Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAdmitted-Finance | ₹3.3 L | L1 | Admitted-Finance |
| 2 | L2₹3.3 LAdmitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | ₹3.3 L | L2 | Admitted-Finance |
| 3 | L3₹4.8 LAdmitted-Finance | ₹4.8 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not fullfil PQR |
| 5 | Rejected-Technical MEERUT UTTAR PRADESH 250110 INDIA UDYAM UP 56 0008622 | MEERUT | UTTAR PRADESH | 250110 | - | - | Rejected-Technical Not fullfil PQR |
| Sl No | Description | Qty | Unit | P&H Engineering L2 | Technocrat Electrical L3 | SHASHI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Details of Work/Supply. | ||||||
| 1.01Providing & Fixing of Vaccum Interrupter of Shreem Make having Specifications like rating 1600Amp., 36 KV, Type- SHROD-36 suitable for 33 KV VCB (Shreem make) as per technical specification and sample, in the defective breaker poles available at following sub-stations under ETD Hamirpur | ||||||
| 1.02 | 132 KV S/S Rath | 1 | No. | 28,700 ₹28,700 | 30,000 ₹30,000 | 28,500 ₹28,500 |
| 1.03 | 132 KV S/S Sarila | 3 | Nos. | 28,700 ₹86,100 | 30,000 ₹90,000 | 28,500 ₹85,500 |
| 1.04 | 132 KV S/S Patara, Hamirpur | 3 | Nos. | 28,700 ₹86,100 | 30,000 ₹90,000 | 28,500 ₹85,500 |
| 1.05Providing & Fixing of Vaccum Interrupter of CGL Make having Specifications like rating 1600Amp., 36 KV, Model-OVB-VBF 36.16.25 suitable for 33 KV VCB (CGL make) as per technical specification and sample, in the defective breaker poles available at following sub-stations under ETD Hamirpur | ||||||
| 1.06 | 132 KV S/S Rath | 1 | No. | 28,600 ₹28,600 | 30,000 ₹30,000 | 28,500 ₹28,500 |
| 1.07Providing & Fixing of Vaccum Interrupter of ABB Make having Specifications like rating 1250Amp., 36 KV, Type- VBF 36.16.25 suitable for 33 KV VCB (ABB make) as per technical specification and sample, in the defective breaker poles available at following sub-stations under ETD Hamirpur | ||||||
| 1.08 | 132 KV S/S Bharua Sumerpur | 2 | Nos. | 28,600 ₹57,200 | 30,000 ₹60,000 | 28,500 ₹57,000 |
| 1.09 | After replacement of Vacuum Interruptor following tets to be carried out :- i- Checking & adjustement of snatch gap, travel of drive insulator rod & tie rod of each pole. ii- Opening & closing time of breaker of each pole. iii- Carrying out Contact Resistance Measurement (CRM test) of each pole. iv- Checking of megger values of breaker poles. v- Checking triping of breaker at 70% DC voltage. vi- Checking the CLOSE/OPEN operation of breaker from REMOTE & LOCAL. | 10 | Job | 4,800 ₹48,000 | 18,000 ₹1.8 L | 4,700 ₹47,000 |
Updated dates
Tender Value
₹4.0 L
EMD Value
₹4,000
Closing Date
10 Feb 2026, 3:00 pmClosed
SE ETC Banda
SE ETC Office, 220 KV S/S Tindwari Road, Banda
WORK FOR PROVIDING AND FIXING OF VACUUM INTERRUPTOR IN DEFECTIVE BREAKER POLES OF 33 KV VCB (SHREEM, ABB, CGL MAKE) AT DIFFERENT SUB STATIONS UNDER ETD HAMIRPUR.
2025_UPTCL_1103094_1
T-54/ETC(B)/2025-26
Open Tender
Electrical Works
60 days
Banda
As per tender document.
2 documents required · 2 mandatory
₹590
As per NIT
₹4,000
10 Apr 2026
31 Dec 2025
11 Feb 2026
31 Dec 2025
10 Feb 2026
31 Dec 2025
Details of Work/Supply.
Providing & Fixing of Vaccum Interrupter of Shreem Make having Specifications like rating 1600Amp., 36 KV, Type- SHROD-36 suitable for 33 KV VCB (Shreem make) as per technical specification and sample, in the defective breaker poles available at following sub-stations under ETD Hamirpur
132 KV S/S Rath
132 KV S/S Sarila
132 KV S/S Patara, Hamirpur
Providing & Fixing of Vaccum Interrupter of CGL Make having Specifications like rating 1600Amp., 36 KV, Model-OVB-VBF 36.16.25 suitable for 33 KV VCB (CGL make) as per technical specification and sample, in the defective breaker poles available at following sub-stations under ETD Hamirpur
132 KV S/S Rath
Providing & Fixing of Vaccum Interrupter of ABB Make having Specifications like rating 1250Amp., 36 KV, Type- VBF 36.16.25 suitable for 33 KV VCB (ABB make) as per technical specification and sample, in the defective breaker poles available at following sub-stations under ETD Hamirpur
132 KV S/S Bharua Sumerpur
After replacement of Vacuum Interruptor following tets to be carried out :- i- Checking & adjustement of snatch gap, travel of drive insulator rod & tie rod of each pole. ii- Opening & closing time of breaker of each pole. iii- Carrying out Contact Resistance Measurement (CRM test) of each pole. iv- Checking of megger values of breaker poles. v- Checking triping of breaker at 70% DC voltage. vi- Checking the CLOSE/OPEN operation of breaker from REMOTE & LOCAL.
Note:- 1. In this work estimate all T&P, special T&P, testing kit and manpower will be arranged by contractor at his own cost. 2. Materials like grease, oil, sand paper etc. will be arranged by contractor at his own cost. Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra .
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_2034168.pdf
techsummary_2034168.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
TenderDocumentT54.pdf
Tender Documents • 0.86 MB
BOQ_2034168.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid