Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | ₹24.3 L Quoted ₹24.8 L | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria |
| 2 | L2₹25.2 L+₹42,800.90 (1.73%)Rejected-Finance NO E 193 12TH CROSS ROAD 3RD STREET PERIYAR NAGAR CHENNAI 600 082 | CHENNAI | TAMIL NADU | 600082 | ₹25.2 L+₹42,800.90 (1.73%) | L2 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Mar 2022, 6:00 pmClosed
GE Chennai
Garrison Engineer Fort Saint George Chennai
REPAIRS TO ROOF TREATMENT AT ZONE B AND E AREA UNDER GE CHENNAI
2022_MES_507743_1
8575/E8
Open Tender
Civil Works
Item Rate
183 days
Fort Saint George
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Chennai
₹50,000
Yes
14 May 2022
12 Feb 2022
18 Mar 2022
12 Feb 2022
12 Mar 2022
26 Feb 2022
Amount
BOQ UPLOADED ON 12 FEB 2022
Supply only PIDI PROOF LW liquid water proofing compound conforming to IS: 2645-2003 all as specified and directed.
M&L precast reinforced cement concrete (1:1½:3) type A-1 using 20mm graded stone aggregate as in base slab for overhead tank on terrace and set in cement mortar (1:6) complete all as specified and directed.
M&L for brick work straight or curved on plan exceeding 6 metre mean radius using old size fly ash bricks built in cement mortar (1:4) all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in flooring/ padding to maintain the possible slope and finishing the top surfaces fair and even complete all as specified and directed.
M&L 100mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in slab for fixing DTH dish over roof slab finished fair and even complete all as specified and directed.
M&L rendering 10mm thick in cement mortar (1:3) mixed with PIDI PROOF LW compound @ 200ml per bag and finishing the surface fair and even on concrete surface as on roof/ terrace complete all as specified and directed. Note: Supply only of water proofing compound shall be measured and paid for separately.
M&L for APP based polymeric membrane 3mm thick and weighing not less than 3.6 Kg/Sqm reinforced with polyster non woven fabric (weight not less than 150 g/ Sqm) laid by torch application using gas burner with minimum 100mm overlap over and including one coat of bitumen primer @ 0.40 ltr/sqm and finished with two coats of solar reflective aluminium paint @ 0.10 ltr/sqm per coat etc. including including carrying out ponding test complete all as specified and directed.
M&L mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed.
S&F galvanised steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed.
S&F galvanised steel water tubing 20mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed.
S&F galvanised steel water tubing 25mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed.
Taking up or down the existing GI water tubing 15mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
Taking up or down the existing GI water tubing 20mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
Taking up or down the existing GI water tubing 25mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
S&F 500 ltr capacity three layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing OHT complete all as specified and directed.
S&F 1000 ltr capacity three layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing OHT complete all as specified and directed.
S&F gun metal gate/ globe valve of size 20mm bore confirming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe complete including taking down the existing unserviceable gate valve complete all as specified and as directed.
S&F gun metal gate/ globe valve of size 25mm bore confirming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe complete including taking down the existing unserviceable gate valve complete all as specified and as directed.
S&F in repairs ball brass valve for 20mm bore pipe high pressure with polyethylene high density float and complete screwed for iron pipe complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F PVC (SWR) bend any radius with access door suitable for 110mm dia pipes complete all as specified and directed.
S&F in repairs PTMT grating doom 125mm dia as per Cat No. 112 of Prayag or equivalent from other makes specified in particular specifications complete all as specified and directed.
S&F in repairs 32mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm² fixed complete to walls, ceilings or in floors etc. including all pipe fittings such as ends, elbows, unions, tees, reducing tees, adaptors, sockets, plugs, hose clips etc. complete all as specified and directed.
Demolition of brick masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facings, dressed stone work including removal of rubbish outside MD land complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish off the premises to outside MD land, complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including separating, scraping of reinforcement and removing rubbish off the premises to outside MD land, complete all as specified and directed.
Demolition of stone slabs and HP tiles of any description or thickness including bedding mortar in roof laid, bedded and pointed in any mortar including cleaning the surface with wire brushes and removing the debries outside MD land complete all as specified and directed.
KS CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .