Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹40.7 L+₹3,459.97 (0.09%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹41.7 L+₹1.0 L (2.49%)Rejected-AOC GURHA BRAHMANA TEH AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹41.9 L+₹1.2 L (2.95%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹42.6 L+₹1.9 L (4.71%)Rejected-AOC | L5 | Rejected-AOC Other than L1 |
Tender Value
₹48.4 L
EMD Value
₹97,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Garrison Engineer(North) Akhnoor
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
SPL REPAIR TO BLDG NO P-04 OFFRS ACCN AT RLT VIHAR, T-19 (COOK HOUSE), T-18 (DINING HALL) AND T-27 (RATION STORE) OF 768 (I) TK TPTR PL ASC UNDER GE (NORTH) AKHNOOR
2024_MES_665128_1
CA NO- GE(N)/AKH-26/2024-2025
Open Tender
Job Works
Item Rate
180 days
Akhnoor
Class D Cat a i
8 documents required · 8 mandatory
₹500
GE (North) Akhnoor
₹97,000
Yes
19 Feb 2025
10 Jul 2024
19 Sept 2024
10 Jul 2024
12 Sept 2024
31 Jul 2024
Amount
Taking down old unsv roof treatment including PCC padding if any, plastering, removing existing bitumen felt treatment including brushing, cleaning top surface of roof slab, brooming etc including disposing off debris from MoD land, complete all as specified and directed.
Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound on fair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra lime or cement ) all as specified and directed.( Water proof compound rate is not paid seperatly.)
Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) 1st Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer. (b) 2nd Course : Applying evenly a tack coat of industrial bitumen grade 85/25 conforming to IS-702 at rate of 1.2 Kg/Sqm. (c) 3rd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints. (d) 4th Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as specified and approved including demolition and filling of sunken floor with & including laying of PCC 1:5:10 type E-2 (using 40mm brick aggregate). (a) First layer of slurry of cement @0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours. (b) Second layer of slurry of cement @0.242 kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/Sqm. This layer allowed to air cure for 4 Hours. (c) 15mm thick plaster in CM 1:3 mixed with WP compound to be provided while concrete is still green. (d) Joint of/Trap/WC/Soil pipes shall be properly sealed with sealing compound. Contd to Srl item No 4.01....
Note:(a) Concrete for sunken slabs shall be mixed with WP compounds as per manufacturer's instructions. Before carrying out water proofing treatment the sunken slab shall be tested with water for 48 hours for any leakage /dampness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested before passing for next stage. (The rate quoted includes water proofing compound as per manufacturers instructions). (b) Please note that only floor area shall be measured for payment purpose.
Preparation of new or previously untreated surface of concrete, asbestos cement APP membrane or surface of any description and applying two coats of aluminium paint over roof surfaces over 10cm girth or width, not otherwise described, all as specified and directed.
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified.
Taking down cement plaster from brick or stone walls/ceiling incl racking out joints hacking for key, scrubbing down with water etc all as specified and directed.
Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified.
Rendering 10 mm thick cement plaster with cement mortar(1:6) on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified
Applying 3mm thick wall care putty over newly plastered / old plastered surfaces of wall, complete all as specified and directed.
Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and directed.
Complete removal of exising treatment of old wall surfaces complete all as specified.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
Preparation of Old plastered and unplastered surfaces of walls and applying two coats of oil bound distemper including filling small depressions by putty , washing, rubbing, stopping brooming down with steel wire brushing all as specified and directed.
Preparation of old painted surfaces with complete removal of existing treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall complete all as specified and directed.
Preparation of newly plastered surfaces & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed. Note for item No-16 & 17:- (i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/ (ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
Preparation of Old plastered and unplastered surfaces of ceilings and applying two coats of oil bound distemper including filling small depressions by putty , washing, rubbing, stopping brooming down with steel wire brushing all as specified and directed.
Preparation of newly plastered surfaces of ceilings and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:3 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqm in width or girth and applying two coats of apex as reqd over one coat of primer including formwork/scaffolding work upto height 7.0mtr above ground level of bldg complete all as specified.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described complete all as directed.
Reinforced cement concrete nominal mix Type B-1 1:2:4 (20mm graded crushed stone aggregates) for cooking platform ,Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified.
Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed.
Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like including pointing in white cement (1:2) using marble dust with admixure of pigment to match with shade of granite including 15mm thick screed of CM 1:4 after applying cement slurry@3 kg/sqm of cement per sqm, complete all as specified. (Note : A hole shall be drilled in the Granite after fixing for gas pipe and Moulding of edges of slab shall be included in quoted rates all as directed by Engr-in-Charge).
Vitrified ceramic tiles (Light shade) 10mm thick (square /rectangular) polished, area of each tile n.exceeding 0.36 sqm laid as in floors/skirting, set and jointed in neat cement slurry and pointed in white/coloured cement to match with shade of tiles including 15mm thick screed bed/base in cement and sand mortar 1:4, complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed/base in cement and sand mortar 1:4, complete all as specified and directed.
Glazed ceramic tile 600x300mm/ 450x300mm/ 450X650mm x 7 to 8mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick bedding layer in cement and sand mortar 1:4 complete all as specified and as directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each, complete all as specified and directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) n.exc 1.50 sqm complete all as specified and directed.
Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
Pressed steel frames for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock strike plates complete including providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed.
PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in filling of pressed steel frame and parapet coping lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
PCC 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed.
Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Powder coated aluminium anodised door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
Powder coated anodised aluminium window / ventilator( glazed / gauged skeleton shutter ), (minimum thickness of powder coating 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No. ) suitable handle (1 No.) complete all as specified and as directed.
Factory made 35 mm thick ,Flush shutters, solid core construction, with block board core and plywood face panels, one face is commercial on both side etc complete all as specified & as directed.
30mm thick 2nd class hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete.
100 mm butt hinges, medium weight cold rolled mild steel, complete all as specified.
Aluminium handles cast type anodised of size 150mm with screws long ISI marked complete all as specified.
Aluminium anodised barrel tower bolt 150 mm, extruded section ISI marked complete all as specified.
S& F Hasp and staple safety type of aluminium anodised 100 mm long as a cupboard locker.
75 mm butt hinges, medium weight cold rolled mild steel, complete all as specified.
Aluminium anodised sliding door bolts with hasp and stapple extruded section or cast aluminium alloy with length of bolt as 300 mm including fixing bolts complete all as specified.
Steel windows/ventilator (Box type) factory made with double shutter with or without devetailed bar ( gauzed & glazed shutter) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 . Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid seperately under respective item.
Description all as per Item No 50 above, but only glass pane shutter without glazing bars.
Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified.
Sheet glass ordinary quality, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and as directed.
Figured glass pin headed type, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified.
Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
Pre laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 19 mm thick in repairs, complete all as specified and directed.
Pre laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 12 mm thick. (Kitchen cup board/covered bottom shelf of cooking platform) fixed in repairs complete all as specified and directed.
External teak wood lipping 6 mm thick fixed with nails for 18/19 mm thick board, complete all as specified.
Curtain rail, 20mm dia Stainless steel fixed with and including two Nos of bracket & side cup including taking down of old curtains rods, complete all as specified.
Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed.
Preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of new untreated wood and wood based surfaces of any description over 10cm in width or girth not otherwise described and painting with two coats of synthetic enamel paint over a coat of pink premier, complete all as specified.
Demolition of cement concrete in ground floors (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
25mm thick PCC 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate) as in floor finished even and fair to receive tiles, kota stone complete all as specified and directed.
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) 3 layer hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed.
Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed.
Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc., complete all as specified and as directed.
Mild steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Mild steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
15mm bore gate valve (Gun metal) cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified.
20mm bore gate valve (Gun metal) cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified.
20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) fixed in repairs, complete all as specified
PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed.
Vitreous china wash down water closet pan pedestal pattern in white colour with 'P' or 'S' traps excluding seat cover, flushing cistern and flush pipe fixed in repairs complete all as specified and directed. Cat Part No-20011 (SLICK) of Hindware or equivalent cat part of make NEYCER, CERA, PARRYWARE as approved by GE.
Plastic water closet seat cover white in colour closed pattern with flat bottom and mild steel chromium plated or aluminium hinging devices, complete all as specified and directed.
Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.2 meter long flexible spirochrome flex tube and ABS wall hook including making connections and fixed in repair in position complete in all respect as specified.Make-Jaquar Cat part no. ALD-573 or its equivalent cat part of make specified in list make, as approved by GE.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'P' trap fixed in repairs complete all as specified and as directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make NEYCER, CERA, PARRYWARE as approved by GE.
Vitreous china wash basin, white, flat back, size 550x400mm with pedestal including CP mixer for mixing hot and cold water for pipe of bore 15mm, waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets and waste pipe etc., fixed in repairs complete all as specified and as directed. Cat Part No. 10036 of Hindware (Model-Windsor) or equivalent cat part of make NEYCER, CERA, PARRYWARE as approved by GE.
PVC connection 15mm size with PTMT nuts on both ends of length 600mm fixed, complete all as specified and as directed.
Chromium Plated stainless steel towel rail 20mm dia 'D' type 60 cm long between flanges fixed in repairs Make-Jaquar cat part no. AKP-35711PS or its equivalent cat part of make specified in list make, as approved by GE.
Brass chromium plated shower rose 125mm size with or without swivel joints, with arm any size, including fixing to steel pipe or union complete all as specified and directed
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), including all fittings, heads , shoes bends , swan-necks etc. complete all as specified and as directed.
S&F in repairs 110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed.
S&F in repairs 75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc all as specified and directed.
S&F in repairs 110mm bore PVC Bends any radius with oval access door complete all as specified and directed.
S&F in repairs 75mm bore PVC Bends any radius with oval access door complete all as specified and directed.
PVC SWR 110mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
PVC SWR 75mm dia Type-B ( pressure not less than 6 kg /cm2) pipes in any length fixed to walls with PVC/MS holder or clamps and conforming to IS-1729 complete all as specified and directed.
110mm bore PVC Bends (any radius) diminishing pieces or tapers (larger bore measured) for pvc pipes complete all as specified and directed.
S & F PVC branch pipes 110mm single equal or unequal ordinary or inverted (spigot or socket type) fixed in repair with paralled branches all as specified and directed.
110mm PVC (SWR) junction single, (single T) equal or unequal provided with access door, complete all as specified and directed.
PVC junction, single (single Y), equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore with access door, complete all as specified and directed.
PVC cowls 75mm fixed in repairs complete all as specified and directed.
PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified.
Plate rack made of stainless steel 0.8mm thick overall size 786mm x 610mm x 254mm complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel (1mm thick) kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm as approved by Engr-in-Charge complete all as specified and directed.
S & F in repair CP angle valve/concealed stop cock (weight not less than 0.40Kg as mentioned in SSR part- 1 clause no. 18.14.2)of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore complete all as specified and directed.
S & F in repair 15 mm CP Bib taps (Long body and weight not less than 0.40Kg as mentioned in SSR part- 1 clause no. 18.14.2) , fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
CP Brass wall mixture with Telephonic shower arrangement for mixing hot and cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type as in repairs complete all as specified and directed.
Brass chromium plated fancy type wall mixture for mixing of hot and cold water supply screwed down including connecting leg & wall flange for iron pipe 15 mm bore fixed in repair complete all as specified and as directed by Engineer-in-Charge.
Stainless steel Soap dish, any type, fixed with plugs chromium plated brass screws fixed in repairs complete all as specified and as directed.
Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf with chromium plated bracket guard complete all as specified and directed.
Toilet paper holder of white vitreous china, box type fixed to plug with chromium plated brass screwscomplete all as specified and as directed.
Fabrication and fixing of Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary , gusset plates, riveting etc n exc 10 Kg each brackets, conforming to Fe.290. Gde E-165 (Brackets over 10 Kg each to be measured under "Structural Steel") Complete all as specified and directed.
Bathroom mirror cabinet 400 x 500mm fixed to wall including complete accessories. Make : Prayag Cat Part No-554 or its Equivalent of Hindware, Cera as approved.
Pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs including use and waste of necessary formwork complete all as specified and directed.
TMT Bar 8mm dia bar and over cut to length, bent to shape required including cranking, bending, hooking ends, binding, with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 mm diameter incl bends, complete all as specified and directed.
RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed.
Concrete bed to drain pipes 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 in half brick thick, complete all as specified.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint , complete all as specified and as directed.
Preparation of old treated plastered or un plastered wall surfaces including washing,scrubbing down and stopping of distermperd surfaces and applying two coats of oil bound distemper, complete all as specified.
Washing, rubbing down and stopping of distempered/ painted surfaces with preparation of old surfaces and applying two coats of cement base paint to walls complete all as specified and directed.
75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in bays complete including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified and as directed.
20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed. Note:-(Size of Kota Stone slab shall not be less than 52 cm x 52 cm).
-Ditto- All as per item No 120 above but in skirting/dado fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed.
Rolled mild steel structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
Pre- painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
4mm thick prelaminated designer ceiling board over & including GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm fixed along wall perimeter, main runner 'T' of size 25x40x3mm , secondary runner 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels, complete all as specified and as directed.
35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, complete all as specified.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed.
Taking down old unserviceable sub main wiring and supply and fixing Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly including making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed. (Make - Havells, KEI, Anchor.) Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
All as per item No-133 above but for One light point/fan /bell point controlled by one switch.
All as per item No-133 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per item No-133 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per item No-133 here-in-before one light point controlled by two way switch
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers are to be used of same make/brand only and shall be deemed in to included in quoted rate only.) for One 15 amps power socket outlet point controlled by one 16 amps switch on independent board.
Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and directed.
Modular type switch 6 Amps, single pole, 2way,1 module, 240V, ISI Marked Complete all as specified and directed.
Modular type switch 16 Amps, single pole, 1way, 1/2 module, 240V, ISI Marked Complete all as specified and directed.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed.
Modular type socket 16 Amps, 2/3 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed .
Fan regulator modular type electronic compatible with BLDC fan, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed.
Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge.
Modular Bell push 6A 1 module, 240V, ISI Marked Complete all as specified and directed. “Cat part No ACVSBXW061 of Crabtree (Havells) or its equivalent cat part of make make Anchor, Legrand, Schneider as approved by GE”.
20 Watt LED batten/inverter capacity and polycarbonate channel, lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed . (Make- Pride plus inverter batten 4 feet, 20W 6500K of Havells or equivalent in Bajaj, Surya, Wipro as approved).
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V general purpose surface and wall mounted LED batten with Auminium housing integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete incl testing after fixing all as specified and directed. Make: ''Cat part No lumiline+BS 10 Watt LED 865 SP CSS of Havells or equivalent in HPL, Bajaj, Surya as approved''.
LED light fitting 1x20W, 220V, general purpose surface and wall mounted LED batten with Auminium housing integrated electronic driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and removal old unsv fitting complete all as specified and directed. Make: LUMILINEOBS20WLED840SPCWH of Havells or equivalent in HPL, Bajaj, Surya, Benlo as approved''.
35 Watt LED energy saving light fitting environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed. (Make- Havells, cat part No ENDURASUNDOWNSL35WLED765PASYBOPC or Bajaj/Philips/Crompton Greaves or its equivalent).
Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) including taking down old unsv fan, complete all as specified and directed. Make:- Cat Part No Zinger of Make Havells or its Equivalent cat part of make-BAJAJ,CROMPTON GREAVES, GEC, KHAITAN,ORIENT as approved by GE
VTPN verticle loadline double door distribution box (DB) fitted with Bus bar neutral link, blanking plates of 4 way with suitable for incomming MCCB 'I/C' frame,having isolated neutral bar, mechanical impact strength IK09,door earthing suitable for MCCB upto 125 Amp including MCCB complete all as specified and as directed. “Cat part NoDHDPTVODRW04 of Havells, or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
MCCB 04 pole 415 volts 16 KA, 63 Amp adjustable thermal & fixed magnetic setting type suitable for TPN vertical loadline DB fixed in replacement, complete all as specified and as directed. Make : Havells Cat part No IHDA3BBF0063 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE..
Sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp rated bus bar including blanking plates where required complete all as specified and as directed. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Supply & fixing and in repair MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.Make:- Legrand cat No.4085 87 to 4085 95 / Hager Cat Ref No.NCN106N to NCN132N / Havells Cat No.DHMGCSPF006-032 as approved
MCB's single pole & neutral 240 volts 40 to 63Amps 10 KA 'C' series, all as specified and as directed by Engr -in-Charge. Make: Havells Cat Part No.DHMGCSNF040-063 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Note: Old unsv geyser shall be deposited in MES yard. Make : Havells(Monza EC),or equivalent cat part of make as specified in list of make here-in-after.
S&F Exhaust fan single phase PVC/Sturdy engineering plastic body 230V 50 Hz of size 250mm sweep ISI marked with louvers shutter complete with all accessories including connecting up from ceiling rose complete all as specified and directed. Note: Old unsv exhaust fan shall be deposited in MES yard. Make:- Cat part No refresh air SPS of Havells or its Equivalent cat part of make as specified in list of make here- in after.
S&F Exhaust fan Metal (Steel) body AC single phase 230V 50 Hz of size 300mm sweep including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat No Ventil DX-WH/BLK or equivalent in bajaj, Crompton Greaves etc. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 amp 240 volts and connecting electrically including taking down unserviceable MCB complete all as specified and directed.
Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- For payment purpose, only punned thickness shall be measured.
Supply & fixing angle lamp holder, insulated body with back plate for LED lamp including removing old unsv item complete all as specified and directed.
LED bulb 12 watts, 240Volts,50Hz pin type and including removing old unserviceable item complete all as specified and directed. Cat Part No-BL0212WB22 of BENLO or its equivalent in Bajaj, Surya as approved.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core, complete all as specified and as directed.
DWC HDPE tubing 50mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
S&F Exhaust fan, steel body AC single phase, 230 volt of size 380mm sweep with blades frame and louvers and necessary fixing arrangement such as nuts, bolts, washers and connecting up from ceiling rose complete all as specified and directed. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
PACHNANDA BUILDERS (BID ID -3087570)
bushan kumar (BID ID -3094346)
M/s Rajesh Kumar Contractor (BID ID -3084856)
M/s Sekinder Paul Sharma (BID ID -3087827)
CHOPRA CONSTRUCTIONS (BID ID -3085362)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .