| 1 | L1₹3.4 CrAccepted-AOC 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹3.4 Cr Quoted ₹3.5 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹3.8 Cr+₹29.3 L (8.41%)Rejected-Finance H NO 352 SECTOR 1 CHANNI HIMMAT JAMMU J K 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹3.8 Cr+₹29.3 L (8.41%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹3.9 Cr+₹37.4 L (10.7%)Rejected-Finance NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | ₹3.9 Cr+₹37.4 L (10.7%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹3.9 Cr+₹40.7 L (11.7%)Rejected-Finance | ₹3.9 Cr+₹40.7 L (11.7%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹4.1 Cr+₹59.2 L (17.0%)Rejected-Finance | ₹4.1 Cr+₹59.2 L (17.0%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹4.3 Cr
EMD Value
₹5.0 L
Closing Date
8 Aug 2022, 6:00 pmClosed
Chief Enngineer Pathankot Zone
HQ Chief Engineer Pathankot Zone
ADDITION ALTERATION AND REPAIRS OF OFFICERS JCOS AND OR MARRIED ACCOMMONDATION AT MILITARY STATION KALUCHAK
2022_MES_534560_1
CEPZ-15/2022-23
Open Tender
Civil Works
Item Rate
365 days
GE Kaluchak
All as per tender documents
7 documents required · 7 mandatory
₹2,000
GE Kaluchak
₹5.0 L
Yes
29 Sept 2022
29 Jun 2022
15 Aug 2022
29 Jun 2022
8 Aug 2022
25 Jul 2022
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Demolition of cement concrete (unreinforced) or tiling etc in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Demolition of cement concrete (Re-inforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified and directed..
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specified provided for complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing with neat cement slurry with 3.0 kg of cement per Sqm , complete all as specified and directed.
Taking down cement plaster/wall tiles including backing etc from brick/stone walls/ concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified and directed.
Taking down shutters of any description exc. 1 Sqm and not exc 2 Sqm each, complete all as specified and directed.
Taking down, easing and adjusting shutters of any description, exceeding. 1.00 Sqm and not exceeding 2.00 Sqm each and re-fixing in the same opening, complete all as specified and directed.
Material and labour brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
Material and labour Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e using serviceable bricks obtained from Srl item No. 01 here-in-before, complete all as specified and directed.
Supply and fixing Pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and directed.
Supply and fixing Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and directed. Note : PCC for filing of hollow portion back of chowkats shall be measured and paid for separately.
Material and labour PCC 1:3:6 nominal mix type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats, complete all as specified and directed.
Material and labour PCC 1:2:4 type B-1 using 20mm graded aggregates as in anchoring hold fast, parapets, coping, apex plates, bed plates and the like including weathering slightly rounded or chamfered angles and throating etc, complete all as specified and directed.
Supply and fixing 35mm thick 2nd hard wood (Sal/Hollock), glazed and skeleton shutters (factory made),open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., etc., size of members of shutters as specified in clause 8.24 (a) of SSR 2009 Part-I, complete all as specified and directed.
All as per item ser no 17 here-in-before but partly panelled shutters (bottom portion) & partly Skelton shutter (top portion) suitable for fly proofing.
Supply and fixing 35mm thick factory made 2nd class hard wood (Sal/holloc) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial face veneers on both sides. The size of rail and style as per IS-1003 Par-I, kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
Supply and fixing Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass will be measured and paid separately) with side hung shutters with MS peg stay dovetailed or welded incl 02 Nos, MS Tower bolts 150 mm long for each leaf and 8mm square bar grill / guard bars at spacing as shown on Drg welded to MS flat iron frame work, including other fittings, hinges, MS handles, tarred hold fasts, PCC blocks for hold fasts etc all as shown on Drg No CEPZ/TD – 354/09 sheet 1/3 to 3/3 including one coat of red oxide primer, complete all as specified and directed.
Supply and fixing powder coated aluminium sliding window (three track) consisting of two shutters of glazed and one shutter of flyproof. Note : The item shall be included as following : (a) Aluminium powder coated frame of section 100mm x 44mm x 1.5mm with or without rebate. (a) Aluminium powder coated window shutters of section 40mm x 20 mm x 1.5 mm thick (Two shutter of glass and one shutter of wiremesh) incl self locking catch & roller etc). (c) 5.5 mm thick coloured or tinted glass glazing as in aluminium door/window/ventilator with aluminium hollow beading/glazing clip (included with shutters) size 19mm x 17mm made out of 0.70mm thick hollow section weighing not less than 0.97 kgs/RM including rubber gasket (d) Stainless steel wire cloth, 0.36 mm nominal dia of wire average width of aperture 1.40 mm and fixed with stainless steel wire staples.
Supply and fixing powder coated aluminium sliding window (Two Tracks) consisting of two shutters of glazed and flyproof mesh fixed on external face of window frame. Note : The item shall be included as following : (b) Aluminium powder coated frame of section 63.5mm x 38.10 mm x 1.02 mm thick with or without rebate. (b) Aluminium powder coated window shutters of section 40mm x 18 mm x 1.25 mm thick (Two shutter of glass and one shutter of wiremesh) incl self locking catch & roller etc). (c) 5.5 mm thick coloured or tinted glass glazing as in aluminium door/window/ventilator with aluminium hollow beading/glazing clip (included with shutters) size 19mm x 17mm made out of 0.70mm made out of 0.70 thick hollow section weighing not less than 0.97 kgs/RM including rubber gasket. (d) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples and aluminium beads.
Material and labour for framed work as in grills, gratings etc with end of bars shouldered or riveted or forget into spikes, framed guard bars confirming to Fe- 290, Gde-E-165. Note : Grills (8 mm squre bars) shall be fixed in wall with steel screws not less than 100mm long as inner face of aluminium windows, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing brass door magic eye: as given specification material resin lens +zinc alloy, top diameter 31.2mm, bottom diametre approx 24mm, pipe diametre approx 16mm total length approx 50mm, inner height approx 36mm application 35mm to 60mm thick viewing angle 200 degree of surrounding without opening the door unique design ultra clear view and superior finish, wide angle best in class lens for all round visibility the outsider cannot hide any ware, the back cover protects you from the outsider observing any movements inside easy to install with inbuilt screw over a wide range of door thickness from 35mm to 60mm etc required at site, complete all as specified and directed.
Supply and fixing 2nd class Hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints , supplied and fixed, complete all as specified and directed.
Supply and fixing Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR-2020 Part-II, complete all as specified and directed.
All as per item ser no 26 here-in-before but wood grain printed PVC sheet used instead of plain colour PVC sheet and edges will be painted to match with painted sheet, complete all as specified and directed.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet 5mm thick to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplied & fitted in the frame at site as per specification & drawings shown in SSR-2020 Part-II, complete all as specified and directed.
All as per Srl Item No.28 above but wood grain printed PVC sheet used instead of plain colour PVC sheet & 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mmx10mm (900) used instead of exposed portion of PVC sheet beading including bolt to hinge plate and fixed with screws.
Material and labour for Hasp and staple 100mm in size, aluminium anodised, including bolt to hinge plate and fixed with screws, complete all as specified and directed.
Supply & fixed in repair 18/19 mm thick Pre laminated particle board, exterior grade, pre laminated one side with decorative choice lamination and other side balancing white lamination, including necessary wooden or PVC lipping all around fixed with screws/nails to timber frame or wooden cleats work as in shelves of cupboards etc, complete all as specified and directed.
Material and labour for 18mm thick BWR grade marine ply for shutters/shelves/kitchen cabinet/drawer covered with 1mm thick designer laminated sheets and back side covered with 0.80 mm thick designer laminated sheet, glossy finish with 2mm thick PVC lapping (edge band) to be fixed with hydraulic press at factory including pressing lipping and back sides covered,complete all as specified and directed.
Supply and fixing Stainless steel fasteners of size 75mm long steel supports, fixed to walls, complete all as specified and directed.
Material and Labour for 8mm thick coloured or linted glass glazing as in shelves of kitchen cabinet fixed with wooden cleats etc, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for rolling sliding channels of size 450mm length, fixed as in cupboard drawers with screws, complete all as specified and directed.
Supply and fixing Zero crank hinge, heavy duty, self closing type as in shutter of cupboards in kitchen, ccomplete all as specified and directed.
Supply and fixing Stainless steel designer handle (heavy duty) of 100mm size, fixed to drawers or cupboard shutters, complete all as specified and directed.
Supply and fixing 25 mm dia stainless steel rod as in cloth hanging rod fixed with wooden cleats/brackets complete all as specified and directed.
Supply and fixing for Butt hinges 100mm long, stainless steel, medium weight and fixed, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed ccomplete all as specified and directed.
Aluminium, anodised, barrel tower bolts 200mm of extruded section and fixed, complete all as specified and directed.
Aluminium, anodised, barrel tower bolts 150mm of extruded section and fixed , complete all as specified and directed.
Aluminium, anodised, handles 150mm of extruded section and fixed, complete all as specified and directed.
Aluminium, anodised, handles 125mm of extruded section and fixed, complete all as specified and directed.
S&F for floor door stopper of 140mm long cover plate of aluminium alloy body and tongue anodised with hard drawn steel spring, fixed in floor, complete all as specified and directed.
Mild steel, 300mm, ordinary rat tail rod patterm springs including roller and roller plate complete fixed with screw or necessary welding to pressed steel door frame, complete all as specified and directed.
Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in repair with stainless steel wire staples, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new onces exc 1.5 Sqm, complete all as specified and directed.
S&F, 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc. 0.5 sqm in each pane, complete all as specified and directed..
3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square n exc. 0.5 sqm each, complete all as specified and directed.
Supply and fixing in repair 25mm outer dia stainless decorative drapery rod (Model No. SS-25FL of Vista) of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel wings (Model No. SS CRNG of Vista) with 50 mm dia and proportionate for part there off, with stainless steel brackets (Mode No. SS 25 BR, Vista) near to ends with stainless finials (Model:- SS-1 of Vista with adapter) for 25mm dia drapery rod at both ends. Note :- The drapery rod shall be projecting 150mm outer side from the clear opening of doors / windows (Including necessary fittings), complete all as specified and directed.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for re fixing or removal to store with all fittings, complete all as specified and directed.
Cutting chases, pining in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc , and cutting chases for concealed water tubing, etc, and making good, cutting not exc 20 cm girth in brick walls, complete all as specified and directed.
Supply & fix CPVC (Chlorinated poly vinyl chloride) pipes, bore (inner dia) of pipe in 15mm of pressure rating 10kg/cm2 fixed complete to walls, ceiling or in floors etc, any type of pipe. Note :- The rate for pipe including all pipe fittings such as ends, elbows, unions, tees reducing tees, adapters, sockets, plugs, house clips as well as brass threaded fittings for all opening / connections such as bib tap / stop valve etc, complete all as specified and directed.
Supply & fixed steel water tubing 15mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling or laid in floors, complete all as specified and directed.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors to walls and including cleaning for re fixing or removal to store with all fittings, complete all as specified and directed.
Supply & fix CPVC (Chlorinated poly vinyl chloride) pipes, bore (inner dia) of pipe in 20mm of pressure rating 10kg/cm2 fixed complete to walls, ceilings or in floors etc. Any type to pipe, complete all as specified and directed. Note :- The rate for pipe including all pipe fittings such as ends, elbows, unions, tees reducing tees, adapters, sockets, plugs, house clips as well as brass threaded for all opening / connections such as bip taps / stop valve etc, complete all as specified and directed.
Re fixing old steel tubing 20mm bore and connections in new or old position (walls, ceiling, floor etc), complete all as specified and directed.
Supplied and fixed Rotational moulded polyethylene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR 2009 Part-I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high – density plastic bal screwed for iron pipe and fixed. (Minimum weight 20 mm -210 gms including Dismantling of old broken water tanks and re fixing of inlet, & over flow pipe etc , complete all as specified and directed.
Supplied and fixed Rotational moulded polyethylene water storage tanks three layers of 1000 ltrs capacity ISI marked (Cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR 2009 Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high –density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm -210 gms including Dismantling of old broken water tanks and refixing of inlet, outlet & over flow pipe etc, complete all as specified and directed.
Supply & fix CPVC (Chlorinated poly vinyl chloride) pipes, bore (inner dia) of pipe in 25mm of pressure rating 10 kg/cm2 fixed complete to walls, ceilings or in floors etc. any type of pipe, complete all as specified and directed. Note :- as overflow pipe extended upto rain water pipe or 45 cm beyond external face of wall
Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 20mm bore and fixed, complete all as specified and directed.
Bip tap 15mm bore long body, Brass CP, fancy type (long shank), with crutch or butterfly handle screwed down screwed for iron / PVC pipe or for brass ferrule and fixed, complete all as specified and directed.
Stop valve / angle valve (ISI Marked), fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron / PVC pipe or for unions of 15 mm bore and fixed in repair , complete all as specified and directed.
Supply & fixed overhead shower, 65mm ABS shower (without arms), complete all as specified and directed.
Supply and fixed Soap dish cantabile – clea (material SS finish, glossy) fixed to plugs with CP brass screws, complete all as specified and directed.
S&F in repair corner glass shelf with bracket fixed with chromium plated brass screws and wooden / plastic cleats, complete all as specified and directed.
Supply & fixed in repair, Vitreous china squatting pan of pattern, long pan, ‘Orissa pattern’ size 580mm x 440 mm white with integral foot rest (excl flushing cistern and flush pipe) but including provision of lime concrete, complete all as specified and directed.
Supply & fixed repair, Vitreous china wash down water closet pan (Pedestal pattern) white (excl fixing bolts, flushing cistern and flush pipe) but including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device, complete all as specified and directed.
Supply and fixing in repair Hand Shower (Health Faucet) with 8mm dia 1.2 m long Flexible Tube Chrome Finish & Wall Hook for Water closet, complete all as specified and directed. Make :- Jaquar CAT No. Health Faucet SKU ALD-573 or equivalent in any of the make mentioned in appx 'F' list of makes/maufactureres/producers.
S&F toilet paper holder, Brass CP, with brass CP screws, complete all as specified and directed.
S&F in repair stainless steel towel rack 600mm long with lower hanger, fancy type, superior quality, fixed with and including chromium plated screws and wooden / plastic cleats, complete all as specified and directed.
Supplied and fixed in repair CP brass towel ring 20mm dia, fancy type, superior quality fixed with and including chromium plated screws and wooden/plastic cleats, complete all as specified and directed. Make: ACN-1121BN of JAQUAR or equivalent in any of the make mentioned in appx 'F' list of makes/maufactureres/producers.
Supply and fixed in repairs 15mm bore brass wall mixer 3-in-1 system with Provision for both hand Shower and Overhead Shower complete with 115mm Long Bend pipe, connecting Legs & wall Flange mixing hot and cold water, screwed down for 15mm dia iron pipe, complete all as specified and directed. Note :- Hand shower & over head shower will be measured and paid separately. Make : CON-SOL 6281 of JAQUAR or equivalent in any of the make mentioned in appx 'F' list of makes/maufactureres/producers.
Supply and fixing in repair Hand Shower dia 105 mm round shape single flow with air effect (ABS BODY & FACE PLATE CHROME PLATED) with rubit cleaning system including shower flexible tubes 8mm dia & 1.5 m long with nuts , complete all as specified and as directed by Engineer-in-Charge. Make : Jaquar CAT No. HSH-1717 & SHA 549D8 or equivalent in any of the make mentioned in appx 'F' list of makes/maufactureres/producers.
Supply and fixing Centre hole basin mixer without popup waste system with 450mm long braided hoses cast copper alloy for iron pipes 15mm bore, screwed for iron pipe and fixed, complete all as specified and directed.
Supply and fixing Sink mixer with regular spout brass CP for iron / pvc pipes 15mm bore, screwed for iron pipe and fixed, complete all as specified and directed.
Supply & fixed in repair PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle (incl brackets & flush pipe PVC 32 mm dia) capacity of 10 Litres , complete all as specified and directed.
Material and labour for (a) 15mm thick plaster in cement sand mortar (1:3) mixed with water proofing compound, all as per manufacturer’s instructions shall be applied both on floor and wall. The surfaces then shall be cured and allowed to dry. All the joints of pipe shall be sealed properly, complete all as specified and directed. Note :- Provision of spout pipe as extended 45 cm beyond external face of wall to be measured and paid separately). (b) Apply a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane Based Liquid Membrane on floor as well as on wall as per manufacturer’s instructions, after the treatment over, sunken portion shall be kept full of water for at least one week to check that no seepage is seen from the external wall/concrete surfaces
Material and labour Cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in mass filling in sunken slab of toilets, complete all as specified and directed.
Supplied and fixed sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x 460 mm and bowl size 410 mm x 330 mm x 160 mm, complete all as specified and directed.
M&L stainless steel plate rack (Utensil Rack) of size (900mm x 750 mm x 250 mm) made out of AISI 304 stainless steel 0.63 mm thick sheet fixed with brass screw of required size including necessary fittings / nuts, bolts & washers, complete all as specified and directed.
Supply & fixed, Vitreous china wash basin, white flat back, size 500mmx400mm excluding taps, waste chain and plug and porcelain stopper but including vitreous china pedestal and PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32mm dia complete all as specified and directed.
S&F Corner type wash hand basin, round, white of size 400mmx400mmx125mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets and PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32 mm dia, complete all as specified and directed. Make : PRYAG, Cat No. 4655 or equivalent in any of the make mentioned in appx 'F' list of makes/maufactureres/producers.
S&F 32mm dia, Low density polyethylene pipes (LDPE) of pressure rating 6 kg / cm2 suitable for waste pipe etc fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
Supply & fixed in repair, Pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanks and fly nuts screwed for 15 mm dia bore of pipe complete all as specified and directed.
Brass CP towel rail 20mm dia ‘D’ type 60cm long between flanges complete all as specified and directed.
Supply and fixing Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
Supply and fixing stainless steel, Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed.
Supply & fixed, PVC connection 15mm bore with PTMT nuts of length 450mm long complete all as specified and directed.
Material and labour PVC (SWR) floor trap, dia of outlet in 75mm, plain excluding grating, but including jointing with solvent cement fixed in repair complete all as specified and directed.
Supply & fixed PVC grating square, 150mm (Hinge pattern and with or without hole) complete all as specified and directed..Make : PRYAG, Cat No. 115 or equivalent in any of the make mentioned in appx 'F' list of makes/maufactureres/producers.
Supply & fixed in repair, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply & fixed 110mm bore PVC (SWR) bends any radius, with or without assess door complete all as specified and directed.
Supply & fixed 110 mm bore PVC (SWR) branch pipes, with or without assess door, single (Single Y) equal or unequal with excess door complete all as specified and directed.
Supply & fixed 110 mm bore PVC (SWR) branch piece, with assess door, double (double Y) equal or unequal, with or without assess door complete all as specified and directed.
Supply & fixed, 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with assess door complete all as specified and directed.
Supply & fixed, 110 mm bore PVC (SWR) junction double, (double T), equal or unequal, with assess door complete all as specified and directed.
Supply & fixed, 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
Supply & fixed in repair, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
Supply & fixed in repair,75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
Supply & fixed in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Supply & fixed, 75mm bore PVC (SWR) bends any radius, with or without excess door complete all as specified and directed.
Supply & fixed, 75mm bore PVC (SWR) branch piece, single (Single Y) equal or unequal, with access door complete all as specified and directed.
Supply & fixed, 75mm bore PVC (SWR) branch piece, double (double Y) equal or unequal with access door complete all as specified and directed.
Supply & fixed, 75 mm bore PVC (SWR) junction single, (Single T), with access door, equal or unequal complete all as specified and directed.
Supply & fixed, 75mm PVC (SWR) junction double, (double T), with access door, equal or unequal complete all as specified and directed.
Material and labour Vitrified light shade ceramic tiles 10mm thick (Square / rectangular) polished area of each tile not exceeding 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Material and labour Vitrified light shade ceramic tiles 10mm thick (Square / rectangular) polished area of each tile not exceeding 0.36 Sqm in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in cement mortar 1:3, complete all as specified and directed.
Material and labour Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed and pigment to match over and including 15mm thick screed layer in cement mortar 1:4 , complete all as specified and directed.
Material and labour Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm in skirting etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 10mm thick screed layer in cement mortar 1:3, complete all as specified and directed.
Material and labour Non skid ceramic joint less coloured tiles, 7 to 8 mm thick (square / rectangular) area of each of each tile exc. 0.11 sqm but n exc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Material and labour Non skid ceramic joint less coloured tiles, 7 to 8 mm thick (square / rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Material and labour Glazed ceramic coloured tiles of size 450mmx 300mm thickness 7mm as in vertical surfaces such as skirting, dado, wall etc set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm , complete all as specified and directed.
Material and labour 20mm thick granite black (of any type) work (table rubbed & polished) in steps, jambs, pillars window –cills cooking plate forms & like including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite laid over and including screed bed or bedding layer of morter 15mm thick for laying floor in CM 1:4 finished even & rough to receive top layer, complete all as specified and directed.
Material and labour Machine cut Kota stone slab flooring not less than 18 to 20 mm thick (size of stone shall not less than 55cm x 55cm), 75mm wide white marble border around, laid over & including 15mm thick screed base in CM 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirrior finish with machine, complete all as specified and directed.
Material and labour Machine cut Kota stone slab not less than 18 to 20mm thick as in riser of steps, skirting, dado and pillar laid over & including 15mm thick screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified and directed.
Material and labour 25mm thick (average thickness) PCC1:2:4, type B-O using 12.5mm graded stone aggregates as floor by maintaining required gradient / undulation, finished even and fair, complete all as specified and directed.
Material and labour Rendering 10mm thick plaster in cement mortar 1:3 on concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour Rendering 15mm thick on fair face of brick work or concrete surface in CM 1:6, finished even and smooth without using extra cement upto triple storey building complete all as specified and directed.
Material and labour Rendering 15mm thick on fair face of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement upto triple storey building, complete all as specified and directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building, from roof projection, chajja etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound as per manufacturers instruction or PCC 1:2:4 type B-O (using 12.5mm graded crushed stone aggregate) including necessary form work and finally finished the surface with 15mm thick cement plaster in CM 1:3, complete all as specified and directed.
Material and labour for 50mm thick cement concrete 1:2:4, type B2 (using 40mm graded agg) as in plinth protection finished even and smooth using extra cement. (incl necessary joint filling with mixture of paving bitumen & sand in 1:3) complete all as specified and directed.
Material and labour Preparation of newly plastered surface of wall & applying 2mm thick Acrylic wall care putty on wall surfaces, complete all as specified and directed.
Material and labour Preparation of old plastered surface of wall & applying 2mm thick Acrylic wall care putty on wall surfaces, complete all as specified and directed.
Material and labour Preparation of newly plastered surface of wall and applying two coats of oil bound distemper, white or tinted shade, complete all as specified and directed.
Complete removal of existing treatment of wall surfaces and applying two coats oil bound distemper, white or tinted shade, complete all as specified and directed.
Material and labour Preparing newly plastered or concrete surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
Complete removal of existing treatment of wall surfaces and applying two coats of Cement base paint complete all as specified and directed.
Complete removal of existing treatment of external wall surfaces such as RCC fins/facials/roof projection etc and applying two coats of all weather coat or Appex paint complete all as specified and directed.
Material and labour for preparing newly plastered surfaces and applying three coats of white was as in ceiling etc complete all as specified and directed.
Material and labour for preparing of plastered surfaces of ceiling, old decorated surface and applying two coats of white was complete all as specified and directed.
Material and labour for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of re-oxide primer complete all as specified and directed.
Material and labour for preparing of Old painted surfaces of steel or iron surfaces of any description, over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparing of new or previously untreated surfaces of wood of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and labour for preparing of Old painted surfaces of wood of any description not otherwise described over 10 cm width or grith and applying one coats of synthetic enamel paint complete all as specified and directed.
Dismantling of plain or corrugated AC sheeting, any gauge, thickness, including ridge etc as in roof covering complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping, bed plates benching etc slightly rounded or chamfered angles and throating, complete all as specified and directed.
Material and labour for Roof trusses (framed), purlins, rails and heavy bracket frame (beam, tee, angle, channel or flat section) including distance pieces, cleats etc Gde Fe-410-S, complete all as specified and directed.
Material and labour for Rolled mild steel plates (plain or chequered), square cut or notched (ordinary or counter sunk) forming holes etc of Gde Fe-410-S ccomplete all as specified and directed.
Material and labour for MS work in tubular trusses or rectangular hollow section including special shaped washer etc. Complete using ERW or induction butt welded tubes confirming to IS-1239 (Part I-1990). As in sun shade to window/door etc complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating Gl based corrugated steel 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminium zonc Gl based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fixing Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured variant E-board (classic), ISI marked, conforming to IS: 14982-2000 over and including Gl snap grid frame work for false ceiling, grid size 605mm x605 mm with Gl angle of size 24mmx24mm, main runner ‘T’ of size 24mmx38mm, secondary runner ‘T’ of size 24mmx28mm with 4mm Gl wire with butterly clips as hangers of levelling, fastners, supports, plugs to walls/joists etc all as per manufacture’s Instructions, including making holes, cutting chasis and Making good exsting walls in cement mortar 1:3or PCC 1:2:4 type B1, including dismantling of old/decayed wall / ceiling boards any thickness of any description including cover fillets complete all als specified and directed. Note :- All steel members shall be hot dipped galvanised with zinc coating not less than 120gm/sqm.
Disconnecting existing PVC tanks, setting aside (or lowering if required ) for repair, cleaning and removing all scale and dirt by using bleaching power from tank and from mouth of circulating pipes etc and hosting if required reconnecting and refixing in position of capacity 500 ltrs but not exceeding 100ltrs and making good for running of water from tank to inside of bldgs and letter writing of date of cleaning and due on of synthetic enamel paint, complete all as specified and directed. Note : Bleaching powder and like shall be included in this items.
Material and labour 25 mm thick (average thickness) PCC 1:2:4, type B-0 using 12.5mm graded stone aggregates as in floor by maintain required gradient/undulation, finshed even and fair as in roof padding including preparation of surface and mix with water proofing compound and finished even and fair without using extra cement, complete all as specified and directed. ( Note : WPC will measured and paid separately as supply only.)
Complete removal of the existing roof treatment any nos of layers taken out membrane, PCC padding/roof, tiles tec including grabbing up of tree roots, roughing and preparation surfaces of old concrete floor by picking, scrubbing down with steel brushes, sweeping, cleaning and washing down with water to remove dust etc. And applying the following Roof treatment, complete all as specified and directed. Applying 1st course of 15mm thick screed bed with cement mortar 1:4 over old concrete surface Applying 2nd course of bituminous primer @ 0.4 kg/Square Metre conforming to IS-3384 over screed bed. Applying 3rd course of a coat of bonding maternal with blown type bitumen of grade 85/25 heating to working temperature of 180centigrade and applied @ 1.5 kg/Square Metre. Applying 4th course of APP (Atactic Polypropylene) 3mm thick, weight not less than 3.6 kg/Square Meter with 160 Grams/Square Metre non woven polyester made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane shall be laid with LPG torch and overlap sealed and finished neat Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature 180centigrade and applied @ 1.2 kg/Square Metre. Applying a coat of bituminous based aluminium paint as finished coat.
Material and labour TMT bars (Fe-500),10mm dia and over in reinforcement cut to length , bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with ande incl mild steel wire (annealed) not less than 0.96mm dia or securing with clips, complete all as specified and directed.
Supply and fixing Precast reinforced cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in cover slab set in CM 1:6, complete all as specified and directed. Note : (Reinforcement shall be measured and paid separately.)
Material and labour for writing letters or figures (block, Roman, Italic or Indian) exceeding 15 centimetre high etc with synthetic enamel paint including necessary scaffolding up to four storeys height of blds if required, Shade/colour shall be approved by GE, all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt, complete all as specified and directed.
Material and labour for Stops, commas, short lines, dashes, hyphens, brackets, etc including necessary scaffolding up[ to four storeys height of blds if required, Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt, complete all as specified and directed.
Cleaning/clearing of sewage line (including manholes) 100mm to 150mm bore of any description, underground at any depth, removing any type of blockage including descaling, & dechocking of drains as well as manholes and depositing the sludtge in a pit (including digging of pit) not less than 100 metres away from the site of cleaning and covering the sludge with layer of 2.5cm thick layer of earth and spraying unslacked lime on the pit and make line smooth functional, complete all as specified and directed.
Cleaning of blocked WC/floor trap/gully trap etc. Including and upto first manhole manually and well flushing with clear water, making the seat functional including deposing the sludge in pit (including digging of pit) not less than 100 metre away from site of cleaning and covering the deposited sludge with minimum 25cm thick layer of earth and spreading unslacked lime on the pit, complete all as specified and directed.
Taking out carefully copper / aluminium point wiring ( light, fan, socket or power ) complete with all fittings, fixtures such as switch socket out let, ceiling rose, holder, regulator, DBs etc including making good the disturbed surface of wall/floors, complete all as specified and as directed by Engineer-in-Charge.
Taking down distribution boards / wooden board, switch fuse units, steel enclosures for MCB of any type and removing from site, complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable sub main wiring any size and making good the disturbed surface, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring for one light controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi – stranded copper (FRLS) cable 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi – stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes, readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick Bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 161 above but for one fan point controlled by one piano switch, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 161 above but for one bell point controlled by one bell push, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 161 herein before for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 161 here-in-before but for one 3 pin socket outlet 5 Amp independent board.
All as per item No. 161 here-in-before but for one 15 Amp 3 pin switch socket outlet, independent board with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 Sqmm continuous PVC insulated unsheathed single core multi – stranded copper conductor (FRLS) cable for earth continuity wire , complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs of switch piano flush type single pole, one way 5 Amp, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs of switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed at site by the Engrs-in-Charge.
Supply and fix in repairs of switch socket out let combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed at site by the Engrs-in-Charge.
Supply and fix in repairs of ceiling rose surface Bakelite three terminals 240 volts , complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs lamp holder PVC case body of Bakelite with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Electronic fan regulator stepped type, two module with five step 240 volts, 100 Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, all as directed by Engineer-in-Charge.
Supply and fix replacement of bell push flush type piano 5 Amp, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement bell multi music 230 volt, AC single pole, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of Tube light fitting integrated type suitable for LED 20W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 230/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of Tube light fitting integrated type suitable for LED 10W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 32/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs factory made epoxy powder coated distribution board TPN 6 ways, 415 volts with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one TPN-MCB as incomer and SP MCBs outgoing , complete all as specified and as directed by Engineer-in-Charge and confirming to IS: 8623
Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing , complete all as specified and as directed by Engineer-in-Charge and confirming to IS : 8623.
Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 4 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing, complete all as specified and as directed by Engineer-in-Charge and confirming to IS:8623.
Supply and fix in replacement MCB SP-06 to 32 Amp, 10 KA, B Curve, 240 Volts , complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of MCB SPN 16 Amp,10 KA, B Curve, 240 volts 50Hz AC supply, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of MCB SPN 32 Amp, 10 KA, B Curve, 240 volts 50 Hz AC supply, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair MCB FP 63 Amps 240 Volts, 10 KA, B Curve, 240 volts 50 Hz AC supply, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sub main wiring with two single core PVC insulated (Unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (Unsheathed) solid copper conductor FRLS cable of size 6 sqmm as in continous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface, complete all as specified and as directed by Engineer-in-Charge.
M&L in repair for earthing complete with galvanized steel earth plate 600mmx600mmx6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1 (using 20mm dia stone aggregate) reinforced with 6mm dia round bar @75 mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No. 3 in page No. 497 of SSR Part-I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion, including testing , complete all as specified and as directed by Engineer-in-Charge.
Exhaust fan metallic body, 300mm (12’’) sweep, single phase, 230 volts 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminium rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall, plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site , complete all as specified and as directed by Engineer-in-Charge.
Exhaust fan PVC body, 250mm (10”) sweep, single phase, 230 volts 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminium rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall, plastering, necessary brick work and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site, complete all as specified and as directed by Engineer-in-Charge.
Taking down electric energy meter single phase any size or type from the existing site and refixing the same at same place after carrying out necessary repair work and making the surface good to match with existing surface, complete all as specified and as directed by Engineer-in-Charge.
Supply install testing and commission of 1200 mm sweep 230 Volts AC ceiling fan, BLDC 5 star rating confirming to IS 374:2019, 3 blade along with copper wound stator, with minimum air delivery 215 cubic metre per minute power input 50 watt, aluminium blades, capacitor, down rod, canopy etc as required including making connection with three core 1.5 sqmm flexible copper cable upto ceiling rose complete including taking down old unserviceable ceiling fax and deposited to MES store yard, complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan 1200 mm sweep complete cleaning the grease oil etc spray painting with 2 coats of synthetic emamelled paint over a coat of primer including replacement of bearing, capacitor, cotton pin, rubber coal, MS nuts bolts washer, connector prewired from connector from connector to ceiling rose with twin core flexible copper conductor cable 24/0.02 re fixing in position connecting testing etc, complete all as specified and as directed by Engineer-in-Charge.
Supply, install and testing water heater storage type (Geyser) single phase 230 V, 50H, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000 Watt rated power, incoloy 800 glass coated heating element, inner tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8 MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners -04 nos, hot & cold water metallic flexible pipes 15mm bore of adequate length as provided by OEM or required at site – 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard, complete all as specified and as directed by Engineer-in-Charge.
Cutting existing steel tubing 15mm bore for alterations or additions (Each cut measured), complete all as specified and as directed by Engineer-in-Charge.
Screwing existing steel tubing 15mm for alterations or additions, complete all as specified and as directed by Engineer-in-Charge.
S&F tubes medium grade galvanized 15mm bore with and including all fittings such as bends, elbows, tees, short pieces, connectors, bolts, nuts, diminishing pieces, caps, plugs, unions etc and fixed complete to wall & ceilings or laid in floors, complete all as specified and as directed by Engineer-in-Charge.
S&F 15mm bore bib taps (long body) cast copper alloy, fancy type, chromium plated with fancy knob, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and as directed by Engineer-in-Charge.
S&F fancy type chromium plated stop valve screwed down high pressure with fancy knob with long shank and cup, screwed both ends for 15mm bore dia pipes and fittings or for unions, complete all as specified and as directed by Engineer-in-Charge.
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 976850.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ARUN ANAND
M/s Khajuria Construction Co.
M/s Ravinder Kapoor Engineers and Builders
TRIVENI CONSTRUCTIONS
DES RAJ NAGPAL CONTRACTORS PVT.LTD
BANKE BEHARI GANDOTRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .