Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L3₹52.8 L+₹2.1 L (4.12%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L3 | Rejected-AOC L3 | |
| 3 | L3₹55.9 L+₹5.2 L (10.3%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
8 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh AP Singh, IDSE, SE
HQ CWE Chandimandir
CA NO CWE/CHD-54/2020-21 SPL REPAIRS TO OR MD ACCN BLOCK NO E-14/1 TO E-14/8, BLDG NO P-95 AT K AREA AND BLDG NO T-129 AT N AREA CHANDIGARH UNDER GE CHANDIGARH
2020_MES_376509_1
CWE/CHD-54/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class C, Cat a(i)
7 documents required · 7 mandatory
₹1,000
Yes
GE Chandigarh
₹1.2 L
Yes
10 Nov 2020
11 Sept 2020
10 Oct 2020
11 Sept 2020
8 Oct 2020
25 Sept 2020
60 days
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exc. 1.5 sqm each complete all as specified and directed.
All as item No 1 here-in-abvoe but area exc. 1.50sqm & not exc 4.00 sqm.
Taking down shutters of any description having area n exc. 1.00 sqm complete all as specified and directed.
S&F 125 x 60mm pressed steel frames for doors with one or more rebates incl necessary fixing lugs,hinges, lock, strike plate etc,complete all as specified and directed.
S&F 105x60mm pressed steel frames for doors with one or more rebates incl necessary fixing lugs,hinges lock, strike plate etc complete all as specified and directed.
M&L for PCC 1:3:6 Type C-1 (using 20mm graded stone aggregate) as in back filling to the chowkats and hold fast complete all as specified and directed.
Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracketframing (Beam, tee, angle, channel or flat sections) includingdistance pieces, cleats etc. Fe 410 -W (Gde- E- 250) complete all as specified and directed.
S&F 35mm thick 2nd class hard wood factory made plain framed panneled shutter (two panel) with pannels of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces as specified & directed. The size of rail and style as per IS 1003 (Part-1) Kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for 35mm thick 2nd class hardwood glazed and Skelton shutters, open rebated and prepared to receive glass,gauge etc.(with plain, chamfered or rounded, mitred and rebated sash bars,any numbers ÷d into squares ) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and directed.
M&L for 18/19 mm thick one side prelaminated Particle board,and other side balancing white lamination, exterior grade, and fixed with screws in cup board shutters/ shelves and kitchen cabinets all as specified and directed.
M&L for 1st class softwood beads, straight (any size) for edging of prelaminated Particle boards complete all as specified.
S&F factory made solid PVC single door frames of size 50 x 47mm made out of 5mm plain colour PVC Sheets reinforeced with MS Square tubbing in opening complete all as specified and directed.
Supply & fixing Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width struck side with solvent cement for slice and plane colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap inserted for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the style and rails with suitable PVC sheet beeding and joined together with solvent cement complete all as specified and directed.
S&F factory made box type Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded (ref Drg No TD-276(R) Sh 1/4 to 4/4 of CE CHZ) complete all as specified and directed.
As per item No 14 here-in-before but without glazing bars.
S&F 3mm thick sheet glass ordinary quality and fixed with oil putty or wooden beads having area not exc, 0.50sqm in each pane all as specified.
As per item No 16 here-in-before but frosted glass.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and directed.
S&F in repairs framed work for grills, gratings etc with ends of bar shouldered and for riveted or welded framed work guard bars and similar work complete all as specified and directed.
S&F 150 mm size MS door spring including roller and roller plate by means of welding or screwing down complete all as directed.
S&F 100 mm size SS butt hinges complete all as specified.
S & F Aluminium anodised hasp and staple 100 mm , safety type with MS hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F door stopper 100 mm of aluminium alloy body with rubber bottom complete all as specified and directed.
S&F aluminium handles, cast type, anodised of size 150 mm all as specified & directed.
S&F Aluminium anodised, barrel tower bolts of extruded section 200 long complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt 300mm long with hasp, stapple (bolt type) and fixing clips of sheet, cast or extruded sections complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new or previously untreated wooden surfaces exc 10cm girth or girth incl preparation of new wooden surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over previously untreated steel or iron surfaces exc 10cm girth or girth incl preparation of new steel surfaces complete all as specified and directed.
All as per item No 28 here-in-before but except primer.
Demolition of brick work built in cement mortar including all quoins arches pillars complete all as specified and directed.
M&L for brick work sub class “B” bricks straight or curveted in plan exc. 6mtr mean radius with old size bricks in CM 1:6 complete all as specified and directed.
As per item No 31 here-in-before but except bricks.
M&L for brickwork with subclass ‘B’ bricks old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 in walls complete all as specified and directed.
Demolition of reinforced cement concrete in any position at any height (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for Reinforced cement concrete 1:2:4, type B-1using 20mm graded crushed stone aggregate as in slabs supported on walls, beams, shelves and the like complete all as specified and directed.
M&L for chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1 part cement : 3 Part graded cleaned pre-packed reiver sand : 10% latex mortar by weight of cement : 0.5 w/c ratio) in 20mm to 30mm thickness including levelling profile etc complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of concrete flat surfaces complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia & over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and building with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for 18-20mm thick granite stone slab (jet black/ruby red or any other colour as directed) as in floors over & incl 15mm thick screed bed in CM 1:4, laid and jointed with grey cement slurry including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified
Taking down cement plaster including racking out joints hacking for key scrubbing down with water complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:6) on brick surfases finished the surface even & smooth complete all as specified and directed.
M&L for 15mm thick plastereing in CM (1:4) on brick surfases finished the surface fair & even complete all as specified and directed.
M&L for 10mm thick rendering in cement 1:3 on fair faces of concrete surface with finished surface even and smooth in ceiling complete all as specified.
Dismantling of floor hearth or wall tiles including cement mortar but not backing complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
M&L for coloured non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) , complete all as specified and directed.
All as per item No 46 here-in-before but in vertical surfaces such as skirting over and including 10 mm thick rendering in CM (1:3), complete all as specified and directed.
M&L for coloured non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) , complete all as specified and directed.
M&L for coloured ceramic glazed ceramic tiles in vertical surface 450X 300X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade/colour of tiles,over and including 10 mm thick rendering in CM (1:3), complete all as specified and directed .
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid,bedded and pointed in any mortar complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws/J hooks as complete all as specified and directed.
M&L for 18-20mm thick machine cut kota stone slab flooring over and including 15 mm thick cement screed base laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed .
All as per item No.52 here-in-before but in skirting /dado etc over 10 mm thick rendering in cement mortar (1:4) complete all as specified.
M&L for 18-20mm thick marble work (Makrana white , table rubbed and polished) for wall lining (veneering to wall) in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone over and including 15 mm thick cement screed base laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
Dismantling of AC/PVC pipes 110 mm fixed in any position complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm dia PVC (SWR) bends, in any redius complete all as specified and directed.
Dismantling of cast iron pipes 75/100 mm fixed in any position complete all as specified and directed.
S&F cast iron 100mm bore waste or vent (sand cast) pipes as in any length with or w/o ears with cement joints fixed to wall and laid in floor complete all as specified and directed.
All as per item No.59 here-in-above but except pipe 100mm.
S&F cast iron 75mm bore waste or vent (sand cast) pipe as in any length with or w/o ears with cement joints fixed to wall and laid in floor in complete all as specified and directed .
All as item No.61 here-in-above but except pipe 75mm.
S&F in repairs cast iron 100mm bore sand cast single branch pieces (equal or un equal ) ordinary quality and inverted spigot socket type or with parallel branch with oval access door complete all as specified and directed .
S&F in repairs cast iron 75mm bore sand cast single branch pieces (equal or un equal ) ordinary quality and inverted spigot socket type or with parallel branch with oval access door complete all as specified and directed .
S&F in repairs cast iron 100mm bore sand cast bends (any radius) and straight connecting piece complete all as specified and directed.
All as per item No. 65 here-in-abovebut 75mm bore.
S&F in repairs cast iron floor trap 75mm with CP grating including jointing to waste pipe, fixed in cement concrete 1:2:4 type B-1 complete all as specified and directed.
All as item No.67 here-in-above but 100mm dia .
S&F in repairs 100mm dia ‘P’ or ‘S’ trap complete all as specified and directed .
Taking up or down 15mm bore steel water tubing and connection including cleaning for refixing or removal to store all as specified.
S&F for GI tubing (medium grade) 15mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
All as item No.71 here-in-before but refixing.
Taking up or down 20mm bore steel water tubing and connection including cleaning for refixing or removal to store all as specified.
S&F for GI tubing (medium grade) 20mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
All as item No.74 here-in-before but refixing.
Supply and fixed in repairs vitreous china squatting pan Orissa pattern (white) of size 580x440mm including integral foot rest fixed in position complete all as specified.
S&F in repairs Vitreous China wash basin white flat back of size 550x400mm with CP waste coupling & PVC waste pipe complete all as specified and directed.
S&F in repairs 10 litres capacity PVC low level flushing cistern complete with all fittings complete all as specified and directed.
S&F in repairs 15mm dia bib tap, chromium plated brass, fancy type with crutch or butterfly handle, screwed down complete all as specified and directed.
S&F in repairs 15mm dia Pillar tap, chromium plated brass, fancy type with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repairs 15mm bore CP angle cock/Stop valves fancy type,screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixedcomplete all as specified and directed.
S&F in repairs brass chromium plated shower rose 125mm size with arm screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repairs chromium plated towel rail 60 cm long between the flanges 20mm dia with flanges complete all as specified and directed.
S&F in repairs CP grating doom 125mm dia with or without hole complete all as specified and directed.
S&F in repair stainless steel sink, 1.00mm thick for kitchen overall size 495mm x 420mm with bowl size 410mm x330mm x 160mm including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets, waste coupling, PVC waste pipe, washers, connecting union etc complete all as specified and directed.
S&F in replacement PVC connection 15mm size with PTMT Nuts of length 450mm complete all as specified and directed.
Dismantling of PVC water storage tanks capacity 500 Ltrs complete all as specified and directed.
S&F rotational moulded polyethylene (tripple Layer) water storage tanks 500 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I,complete all as specified and directed.
S&F 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
All as item No.91 here-in-before but but two coats on old wall surfaces.
M&L for applying two coats of oil bound distemper over 1-2mm thick wall care putty including a coat of alkali resistant priming paint incl preparation of new plastered surfaces of wall complete all as specified and directed.
All as per item No.93 here-in-before but on old surfaces of walls including complete removal of exixting treatment.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling surfaces complete all as specified.
M&L for preparation of old plastered surfaces and applying two coats of white wash on ceiling surfaces complete all as specified.
M&L for applying two coats of cement base paint on newly plastered surfaces of wall complete all as specified and directed.
M&L for applying two coats of cement base paint on old plastered surfaces of wall incuding preparation of surfaces by rubbing & washing down with water to remove dust etc, complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint on old surfaces of walls complete all as specified and directed. Make:- Asian Paints (Apex Ultima),Narolac (weather Shield) or equivalent approved make mentioned in Appx B.
Demolition of cement concrete as in ground floors and in paving exc 15cm thick above ground floors complete all as specified and directed.
S&F 50mm dia GI spout pipe 600 mm long in PCC 1:2:4 complete all as specified and directed.
M&L applying Injection groutingusing cementitious free flow grout 225 gms per 50 kg cement bag by fixing 12mm GI nozzles @ 450 mm c/c in diagonal patern with fast setting plugging compound plug and cutting the extra length of nozzle after grouting all in complete as per manufacture's specifications . Make :- Pidilite (Dr Fixit Pidicrete AM), Fosroc, Sikka or equivalent of approved make as mentioned in Appx 'B'.
M&L applying waterproof coating in two layers with brushes using approved chemical (Grey powder +White liquid) ,mix ratio 1:1.5(by volume) all as specified & directed. Make :- Pidilite (Dr Fixit Pidicrete AM), Fosroc, Sikka or equivalent of approved make as mentioned in Appx 'B'.
M&L applying 10 mm thick dubbing coat with cement plaster in cement mortar 1:2:2(cement :fine sand :coarse sand) admixing Dr Fixit pidiproof LW @ 200 ml per 50 kg cement bag all as specified & directed Make :- Pidilite or equivalent of any approved make as mentioned in Appx 'B'.
M&L providig protection layer applying 15 mm thick cement plaster in cement mortar 1:4 (cement :coarse sand) admixing Dr Fixit pidiproof LW @ 200 ml per 50 kg cement bag all as specified & directed directed. Make :- Pidilite or equivalent of any approved make as mentioned in Appx 'B'.
M&L providing cement concrete type B-0 1:2:4 using 12.5mm graded stone aggregate on roof kerbs grounded or chamfered admixing Dr Fixit pidiproof LW @ 200ml per 50 Kg cement bag all as specified. Make :- Pidilite or equivalent of any approved make as mentioned in Appx 'B'.
M&L for cement concrete 1:5:10 type E2 using 40 mm graded brick aggregate in sub base all as specified & directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and direcrted.
M&L plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate, as in coping, bed plates including necessary form work and weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Dismantling the entire roof covering including brick tiles, mud puska , mud plaster and water proofing treatment any number of layers or thickness etc of any description upto RCC roof slab and cleaning the surface including flashings and junction of parapets, etc with wire brushes and water to the entire satisfaction of Engineer-in-charge and applying a coat of cement slurry @ 3.00 kg/Sqm of cement complete all as specified and as directed.
M&L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate average thickness 50mm as in roof padding finished the surface even and smooth without using extra cement incl mixing water proofing compound (Dr. Fixit) as per manufacturers instruction (water proofing liquid shall be paid seperately) complete all as specified and as directed.
M&L for rendering 10mm thick in cm 1:3 mixed with liquid water proofing compound as per manufacturers instructions on concrete/brick surfaces finished even and smooth without using extra cement complete all as directed (WPC measured and paid separately) complete all as specified and as directed.
Supply only water proofing compound ISI marked complete all as specified. Make: Pidiproof WL (Dr Fixit) or equivalent ISI marked make as approved by GE.
Providing roof treatment as under : - (a) Applying bitumenous primer @ 0.30 litres per sqm over cleaned and dry roof surface including parapet. (b) M&L for applying a coat of blown bitumen 85/25 grade @ 1.20 kg per sqm over priming coat of roof. (c) M&L for providing and laying 3mm thick APP modified polyester reinforced water proofing membrane with minimum weight of 3.60 kg/sqm , as specified. The APP membrane shall be laid using torch-on application with minimum 10 cm side overlap and 15 cm end overlap. The APP memberane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet.
M&L for 20mm thick grey coloured PCC tiles 20cm x 20cm, machine pressed laid over & including 20mm thick screed or bedding layer in cement mortar 1:4 mixed with and including waterproofing compound (Pidiproof LW@20ml per 50 Kg bag) and joints grouted & pointed flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 as in roof kerb or mud stops mixed with acrylic base water proofing compound @ 1% by wt of cement including all necessary form work all as specified.
M&L for 75 mm thick PCC 1:3:6, type C-2 using 40 mm graded aggregate as in plinth protection incl filling the joints with mastic filling complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws/J hooks complete all as specified and directed.
S&F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed.
Rough excavation n. exc. 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base of floors/path etc. finished even & rough complete all as specified and as directed.
M&L for 60mm thick machine presssed precast concrete grade (M-35) interlocking paver blocks with grey cement and pigment confirming to IS-15658-2006 of any shape as directed, laid over and including 50mm thick sand cushion complete all as specified and as directed.
M&L Chequered cement concrete 20cmx 20 cmx 25 mm thick, set joint and pointed in neat cement slurry in floors laid over 15 MM thick CM 1:6 screed bed complete all as specified and directed.
Cutting holes in brick walls in Cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required exc half brick but n exc one brick complete all as specified and directed.
M&L for providing and fixing Gyp board panel laminated with texture vinyl coated paper tiles of size 595mmx595mmx9mm thick as in ceiling having snap grid 600mmx600mm including GI wall angle of size 24mmx24mmx0.43mm thick along with perimeter of ceiling, fixed to walls/ partition with the help of nylon sleeves at 450mm centre to centre, suspending intermediate Tee section of size 24mmx 38mmx0.35mm thick and cross Tee-section 24mmx25mmx0.3mm thick suspended from soffit of ceiling at up to 900 mm centre to centre or adjustable as required at site.4mmdia GI wire hangers fixed/tightened with ceiling with the help of nylon sleeve/rawl plugs including taking down old ceiling any type complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed FRLS/FRLSH 1100 volts grade single core muilty stranded copper conductor cables of size 1.5 sqmm for phase & neutral in and including concealed 20/25mm dia PVC medium duty conduits, sheet steel sunken boxes1.2mm thickness covered inculding with 3mm thick plastic laminated sheet for mounting switches, scockets, regulator etc and including 1.5 Sqmm copper conductor PVC insulated and unsheathed multi stranded green cable as earth wire for complete all as specified and directed. (unit rate quoted including cutting chases and making good the disturbed surface to match with the original. Nothing extra shall be paid on this account):-
All as per item No 126 here-in-before but one light point controlled by one switch/one fan point/one bell or buzzer controlled by one switch & fan regulator.
All as per item No 126 here-in-before but controlled by two switches.
All as per item No 126 here-in-before but one socket outlet three pin, 5 Amps on the same board.
All as per item No 126 here-in-before but one socket outlet three pin, 5 Amps, independent board.
M&L for point wiring using approved colour coding as per IS (For phase and neutral), with copper conductor 2.5 Sqmm (cross section area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, confirming to IS 694 drawn in and including PVC concealed medium duty conduit with fittings ISI marked, sheet steel sunken boxes incl 1.5 Sqmm (cross section area) single core, multistranded, FRLS, PVC insulated and un sheathed cable as earth continuity from the earth dolly to sunken boxes and light point 3 pin socket 15/16 Amps complete all as specified and directed.
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc. all as specified.
S&F switch piano flush type single pole one 230 volts one way, 5/6 Amps complete all as speciifed.
All as per item No 133 here-in-before but 2 ways.
S&F switch piano flush type single pole one 230 volts one way, 15/16 Amps complete all as speciifed.
S&F socket outlet three pin 5/6 Amp, 230 volts complete all as speciifed.
S&F socket outlet three pin 15/16 Amp, 230 volts complete all as speciifed.
S&F ceiling rose 3 phase /PVC/ polycarbonate insulated body complete all as specified.
S&F stepped type electronic fan regulator flush type complete all as specified and directed.
S&F bell push, flush type 6 Amps single phase one way complete all as specified and directed
M&L sub main wiring (with approved colour coding as per IS) with 2 single core 6 sqmm FRLS/FRLSH PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs) with and including 20/25mm dia concealed PVC conduits medium duty inclussives of Tee/bends/elbows/reducers and fixing accessories alongwith one run of single core 6 sqmm FRLS/FRLSH PVC insulated flexible stranded copper donductor 1.1 KV grade of earth for earthing as in repair complete all as specified and directed. Note : 2 runs of 6 sqmm cable and 1 run of 6 sqmm cable shall be measured as one unit.
S&F LED Batten box type made of CRCA sheet including 1 x 20 watt retro LED tube rods and pre-wired with high efficiency electronic driver and connecting with three core PVC copper flexible cable of size 23/.0076 from ceiling rose to connector block complete all as specified.
S&F batten holder bakelite complete all as specified (ISI Marked) complete all as specified and directed.
S&F LED lamp as per sample 12 watts complete all as specified.
Taking down and replacement of factory made sheet metal enclosure for distribution board double door type (Fixed to the wall), single pole and netural with 200 Amp rated bus bar, 8 way suitable for having MCB’s complete all as specified.
S&F MCB SPN of rating 240 volts, SPN 32-40 Amps incl taking down complete all as specified and directed.
S&F in repair MCB, SP, 240V, 5 to 32 Amps incl taking down complete all as specified and directed.
M&L bus bar chamber size 40cm x 25 cm x 20 cm with tin plated copper bus strips 4 Nos & Iron lead with locking arrangement capacity 200 Amps, 415 volts, 50 Hz, partially flushed to wall and including making good to disturbed portion and colour wash to match to surfaces complete all as specified and directed.
S&F in repairs MCCB 100 Amps, 415 volts, TPN, 16 KA with enclosure and including both connection with suitable size lugs and glands complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core in repairs complete all as specified and directed.
All as per item No 150 here-in-before but 16 sqmm 4 core.
Excavation in treches not exc 1.5m in width and 1.5m in depth and getting out excavated soft/loose soil complete all as specified and directed.
Returning, filling in including spreading levelling, watering, and well ramming in layers n. exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated materials n. exc 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
M&L for sand filling using approved clean dry sand for cushioning of undergound cables incl spreading levelling and well ramming in layers not exc 25 cm complete all as specified and directed.
M&L for sub class 'B' old size burnt bricks of class designation 100 ,for cable protection laid length wise perpendiculer to the axis of the cable complete all as specified.
Supply and lay GI tubing light grade in trenches for protection of cable for 50 mm dia complete all as specified and directed.
All as per item No 157 here-in-before but 40mm.
M&L for earthing complete with galvanized steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm bore connected to main earth wire on pole light grade 15mm bore connected to main earth wire on poleor control board or main switch and GI pipe medium grade 20mm bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:2:4 type B-1 20 mm graded stone aggregate excavation and earth work all as shown in electrical plate No 3 of MES Schedule part I of 2009 connected to earthing test point indicaed including testing on completion all specified & as directed.
S&F energy saving LED light fitting 40 to 45 watt luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium body with built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and sealed/compact driver for easy access during maintenance,suitable for operating on voltage 120 - 270 volt,AC,50 HZ,with max. driver of solid state covered , with seperately fiitted Surge protection of 5 KV , out put Luminous efficacy not less then100 Lumen/Watt , CRI more then 70, conforming to IP 66, class 1 complete all as per Manufacturer's specifications including GI 40mm light grade pipe bend to shape as bracket to mount on wall/ pole with suitable clamps nut bolts etc. complete all as directed.
S&F in repair LED Mirror light fitting complete made out of CRCA Sheet including 1x10watt LED rod complete connecting up with three core pvc copper flexible cable of size 23/.0076 from ceiling rose to connector comlete all as specifid and as directed. Make :- Philips Bajaj /Osram or equivalent of any make mentioned in Appx B.
Surface mounted LED bulk head luminaire 1x10 watt ,made of aluminium pressure die cast , white finish housing with PMMA diffuser , electronic driver and connecting with three core PVC copper flexible cable of size 23/.0076 from ceiling rose to connector block complete all as specified.
Square type surface mounted LED slim panel light fitting 1x12 watt with output lumens not less than 840 ,PF greater than 0.9 ,powder coated white finish housing with PMMA diffuser ,electronic driver and connecting with three core PVC copper flexible cable of size 23/0.0076 from ceiling rose to connector block complete all as specified. Note :- (i) For Sl item No 131, 147 to 150 MES SL No and year will be engraved on fitting / fixture by contractor with electric machine as complete all as specified. The contractor will also submit a report of all LED productes issued by NABL.
M&L bell electrical ding dong 5 Amps, 230 Volts complete all as specified and directed.
S&F LED tube light decorative box type fitting TRIMLINE type complete with LED tube 18/20 watt luminaire for 230 volt AC incl LED tube 18 watt with inbuilt surge protection device conforming to CAT No LDL-36-CDL of Crompton or equivalent make of Philips/C&S/Wipro/Halonix.
Street light bracket made out of 40mm dia, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30 x 6mm, with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable rusted GI bracket complete all as specified and as directed.
M&L for dismantling of ceiling fan scrapping old paint and applying two coat of synthetic anticorrosive enamel paint over a coat of anti-corrosive zinc red oxide with and including M&L for replacement of rubber bush, nut, bolts, washers and split pin complete and including replacement of down rod of 1.5 mtr long and 3 core copper flexible PVC insulated cable size 23/0.0076 from ceiling rose to fan motor complete all as specified and directed.
S&F ceiling fan single phase 230 volts 1200mm sweep with blades, canopy, down rod with and including (MS hanging hooks made out of FI 30x6mm, MS rod 10mm dia) MS tube heavy duty 1.5m long fan hanging rod duly painted with two coats of synthetic enamal paint over a coat of red oxide complete all as specified and directed.
Demolition of cement concrete as in ground floor and paving n. exc. 15cm thick below or above ground level incl removing material n. exc. 50m and depositing where directed.
M/s Matloob Ahmed
shree balaji builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .