Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-Finance | ₹30.6 L | L1 | Accepted-Finance L1 |
| 2 | L2₹32.9 L+₹2.4 L (7.71%)Accepted-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹32.9 L+₹2.4 L (7.71%) | L2 | Accepted-Finance L2 |
| 3 | L3₹34.5 L+₹4.0 L (12.9%)Accepted-Finance | ₹34.5 L+₹4.0 L (12.9%) | L3 | Accepted-Finance L3 |
| Sl No | Description | Qty | Unit | ARUNOTHAYA TRADERS L2 | SARAVANA TRADERS L3 | MATA GUJRI CONSTRUCTION CO. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. | 305.48 | CUM | 280 ₹85,534.4 Lowest | 350 ₹1,06,918 | 600 ₹1,83,288 |
| 2.00 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. | 207.51 | CUM | 50 ₹10,375.5 Lowest | 100 ₹20,751 | 120 ₹24,901.2 |
| 3.00 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 40.98 | CUM | 50 ₹2,049 Lowest | 100 ₹4,098 | 280 ₹11,474.4 |
| 4.00 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and as directed. | 7,740 | Each | 32.5 ₹2,51,550 Lowest | 36 ₹2,78,640 | 39 ₹3,01,860 |
| 5.00 | M&L for Plain Cement Concrete 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation complete all as specified and as directed. | 1.2 | CUM | 6,000 ₹7,200 | 7,500 ₹9,000 | 5,000 ₹6,000 Lowest |
| 6.00 | M&L for Plain Cement Concrete 1:3:6 type C1 (using 20mm graded stone aggregate) for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and as directed. | 1.5 | CUM | 6,000 ₹9,000 Lowest | 7,500 ₹11,250 | 7,000 ₹10,500 |
| 7.00 | Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and as directed. | 6 | RM | 500 ₹3,000 | 450 ₹2,700 | 380 ₹2,280 Lowest |
| 8.00 | M&L for boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure complete all as specified and as directed. | 12 | RM | 2,000 ₹24,000 | 2,200 ₹26,400 | 1,100 ₹13,200 Lowest |
| 9.00 | Boring of holes under road, pavement, hardstandinig by trenchless technology using ultrasound technique and necessary maching including HDPE pipe of 63mm dia suitable for 0.4 mpa working pressure. | 129 | RM | 1,000 ₹1,29,000 Lowest | 1,200 ₹1,54,800 | 1,400 ₹1,80,600 |
| 10.00 | S&F AC Distribution box with socket three phase, 63A , 5P, 415V including plug and socket, TPN 63 AMP complete all as specified and directed.
Make : C&S/ Havells/ABB/ Indoasian/ its equivalent approved by GE. | 6 | Each | 14,500 ₹87,000 | 1,500 ₹9,000 Lowest | 3,500 ₹21,000 |
Tender Value
₹34.8 L
EMD Value
₹69,580
Closing Date
20 Jul 2026, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
PROVN OF E/M SERVICES AND CERTAIN ASSOCIATED WORKS AT BUILDING NO P-289, STANDBY POWER SUPPLY FOR POL FOR DU AT LOGISTIC SECTION, POWER SUPPLY POINTS FOR SPORTS GROUND / FOOTBALL STADIUM PARADE GROUND,
2026_MES_772543_1
8528/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF)Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹69,580
Yes
8 Sept 2026
16 Jun 2026
27 Jul 2026
16 Jun 2026
20 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. | - | CUM | - | - |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. | 1 | CUM | - | - |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 1 | CUM | - | - |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and as directed. | - | Each | - | - |
| 5 | M&L for Plain Cement Concrete 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation complete all as specified and as directed. | 1 | CUM | - | - |
| 6 | M&L for Plain Cement Concrete 1:3:6 type C1 (using 20mm graded stone aggregate) for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and as directed. | - | CUM | - | - |
| 7 | Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and as directed. | - | RM | - | - |
| 8 | M&L for boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure complete all as specified and as directed. | - | RM | - | - |
| 9 | Boring of holes under road, pavement, hardstandinig by trenchless technology using ultrasound technique and necessary maching including HDPE pipe of 63mm dia suitable for 0.4 mpa working pressure. | - | RM | - | - |
| 10 | S&F AC Distribution box with socket three phase, 63A , 5P, 415V including plug and socket, TPN 63 AMP complete all as specified and directed.
Make : C&S/ Havells/ABB/ Indoasian/ its equivalent approved by GE. | - | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Binder1.pdf
Tender Documents • 0.83 MB
BOQ_865057.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .