Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹27.2 L+₹70,742.71 (2.67%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹32.1 L+₹5.6 L (21.2%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹34.7 L+₹8.2 L (30.9%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹34.8 L+₹8.3 L (31.4%)Rejected-Finance 11 753 1 HABIBULLA STREET KADAPA CUDDAPAH ANDHRA PRADESH 516001 | Y S R | ANDHRA PRADESH | 516001 | L5 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | Tejas Enterprises L4 | Sneha Aircool L6 | Monarch Sales Corporation L8 | KESARI AND SONS L3 | Deccan Enterprises L5 | ECOBUILD L1 | Adinath Technical Services L7 | Mepcon Projects Pvt LTd L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out Relaying / Rerouting of serviceable XLPE LT UG cable of following sizes including disconnection from LT Panel/Pole/FP etc and reconnection after re-laying work to LT Panel/Feeder Pillar /MDB according to existing system with suitable size of AL Lugs, nut-bolts & washers etc and fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 400 Sqmm complete all as specified and directed.
Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A. | 30 | RM | 60 ₹1,800 | 60 ₹1,800 | 9 ₹270 | 15 ₹450 | 18 ₹540 | 5 ₹150 Lowest | 18 ₹540 | 15 ₹450 |
| 2.00 | Ditto all as per item No 1 above but 3.5 Core 300 Sqmm | 50 | RM | 60 ₹3,000 | 60 ₹3,000 | 9 ₹450 | 15 ₹750 | 18 ₹900 | 5 ₹250 Lowest | 18 ₹900 | 15 ₹750 |
| 3.00 | Ditto all as per item No 1 above but 3.5 Core 240 Sqmm | 40 | RM | 60 ₹2,400 | 60 ₹2,400 | 9 ₹360 | 15 ₹600 | 16 ₹640 | 5 ₹200 Lowest | 18 ₹720 | 15 ₹600 |
| 4.00 | Ditto all as per item No 1 above but 3.5 Core 185 Sqmm | 50 | RM | 60 ₹3,000 | 60 ₹3,000 | 9 ₹450 | 15 ₹750 | 16 ₹800 | 5 ₹250 Lowest | 18 ₹900 | 15 ₹750 |
| 5.00 | Ditto all as per item No 1 above but 3.5 Core 150 Sqmm | 70 | RM | 60 ₹4,200 | 60 ₹4,200 | 9 ₹630 | 15 ₹1,050 | 16 ₹1,120 | 5 ₹350 Lowest | 17 ₹1,190 | 15 ₹1,050 |
| 6.00 | Ditto all as per item No 1 above but 3.5 Core 120 Sqmm | 50 | RM | 45 ₹2,250 | 60 ₹3,000 | 9 ₹450 | 15 ₹750 | 15 ₹750 | 5 ₹250 Lowest | 17 ₹850 | 15 ₹750 |
| 7.00 | Ditto all as per item No 1 above but 3.5 Core 95 Sqmm | 70 | RM | 45 ₹3,150 | 50 ₹3,500 | 9 ₹630 | 9 ₹630 | 15 ₹1,050 | 5 ₹350 Lowest | 17 ₹1,190 | 15 ₹1,050 |
| 8.00 | Ditto all as per item No 1 above but 3.5 Core 70 Sqmm | 80 | RM | 45 ₹3,600 | 50 ₹4,000 | 8 ₹640 | 9 ₹720 | 14 ₹1,120 | 5 ₹400 Lowest | 17 ₹1,360 | 12 ₹960 |
| 9.00 | Ditto all as per item No 1 above but 3.5 Core 50 Sqmm | 100 | RM | 40 ₹4,000 | 50 ₹5,000 | 8 ₹800 | 9 ₹900 | 14 ₹1,400 | 5 ₹500 Lowest | 16 ₹1,600 | 12 ₹1,200 |
| 10.00 | Ditto all as per item No 1 above but 3.5 Core 35 Sqmm | 130 | RM | 40 ₹5,200 | 50 ₹6,500 | 8 ₹1,040 | 9 ₹1,170 | 14 ₹1,820 | 5 ₹650 Lowest | 16 ₹2,080 | 10 ₹1,300 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Khadakwasla
GE Khadakwasla
REPAIR/ REPLACEMENT OF LT UG CABLES WITH CONNECTED ACCESSORIES IN ATT, MH , SQN AREA IN ZONE B ADMINISTRATIVE BUILDING AT NDA KHADAKWASLA
2025_MES_721021_1
8968/E8
Open Tender
Civil Works
Item Rate
180 days
GE Khadakwasla
As per tender documents
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹70,000
Yes
30 Sept 2025
17 Jul 2025
7 Aug 2025
17 Jul 2025
5 Aug 2025
31 Jul 2025
17 Jul 2025 - 31 Jul 2025
Amount
Taking out Relaying / Rerouting of serviceable XLPE LT UG cable of following sizes including disconnection from LT Panel/Pole/FP etc and reconnection after re-laying work to LT Panel/Feeder Pillar /MDB according to existing system with suitable size of AL Lugs, nut-bolts & washers etc and fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 400 Sqmm complete all as specified and directed. Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A.
Ditto all as per item No 1 above but 3.5 Core 300 Sqmm
Ditto all as per item No 1 above but 3.5 Core 240 Sqmm
Ditto all as per item No 1 above but 3.5 Core 185 Sqmm
Ditto all as per item No 1 above but 3.5 Core 150 Sqmm
Ditto all as per item No 1 above but 3.5 Core 120 Sqmm
Ditto all as per item No 1 above but 3.5 Core 95 Sqmm
Ditto all as per item No 1 above but 3.5 Core 70 Sqmm
Ditto all as per item No 1 above but 3.5 Core 50 Sqmm
Ditto all as per item No 1 above but 3.5 Core 35 Sqmm
Ditto all as per item No 1 above but 3.5 Core 25 Sqmm
Ditto all as per item No 1 above but 4 Core 16 Sqmm
Ditto all as per item No 1 above but 4 Core 06 Sqmm
Supply and laying in replacement including testing and commissionnig of LT UG Cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip armoured with multi stranded aluminum conductor, ISI marked, heavy duty including disconnection from LT Panel/Feeder Pillar/Pole etc and reconnection after laying work to same LT Panel/Feeder Pillar /Pole according to existing system with suitable size of AL Lugs, nut-bolts & washers etc including cables laid in trenches/ducts/under plinth floors/ passing through pipes etc or fixed on any type of wall with suitable size of GI saddles etc complete of size 3.5 Core 400 Sqmm complete all as specified and directed. Note - Excavation / earthwork, cable protection pipe & sand cushioning will be measured and paid separately under respective item of sch A.
Ditto all as per item No 14 above but 3.5 Core 300 Sqmm
Ditto all as per item No 14 above but 3.5 Core 240 Sqmm
Ditto all as per item No 14 above but3.5 Core 185 Sqmm
Ditto all as per item No 14 above but 3.5 Core 150 Sqmm
Ditto all as per item No 14 above but 3.5 Core 120 Sqmm
Ditto all as per item No 14 above but 3.5 Core 95 Sqmm
Ditto all as per item No 14 above but 3.5 Core 70 Sqmm
Ditto all as per item No 14 above but 3.5 Core 50 Sqmm
Ditto all as per item No 14 above but 3.5 Core 35 Sqmm
Ditto all as per item No 14 above but 3.5 Core 25 Sqmm
Ditto all as per item No 14 above but 4 Core 16 Sqmm
Ditto all as per item No 14 above but 4 Core 6 Sqmm
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in hard/dense soil for foundation of pole, stay, laying of cable and pipe etc as complete all as specified and directed.
Ditto all as per item No 27 above but in soft / disintegrated Rock
Returning and filling, including spreading levelling and well ramming in layers n exc 25 cm complete all as specified and directed.
Removing excavated material to a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M&L for dry crush sand cushioning to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed. Note : For measurement purpose, punned thickness shall be considered.
Supply and laying in replacement of burnt clay fly ash building bricks, designation 75 (Kg/Sqcm), laid in right angle along the cable for protection of cable, complete all as specified and directed.
S&F in replacement of GI pipe Light grade 50 mm bore dia ISI marked with all fittings laid in trenches and fixed pole by flat iron clamps, nut,bolt,washers suitable size complete required for protection/ support of under ground cable complete all as specified and directed.
Supply and laying 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 06 to 16 Sqmm 3.5 core complete all as specified and directed
Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and directed
Supply and laying 63 x 50 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 50 Sqmm 3.5 core complete all as specified and directed .
Supply and laying 77 x 63 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 70 Sqmm 3.5 core complete all as specified and directed
Supply and laying 90 x 75 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 95 Sqmm 3.5 core complete all as specified and directed
Supply and laying 110 x 95 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 120 to 150 Sqmm 3.5 core complete all as specified and directed
Supply and laying 120 x 103 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 185 to 240 Sqmm 3.5 core complete all as specified and directed
Supply and laying 160 x 135 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 300 to 400 Sqmm 3.5 core complete all as specified and directed
Supply and laying in replacement G.I pipe light grade pipe 100 mm dia with all fittings required for protection of under ground cable complete all as specified and as directed.
M&L for road cutting through existing bituminous road as required for laying pipe/cable etc and make good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC (1:2:4) type B1 and bitumin complete all as specified and as directed
M & L for Straight Through Jointing Kit Heat Shrink type suitable for 1.1 KV LT XLPE armoured aluminium stranded conductor Cable Outdoor type complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of jointing work complete all as specified and directed of following sizes :- 3.5 Core 400 Sqmm
Ditto all as per item No 44 above but 3.5 Core 300 Sqmm
Ditto all as per item No 44 above but 3.5 Core 240 Sqmm
Ditto all as per item No 44 above but 3.5 Core 185 Sqmm
Ditto all as per item No 44 above but 3.5 Core 150 Sqmm
Ditto all as per item No 44 above but 3.5 Core 120 Sqmm
Ditto all as per item No 44 above but 3.5 Core 95 Sqmm
Ditto all as per item No 44 above but 3.5 Core 70 Sqmm
Ditto all as per item No 44 above but 3.5 Core 50 Sqmm
Ditto all as per item No 44 above but 3.5 Core 35 Sqmm
Ditto all as per item No 44 above but 3.5 Core 25 Sqmm
Ditto all as per item No 44 above but 4 Core 16 Sqmm
Ditto all as per item No 44 above but 4 Core 6 Sqmm
S & F in replacement of MCB, 4P, 415 V, 63 Amp, 10 kA, C-Curve, suitable to fit existing sheet metal enclosure/Sub MDB complete all as specified and directed.
M&L for PCC / Interlocking Tiles Path Way cutting of size (45x45) cm as required for laying pipe/cable etc and making good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC 1:2:4 type B1 complete all as specified and as directed .
M & L for Fixing of LT UG Cable on wall/ under duct with suitable size of saddles, screws and connected accessories complete all as specified and directed.
Supply & Fix in replacement of including commissioning and installation of digital automatic timer switch distribution panel board, factory assembled in powder coated steel sheet enclosure, comprising of 4P MCB, 40 Amps & 3 Pole power contactor 40/50 Amps and 230V digital time switch for controlling LED street lights, including earth work for fixing Timer switch distribution panel board and shall be provided 4 Nos 20x20x3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (Using 20mm graded coarse aggregate) for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary formwork complete all as specified and directed.
M & L for demolition of unreinforced PCC, floors, foundation etc in any position and any description including removal of demolished material complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium 6 Sqmm stranded conductor, Twin core cable flat served with inner sheathing of PVC tape and overall PVC sheathed in service connections including taking down existing one complete all as specified and directed.
Supply & Fix in replacement of SMC Junction box on pole/ wall, dimensions (270 x 225 x 135)mm (LxBxD), 3 phase 4 wire system, including cable connecting base, with mounting SS railing, Cable lugs suitable to 35 Sqmm 3.5 core cable, connection for incoming and outgoing cables including Fixing arrangement on wall/ pole etc complete all as specified and directed
M&L for LT UG Cable fault finding/testing from FP Box to fault location including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of fault finding/testing work complete all as specified and directed of size 3.5 Core 300 to 400 Sqmm complete all as specified and directed. Note:- Job will be measured after fault detection of any type regarding this decision shall be final & binding.
Ditto all as per item No 65 above but 3.5 Core 120 to 240 Sqmm
Ditto all as per item No 65 above but 3.5 Core 35 to 95 Sqmm
Ditto all as per item No 65 above but 3.5/4 Core 6 to 25 Sqmm
Labour for disconnecting the LT UG Cable (approx 10-12 No of Cables) of any size from LT ACB breaker and setting aside at safe place/side by taking proper shut down for human saftey, cleaning the duct/trench by removing foreign material/mud from trench/duct including reconnecting the all LT UG Cables according to existing system complete all as specified and directed
S & F in replacement of Wire mesh Cable Tray Hot Dipped Galvanized size 54 X 100mm, Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537, Wire cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer including all standard wall mounting accessories e.g. SS Mounting Bracket, bends, Fastners, kitastar, nut, bolts and washers etc complete all as specified and directed. It shall be manufactured with a longitudinal 'T- welded' safety edge complete all as specified and directed.
M & L in replacement for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones of Post Office RED Colour and fixed on LT Poles with M.S. clamps, bolts and nuts of required size, for 440 Volts LT of size 200 X 150mm complete including taking down existing one complete all as specified and directed.
M & L for route tracing of LT UG cables under ground/road from one end to another end of cable, size upto 400 sqmm including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/ MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of route tracing work complete all as specified and directed.
S & F in replacement of Wire mesh Cable Tray Hot Dipped Galvanized size 54 X 300mm, Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the atandard IEC 61537, Wire cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer including all standard wall mounting accessories e.g. SS Mounting Bracket, bends, Fastners, kitastar, nut, bolts and washers etc complete all as specified and directed. It shall be manufactured with a longitudinal 'T- welded' safety edge complete all as specified and directed.
Supply & Fix in replacement of Cable Route Marker made up of Cast Iron of dia 80 mm and thickness 4.65 mm with supporting angle iron of size 20 x 20 x 3 mm and height 0.6 mtr for stand including priming, painting and wirting of "LT UG CABLE" in suitable size of letter including necessary earthwork and grouted at suitable depth in PCC 1:3:6 Type C2 using 40 mm graded aggregate in mass concrete complete all as specified and directed.
Mepcon Projects Pvt LTd (BID ID -3383433)
KESARI AND SONS (BID ID -3383519)
Tejas Enterprises (BID ID -3382534)
Deccan Enterprises (BID ID -3383522)
Sneha Aircool (BID ID -3382597)
Adinath Technical Services (BID ID -3383385)
Monarch Sales Corporation (BID ID -3383168)
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .