Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 CrAccepted-AOC | ₹5.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.8 Cr+₹16.1 L (2.87%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹5.8 Cr+₹16.1 L (2.87%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹6.0 Cr+₹40.7 L (7.27%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | ₹6.0 Cr+₹40.7 L (7.27%) | L3 | Rejected-Finance Not L1 |
| 4 | L4₹6.0 Cr+₹40.7 L (7.28%)Rejected-Finance | ₹6.0 Cr+₹40.7 L (7.28%) | L4 | Rejected-Finance Not L1 |
| 5 | L5₹6.5 Cr+₹90.9 L (16.2%)Rejected-Finance | ₹6.5 Cr+₹90.9 L (16.2%) | L5 | Rejected-Finance Not L1 |
Tender Value
₹5.8 Cr
EMD Value
₹6.2 L
Closing Date
6 Sept 2022, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
ADDN/ALTN TO VARIOUS BUILDINGS (OTM ACCN) AT HISAR MIL STN
2022_MES_540727_1
CEJZ/NIT/HSR-03 OF 2022-23
Open Tender
Civil Works
Item Rate
330 days
HISAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (West) Hisar
₹6.2 L
Yes
29 Sept 2022
25 Jul 2022
8 Sept 2022
25 Jul 2022
6 Sept 2022
25 Aug 2022
Amount
Taking down cement plaster on brick / stone wall, ceiling etc incl. raking outs joints hacking for key scrubbing with water complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed .
Demolition of RCC in floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work, including removing out of MD Land complete all as specified and as directed
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level), including removing out of MoD Land complete all as specified and as directed
M&L for rendering 10 mm thick on brick masonry surfaces in CM(1:6) finished even and smooth with out using extra cement complete all as specified and as directed Note : Unit rate of this item includes for making groove of size 10mm wide and 12mm deep at junction of RCC & masonary.
M&L rendering 15mm thick on other face of brickwork surfaces in CM 1:4 surface finished even and smooth without using extra cement but using liquid water proofing compound as per manufacturer instructions complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid seperately. (ii) Unit rate of this item includes for making groove of size 10mm wide and 12mm deep at junction of RCC & masonary.
M&L for rendering 10 mm thick on ceiling in CM(1:3) finished even and smooth without using extra cement complete all as specified and as directed.
M&L joint free Non Skid ceramic tiles(coloured) 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set over and including 15mm thick screed in CM 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as pecified and as directed.
M&L glazed ceramic coloured tiles ( 450mm x 300 mm) x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps ,wall etc set over and including 10 mm thick cement plaster in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Taking up or down steel tubing and connection of 15 mm bore complete all as specified and as directed.
S&F 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F brass threaded CPVC Elbow for CPVC pipe outer dia 20mm complete all as specified and directed.
S&F brass threaded CPVC Tee for CPVC pipe outer dia 20mm complete all as specified and directed .
S&F male/female brass threaded Adaptor (MTA/ MBTA) for CPVC pipe outer dia 20mm complete all as specified and directed .
Taking up or down steel tubing and connection, including cleaning 20 mm bore complete all as specified and as directed.
M&L GI tubing medium grade with all fitting 20 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor complete all as specified and as directed.
S&F as in repair fancy type Chromium plated stop valves (consealed type), angle valve cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 15 mm bore fixed complete all as specified and as directed.
S&F as in repair bib taps/fancy type chromium plated 15mm dia cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule over and including extension piece and CP cap complete all as specified and as directed.
S & F as in repair PVC connections 15mm size with PTMT nuts of length, 450mm complete all as specified and as directed.
S&F as in repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule 20mm complete all as specified and as directed.
Dismantling water tanks any type ,exc 500 litre and not exc 1000litre complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I - Capacity 1000Litre (White colour) complete all as specified and as directed.
S&F as in repair PVC low level flushing cistern 10 litre capacity, syphonic action type with float valve, handle including 32mm dia flush pipe of polyethylene of low or high density of required length and shape including PVC bracket etc complete all as specified and as directed.
S&F as in repair vitreous china squatting pan "ORISSA" pattern size 580mmx 440mm, white with integral foot rest including CI/PVC 'P' or 'S' trap and WC Connector/short piece of pipe connection to trap including and to flushing pipe, anti-syphonage pipe, etc. , complete all as specified and as directed.
S&F as in repair vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) with PVC sheet cover & 'P' OR 'S' trap complete all as spefied and as directed.
S&F as in repair Vitreous China bowl urinal flat back, size of 465mm x 355mm x 265 mm white (minimum), with grating, waste pipe and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
S&F as in repair cromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union ,125mm size complete all as specified and as directed.
M&L Cement concrete filling and mass concrete in suken portion PCC 1:5:10 type E-2 ( 40 mm graded aggregates ) complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified.
S&F band straps supports or stays for rainwater, ventilating pipes incl bolts as required, clamps, hold fasts and similar articles confirming to Fe 290 Gde E-165 complete all as specified and as directed .
S&F as in repair PVC (SWR) floor trap plain with CP grating including jointing with solvent cement diameter of outlet 75 mm complete all as specified and as directed.
Taking down chowkats or frames with shutters not exc 1.50 Sqm each (without taking off shutters from the frames) complete all as specified and as directed..
Taking down chowkats or frames with sutters exc 1.5 sqm but not exc 4.00 sqm each (without taking off shutters from the frames) complete all as specified and as directed..
Taking down sutters exc 1.0 sqm but not exc 2.00 sqm each complete all specified and as directed.
S & F for pressed steel frames of size 125mm X 60 mm with one or more rebates including necessary fixing lugs, butt hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all as specified and as directed.
S & F for pressed steel frames of size 105mm X 60 mm with one or more rebates including necessary fixing lugs, butt hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20mm Graded Stone Aggregate) as in filling of Chowkhats complete all as specified and as directed.
S&F factory Made Pressed steel window (Box type) with side hung shutter with glazing bar to receiving glass, dovetailed or welded with and including necessary welding, riveting , tower bolt, Handle, Hold fast, Hinges and steel peg stay as per TD Drg No. CEJZ/TD-2013/01 sheet 1/3,2/3,3/3 including one shop coat of red oxide primer complete all as specified.
S&F factory Made Pressed steel window (Box type) with side hung shutter without glazing bar but including sash bar to receiving wire gauge, dovetailed or welded with and including necessary welding, riveting , tower bolt, Handle, Hold fast, Hinges and steel peg stay as per TD Drg No. CEJZ/TD-2013/01 sheet 1/3,2/3,3/3 including one shop coat of red oxide primer complete all as specified.
S&F factory Made Pressed steel Ventilator (Box type) with Top hung shutter to receiving Glass/wire gauge, dovetailed or welded with and including necessary welding, riveting , tower bolt, Handle, Hold fast, Hinges and steel peg stay as per TD Drg No. CEJZ/TD-2013/01 sheet 1/3,2/3,3/3 including one shop coat of red oxide primer complete all as specified.
M&L framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, chajja, cooler stand and similar work conforming toFe-290(Gde E-165) complete all as specified and as directed.
M&L sheet glass ordinary quality and glazingwith oil puttyin square n.exc 0.50 sqm in each pane in 3 mm thickness complete all as specified and as directed.
Hacking out old broken glass any thickness, size, quality from steel frames glazed with putty.
M&L solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing.
M&L factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
M&L 35mm thick factory made plain, framed, paneled door shutters kiln seasoned and chemically pressure treated second class, hardwood (two panels) with lock rail and panel of 9mm thick BWP commercial marine grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive confirming to IS-710 including one shop coat of pink primer. The size of rails and style shall be as per IS-1003. The shutter shall be fitted to chowkhats complete all as specified and as directed.
S&F 35mm thick factory made second class hardwood glazed and skelton door shutter kiln seasoned and chemically treated, open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete. The size of members of shutters shall be as specified in MES SSR Part-I including one shop coat of pink primer. The shutter shall be fitted to chowkhats complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section and fixed 150 mm complete all as specified and as directed.
S&F as in repair Aluminium anodised barrel tower bolts of extruded section and fixed 150 mm complete all as specified and as directed.
S&F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clip of sheet,cast or extruded section, bolt not less than 16 mm dia, 300 mm long.
S&F as in repair aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clip of sheet,cast or extruded section, bolt not less than 16 mm dia, 300 mm long.
S&F butt hinges, medium weight, cold rolled stainless steel, and fixed 100 mm complete all as specified and as directed.
S&F aluminium handles extruded fabricated type anodized of size 125mm complete all as specified and as directed.
S&F as in repair aluminium handles extruded fabricated type anodized of size 125mm complete all as specified and as directed.
S&F stainless steel wire gauge 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F as in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed
S&F as in repair 20mm dia , mild steel, chromium plated curtain rod with fixing brackets, stops, rollers etc. complete all as specified and as directed.
M & L for preparation of new plastered wall surfaces and applying two coat of oil emulsion distemper of any tint over a coat of wall care putty 1mm thick complete all as specified and as directed.
M & L for removal of existing treatment of plastered wall surfaces and applying two coat of oil emulsion distemper of any tint over a coat of wall care putty 1mm thick complete all as specified and as directed.
M&L for preparing new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed
M&L for preparing old plastered surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparing old wooden surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparing new wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing old steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for two coat or more coat of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004.alkali&fungle resistance dirt resistance exterior paint of required shade with silicon [email protected]/10 sqm over and including priming coat of exterior primer [email protected]/10 sqm over new surface complete all as specified and as directed.
M&L for two coat or more coat of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004.alkali&fungle resistance dirt resistance exterior paint of required shade with silicon [email protected]/10 sqm over and including priming coat of exterior primer [email protected]/10 sqm over old surface Including complete removal of existing Treatment complete all as specified and as directed.
M&L 50 mm thick plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregates) as in plinth protections with finished even and fair including making groove at 3m interval and filled with bitumen sealing compound complete all as specified and as directed.
S&F as in reapair 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S & F as in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F as in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F as in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F as in repair PVC Bends 110mm bore, with oval access doors complete all as specified and as directed.
S&F as in repair 110 mm bore. PVC (SWR) junction single,(Single T) equal or unequal with access door complete all as specified and as directed.
S&F as in repair PVC Bends 75 mm bore, with oval access doors complete all as specified and as directed.
S&F as in repair PVC (SWR) vent cowl 110mm complete all as specified and as directed.
M&L for brickwork with old size flyash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed.
M & L brick work with old size flyash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L machine cut Kota stone slab flooring 20-25 mm thick over and including 15 mm thick cement screed base laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. Note : For staircase treads and window cill etc, kota stone shall be laid in one peice upto 1.50m length.
M&L Kota Stone Slab 20-25 mm thick in riser of steps , skirting , dado and pillar laid over and including 15 mm thick cement plaster in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Demolition Mud in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) complete al as specified and as directed.
Demolitin of Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed.
M&L cement concrete 1:2:4 mix type B-1 (20 mm graded stone aggregate) in padding all as specified of average thickness 50 mm in slope over roof complete all as specified and as directed.
M&L for screed bed or bedding layer or mortar 15mm thick in cement mortar 1:4 with WPC on roof surfaces complete all as specified and as directed. Note :- WPC shall be measured and paid seperately.
M&L for providing 10mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30%) over slab with and including supplying and applying fibre, reinforced UV resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers & polyester/glass fibres. The operation shall be carried out after scrapping and properly cleaning the surface too remove loose particles with wire brushes, complete all as specified and as directed.
S&F as in repair gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed for 20mm dia pipe (ISI Marked) complete all as specified and as directed.
S&F 300mm ordinary helical door springs incl roller & roller plate complete of mild steel complete all as specified and as directed.
S&F as in repair 300mm mild steel ordinary helical door springs incl roller & roller plate complete all as specified and as directed.
S&F as in repair salt glazed stone ware gully traps square or rounded mouthed type P or S of size 150cm x 150cm incl excavation earth work conc in Beds, surrounds kerbs etc complete all as specified and as directed.
Demolition and breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete pipes) 150mm internal dia set in cement mortar complete all as specified and as directed.
S&F Reinforced concrete pipes, class NP3, laid and jointed complete 150mm dia laid in trenches and jointed in cement complete all as specified and as directed. Note:- Excavation , earthwork and bedding shall be measured and paid seperately under respective item of BOQ.
M&L concrete bed in PCC 1:4:8 type D-2 to drain pipes of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire 0.9 mm dia complete all as specified and as directed.
All as per item No 95 above but 6 to 8mm dia complete all as specified and as directed.
All as per item No 95 above but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.6 to 8mm dia complete all as specified and as directed.
M&L form work to chullah hoods, chajjas, troughs and similar items including edges finish with rough finish flat surface complete all as specified and as directed.
M&L RCC 1:1.5:3 type A1 using 20mm graded aggregate as in as in Chajjas, slab etc complete all as specified and as directed.
M&L for Providing precast cement concrete type B-I 1:2:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs,mangers, shelves and similar articles with plain face set in cement mortar 1:4 complete all as specified and as directed.
M&l for cutting holes into or through brick walls built in cement mortar and making good in cement concrete 1:2:4 type B-l as required superficial area exc 150 Sqcm and n.exc 400 Sqcm complete all as specified and as directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Cement concrete 1:2:4 type B2 in foundations, filling and mass concrete complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removing out of MoD Land
S&F 25mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F 100mm Hasp and staple, safety type, aluminium with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F as in repair 100mm Hasp and staple, safety type, aluminium with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F as in repair fancy type chromium plated Angle valves, cast copper alloy with cruitch or butterfly handles screwed down high pressure, screwed both ends for 15mm bore iron pipe or brass ferrule.
S&F PVC (SWR) single junction 'T' 75 mm bore with access door any radius complete all as directed.
S&F PVC (SWR) single junction 'T' 110 mm bore with access door any radius complete all as directed.
S&F PVC (SWR) bends 110 mm bore without access door of any radius complete all as directed.
S&F PVC (SWR) bends 75mm bore without access door of any radius complete all as directed.
M&L for cement concrete (1:2:4),type B-1 using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
S&F 50mm dia PVC pipe, 600mm long as in spout pipe for sunken of toilets complete all as specified and directed.
M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. Note:- Excavation shall be done through manually not mechanically.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm soft/loose soil complete all as specified and as directed..
M&L for removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed..
Chipping of loose/ damaged / cracked / previously repaired/ delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed. NOTE : Item No 118 to 133 shall be executed by authorized applicator of manufacturer as approved by accepting officer)
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg/ltr at 30°C and consumption : 0.2 kg/Sqm/coat complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar
Supply and apply cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer’s specification including prepartaion of surface throughly and cleaning complete where ever required with using Product : Sikadur®-32 LP of Sika or equivalent in Fosroc /Thermax as approved by GE with consumption : 0.4 kg/Sqm and Product requirements : Comp with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and as directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and as directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructionscomplete all as specified and as directed.
M&L for Providing, fixing shear connector of 10 mm dia TOR steel upto 160 mm length with Sika anchorfix @ -2+ Tropical or equivalent make in Fosroc / Thermax as approved by GE, epoxy resin to RCC member including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufacturer’s instructions complete all as specified and as directed.
M&L for cutting V groove (15mmx10mm) along the crack line and cleaning the same with high pressure water jet and sealing with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents using Sikadur 31 of Sika or equivalent make in Fosroc / Thermax as approved by GE as per the technical specifications and manufacturer's instructions complete all asspecified and directed.
M&L for providing and fixing 12-16mm dia injection ports non returnable nozzle by drilling cleaning and sealing holes 50-75 mm deep at 200mm c/c with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents using Sikadur 31 of Sika or equivalent make in Fosroc / Thermax as approved by GE as in beams, columns and parapets as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for grouting of nozzles with low viscous moisture insensitive, High strength, epoxy resin grout with Sikadur 52 LP (IN) of Sika or equivalent make in Fosroc / Thermax as approved by GE with pressure not exceeding 2-3 kgf/Sqcm till the nozzle refuses to take further grout including cutting extra length of the nozzle after the grout hardens and finishes as per the technical specifications and manufacturer's instructions complete all as specified and as directed.
Supply and apply a ready to use non shrink, cementitious free flow microconcrete (<100 mm) using Product : SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and as directed.
M&L for providing and application of one coat of Water based concrete curing compound with low viscosity wax emulsion using Sika Antisol E - WP of Sika or equivalent make in Fosroc / Thermax as approved by GE, as concrete curing membrane over the applied polymer mortar as temporary curing membrane as per the technical specifications and manufacturer's instructions complete all as specified and as directed.
Providing and erecting hydraulic & manual steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required and as directed. Note : Hydraulic & manual steel props will be provided, erected and maintain the interval distance of steel props c/c at site on the basis of site reqmt as per direction of Garrison Engineer and Engr-in-Charge.
M&L for weld-mesh of size 75mmx75mmx3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture SIKA Plasto creat plus or equivalent make in Fosroc / Thermax as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. the gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions and as directed .
Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement and as per directions .
M&L for treatment of sunken floor slab comprising of the following specifications complete all as specified and directed :- Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout. Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thermax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out. All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty Sikagard 694 F (I) or equivalent make in Fosroc / Thermax as approve by GE. After drying putty, wash the slab and sides of sunken portion with water andmake it clear and clean complete all as specified and as directed..
Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc / Thermax as approved by GE in two coats @ 3kg/sqm to sandwiched with glass fibre reinforcement : Sika® Fab-1 or equivalent make in Forsro / Thermax as approved by GE over base coat as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat Plus or equivalent make in Fosroc / Thermax as approve by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan shall be paid separetely).
Taking down carefully copper/ Aluminium point wiring ( light, fans, socket, power socket) complete incl taking out existing unserviceable terminal boxes and conduit with swithces/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB etc complete all as directed. Note:- Unit rate of this item also include the cutting, chasing of concrete/btick work/stone masonry etc and making good disturbed surface of wall/floor and nothing extra shall be admissible on his account.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully DB’s /TPN / Main switch including old unserviceable MCCBs/MCB, isoltaors e tc and making good to disturbed surfaces complete all as specified and directed.
Taking down carefully copper/aluminium Sub main wiring of any size including two runs copper wire and one run of earth wire from /concealed/existing conduit of any size height and removing materials at site and making good disturbed surfaces of wall, floors, roof etc complete all as specified and directed
Material and labour for point wiring one light point controlled by one, one way switch with 1.5 sqmm FRLS single core PVC insulated and unsheathed multistranded copper conductor and incl PVC rigid non metallic concealed conduit 20/25 mm dia medium duty, ISI marked to be terminated in pressed steel terminal boxes with 3mm thick bakelite sheet top cover incl 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multisrtaned copper earth continuity conductor controlled by one switch and or one regulator complete including repairing the surfaces in Cm 1:3 and finishing the surface as per exisitng treatment all as specified and as directed
All as per item No 137 (here-in-before) but One ceiling fan/Exhaust Fan point controlled by one nos, one way switch
All as per item No 137 (here-in-before) but One three pin 5 Amp socket outlet point on indep board controlled by one nos, one way switch on indep board
All as per item No 137 (here-in-before) but One three pin 5 Amp socket outlet point on Same board controlled by one nos,
All as per item No 137 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board.
S&F switch piano flush type, single pole, one way, 5/6 Amp 230 volts all as specified and directed
S&F switch piano flush type, single pole, one way, 15 Amp 230 volts all as specified and directed
S&F flush type socket outlet multipurpose 3 pin 5 Amp flush type 230 volts AC complete all as specified and directed
S&F flush type socket outlet multipurpose 3 pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insulated body with back plate suitable for batten fittings and complete all as specified and directed
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals ISI marked with back plate etc complete all as specified and directed
S&F as in replacement of ceiling fan regulator electronic step type of suitable wattage 230V suiatable for 1200/1400 mm sweep ceiling fan etc complete all as specified and directed
S&F highly efficient LED bulbs, 9 watts in B-22 capacity complte all as specified and directed.
S&F wall mounted LED tube fitting 20 watts batten not less than 120 lumen/watt for surface mounted anodized extruded aluminium housing high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregrated electronic drive connector block etc with warranty option of 5 years from date of intallation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make Bajaj Cat Part No BCLAB 20W WH LED P. Wipro Cat Part No LL20-281-XXX065-ALI or equvalentcat part No. of Make as specified in Appendix 'B'.
S&F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminarire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make : Bajaj Cat No BIBWP 10W LED or equvalent Car Part No of Make as Appendix 'B'.
S&F of Sheet metal enclosure distribution board SP&N,8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar complete all as specified and directed.
S&F Sheet metal enclosure distribution board VTPN,4 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed .
Supply and fixing MCBs SP 6 to 32Amps, 240 volts, 10 KA rupturing capacity, 'B' curve, IS-8828 marked complete all as specified and as directed. Note:- (i) DBs will be measured and paid separately in respective item of BOQ. (ii) Make of the MCB should be the same as that of DB.
Supply and fixing MCBs SPN 32Amps to 63 Amps, ' 240 volts, 10 KA rupturing capacity,B' curve, IS-8828 marked complete all as specified and as directed. Note:- (i) DBs will be measured and paid separately in respective item of BOQ. (ii) Make of the MCB should be the same as that of DB.
Supply and fixing VTPN MCCBs FP 63 Amps, 415 volts, 16 KA rupturing capacity, IS-8828 marked and fixing in VTPN . Note: VTPN will be measured and paid separately in respective item of BOQ.
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source not less than 120 lumen/watt and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 1.5 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including 40 mm dia GI pipe medium grade bracket 1.5 mtr long bend to requred shape with clamps, nut bolts compltete all as directed . Make : Bajaj Cat part no ENXT P 24L WH CR PC SD (Edge plus series) or its equivalent in philips, Wipro
M&L Sub main wiring of size two runs of 6 Sq mm size main cable and one run of 6 Sq mm size earth continuity conductor with single core PVC insluated but unsheathed FRLS cable with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn-through and including suitable size stove enameled rigitd steel conduit and fittings / accessories, all concealed in the wall / ceiling and also including the specified runs of specified size earth continuity conductor of similar type cable complete all as spcififed. (Note :- Two runs of 6 Sqmm copper wire and one run of 6 sqmm copper earth wire alongwith conduit shall be meausred as one unit)
Taking down Exhaust fan, ceiling cable end, dismantiling blades and removing fan and blades to store complete all as specified and as directed.
Re fixing only Exhaust fan any make or any size and after rewinding, servicing,painting of exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust including making of exhaust fan motor etc complete all as specified and as directed.
M&L as in repair earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI earth wire 4 mm dia bolted (with GI nuts, bolts & check nuts) and rivetted to earth (Plate) electrode at one end and connected to main switch board / DB at the other, earth wire protected by and incl GI pipe 15 mm bore (medium grade) from top of electrode to main switch board and also incl watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover,earth work etc all as shown on electrical plate No 3 of SSR - 2009 Part I. Note:-(i) The concrete pit shall be of PCC 1:3:6 type C-1, 40 mm thick pre-cast cover slab of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate with suitable handle shall be provided in lieu of cast iron cover shown in. (ii) Item includes the cost of GI pipe for protection of GI earth wire including copper earth strip up to 7.5 meter. (iii) Any variation of of GI pipe and GI earth wire below or above 7.5 m shall be adjusted through deviation. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Taking down ceiling fan, sealing cable end, dismantiling blades and removing fan and blades to store complete all as specified and as directed.
Re fixing only ceiling fan any make or any size and after Rewinding, servicing,painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust including making of ceiling fan motor etc. complete all as specified and as directed.
Taking out the old unserviceable LT underground cable any size1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole of following sizes etc complete all as specified and directed. Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately
Supply and lay cable XLPE insulated armoured heavy duty electric cable LT 1100 volts grade with aluminium conductor of size 25 Sqmm,4 core complete all as specified and as directed. Note:- Brick protection and sand cushioning measured and paid seperately.
Supply and lay cable XLPE insulated armoured heavy duty electric cable LT 1100 volts grade with aluminium conductor of size 35 Sqmm,3.5 core complete all as specified and as directed. Note:- Brick protection and sand cushioning measured and paid seperately
M&L for bricks covering to under ground electric cable using sub class 'B' bricks laid dry, flat perpendicular to the direction of the cable complete all as specified and directed
M&l for sand filling in trenches with clean dry fine sand unwashed 8 cm thick before cable laying and 15 cm after cable laying incl gently punning around cables complete all as specified and directed.
M&L GI tubing light grade 40mm bore ISI Marked for cable protection fixed to poles under floor/ground complete with all fitting all as specified (clamps to be measured and paid for separately)
M/S BUDHRAM BISHNOI
ABHOG INFRASTRUCTURE PRIVATE LIMITED
M/S Sulakh Brothers
M/S RAJINDER SINGH
Siya constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .