Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹45.3 LAccepted-AOC 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹46.4 L+₹62,228.45 (1.36%)Rejected-Finance SHIVSHAI PUNARVASAN PRAKALP BLDG NO 10 ROOM NO 115 MAHARASHTRA NAGAR MANKHURD E MUMBAI 400088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L-2 | Rejected-Finance Being higher bid value | |
| 3 | L-3₹47.0 L+₹1.2 L (2.59%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L-3 | Rejected-Finance Being higher bid value | |
| 4 | L-4₹51.9 L+₹6.1 L (13.3%)Rejected-Finance 6 NALAPUKUR LANE FLAT 2C SENHATI COLONY KOLKATA 700034 WEST BENGAL | KOLKATA | WEST BENGAL | 700034 | L-4 | Rejected-Finance Being higher bid value | |
| 5 | L-5₹52.2 L+₹6.4 L (14.0%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L-5 | Rejected-Finance Being higher bid value |
Tender Value
₹47.5 L
EMD Value
₹95,080
Closing Date
24 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alipore Kolkata
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
SPL REPAIR TO SECURITY WALL AND SECURITY LIGHT OF HQ BSA COMPLEX UNDER GE (A) KOLKATA
2023_MES_635123_1
GE/ALP(8295B) KOLKATA OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Alipore Kolkata
CLASS D Category a (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer Alipore
₹95,080
Yes
GE Alipore Kolkata
29 Feb 2024
30 Dec 2023
31 Jan 2024
30 Dec 2023
24 Jan 2024
17 Jan 2024
30 Dec 2023 - 6 Jan 2024
8 Jan 2024
Amount
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortar (1:4) on other than fair face of brick work or concrete surfaces and finished and surface even and smooth including necessary scafolding etc complete all as specified and as directed.
Demolition of stone slab or tiles of any description or thickness in floors or aprons etc (laid bedded and pointed in any mortar) complete all as specified and as directed.
S & F for dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size not exceeding 0.25 sqm fixed with and including, making V groove at top the bottom of stone and drilling hole for hold fastener, polishing, rubbing and including silicon treatment, including 10mm rendering of cement mortar (1:3) complete all as specified and directed.
M & L for 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including 15 mm thick cement mortar bedding (1:6) including to match with shade of granite including dismantling complete all as specified and as directed. (upto 12 stories buildings)
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) and removing debris and rubbish off the premises.
M & L for 10 mm thick granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick rendering cement mortar (1:3) to receive the tile also grinding and polishing complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quions, arches, pillers etc complete all as specified and directed.
M & L for brick work with sub class 'B' brick straight of curved on plan exc 6 m mean readius built in cement mortar (1:6) complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for cement concrete 1:2:4,type B-0 (using 12.5 mm gradded stone aggregate) providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M & L for 75 mm thick PCC (1:3:6), type C2, (using 40 mm gradded stone aggregate) as in plinth protection/ paving, surface finished even & smooth without using extra cement complete all as specified and as directed.
M & L for ornamental type Framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron door; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for preparation of new steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer complete all as specified and as directed.
M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint on steel surface complete all as specified and as directed.
M & L for preparation of old plastered surfaces of wall and applying one coats of cement based paint complete all as specified and as directed.
M & L for preparation on new plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
M & L for preparation of old plastered surfaces of wall and applying one coats of anit-algae and anti-fungal exterior grade weather coat paint complete all as specified and as directed
M & L for preparation on new plastered surfaces of wall and applying two coats of anit-algae and anti-fungal exterior grade weather coat paint oer a coat of primer complete all as specified and as directed.
Supply & fixing in repair stainless steel concerntina coil fencing with punched tape concerntina coil 600mm dia 10 mtr openable length (total length 90mtr), having 50 nos round per 6 mtr length with 9 horrizsontal RBT reinforced barbed wire, stud tied with GI satples and GI clips to retain horrizontal, including nessesary bolts or GI barbed wire tied with angle iron complete all as specified and directed.
Dismantling wrought iron or mild steel work (as iron spike embadded in PCC copping) of any description not otherwise provided for complete all as specified and directed.
Disconnecting and taking out old cable from trench/wall and Supply and laying/fixed on wall with GI Clamp (rates quoted shall be inclusive of fixing GI clamp cost) under ground heavy duty XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 10 sq. mm 4 core complete all as specified and directed.
All as per item no 23 above here in -before but of size 16 sq. mm 4 core complete all as specified and directed..
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for laying of cable , fixing of pole etc and getting out in soft/loose soil, old serviceable bricks etc complete all as specified and directed.
Materials and labour for sand filling 23 cm thick above the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness of 18 cm complete all as specified and directed.
Supply and laying for burnt brick sub class 'B' of size 23 X 12.5 X 7.5 cm locally available best quality laid in trenches for protections of under ground cable complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and directed
Supply and fixing for 20-25 watt LED post top lantrerns fittings made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern after and including dismentling of existing unserviceable fittings complete all as specified and directed. Make : Crompton (Cat pat No -CBP-610-25-57-SL-CA-NBK)/ Havells (Cat No- NRUBYPT25WLED830SSYMTOPC)/Bajaj( Cat No-P20W LED WH)
S & F for M.S. Fabrication work consisting of wire mesh, M.S. Angle Flat etc duly cut into shape and size to fabricate cage for Post top lanterns mounted on boundary wall complete as specified and as directed including grouting on wall, one coat of red oxide meteal primar and two coats of synthetic enamel paint.
S&F for thermoplastic street light junction box, weather proof having ingress protection level IP-66 and size L (254-255mm)x B (180-205mm)x H(111-112mm) duly fixed flush in existing wall (including 1 no 5 way cable connector 3 nos polymide cable gland having sealing range 17-25 mm complete including necesssary connection to incoming/outgoing cable complete all as directed. Make- Hensel Cat No- 2525G)/ Cape(Cat No- CIB009PS)/Eqv of Electro or equivalent make as specified by GE.
S&F for Post on boundary wall for post top lantern made of 40/50 mm dia light grade GI pipe including fixing to boundary wall by grouting and painting with two coats of black synthetic enamel paint over a coat of red oxide metal primer complete for maximum length of 0.6 mtr all as specified and directed.
M & L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth.
S&F for rigid non-metallic 20 mm PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
Material and labour for PVC insulated FR PVC nsulated 1.0 Sqmm 3 core multi stranded copper conductor cable alongwith connected to common earth doully drawn through concealed PVC conduit complete all as specified and directed.
Design, supply, erection, testing and commissioning of indoor type LT Street Light Controller Panel of overall size not less than 500mm width x 1100mm Height x 300mm Depth, duly mounted on a M.S.Angle (40mmx40mmx5mm) frame having 400mm long M.S. Angle (40mmx40mmx5mm) leg , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to incoming / outgoing side of Incomer MCCB for termination of cables / busbars and FRP / DMC Cable connectors for termination of outgoing cables from MCBs.The Panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of panel boards and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-42 and general construction conforming to IS : 13947. The Panel Board shall be made out of 2.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front and rear opening facility The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. Suitable rubber gromet shall have to be provided in all the inter compatmet holes for safety of wiring. The panel shall be comprising of the followings :-
(a) Incomer MCCB 4 Pole, 40 Amps,16 KA (adjustable thermal 100% - 80% - 01 No. (Make : LEGRAND / L&T / BCH / ABB). (b) Outgoing MCB TPN, 20 Amps,10 KA - 04 No. (Make : LEGRAND / L&T / BCH / ABB). (c) LED indicator lamp, 22mm (Red-Yellow-Blue) - 02 Set (L&T / RAAS / TEKNIK / ESSEN). (d) Control MCB (10 KA) of rating SP 6 amps -3 Nos. (e) Aluminium Danger Notice Plate (150mm x 100mm) duly revetted on front wall of Bus Bar Chamber. (f) 3 Pole Power Contactor 40 Amps having coil of 220-230 volt rating - 1 No (BCH / L&T / SIEMENS). (g) Astronomical Time Switch 2 channel, having 1 NO & 1 NC contact and compatible to 110 - 240 volts AC(50-60 Hz) (L&T / HAVELLS / LEGRAND).
Power & Control Wiring : (i) All Power Wiring for outgoing MCBs shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 4.0 sqmm. (ii) All Control Wiring for LED Indicators shall be carried out by Gray coloured 1100 volt grade single core multiflexible type copper wire of nominal cross sectional area 1.0 sqmm. Note : Drawing of panel board shall have to be got approved from Engineer-in-Charge before placing of order for fabrication work.
AZIM ENTERPRISES
dutta and dutta
SOMANI BUILDERS
MAZUMDER ENTERPRISE
RAJ ENTERPRISE
KWALITY CONSTRUCTION
UNITED ENGINEERS
PRABIR TRADERS
MS AP CONSTRUTION AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .