Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹32.2 L+₹1.6 L (5.09%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹34.6 L+₹3.9 L (12.6%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.8 L+₹5.1 L (16.7%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹36.8 L+₹6.1 L (20.0%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Jun 2023, 6:00 pmClosed
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR/REPLACEMENT OF LT UG CABLE, JUNCTION BOX AND EXTERNAL ELECTRIFICATION AT AF STN THOISE UNDER GE (AF) THOISE
2023_MES_598779_1
GEAF/T-30/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GARRISON ENGINEER (AF) THOISE
As per Tender Document
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹80,000
Yes
22 Aug 2023
27 May 2023
19 Jun 2023
27 May 2023
17 Jun 2023
3 Jun 2023
Amount
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specified and as directed by Engineer-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and as directed by Engineer-in-Charge. Note:-Excavation and earth work to be measured and paid for separately.
Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness of 18cm shall be measured for payment purpose.
M&L for in repair / replacment XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and directed by Engineer-In-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 16.0 Sqmm, 4-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 25.0 Sqmm, 4-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 35.0 Sqmm, 4-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 50.0 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 70.0 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 95.0 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 120.0 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete all as specified and as directed by Engineer-in-Charge. Make : Denson/ M Seal/ Raychem
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting,63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-in-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen/ Havells
All as per BOQ Srl Item No 15.00 above but of size Capacity 40 Amps with Breaking Capacity 16 KA complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, outdoor, cubical type, Pedestal mounted, factory made, CPRI approved,, Al Bus Bar 400 Amps fabricated out of 3.4mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following complete all as specified and as directed by Engineer-in-Charge. Incoming:- (a) Change Over Switch 200 Amps -01 Nos (b) MCCB, four pole, 200 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA- 02 No ( incl 02Nos Amp meter). (c) MFn Meter V, A, F, kW, KVA, kVAr, kWh, , PF etc Make L&T , Equivelent in Seimns and Schinider -01 Nos (e) Suitable Contacter, relay,& circuit protection device Outgoing:- (i) MCB 4 pole 415 Volts TPN of capacity 63 amps thermal magnetic release adjustable type of breaking capacity 10 KA-06 No (incoming) With addition to Amp meter-06 (ii) MCCB 4 pole 415 Volts of capacity 40 amps thermal magnetic release adjustable type of breaking capacity 16 KA-02 Nos (outgoing) With addition to Amp meter-02
Supply, installing, testing and commissioning, factory made & tested, CPRI approved, LT Feeder pillar box outdoor type of size 2.0 m x 1.5m x 0.9 m suitable for 415Volts 3phase 4wire 50Hz AC supply having bus bar chamber with insulated copper bus bar 900amp rating installed on pocelain insulators, The panel shall be dust and vermin proof, IP65 protection & made out of MS CRCA quality sheet 3.15mm thick, and 50mm x 50mm x 6mm angle iron base frame with 04 Nos legs 75cm long made out of MS angle iron of size 50mm x 50mm x 6mm, legs embedded in PCC (1:2:4) having bottom of the panel at height of 45cm above ground level, duly powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside (after anticorrosive treatment (7tank) front opening type with aprons for cable entry with double door shutter and locking arragements, internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked of adequate size, the scope of work comprising the following including taking down old unserviceable feeder pillar box complete all as specified and as directed by Engineer-in-Charge. (a) ON LOAD Change over switch front operated of capacity 630 Amps TPN :- 02 Nos. (b) Copper Bas bar mounted on synthetic bas bar insulation of 900 Amps Capacity. (c) MCCB 4 pole,630 Amps, 415 Volt, 50 KA AC with thermal setting 70% to 100% and rupturing capacity not less than 35 KA = 02 Nos (I/C). (d) MCCB 4 pole,400 Amps, 415 Volt, 50 KA AC with thermal setting 70% to 100% and rupturing capacity not less than 35 KA = 01 Nos (O/G)
M&L for Cable Junction Boxes IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry ) of Size 300 x 600 x 170 in mm with cable entery range of 150-240 sq.mm incl 5 (Five) Nos /bus bar Make Hensel Cat Pat No K 2405 (5 terminals) or Equivalent volume in size or technical specification complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs bollard light fitting square suitable for Led light complete grouted on PCC base 30x30x30 cm complete all as specified and as directed by Engineer-in-Charge. Note: The job includes the cost of all necessary Civil works as specified and directed by Engr in Charge
S&F in repairs bollard light fitting Round suitable for Led light complete grouted on pcc base 30x30x30 cm complete all as specified and as directed by Engineer-in-Charge. Note: The job includes the cost of all necessary Civil works as specified and directed by Engr in Charge
S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 139 x 119 x 70 mm (internal dimensions) comprising 2 Nos aluminium busbar of adequate capacity including suitable size MS clamps, including taking down old unserviceable junction box complete complete all as specified and as directed by Engineer-in-Charge.
Attending day to day complaints for maintenance and repair of LT Network of any type and any specifications or any accessories related to Electric Supply of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of light fittings shall be measured and paid separately.
Note: The work under subject BoQ (item No. 1 to 23 ) is meant for maint of External Electric Supply in AF Stn Thoise under GE(AF ) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply in the AF station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
Ms Salaria Builders
M/S A K ENGINEERS & CO.
EESSI
FANGALIA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .