR BAGAN JHAPPUKUR POST SAHAGANJ DIST HOOGHLY HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L2 | Rejected-Finance Highest Amount Quoted | |
| 3 | L3₹14.9 L+₹2,448.76 (0.16%)Rejected-Finance BABUGANJ STRAND ROAD HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L3 | Rejected-Finance Highest Amount Quoted |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
16 Aug 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division
Supply_installation_testing_and__commissioning_of_Silent_Diesel_Generator_set_with_allied_Electrical_installation_work_for_Children_Home_for_Girls_at_Uttarpara_Hooghly
2021_WBPWD_338489_1
WBPWD/EE/ HED / NIeQ-14/ 2021-22
Open Tender
Electrical Work/ Equipment
Item Rate
25 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,000
6 Oct 2021
2 Aug 2021
18 Aug 2021
2 Aug 2021
16 Aug 2021
2 Aug 2021
120 days
Amount
Supply, delivery at site on foundation of 62.5 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine with mannual panel, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure having following specifications :-
ENGINE
Make : Cummins/Greaves Power/Koel i-green(by Kirloskar)/Ashok Leyland as approved by E.I.C
Engine Type : 4 Stroke Diesel Engine
Rated Output : 79 HP or Higher
Duty : PRIME
Cooling : Liquid Cooled
Cylinder : 3/4
Aspiration : Turbo Charged, Cgarge Air Cooled
Type of Governer : Mechanical/Electronic
Fuel Tank Capacity : Minimum capacity 125 Ltrs. Or Higher
Fuel Consumption at 75% rated Load with Radiator or Fan : 11.65 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 15.13 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make: Stamford/CG/Kirloskar/ Ashok Ley Power
Rating : 415 V., 3Ph. 50 Hz., 62.5 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 1.5%
Total Harmonic distortion in output waveform : < 2%
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 62.5 KVA DG set having following specification/features.
i) 100A 36 KA MCCB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc. - 2Sets
ii) In Built By-Pass switch for rated capacity
iii) On -delay timer for load change over
iv) On-delay timer for engine shut off
v) Engine On-Off switch (Push button type)
vii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Nacessary manufacturer's test certificate for Desiel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
(vii) Necessary Control cable (12 Core 2.5 Sq.mm stranded armour copper cable) for connecting DG & AMF Panel -- 5 mtrs. to be supplied on Free of cost
Installation, Testing & Commissioning of 62.5 KVA Silent Diesel Generator Set with Acoustic Enclosure.
S& laying 70 sq. mm. single core multistrand PVC insulated flexible Cu cable in uPVC / GI pipe from earth electrode to neutral earth busbar and from earth busbar to DG neutral point as required (for neutral earthing)
S& laying 2.5 sq. mm. 10core multi core multistrand PVC insulated flexible Cu cable in uPVC / GI pipe from DG to separate AMF panel.
Finishing the cable ends by crimping method incl. S&F copper socket, insulating tape and jointing materials etc. as required suitable for single core 70 sq. mm. copper wire.
Earth work in excavation of foundation trenches of drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.( Depth of Excavation not exceeding 1500 mm ) [ Page- 1, Item no.- 2(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Earth work in filling in foundation trench or plinth with good earth in layers Board a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page 1, Item no.3(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Filling in foundation or plinth by silver sand in layer a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page- 2, Item no.- 4(A) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand [ Page- 14, Item no.1 of PWD Schedule of Rates, Volume-I of Building Works, 2017]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.. A)For works in foundation and top of ground floor / upto 4 m i) Tor steel/ Mild steel SAIL/ TATA/RINL. [ Page- 43, Item no.40(a)(i)(I) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20 mm size) including shuttering and reinforcement, if any, in ground floor as per relevant IS codes ( Pakur variety ) [ Page 26, item no.10 of PWD Schedule for Building works with latest ammendmen ]
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth. [ Page- 16, item no.-13(a)-(i) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Plaster (to wall, floor, ceiling etc.) of 10 mm thick with sand and cement with 1:4 cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] [ Page- 189, item no.-1(ii)-(c) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE: Cement 0.152 cu.m per 100 sq.m. [ Page- 192, item no.-15 of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Filling of HSD Oil for initial refilling as well as for commissioning incl. Cost of transportation
Extending the exhaust pipe with 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set upto 2.5 Mts high of the near higher installation with Asbestos rope / 2" glass wool insulation and chicken net and Aluminium fol covering, with end cap with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC.
a) 100 mm. dia exhaust pipe.
b) Residential type silenser pipe
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 90 mm. dia (Vertical Run).
S&F rain protection canopy.
Supply and delivery of best quality oil hand pump with 1" dia PVC flexible pipe (10 mtr. approx.)
Supply and delivery of 200 ltr. Capacity heavy gauge MS sheet barrel
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-6 SWG [5(a)(i)/G-2]
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3)]
PART-B:- Electrical Installation work for DG Set
Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to be approved by EIC before making of panel. [Emergency LT Panel]
Construction Details : All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.
Incomming Switch : (a) 415V 250 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95642 or equivalent cat of SIEMENS/ABB) in open exexution ------- 1 No.
Bus Bar : 500V, 300 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x40 mm x 5 mm + 1x40 mm x 5 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
Outgoing Switches : (a) 415V 160 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95713 or equivalent cat of SIEMENS/ABB) in open exexution - 2 nos. (b) 415V 63 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95421 or equivalent cat of SIEMENS/ABB) in open exexution----1No.
Metering Panel a) Advanced LED Multifunction Meter Digital Type Load Monitor ( Make L&T, Cat No.- WL442011OOOO) - 1 No. b)LED single function Meter ( Make L& T, Model- CAT No.- WL111020OOOO or equivalent)- for ammeter --- 3 nos. c)LED single function Meter ( Make L& T, Model no..WL112020OOOO or equivalent) for voltmeter-- 3 nos. d) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. d) 200/5 Amp ratio C.T (Kappa) --- 3 nos. e) S & F 6 Amp SPMCB(Make-SIEMENS/LT/Legrand)---6 nos.
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to all outgoing mains i.e., 160A & 63A TPN SDF are to be made by 4 x 20mm x 5mm Cu bars & 16 sq. mm flexible PVC insulated FR Cu cable respectively and also for metering arrangements are to be made by suitable size of Copper wire with proper socketing of the end of each wire leads.
Earthing :- A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board and brought outside the panel. All electrical equipment are to be properly earthed with suitable size G.I. wire.
The complete panel board is to be spray painted after required surface treatment by 9 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :- The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish with following average run. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
8 Mtr [4(c)/ E-25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch as per GS.
On Board [ 3 (i) / E- 20 ]
4.5 mtr. [ 3 (iv) / E- 20 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
4x(10 sqmm)+2x (6 sqmm) [ 1(d1) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 6 sq mm [9(iii) / F-5]
d) 10 sq mm [9(iv) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC.
4 Way ( Up to 160 A ) Make - Legrand, Enclosure 607913/Siemens-Enclosure-8GB31571RC)/ Schneider-Enclosure-A9HVD04M/ L&T Enclosure- (LTVD04MGN) or equivalent cat of SIEMENS as approved by E.I.C][15 / D-11 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand / Schneider/L&T/Siemens) as per direction of EIC]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supplying and fixing 415V TPN SFU with sheet steel enclosure of following rating on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.( Make - L&T /Siemens/Havells)
100A, TPN SFU [4(a)/D-3]
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc( Make- L&T/Havells/ Siemens).
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Nicco / Gloster/KEI/Polycab as approved by E.I.C]
3.5 Core 95 Sq mm
3.5 Core 70 Sq. mm
4 Core 50 Sq. mm
Laying of cable in underground trench as per GS for the following numbers of Cables.
Above 35 and upto 185 Sq. mm [ 1(b)/ F- 2 ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
Above 35 sqmm to 95 sqmm [ 5(ii)/ F- 3 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
25mm dia [11(a)/F-6]
40mm dia [11(c)/F-6]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4/3.5)Core as per GS.
3.5Core 95 Sq. mm [ 7(d)/F4 & 8(b- xviii) /F5]
3.5Core 70 Sq. mm [ 7(d)/F4 & 8(b- xvii) /F5]
3.5 Core 50 Sq. mm [7(c)/F4 & 8(b-vii) /F5 ]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 9(a) / E-18]
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Usha-Striker or equivalent model of CG/Orient)
a. 1200 mm Sweep
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification as per GS. [ 29/D-14 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) ) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
S & D of 500 mm sweep pedestal fan (Make- Usha model no-FARRANTA EX PF/Crompton Greaves model no.-PFWindstar Farranta or equivalent model of Orient as approved by E.I.C).
S & F of grill guard including lock and key arrangement for guarding LT Cubical Panel inside the old main building considering safety issue of children of Children home for Girls'
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-8 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
S & F of porcelain kit kat rewireable type fuse unit (Beat quality approved make) and base complete on Hard Wood Board size 600 x 300 x 25 mm fixed on wall with anchor fastener bolts.
Making holes on brick wall / RCC ceiling 125 mm depth having dia of following sizes :125 mm depth, 100 mm dia. as to GS.[9 / E-3]
TERMS AND CONDITION 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM. 2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL. 3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES.
Add GST @12% except item no.-15:- Rs.
Add LWC @1% except item no.-1,15, 20, 21, 41, 47 & 51:- Rs.
B.S.M ELECTRICAL
D. D. ENTERPRISE
stage.html
html • 0.05 MB
technical_646460.pdf
PDF • 0.61 MB
techsummary_646460.pdf
PDF • 0.76 MB
finance_646460.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_646460.pdf
PDF • 0.49 MB
014.pdf
PDF • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .