Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.1 LAccepted-AOC | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹36.0 L+₹2.0 L (5.86%)Rejected-Finance | 2 | Rejected-Finance Not L1 Bidder | |
| 3 | 3₹36.6 L+₹2.6 L (7.66%)Rejected-Finance | 3 | Rejected-Finance Not L1 Bidder | |
| 4 | 4₹37.5 L+₹3.5 L (10.3%)Rejected-Finance 33 1 1 GOALAPARA ROAD P O AUTHPUR DIST NORTH 24 PARGANAS KOLKATA 743128 WB | KOLKATA | NORTH 24 PARGANAS | WB | 743128 | 4 | Rejected-Finance Not L1 Bidder | |
| 5 | 5₹38.2 L+₹4.2 L (12.3%)Rejected-Finance 35 P C MUKHERJEE STREET PO KONNAGAR DIST HOOGHLY PIN 712235 | KONNAGAR | HOOGHLY | WEST BENGAL | 712235 | 5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹30.8 L
EMD Value
₹61,600
Closing Date
7 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
ADDN ALTN AND SPL REPAIRS TO BLDG NO SP 111 AND SP 112 SINGLE LIVING ACCN FOR ORS OCCUPIED BY MES PLATOON AND ESCORT PLATOON OF ESD KANKINARA UNDER GE NORTH KOLKATA
2023_MES_581315_1
8216/22-23/GE(N)/KOL/ OF 2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
ESD KANKINARA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹61,600
Yes
22 Mar 2023
16 Feb 2023
8 Mar 2023
17 Feb 2023
7 Mar 2023
1 Mar 2023
Amount
Dismantling of wall and ceiling boards ( fibre , pulp ,insulation etc ) or insulation boards /slabs/blankets , any thickness , including cover fillets complete all as specified and directed.
Supply and fix anodized aluminium snap grid frame work (size of grid 605x605mm) for false ceiling including suspenders / hangers 6mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof sheds by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm ling and expansion hold fasteners 12.5 mm dia 40 mm long, complete all as specified and directed.
Supply and fix of 6 mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Material and labour for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc. 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles (300x200) x7mm thick in skirting/dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Surface dressing n exc 15 cm deep in soft loose soil complete all as specified and directed.
M&L for chequered cement concrete tiles 200 x 200 x 25mm thick over 20mm thick screed bed or bedding layer of mortar in CM (1:6) for laying floor finishes set jointed with grey cement and pointed in neat cement slurry in floors complete all as specified and as directed.
Material and labour for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and directed.
Material and labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. Note : Only punned down thickness shall be measured and paid.
Material and labour for Cement concrete 100mm thick type B-1, 1:2:4 (20mm graded aggregate) as in floors complete all as specified and as directed.
Dismantling Asbestos cement / Transluscent ( Corrugated , semicorrugated etc.) sheets as in Roof covering , wall , ridge , hips valleys and flashings etc for the building structures not exceeding 10 m height from the average ground level complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Supply and fix Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade Fe 410 -W (Gde?E- 250 quality?A? painted one shop coat of zinchromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
Supply and fix Rolled sections grade Fe 410 -W (Gde?E- 250quality?A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
Supply and fix Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet for ridge 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of brickwork built in cement mortar complete all as specified and as directed.
Material and Labour Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for Providing precast cement concrete type B1 1:2:4 (using 20mm aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with ma?sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham?fers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and directed.
Material and labour for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Material and labour for TMT bars 08mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar complete all as specified and as directed.
Material and labour for PCC 1:3:6 Type C-1 ( using 20 mm graded stone aggregate ) as in surface channel complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm complete all as specified and as directed.
Material and labour for rendering 15 mm thick on fair faces of brick wall or concrete surface (for internal surface of drain ) in cement mortar 1:3 mixed with intgral water proofing compound as per manufacture instruction and finished even and smooth with using extra cement complete all as specified & directed.
Taking down cement plaster on brick or stone wals, etc. including raking out joints, hacking for keys, scrubbing down with water, etc. complete all as specified and as directed .
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour for 20 mm thick rendering with CM 1:4 in two layer , 10 mm thick in each layer and mixed with integral water proofing liquid admixture on top layer of external surfaces of brick work or concrete surfaces including finish the surface even and fair complete all as specified and as directed (Water proofing liquid admixture shall be measured and paid separately)
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over 3mm thick wall care putty on wall complete all as specified and as directed.
Complete removal of existing treatment on plastered surfaces of walls including washing, rubbing down and stopping of old treatement and material and labour for applying two coats of oil bound distemper over a coat of alkali resistant primer to walls etc complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Complete removal of existing treatment on plastered surfaces of walls including washing, rubbing down and stopping of old treatement and material and labour applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Taking down Chowkhats or frames exc 1.50 Sq.m but not exceeding 4.00 Sq.m each (without taking off shutters from the frame) including all fittings complete all as specified and directed.
Supply and fix 35mm thick 2nd class hard wood factory made plain framed panelled door shutters, (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneered on both faces and rail and stiles as per IS 1003(Pt-I), kiln seasoned and chemically pressure treated etc. complete all as specified and as directed.
Supply and fix 35mm thick 2nd class hard wood glazed and skeleton shutter, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. size of members of shutter as specified in SSR complete all as specified and as directed.
Supply and fix Stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples all complete as specified.
Material and labour for 2nd class hardwood in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
Supply and fix 100mm size extruded aluminum alloy handle fabricated type anodized (ISI Marked) complete all as specified and as directed.
Supply and fix 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Supply & fix 100 mm long MS Butt hinge , medium weight , cold rolled complete all as specified and as directed .
Material and Labour for applying two coats of Synthetic enamel paint over a coat of pink primer on new wooden surface exc 10 cm width or girth complete all as specified and as directed .
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface exc 10 cm width or girth complete all as specified and as directed .
Supply and fix Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and fix anodised aluminium frame for doors,windows,ventilators(including 2/3 track) with one or more rebated including jointing cleat for fixing etc.complete all as specified and as directed.
Supply and fix sliding aluminium anodized glazed shutter for sliding window with aluminium channel section weighning not less than 0.55 Kg per sqm including aluminium cleat,roller rubber neoprene packing/gusket etc complete all as specified and as directed. (Note: Glass shall be measured and paid separately)
Supply and fix sliding aluminium anodized wiremesh shutter for sliding window with aluminium channel section weighning not less than 0.55 Kg per sqm including aluminium cleat,roller rubber neoprene packing/gusket etc complete all as specified and as directed (Note: Wiremesh shall be measured and paid separately)
Supply and fix 4.0 mm thk sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane, complete as specified and as directed.
Material and labour for 75 mm thick plain cement concrete 1:3:6 type C1( using 40 mm graded stone aggregate ) as in flooring / plinth protection laid in alternative bays and joints shall be filled up with bituminous gola with 80/25 bitumen ( 1 part of bitumen to be mixed with 3 part of sand ) including finish the surface even and fair complete all as specified and as directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.surfaces, complete all as specified and directed.
Material and labour for concealed point wiring (concealed type) with FRLS PVC insulated 1100 volts grade unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm FRLS PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit medium grade of suitable size but not less than 20 mm and conduit accessories of adequate size with fittings and accessories as required at site including suitable size of pressed steel sunken terminal box made out of 1.2 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick insulated hylum sheet cover for fixing of switches switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth for One light point controlled by one switch complete all as specified and directed. complete all as specified as directed. Note :(i) Cost of cutting of wall, if any, for housing of GI box, ceiling rose, etc and also making good the disturbed surfaces are deemed to be included in unit rate. (ii) Cost of chase cutting if any for wiring shall be deemed to be included in the quoted rate)
All as per Item No 53 above but one ceiling fan/ exaust fan point controlled by one switch and one regulator complete all as specified and directed.
All as per Item No 53 above but one 3/5pin 6 Amp Socket outlet on the independent board complete all as specified and directed.
All as per Item No 53 above but one 3/5pin 6 Amp Socket outlet on the same board complete all as specified and directed.
Material and labour for concealed point wiring (concealed type) with FRLS PVC insulated 1100 volts grade unsheathed single core multi-stranded copper conductors 2.5 sqmm (nominal area) for phase, neutral and 2.5 sqmm FRLS PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit medium grade of suitable size but not less than 20 mm and conduit accessories of adequate size with fittings and accessories as required at site including suitable size of pressed steel sunken terminal box made out of 1.2 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick insulated hylum sheet cover for fixing of 16 A switches, sockets, etc and earth continuty conductor shall be connected to common earth complete all as specified as directed. Note :(i) Cost of cutting of wall, if any, for housing of GI box, ceiling rose, etc and also making good the disturbed surfaces are deemed to be included in unit rate. (ii) Cost of GI box of suitable size shall be deemed to be included in the qouted rate. (iii): Cost of chase cutting if any for wiring shall be deemed to be included in the quoted rate).
Supply and fix switch piano flush button 5 Amp single pole one way 240 volt complete all as specified and directed.
Supply and fix socket out let 3/5 pin 5 Amp 240 volt.complete all as specified and directed.
Supply and fix switch socket combination 3/5 pin 5 Amp 240 volt complete all as specified and directed.
Supply and fix switch socket combination 3/6 pin 15 Amp flush type 240 volt complete all as specified and directed.
Supply and fix celling fan regulator (step regulator) switch type AC 230 volt suitable for ceilling fan any sweep all as specified and directed.
Supply and fix celling rose surface,3 terminal of min da 63.5mm and ISI marked all as specified and directed.
Supply and fix box type luminiare, pre coated in white and pre-wired for single LED tube light 4 ft capacity suitable for single T8 LED tube rod 4ft 20 watt complete with LED tube rod T8, 22 W, 4ft long with extruded aluminium body, PC diffuser and inbuilt driver, holder, prewired fitted on two Nos 2nd class hard wood round block and connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of tube light fitting including taking down old unserviceable fitting any type complete all as specified and as directed. Make: Centrury LED Ltd / Wipro / Philips.
S & F LED building security light fitting 60W new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having seperate driver compartment with IP65 protection and impact resistance of IK07 including mounting bracket of suitable size complete all as specified and directed.
M & L for concealed sub main wiring complete with 2 runs of 2.5 sq mm,single core,PVC FRLS insulated,unsheathed cable,1100 volts grade,multi standard with copper conductor drawn through and including PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated 1.5 sq mm copper conductor for earth continuity conductor including taking down old US wiring all as specified and directed Note :- Two runs of cable one run of conduit and one run of copper wire shall be measured as one unit length.
Matetial and labour for sub-main wiring with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 4 sqmm and one run of 4 sqmm copper conductor as continuity earth wire drawn in and including PVC casing caping / PVC conduit medium duty of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directed (Note : (i) Three run of 4 sqmm cable one run of PVC conduit shall be measured and paid as one unit. (ii) Cost of wall cutting if any for laying of cable and also making good surfaces are deemed to be included in unit rate).
Supply and fixing TPN DB 4 way double door horizontal type suitable for four pole MCB TPN as incomer including make good of damaged surface/wall including re-connection with existing earth wire to DB incuding taking out the old unserviceable one complete all as specified and as directed.Note:- MCB shall be measured and paid separately.
Supply and fix powder coated sheet steel enclosure fitted with busbar, DIN channel, neutral link & earth link superline SPN DB (Double door) 8 way, including taking down the old unserviceable DB complete all as specified as directed.
Supply and fix MCB single pole & neutral 32 amps, 240 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed.
Supply and fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed.
Supply and fixing 415V 10KA 'B' curve miniaturecircuit breaker (MCB) of TPN/FP 40 to 100 Amp and current carrying capacity in the DB with all incoming / outgoing connections with proper size of lugs complete all as specified as directed.
Supplying, laying, commissioning and testing XLPE insulated PVC sheathed armoured heavy duty electric cable of size 16 Sqmm 4 core with aluminium conductor for working voltage upto and including 1100 volts, ISI marked to be laid on wall, fixed to pole, wall/roof complete with cable end, lugs including required size of aluminium thimble for making connection including taking down old unserviceable cable of any type and size completed all as specified and directed.
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron earth lead wire 4.0 mm dia length upto 7.5 mtr by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (light grade) not exc 7.5 mtr, alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 3 of SSR part-1 and testing on completion including taking out old earthing complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking out old wire complete all as specified and directed.
S&F GI pipe 15 mm bore 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking out old pipe complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to stores.
Hanging only ceiling fans (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan and n.exe 1.5 m in depth for taking out/laying of cable,foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtrs and depositing where directed including spreading, leveling at a level not exceeding 1.5 mtr from the starting point complete all as specified and as directed.
Supply and laying of DWC pipe of size 50/38 for cable protection complete with coupler etc. complete all as specified and directed by Engr in Charge. (Make Triputi,Gemini or as directed)
Supply and fix hanging rod suitable for hanging of ceiling fan incl. all necessary tools,accessories like clamps nut bolts etc required for fixing hanging rod on ceiling complete all as specified and directed.
CHATTERJEE ENTERPRISE
MAZUMDER AND CO
S Majumder and Construction
M/S MAHENDRALALL DUTTA
M/S KARTICK DUTTA
ChakrabortyTraders
S M ENTERPRISE
The Planters Engineering Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .