Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC MOHALA GOS GANJ SIKANDRARAO HATHRAS | SIKANDRARAO | HATHRAS | UTTAR PRADESH | ₹10.7 L | L1 | Accepted-AOC l1 |
| 2 | L2₹11.9 LAccepted-AOC LAXMI NAGAR NIKAT JAIY MATESWARI SCHOOL HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | ₹11.9 L | L2 | Accepted-AOC l2 |
| 3 | Rejected-Technical 07 158 SAKET COLONY HATHRAS | - | - | Rejected-Technical Clause 3.1 (a) (i) of ITB |
| 4 | Rejected-Technical | - | - | Rejected-Technical Clause 3.1 (a) (i) of ITB |
Tender Value
₹14.0 L
EMD Value
₹28,100
Closing Date
12 Mar 2026, 12:00 pmClosed
EE RED HATHRAS
HATHARAS
CONSTRUCTION AND MAINTINANCE OF VRC BUILDING IN SHIKANDRA RAO
2026_REDUP_1119086_1
554/RED/2025-26/DT. 30.01.2026
Open Tender
Civil Works
90 days
Hathras
Please refer Tender documents.
3 documents required · 3 mandatory
₹766
₹28,100
Yes
6 May 2026
21 Feb 2026
12 Mar 2026
21 Feb 2026
12 Mar 2026
21 Feb 2026
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per SI.No. 2.8.1
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per SI no. 4.1.8
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as SI No-5.1.2
Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) as per SI No- 6.1.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Under Floor) as per SI.No. 2.25 (a)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. as per SI no 2.27
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto Plinth Lvl as SI No-5.1.2
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to SI:2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) as per SI No- 6.3.1
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Above Plinth Lvl as SI No-5.2.2
FORM WORK 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
FORM WORK 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.3 Suspended floors, roofs, landings, balconies and access platform
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per SI No. 5.3
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22 B.1
12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Outer Side as per IS 13.4.2
15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) as per IS 13.5.2
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. As SI No. 11.3.1
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 4 mm thick. As SI No- 11.13.1
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per Sl no. -13.46.1 Two Coats
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per Sl no. -13.41.1 Two Coats
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per Sl no. -13.62.1
Cement Concrete topping 1:2 Cement and aggregate og size 4.75 mm and below by volume laid over and finished monolithic with structer slab. As per SI No. 14.66
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. As per SI- 12.41.2
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm widex 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts include all complete work as per D.S.R 12.52
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. Sqm
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. sqm 156.05
13.81 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats) sqm 62.70
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 11.26.1 25 mm thick
PVC WALL panneling inlcude all complete work
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg
10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. 10.29.1 Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides sqm 844.70
13.99 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.99.1 One or more coats on old work sqm 102.80
Front bord of Meeting Hall as per Market rate
S/F of Innaugration cum informatry stone i/c all lettering writing complete .
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic laminated backalite sheet etc complete in all respect as directed including matching colour wash. SI No. 138 C
Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. SI No. 140 C
Add for light / fan points with modular type switch in place of piano type switch. SI No. 187 A
Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. and piano type switch and socket etc., complete in all respect including matching colour wash. SI No. 141 C
Add for plug point with modular switch & socket in place of piano type switch & socket. SI No. 187 C
Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. SI No. 1139 A
S/F of Computer point with 2 no. 5Amp. 5 pin plug with switch and socket on concealed M.S. box including supply of all material, labour T&P etc, required for proper completion of work for Computer. SI No. 2 *(141 C+187 C)
Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. SI No. 1203 C
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. SI No. 1413A Cat A
Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit etc, complete in all respects including matching colour wash. SI No. 1307 C
Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one no. 2.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. including matching colour wash etc. complete in all respect. SI No. 221 C
S & F surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge. S.I. No. 1025 A Cat B
S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve SI No. 1002 Cat A
S&F of 32 Amp. DP MCB (10 KA) C Curve SI No. 1009 Cat A
Supply and fixing hexagonal/RoundG.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm& brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. SI No. 1149
Supply and fixing of recess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. SI No. 1401 Cat A
Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire SI No. 189
LED Bulb 9w (EESL)
Supply of BEE 5 Star rated-1200mm sweep ceiling fans with fan motor of A.C permanent insulation,capacitor rating confirming BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltge 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. SI No. 1501 (i)
Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect. SI No. 1116
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
T1TashilVRC.pdf
Tender Documents • 0.80 MB
TashilSikandraoVRCnit.pdf
Tender Documents • 0.67 MB
BOQ_2080484.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid