Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.6 L+₹10,460.61 (0.27%)Rejected-Finance PLOT NO 6A COM 03 VIRNDAVAN YOJNA RAEBAREILLY ROAD LUCKNOW 226029 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226029 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹77,260
Closing Date
23 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Fatehgarh
AGE (I) Fatehgarh
PROVN OF 01 X COMBINE LECTURE POST FOR TRAINING OF AGNIVEER AT RAJPUT REGIMENTAL CENTRE
2025_MES_704301_2
AGE(I)/FAT/ET-72 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹77,260
Yes
23 Jul 2025
21 May 2025
30 Jun 2025
21 May 2025
23 Jun 2025
5 Jun 2025
22 May 2025 - 4 Jun 2025
Amount
M & L for surface dressing n.exc. 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep for foundation and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas, exc 1.50m but not exc. 3 mt depth for Footing in soft/loose soil etc cpmplete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing Excavated material n. exc. 50 M and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and directed.
M & L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. (Note - Reinforcement will be measured and paid separately).
M & L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts etc complete all as specified and directed. (Note - Reinforcement will be measured and paid separately).
M & L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in tie Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed. (Note - Reinforcement will be measured and paid separately).
M & L RCC M-25 design mix (using 20 mm graded stone aggt) as in stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings etc complete all as specified and directed. (Note - Reinforcement will be measured and paid separately).
M & L for Formwork to stair slab with sloping or stepped soffits including risers and stringers (excluding landing) etc complete all as specified and directed.
M & L for brick work with sub class `B' bricks, (old size) straight or curved on plan exc 6m mean radius, built in CM 1:6 in superstructure etc complete all as specified and directed.
S & F for mild steel roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections ractangular/square hallow sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde E-250) quality A including notching, fitting, riveting and welding etc complete all as specified and directed.
S&F for mild steel rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc conforming to Fe 410-W (Gde E-250) quality B complete all as specified and directed.
S&F mild steel work conforming to Fe 410-0 (Grade E-250 quality A) in nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa(AZ not less than 150) as in roof covering/cladding to wall, fixed with self tapping steel screws complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa (AZ not less than 150) as in ridge, roof covering/cladding to wall, fixed with self tapping steel screws complete all as specified and directed.
M & L for two coat of Synthetic enamel paint over a coat of red oxide primer inclung preparation of newly steel surfaces any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M & L Rendering 5mm thick in CM (1:3) on fair faces on ceilling concrete surfaces to be finished even and smooth without using extra cement.
M&L for rendering 15 mm thick in CM 1:4 on brick or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceilling complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coat oil bound distemper over a coat of 1 mm thick wall care putty complete all as specified and directed.
M&L 75mm thick cement concrete 1:3:6 type C-2 (using 20mm graded stone aggregates) as in plinth protection finishing cement concrete even and fair without using extra cement making 10mm wide and 30mm deep joints at each corner and at every 3.00 mtr interval filling the same with mastic filling i.e one part of bitumen 85/25 and 3 part of sand complete all as specified and directed.
M & L for 75mm thick Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for flooring finished even and smooth without using extra cement including laid in alternate bays and provide 38mm width of plastic dividing strips, 1.5 mm thick etc complete all as specified and directed.
M & L for 75 mm thick Cement concrete 1:4:8 type D-2 ( using 40mm graded stone aggregate) as in flooring and lean concrete etc complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering and well ramming etc complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed.
M & L for form work as in sides of columns etc complete all as specified and directed.
M & L for form work as in roof beams etc complete all as specified and directed.
M & L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
M & L for MS TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab flooring in flooring but one piece as in treads of straircase etc over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, over 15 mm thick screed bed or bedding in CM 1:6 for laying floor finishes, complete all as specified and directed.
All as per item No above here in before but on vertical surface as skirting over and incl 10 mm thick rendering as in CM 1:3 to receive Kota stone/slab etc all as specified and directed.
M & L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Providing and laying 80mm thick factory made chamfered edge cemen concrete paver block of M-40 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. etc complete all as specified and directed.
M&L broken stone hard core of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rolled/ rammed to a true surfaces complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping & benching etc complete all as specified and directed.
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed/open PVC rigid conduit medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for One light/fan point controlled by one switch complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
Ditto as above but for One 5 pin 5 Amp socket point on an independent board with 2.5 Sqmm (FRLS) copper conductor cable …... ditto as above…..
Ditto as above but for One 5 pin 5 Amp socket point on same board…... ditto as above…..
Ditto as above but for one 15 Amp 5 Pin switch socket combination independent with 4.0 Sqmm FRLS unsheathed copper conductor single core multistranded …... ditto as above…..
S&F Switch Piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 6A complete all as specified and directed.
S&F Switch socket combination 5 in 1, 15 Amp flush type complete all as specified and directed.
Supply and fixing of fan regulator 120 watts flush type for ceiling fan electronic type stepped range (5 steps) hum free including necessary connections complete all as specified and directed .
S&F ceiling rose PVC/Poly carbonate isolated body three terminal 65/35 mm, AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length. (ii) The quoted rete is deemed to be included for the chases cutting. (iii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.)
Supply and fixing of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 12 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
Supply and fixing of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with alum thimbles as required complete all as specified.
S&F of MCCB 100 Amps, AC, 415 Volt, 4 Pole, 16 KA with thermal magnetic trip unit (TMTU) adjustable thermal setting 0.7 - 1 x In, class II front face, Ics = 100% Icu as per IS/IEC 60947-2 complete all as specified and directed
S&F of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F of MCB SP 10 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing LED lights fitting 4 feet, 20W, 220V, AC batten type with driver, holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose having luminaire lumen >2000 lm complete all as specified and directed.
S&F building security LED Light 30 Watt sensor based made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 25 mm dia 1.2 mtr long bend to shape as required and fixing with two nos MS Clamp of size 25x6 mm for fixing of builiding security light fittings completed all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods (upto 600mm long), electronic regulator and accessories, 230 V, 1200 mm sweep min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and driected.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 35 Sqmm 4 core all as specified and directed
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 4 core all as specified and directed
Sand cushioning to under ground cable in layers of 23cm thick ( 8cm before laying the cable and 15cm after laying the cable) in trenches including punning the sand up to 18cm thick and consolidated complete all as specified and directed. Note: Punned thickness only will be considered for payments
Supply and laying kiln burnt bricks best quality locally available old size sub class 'B' bricks laid flat in trenches with axis of brick perpendicular to the axis of cable for cable protection complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed. Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.
S & F busbar chamber capacity of 200 Amps, 4 way, 4 pole, 50 Hz, 415 Volts, on wall/pole/panel or grouted in foundation with iron stand of suitable size with PCC of 1:4:8 in ground with proper lugs having 4 Nos of aluminium bus bar complete all as specified and directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S&F of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 25 x 4 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed.
S&F of LED 70 Watt powder coated pressure die cast aluminium SMD street light with heat resistant toughened glass with lens complete all as specified and directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and including 40 mm GI pipe for holding LED light and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and all specified and directed.
Supplying & erecting of steel tubular swaged type conforming to IS, specification complete with base plate, welded top cap over all vertical length 9.00 mtr type 410-SP-31 two coat of primer red oxide internally ( exposed to view) and painted internally two coats of bituminous paint through out and externally painting of one coat with aluminium paint including 25 mm GI tubing medium grade complete for mounting of light upto 1.5 meter. Necessary excavation and earth work PCC (1:4:8) type D-2 in foundation and coping with (1:3:6) type C-1 including form work above ground level disposal of surplus soil to a distance not exceeding 50 mtr complete painting with aluminium painting including provision of black and yellow of 05 Nos of 30 CM each strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of poles with feeder location complete all as specified and directed .
GEESR INFRA BUILDERS PVT LTD (BID ID -3333686)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .