Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.4 LAccepted-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹65.3 L+₹90,512 (1.41%)Rejected-AOC C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹70.8 L+₹6.4 L (9.93%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹71.1 L+₹6.8 L (10.5%)Rejected-AOC NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹72.3 L+₹7.9 L (12.3%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹70.7 L
EMD Value
₹1.3 L
Closing Date
5 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO P-65 AND P-88 (OR MD ACCN) AT FOD UNDER GE (S) UDHAMPUR
2021_MES_424940_1
CWE/U(S)-103/2020-21
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (SOUTH) UDHAMPUR
₹1.3 L
Yes
29 May 2021
23 Feb 2021
7 Apr 2021
23 Feb 2021
5 Apr 2021
23 Mar 2021
60 days
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for such as existing roof padding incl plaster etc. on roof , complete all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match,over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match including screed bed or bedding layer of mortar 10mm thick in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 600x300mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Marble work Green 20 mm thick (table rubbed and polished, moulding ) in steps, jambs,pillars, window cills, cooking platforms and like in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade other than black and white (Shade-Green) over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layers (10+5mm) on fair faces of brick /concrete including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and fair without using extra cement including mixing interal water proofing compund in the proprotion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ), complete all as specified and directed by Engineer-in Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer and filling frame with PCC 1:3:6 type C-0, complete all as specified and as directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
30 mm thick flush shutters, solid core construction, with block board core and plywood face pannels and one face is covered with decorative face veneer with liping/frame to match, complete all as specified and directed by Engineer-in charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/15 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item No 25 here in before but without glazing bar complete all as specified and as directed. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Factory made mild steel ventilators (box type) with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified (without frame but frame to be made along with door). Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) for hold fast complete all as specified and as directed by Engr-in-harge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
75mm butt hinges ,medium weight ,cold rolled mild steel all as complete all as specified and directed.
18/19 mm thick block boards grade 2 quality enterior grade, Commercial type fixed with screw or Steel fram/Timber frame incl teak wood lipping,6mm thick fixed with Nail complete all as specified and directed.
0.9 mm thick decorative laminate type -1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructuions all as specified and directed.
100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified.
40 mm dia cupboard knobs fixed with nut, screw and washer of mild steel bright finish complete all as specified.
Ball catches with 8mm dia steel balls and brass body and striking plate including letting in and fixed complete all as specified and as directed.
Mild steel, 150 mm, ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified.
Door eye,Round/Square,tringle,antque Gold R-309 complete, all as specified. (ISI Mark)
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) , over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge. complete all as specified.
Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 15 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished rough for receiving tiles, complete all as specified and as directed by Engr-in-Charge. complete all as specified.
150mm wide strip of makrana white marble 18-20 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing , over and including 20 mm thick screed bed or bedding layer in cement mortar 1:3 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge. complete all as specified. complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 43 above but except brick.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed by Engr-in- Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
4 mm thick sheet glass , ordinary quality and glazing with oil putty or wooden beads not exc 0.50 Sqm in each pane complete all as specified and as directed.
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1mm and fixed with ist class wooden beadingor tinned tacks or galvanised wire staple complete all as specified .
250 mm long aluminium alloy, anodised, sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed by Engr-in-Charge.
Mild steel cold rolled butt hinges medium weight 100 mm log fixed to steel /angle iron frame by welding, if required complete all as specified.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
100mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
Aluminium drapory rods of 25 mm dia decorative type with wooden finish alongwith holding for brakets & end caps fix in repairs complete all as specified.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash basin, white, flat back, size 550x400mm excluding tap, chain, plug but including brackets, waste fitting 32mm dia ,brass chromimium plated for glazed ware sink, basin,with pedestal, long screwed shanks and fly nuts flange end bedded in red lead cement and other end, fix in repair, complete all as specified.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed by Engr-in-Charge.
Preparing plastered or unplastered new surfaces of ceiling and applying two coats of white wash, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
Supply only flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern, complete all as specified and as directed by Engr-in-Charge.
Stainless steel grating doom 75/100mm dia square or round, complete all as specified and as directed by Engr-in-Charge.
Aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs. complete all as specified in repairs. (ISI Mark)
PVC connections 15 mm size with PTMT nuts of length 450 mm and washers, complete all as specified and as directed by Engr-in-Charge.
Steel peg set colour coated of six as per sample in repairs complete all as specified.
Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Plate rack made of stainless stee, 600 x 750X0.55mm including fixing as per manufacturers instruction complete all as specified.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to walls duly applying a coat of bituminous black paint all as specified of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to walls duly applying a coat of bituminous black paint all as specified of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to walls duly applying a coat of bituminous black paint all as specified of 50mm bore, complete all as specified and as directed by Engr-in-Charge.
Salt-glazed stoneware gully traps, size 150 x 150 mm, square or round mouthed, type 'P', including setting and jointing to drains with cement mortar 1:1, fixed in repairs, including demolition of old unserviceable gully traps complete all as specified (ISI Marks).
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 75mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed.
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 100mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark)
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed.
50mm Cast iron cowls as in repairs complete all as specified and as directed.
Cast iron Reducer 100mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed.
Cast iron Reducer 75mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed.
Taking down eaves gutters and and rain water pipes (any size or pattern ), including all fittings incl removal of store and sold to contractor through credit.
110 mm bore PVC SWR bends and fixed with joint sealent etc complete all specified and as Directed
110mm PVC (SWR) pipes single/Double socketed of any length with rubber ring joints pressure rating 4 kg/Sqcm fixed to wall incl clamp etc complete all as specifiedand as directed.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 50 mm bore of pipe complete all as specified and as directed.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 75 mm bore of pipe complete all as specified and as directed.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 100mm bore of pipe complete all as specified and as directed.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as in sunken floor/ foundatiom, complete all as specified and as directed by Engr-in-Charge.
Taking down 15mm Bore steel tubing and connections including all fittings and removing to store.
Taking up or down 20mm bore steel tubing and connections including all fittings and removing to store.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed concealed to walls and or laid under floors etc complete all as specified.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed concealed to walls and or laid under floors etc complete all as specified.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm fixing in repair.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm fixing in repair , all as specified.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Bib taps long body, cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge..
Shower rose 75mm size brass CP with or without swivel joints suitable for 15mm bore tubing, fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), including dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Stop cock, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm fixing in repair , all as specified.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 15 mm bore, complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 20 mm bore, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
Machine pressed / vibro mechenically floated interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement mix with pigment. laid over and including 25 - 30mm thick sand cushioning bed including spreading levelling watering if required, complete all as specified and as directed by Engr-in-Charge. Shape shall be approved by Engr-in-Charge.
Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in quoin blocks (for use with masonry/ kerbs), bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair aces, including chamfers, weatherings, throating etc. and setting in mortar 1:4, complete with joints to match, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Reinforced concrete pipes 200mm bore ,class NP2, laid and jointed complete with coller all as specified and as directed.
Precast RCC 1:2:4 type B-1, using 20mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4 complete all as specified.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains including necessary form work, complete all as specified and as directed by Engr-in-charge.
Extra for forming fair finished drain or channel exc 30cm inner girth in cement concrete ,using extra cement ,incl forms moulds ,mitered/stopped ends etccomplete all as specified and as directed by Engr-in-Charge.
Welded steel wire fabric mesh weight not exceeding 4 Kgs per sqm fixed to wood or steel members complete all as specified and directed.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / fan/ exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc, fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 126 here-in-before but one 3/5 pin 5 Amp socket outlet on independent board , complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 126 here-in-before but one 3/5 pin 5 Amp socket outlet on the same board with other switches., complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 126 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 126 here-in-before butt for light point controlled by 2-two way switch
Switch piano flush button single pole one way 5/6 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 3 pin 5 Amp 240 Volts complete all as specified and as directed.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch piano type 5 Amps single pole two way 240 volts complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Bell push 6 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA "B" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps,240 Volts, rupturing capacity 10 KA "B" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCB TPN, 4-pole ,63 Amps, 415 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
E-lite LED curve luminaire, 20 watt with wide angle profile, and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
E-lite LED curve luminaire, 10 watt with wide angle profile, and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
E-lite LED curve luminaire, 5 watt with wide angle profile, and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing Energy saving and environmental friendly long life LED street light, 30 watt, 5700K, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 including all accessories complete all as specified and as directed by Engineer-in-Charge.
Note for srl item no 145 to 148 : (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
Taking down ceiling/exhaust fan and cable etc. and refixing/hanging the same after repair/replacement of damaged/worn out parts like canopy 02 Nos, down rod, clamps with nuts, bolts and washers, rubber bush, greasing, oiling and provn of cable from ceiling rose to fan, etc. including painting with two coats of synthetic enamel white paint and writting Ser No/Mes No with black paint complete, all as specified.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked (concealed/surface) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 152 Contd … (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 4 core including taking down existing cable ,complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
M/S ASHOK KUMAR PACHIALA
R K BUILDERS
M/s Khajuria Construction Co.
paras ram pachiala
jyoti parkash sharma
M/S Inderjit Sharma and Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .