| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC | ₹41.0 L Quoted ₹41.7 L | L1 | Accepted-AOC Accepted being L1 bidder |
| 2 | L2₹42.1 L+₹48,160.12 (1.16%)Rejected-Finance | ₹42.1 L+₹48,160.12 (1.16%) | L2 | Rejected-Finance Being L2 bidder |
| 3 | L3₹45.3 L+₹3.6 L (8.71%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | ₹45.3 L+₹3.6 L (8.71%) | L3 | Rejected-Finance Being L3 bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to contractor has not uploaded all copy of EPF only one sheet has been uploaded which is not visible |
Tender Value
₹41.9 L
EMD Value
₹83,780
Closing Date
14 Dec 2022, 6:00 pmClosed
Shri Avinash Mishra IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
CERTAIN REPAIRS TO LT CABLES MAIN FEEDER PILLAR BOX AT AIRFIELD AREA AND REPAIR MAINTENANCE REPLACEMENT OF STREET LIGHT HIGH MAST LIGHT GARDEN LIGHT AREA LIGHT
2022_MES_560044_1
8316/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Charbatia
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹83,780
Yes
4 Feb 2023
27 Oct 2022
16 Dec 2022
27 Oct 2022
14 Dec 2022
10 Nov 2022
27 Oct 2022 - 5 Nov 2022
Amount
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or taking up / down electrical cables / pipe. and getting out in soft/loose soil concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated spoil to a distance n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified and directed. Note- Punned thickness will be measured at the time of measurement and payment.
S&F cable covers Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid in trenches over sand cushioning for cable protection complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in bed plates including necessary formwork, concrete exposed surface shall be finished even and fair without using extra cement complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) kerbs etc including necessary formwork, concrete exposed surface shall be finished even and fair without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping above ground levels including necessary formwork, concrete exposed surface shall be finished even and fair without using extra cement complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq mm 3.5 core complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq mm 3.5 core,including taking down old UNSV cable complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.
Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm 2 core, including taking down old UNSV cable complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 150 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Al conductor cable of size 300 sqmm complete all as specified and directed.
Supply and fix areial bunch cable with insulated messenger conductor of size 1C 16sqmm + 25sqmm (insulated) complete all as specified and directed.
Supply and fix areial bunch cable with insulated messenger conductor of size 3C 16sqmm + 25sqmm (insulated) complete all as specified and directed.
Supply and fix two Nos clamps and J-Hooks for support of areial bunch cable complete all as specified and directed.
Supply and fixing PVC rigid non-metallic of size 25 mm exclusive of boxes(junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, necessary fastening arrangement on PCC/Tubular/Channel pole etc complete all as specified and directed.
S&F in replacement bracket for street light made out of 1.5 Mtr long, 40 mm bore GI tubing, medium grade bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size, including taking down old UNSV bracket complete all as specified and directed .
Supply and fixing in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells) (Note: Necessary manpower/accessories ladder etc required for replacement is ddemed to be included in quoted rate.)
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells) (Note: Necessary manpower/accessories ladder etc required for replacement is ddemed to be included in quoted rate.)
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells) (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate).
S&F 100 W LED flood light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangementcomplete all as specified and directed. (Make:Crompton, Cat Part No-CFS-504-100-57-60D-SL-GL-NSG or equivalent makel of Havells / Bajaj / Philips.) (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate)
S&F 150 W LED flood light/highmast light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangement complete all as specified and directed. (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate). (Make:Crompton, Cat Part No- CFS-501-150-57-60D-SL-GL-NGG equivalent model of Havells / Bajaj / Philips.)
S&F garden light LED fittings 10 watt, inverted pyramid tripod LED bolard with soft 360 degree light, IP 65 protection including taking down old UNSV garden light complete all as specified and directed. (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate). (Make:Crompton, Cat Part- LBLSN-10-CDL or equivalent model of Bajaj / Philips/Havells.)
S&F for street light timer panel including digital timer contactor 65 A TP, 63 A TPN, including taking down old UNSV complete all as specified and directed. Make- Havells, CAT Part No: IHXTS09120 or equivalent in ABB/Legrand.
Taking up or down unserviceable/broken steel tubular pole complete all as specified and directed.
S&F in replacement steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 mtrs long) complete all as specified and directed.
M&L for painting of steel tubular pole surface, 9/11 metre high applying two coats of aluminium paint complete all as specified and directed. Note : Painting to be done till fitting including extended neck or pipe/support as directed.
S&F, PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed. Make: Plaza/ Gloster/Polycab.
S&F 40 mm bore galvanised iron pipes, 'light grade' with all fittings and accessories laid in trenches or fixed to wall / pole including tanking down old UNSV complete all as specified and directed.
S&F 80 mm bore galvanised iron pipes, 'light grade' with all fittings and accessories laid in trenches or fixed to wall / pole including taking down old UNSV complete all as specified and directed.
Supply and fixing in replacement of SMC junction box of size 270mm x 225 mm x 135 mm hinged type door 4 Nos terminal with 6-20 Amp MCB fixing on pole with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc including taking down old UNSV complete all as specified and directed. Make- Sintex or equivalent make approved by GE
Supply and fixing in replacement Manual Rotating Search Light (CS Mounted) for fixing inside watch-tower’s cabin) HPSV 400 Watt 230 V AC complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells/Kalin or other make as approved by GE)
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed.
S&F Earth in replacement continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section, 2 core in service connections including taking down old UNSV service cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section, 2 core in service connections including taking down old UNSV service cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section, 2 core in service connections including taking down old UNSV service cable complete all as specified and directed.
Supply and fix/laying stranded GI wire 7/1.60mm stranded galvanised steel wire in replacement of unserviceable GI wire complete all as specified and directed.
Supply and fix/laying GI wire 4 mm galvanised steel wire in replacement of unserviceable GI wire complete all as specified and directed.
Labour for Repair/ maintenance of street lights/ yard lights/ high mast fitting/ luminaire of any size/ type fixed on poles/bldgs/tower including taking down as required at a height exc. 8m from the ground level including dismantling all the defective components, checking its serviceability circuit board, driver units and carried out necessary minor repairs/soldering of worn out circuits /connections, replacement of unserviceable parts and refixing the same after repair including connecting and testing the same, replacing the fused lamps, burnt out wiring, ballast and igniter, capacitor and reassembling and fixing the fitting to original position complete, testing and commissioningcomplete all as specified and directed . Replacement of fused wire is deemed to be included and other items will be measured and paid separately under relevant items, however securing wiring/ tapeing/refixing is deemed to be included in Job. Note: (a) Irrespective of items repaired/checked and placed back or replaced, the measurement shall be made for one pole as one unit. (b) Attending through necessary ladder arrangement on vehicle or ladders etc shall be arranged by the contractor. (c) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (d) Contractor is completely responsible for the safety of manpower employed by him.
Supply only
18/20 Watt FTL Tube
FTL Tube light Starter
FTL Tube light Ballast
400 Watt MH light
400 Watt MH light Ballast
400 Watt MH Capacitor
Driver unit suitable for LED street light fittings of 90 watts
Driver unit suitable for LED street light fittings of 60 watts
Driver unit suitable for LED street light fittings of 45 watts
MCPCB unit suitable for LED street light fittings of 45 watts
MCPCB unit suitable for LED street light fittings of 60 watts
MCPCB unit suitable for LED street light fittings of 90 watts
Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers as used will be paid separately. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (e) The fuse of call/breakdown and defect identification to be attended immediately within 2 hrs and process for proper defect identification should be completed in continuation alongwith any further workmen or equipment required as defect rectification being essential service in nature and the cost is deemed to be included in scope of work and also as directed. (f) Contractor is completely responsible for the safety of manpower employed by him. (g) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services. (h) A penalties of Rs 500/-per day will be charged as penalty in case of non compliance or non rectification of job, further necessary action as deemed fit will be taken considering the essential E/M services requirement.
Labour for Maintenance and attending breakdown complaints of LT panels/SFUs/Changeover/ Isolator/ Busbar panels/Fuse units/starter/MCCBs/TPN DBs other electrical connectings units alongwith checking/ finding of faults of connected over head lines and under ground LT cables complete circuit from LT connection at terminals of transformer to ACBs/MCCBs of LT panels of sub-stations/feeder pillar box and upto main distribution boards at buildings/OTM, including attending minor repairs/mainetnance of LT panels for smooth and trouble free LT power supply , rectification of minor defects to electrical controls and accessories and attending breakdowns at any time around the clock all as sepcified and directed. Note:- (a) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering or other testing as required for any fault identification and securing/reconnecting cables or connected switch gear after defect rectification is deemed to be included in the scope. (b) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (c) The fuse of call/breakdown and defect identification to be attended immediately within 1 hrs and process for proper defect identification should be completed in continuation as directed. (d) Contractor is completely responsible for the safety of manpower employed by him. (e) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services. (f) A penalties of Rs 500/-per day will be charged as penalty in case of non compliance or non rectification of job, further necessary action as deemed fit will be taken considering the essential E/M services requirement.
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Al conductor cable of size 150 sqmm complete all as specified and directed.
M&L for vegetation/wild grass/bushes clearance in E/M installation area, around feeder pillar boxes, along the UG cables, street light/LT poles for prventive maintenance/break down attendance. Note: (a) The contractor should provide sufficient manpower and machinery as required for immediate preventive/ breakdown services. (b) The contractor should provide all safety gears like helmet, gum boots/ apron etc and safety of the workmen will be responsibility of contractor.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .