Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC SUCCESSFUL BIDDER | |
| 2 | L2₹9.9 L+₹33,139 (3.45%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER | |
| 3 | L3₹10.0 L+₹36,068 (3.75%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING L3 BIDDER | |
| 4 | L4₹10.0 L+₹37,563 (3.91%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING L4 BIDDER | |
| 5 | L5₹10.1 L+₹44,903 (4.67%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | M/S NIYATI NETWORK L1 | M/S Ajoy Acharjee L3 | SHRI RAJESH DEY L6 | M/S SANKAR GOPE L5 | M/S PAUL ENTERPRISE L4 | SHRI CHANDAN CHANDA L2 | SUMAN DEB L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI lead wire 4.0mm dia by means of nuts, bolts, check nuts and washers , earthing lead to be protected by galvanised iron pipe of 20mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.
Notes:-
(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item.
(ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. | 20 | Each set | 8,820 ₹1,76,400 Lowest | 9,100 ₹1,82,000 | 9,500 ₹1,90,000 | 9,500 ₹1,90,000 | 9,050 ₹1,81,000 | 9,560 ₹1,91,200 | 9,601 ₹1,92,020 |
| 2.00 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI strip of size 25x4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.
Notes:-
(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item.
(ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. | 18 | Each set | 9,449 ₹1,70,082 Lowest | 9,650 ₹1,73,700 | 9,750 ₹1,75,500 | 10,000 ₹1,80,000 | 9,750 ₹1,75,500 | 9,700 ₹1,74,600 | 9,790 ₹1,76,220 |
| 3.00 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI strip of size 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.
Notes:-
(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item.
(ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. | 20 | Each set | 9,980 ₹1,99,600 Lowest | 11,000 ₹2,20,000 | 10,800 ₹2,16,000 | 11,000 ₹2,20,000 | 11,000 ₹2,20,000 | 10,560 ₹2,11,200 | 10,825 ₹2,16,500 |
| 4.00 | Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with copper strip of size 20x3mm by means of nuts, bolts, check nuts and washers made of copper or copper earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.
Notes:-
(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item.
(ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. | 15 | Each set | 20,850 ₹3,12,750 Lowest | 21,000 ₹3,15,000 | 21,200 ₹3,18,000 | 20,850 ₹3,12,750 Lowest | 20,850 ₹3,12,750 Lowest | 20,865 ₹3,12,975 | 21,216 ₹3,18,240 |
| 5.00 | Material and labour in repairs for Earth continuity conductor or main earthing lead of 4mm dia galvanised iron or steel wire fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed. | 20 | RM | 69 ₹1,380 | 70 ₹1,400 | 65 ₹1,300 Lowest | 69 ₹1,380 | 69 ₹1,380 | 85 ₹1,700 | 69 ₹1,380 |
| 6.00 | Material and labour in repairs for Earth continuity conductor or main earthing strip of 25x4mm galvanised iron fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed. | 30 | RM | 240 ₹7,200 Lowest | 250 ₹7,500 | 250 ₹7,500 | 240 ₹7,200 Lowest | 240 ₹7,200 Lowest | 242 ₹7,260 | 258 ₹7,740 |
| 7.00 | Material and labour in repairs for Earth continuity conductor or main earthing strip of 32x6mm galvanised iron fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed. | 22 | RM | 310 ₹6,820 Lowest | 310 ₹6,820 Lowest | 325 ₹7,150 | 310 ₹6,820 Lowest | 310 ₹6,820 Lowest | 314 ₹6,908 | 333 ₹7,326 |
| 8.00 | Material and labour in repairs for Earth continuity conductor or main earthing strip of 20x3mm copper fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed. | 35 | RM | 555 ₹19,425 Lowest | 600 ₹21,000 | 565 ₹19,775 | 555 ₹19,425 Lowest | 560 ₹19,600 | 558 ₹19,530 | 569 ₹19,915 |
| 9.00 | Repair and Replacement of air termination single pointed copper rod 12mm dia and 300mm long fixed on copper strip all as specified and directed. | 15 | Each | 585 ₹8,775 | 590 ₹8,850 | 575 ₹8,625 Lowest | 585 ₹8,775 | 585 ₹8,775 | 587 ₹8,805 | 588 ₹8,820 |
| 10.00 | Repair and Replacement of air termination single pointed Aluminium rod 12mm dia and 300mm long fixed on copper strip all as specified and directed. | 9 | Each | 360 ₹3,240 | 365 ₹3,285 | 350 ₹3,150 Lowest | 360 ₹3,240 | 360 ₹3,240 | 362 ₹3,258 | 355 ₹3,195 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
6 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Agartala
AGE (I) AGARTALA PIN-901184 C/O 99 APO
REPAIR/ REPLACEMENT OF EARTH CHAMBER, EARTH TESTING POINT, LIGHTING PROTECTION, MEASUREMENT OF EARTH TEST RESULTS AT VARIOUS LOCATION AT MIL STN AGARTALA
2025_MES_707584_1
8683/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
AGARTALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Agartala
₹19,000
Yes
22 Aug 2025
9 May 2025
9 Jun 2025
9 May 2025
6 Jun 2025
23 May 2025
Amount
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI lead wire 4.0mm dia by means of nuts, bolts, check nuts and washers , earthing lead to be protected by galvanised iron pipe of 20mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI strip of size 25x4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI strip of size 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with copper strip of size 20x3mm by means of nuts, bolts, check nuts and washers made of copper or copper earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Material and labour in repairs for Earth continuity conductor or main earthing lead of 4mm dia galvanised iron or steel wire fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed.
Material and labour in repairs for Earth continuity conductor or main earthing strip of 25x4mm galvanised iron fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed.
Material and labour in repairs for Earth continuity conductor or main earthing strip of 32x6mm galvanised iron fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed.
Material and labour in repairs for Earth continuity conductor or main earthing strip of 20x3mm copper fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed.
Repair and Replacement of air termination single pointed copper rod 12mm dia and 300mm long fixed on copper strip all as specified and directed.
Repair and Replacement of air termination single pointed Aluminium rod 12mm dia and 300mm long fixed on copper strip all as specified and directed.
Material and labour in repairs for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors all as specified and directed.
Repair and Replacement of test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 Nos 8mm dia to 25mm long hex head screw all as specified and directed.
Taking out earth chamber cover, cleaning inside earth pit including copper salt & salt mixed with water pouring to earth pits and removing the old rusted nuts and bolts and refixing with new nuts and bolts, Testing of earth value complete all as specified and directed
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details.
SHRI CHANDAN CHANDA (BID ID -3315351)
M/S Ajoy Acharjee (BID ID -3314913)
M/S PAUL ENTERPRISE (BID ID -3315069)
M/S SANKAR GOPE (BID ID -3314995)
SHRI RAJESH DEY (BID ID -3314953)
SUMAN DEB (BID ID -3315325)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .