Loading…
Loading…
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
29 Oct 2026, 3:00 pm
Published by the portal on this tender, for queries and grievance redressal.
Supply Installation
Testing and Commissioning of Microprocessor based Standalone fire alarm control panel.
Testing and Commissioning of Addressable Smoke Detector with inbuilt optical smoke sensors as per NFPA style 7 wiring complete with base and termination as required
Testing and Commissioning of Addressable Manual Call Point as per NFPA style 7 wiring complete as required with backbox
Supply
Installation
Testing and Commissioning of Sounder Strobe
Testing and Commissioning of Addressable Single Output Module
suitable to drive conventional notification devices or other power required equipment
Testing and Commissioning of Loop Isolator Module
protection facility for addressable loop
Testing and Commissioning of 2C x 1.5 sq mm FRLS Armored Cable
9994766
GEM/2026/B/8125326
Two Packet Bid
Supply, Installation, Testing and Commissioning of 2C x 1.5
Burhanpur, Madhya Pradesh
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
3 yrs
₹1 L
30%
HoD Commercial, Commercial, Department of Heavy Industry, Nepa, Limited Nepanagar Burhanpur, Ministry of Heavy Industries, and Public Enterprises, (Sunil Kumar Kulthe)
Exempted
Yes
8 Oct 2026
8 Oct 2026
30 Oct 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply Installation, Testing and Commissioning of Microprocessor based Standalone fire alarm control panel. | Supply Installation, Testing and Commissioning of Microprocessor based Standalone fire alarm control panel. Each loop capable of taking minimum 1 9 8 detector and devices, 6 x40 character (2 40 x 64 Pixels blue graphical liquid crystal display (LCD) with backlight illumination & alpha-numeric keypad to offer clear menu navigation and quick configuration. The penal shall be addressable type. The panel shall be able give pin point location of all fire / fault conditions. The panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The penal shall have in built rectifier, loop cards LCD unit to indicate fire /fault signal with address internal event log capacity of 500 to 999 non- volatile events complete in all respects with battery backup DXc1-M | 1 | NOS | IMAMALI62 | 15 |
| 2 | Supply Installation, Testing and Commissioning of Addressable Smoke Detector with inbuilt optical smoke sensors as per NFPA style 7 wiring complete with base and termination as required | Supply Installation, Testing and Commissioning of Addressable Smoke Detector with inbuilt optical smoke sensors as per NFPA style 7 wiring complete with base and termination as required (HM-PSEAP + MI/B501AP/IV) | 27 | NOS | IMAMALI62 | 15 |
| 3 | Supply Installation, Testing and Commissioning of Addressable Manual Call Point as per NFPA style 7 wiring complete as required with backbox | Supply Installation, Testing and Commissioning of Addressable Manual Call Point as per NFPA style 7 wiring complete as required with backbox (HM-MCP-GI+BB) | 2 | NOS | IMAMALI62 | 15 |
| 4 | Supply, Installation, Testing and Commissioning of Sounder Strobe | Supply, Installation, Testing and Commissioning of Sounder Strobe (9 7 dB(A) + or - 3 dB At sign 1 meter 2) (WSS-PRNO5 + MI/B5 0 1 AP/IV) | 2 | NOS | IMAMALI62 | 15 |
| 5 | Supply, Installation, Testing and Commissioning of Addressable Single Output Module, suitable to drive conventional notification devices or other power required equipment | Supply, Installation, Testing and Commissioning of Addressable Single Output Module, suitable to drive conventional notification devices or other power-required equipment in 4-wire mode by external 24VDC power supply and also capable to provide dry contact output in loop-powered mode. Maximum 1 A output current. This Shall Include all accessories like additional power supply, relays etc. complete as required for services integration (MI /DCMOE). | 2 | NOS | IMAMALI62 | 15 |
| 6 | Supply, Installation, Testing and Commissioning of Loop Isolator Module, protection facility for addressable loop | Supply, Installation, Testing and Commissioning of Loop Isolator Module, protection facility for addressable loop, can isolate shorted circuit from complete loop to ensure normal operation of other parts (MI/DISO). | 2 | NOS | IMAMALI62 | 15 |
| 7 | Supply, Installation, Testing and Commissioning of 2C x 1.5 sq mm FRLS Armored Cable | Supply, Installation, Testing and Commissioning of 2C x 1.5 sq mm FRLS Armored Cable | 200 | Mtr | IMAMALI62 | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9994766.pdf
GEM_BID • 0.14 MB
technical_specification_2026-10-07-09-25-31_07424c1d974d0b1b5b23203ac148c9e9.pdf
BOQ • 0.73 MB
boq_item_sample_file_2026-10-07-09-25-31_97d6f6495e351652c156848b6ed95ee8.csv
BOQ • 0.00 MB
1791430332.xlsx
GEM_OTHER • 0.01 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .