Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹40.1 L+₹5.6 L (16.3%)Rejected-Finance AT POST SONAJ TAL MALEGAON DIST NASHIK | MALEGAON | NASHIK | MAHARASHTRA | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹40.1 L+₹5.6 L (16.3%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹40.4 L+₹5.9 L (17.2%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹41.0 L+₹6.6 L (19.0%)Rejected-Finance PLOT NO 21 KANAK VIHAR KANAKPURA NEAR KANAKPURA RAILWAY STATION JAIPUR 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINT OF SEWAGE LINES AREA DRAINAGE AND PAVED AREA IN ZONE B AND C AREA OF AGE BR I CENTRAL UNDER GE C KIRKEE
2020_MES_385386_1
8410/E8 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹80,000
Yes
31 Dec 2020
10 Oct 2020
9 Nov 2020
10 Oct 2020
6 Nov 2020
24 Oct 2020
10 Oct 2020 - 23 Oct 2020
60 days
Amount
M&L for cleaning of all blockage of sewerage of any type sewerage line, branch line, main sewer line etc of any section and that any situation by way of cleaning/ desludging by using manually and mechanically or pumping out sewage from block man hole where required and directed by Engr-in-Charge and keeping the sewer line functional. Cleaning the trap, WC, soil waste, vent pipe, gully traps upto final drop outlet, inlet of septic tank, working in foul condition with taking precautionary measures, equipments and required power / cable all as specified for the working condition as directed.Note : (i) The contractor shall provide 03 Nos trained safaiwala along with Outdoor Non-Motorised drain Cleaners for removing blockages and Outdoor Motorised Drain cleaner machine to AGE B/R-I, GE (C) Kirkee from 0830 hrs to 1700hrs; even on Sundays and holidays to attent emergency complaints. No Extra payment shall be admitted for working on Sundays/holidays. If the contractor fails to provide the man power, the recovery of Rs 500/-per person per day will be made from payment due. (ii) Day-to-day complaints of chocked/Blocked up manholes, sewage lines etc pertaining to area are to be received daily from the complaint cell of the AGE B/R-I (C) Kirkee and entire complaints are to be attended for cleaning on the same day.
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding1.5 mtrs in depth for foundations etc for manhole / for laying of pipe and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, levelling watering and well ramming in layers n exc 25 cm thick (soil) complete all as specified and directed.
Removing excavated material to a distance n exc. 50 mtr and depositing where directed at a level n exc.1.50 mtr above starting point complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware/AC/RCC) set in cement mortar for 150mm to 300mm dia pipe all as directed at site complete all as specified and directed.
M& L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in bed to drain pipe 150 mm bore including forming cradles complete all as specified and directed.
M& L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in bed to drain pipe 200 mm bore including forming cradles complete all as specified and directed.
M& L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in bed to drain pipe 300 mm bore including forming cradles complete all as specifiedd and directed.
M&L for 150 mm dia (internal dia) RCC hume pipe class NP-2 laid and jointed complete with collars laid in trenches as specified and directed.
M&L for 200 mm dia (internal dia) RCC hume pipe class NP-2 laid and jointed complete with collars laid in trenches as specified and directed.
M&L for 300 mm dia (internal dia) RCC hume pipe class NP-2 laid and jointed complete with collars laid in trenches as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified.
Demolition of Brickwork or stone/boulder masonry, built in cement/cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed.
M & L for pre cast cement concrete solid block masonry with solid block of the grade C1 (1:3:6) set in CM (1:6) complete all as specified.
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Racking out joints/pointing to random rubble or polygonal rubble uncoursed or brought up to courses masonry built in cement or lime mortar, complete all as specified.
M & L for taking down cement or cement lime plaster of any description on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces of manholes in CM 1:4 using water proofing compound @ 3% by wt. of cement and finishing even and smooth using extra cement complete all as specified. NOTE :- WPC shall be measured and paid separately.
M& L rendering 15 mm thick on fair faces of brick/block masonry/stone masonry surfaces of boundary wall and drains etc in CM 1:4 using water proofing compound @ 3% by wt. of cement and finishing plastered surfaces even and smooth without using extra cement complete all as specified.
Supply only integral water proofing compound.
M& L rendering 15 mm thick on fair faces of brick/block masonry/stone masonry surfaces in CM 1:6 and finishing plastered surfaces even and smooth without using extra cement complete all as specified.
M& L rendering 10 mm thick on fair faces of brick/block masonry/stone masonry surfaces in CM 1:4 and finishing plastered surfaces even and smooth without using extra cement complete all as specified.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint over a coat of primer complete all as specified.
M & L for providing cement concrete type B-1 (1:2:4) using 20 mm graded crushed stone aggregate as in coping/benching and the like including necessary form work complete all as specified.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, mould, mitered/stopped ends etc (inner girth only measured).
Cleaning of existing septic tank of 500 users capacity by removing water, sludge, stones, solid particles etc complete by cleaning suction equipment and disposing the same through mechanical transport and removing the same out of defence land and burried as directed.
Cleaning of existing septic tank of 50 to 100 users capacity by removing water, sludge, stones, solid particles etc complete by cleaning Mechanical suction equipment and disposing the same through mechanical transport and removing the same out of defence land and burried as directed.
Cleaning of existing septic tank/manhole of 10 to 25 users capacity by removing water, sludge, stones, solid particles etc complete by cleaning Mechanical suction equipment and disposing the same through mechanical transport and removing the same out of defence land and burried complete all as directed.
Demolition of RCC manhole covers including RCC slab set in cement mortar complete all as directed.
M & L for precast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in manhole covers, septic tank slab etc set in CM 1:6 complete all as specified and directed.
M & L for mild steel TMT bar 10mm dia and over cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of PCC in any position not otherwise specifically provided for, as in surface channel, drains, manholes, copings, ground floors and pavings of any description and in any position and removing debris out side MD land complete all as specified and directed by Engr-in-Charge.
Material and labour for 100 mm thick, PCC (1:4:8) type B-2 using 40 mm graded stone aggregates as in sub base complete all as specified.
Material and labour for 75 mm thick, PCC (1:4:8) type B-2 using 40 mm graded stone aggregates as in sub base complete all as specified.
Material and labour for 25mm thick crushed stone dust/sand filling under floors or in foundations including watering and consolidation complete all as directed.
Material and labour for 80mm thick machine pressed glossy finish precast concrete interlocking paver block any shape and size & Colour M-40 grade with grey cement and no pigment confirming to IS 15658-2006 complete all as directed.
Material and labour for 60mm thick machine pressed glossy finish precast concrete interlocking paver block any shape and size & Colour M-35 grade with grey cement and no pigment confirming to IS 15658-2006 complete all as directed.
M & L providing 40mm thick plain cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in floor etc finished even & smooth without using extra cement complete all as directed.
M & L for glass dividing strips 3mm thick and 38mm width inserted in position complete all as specified.
Material and labour for PCC 1:2:4 type B2, including necessary formwork using 40mm graded crushed stone aggregate, as in surface channels and drains etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engr-in-Charge.
M & L for PCC 100 mm thick 1:2:4 type B2 as in hardstanding/floor (using 20mm graded stone aggregate) finished even & smooth without using extra cement complete all as directed.
Finishing surface of concrete by brooming with brooms whilst concrete is green complete all as specified and directed.
Material and labour for screed bed or bedding layer of mortar 20mm thick average thickness for laying floor finishes in cement mortar 1:6 complete all as specified.
Material and labour for coloured glossy finish chequered cement concrete tiles of size 30 cm x 30 cm x25 mm thick with grey cement and pigments, set jointed and pointed in neat cement slurry in floors over existing screed bed complete all as specified and directed.
S & F in cast iron(sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches or in floors or fixed to walls, bore of pipe 100mm including taking down old CI pipe complete all as directed.
S & F in cast iron(sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches or in floors or fixed to walls, bore of pipe 75mm including taking down old CI pipe complete all as directed.
S&F in repairs cast iron bends (any radius) or diminishing pieces larger bore measured bore of pipe in 100 mm fixed fitted with oval access doors complete all as specified.
S&F in repairs cast iron bends (any radius) or diminishing pieces larger bore measured bore of pipe in 75 mm fixed fitted with oval access doors complete all as specified.
S & F in of 110 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches, floor and wall including taking down old unserviceable pipe any description and any type complete all as specified.
S & F in PVC (SWR) Pipes single socketed in any length with rubber ring joints laid in trenches or in floors and wall 75mm bore including taking down old unserviceable pipe any description and any type complete all as specified.
S&F 110mm dia (bore of pipe) PVC bends (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.
S & F in repairs PVC (SWR) bends 75mm dia bore any radius with access door all as specified and directed.
S & F in repairs PVC (SWR) branch piece, single (single Y) 110 mm dia equal or unequal all as specified and directed.
S & F in repairs PVC (SWR) branch piece, single (single Y) 75mm dia equal or unequal all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) junction single (Single T) equal or unequal all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) vent cowl all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl all as specified and directed.
MAHESH DADAJI BACHHAV
Shri Sant Cosntruction
V.R.PRAJAPATI AND CO.
M/s ESS KAY Construction
S.R.M.K Enterprises
L.K.R.TIWARI CONSTRUCTION
Veekay Enterprises
Om Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .