Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹11.9 L+₹1.8 L (17.7%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹12.3 L+₹2.1 L (21.0%)Rejected-Finance 32 06 PEST HOUSE NARONA CHAURAHA MALL ROAD POST BOX NO 49 KANPUR 208001 UP | KANPUR | KANPUR | UP | 208001 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹12.8 L+₹2.7 L (26.4%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹16.2 L+₹6.1 L (59.9%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
22 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
ADDITION ALTERATION TO POWER SUPPLY DISTRIBUTION SYSTEM AT AGV COMPLEX AT AFS CHAKERI KANPUR
2020_MES_355395_1
8410/E8
Open Tender
Civil Works
Item Rate
182 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹30,000
7 Sept 2020
24 Jun 2020
25 Jul 2020
24 Jun 2020
22 Jul 2020
8 Jul 2020
60 days
Amount
Excavation in trenches in soft/ loose soil n exc 1.5 m wide and n exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/ stay assembly and laying/ taking out cables complete all as specified and directed.
Returning , filling trenches including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc 50 Mtr and depositing where directed at a level n.exc. 1.50 Mtr above the starting point complete all as specified and directed.
M & L for Sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) complete all as specified and directed. NOTE: Punned thickness only will be considered for payment.
M & L for provision of bricks for protection cover to under ground cable (with old size sub class 'B' bricks ) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width & not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e. bitumen/ PCC (1:3:6) type C-1 complete all as specified and directed .
M & L for re-routing of LT cables off size from 16 Sqmm to 35 sqmm, 3.5/4 core including taking down in ducts /wall / floor/roof /trenches etc and re-alignment of LT cable, cutting/ chasing in wall/ duct and re-fixing in concealed position as per site requirement incluidng replacement of lugs, nut, bolts, washers, saddle clamp etc. including making good the disturbed surface to match with the existing surface complete all as specified and directed .
Supply, Laying , jointing, testing and commissioning LT XLPE / PVC cables, PVC insulated, PVC sheathed armoured LT 1100 volts grades heavy duty with aluminum stranded conductor through pipes, induct, on poles, in trenches etc complete all as specified and directed for following size. Make:- Havells /Asian, Polycab/Universal, / Finolex NOTE: The rate of termination and connecting of cable including providing suitable size and Nos of lugs by crimping as directed shall be deemed to be included in the item rate. 95 Sqmm 3.5 core
All as per item No 8 but for 25 sqmm, 4 core
M & L for making horzontal boring in any type of soil under road 60 cm below the top surface of road by converntional method without distrubing outer earth surface complete for passing through 40 mm to 80 mm dia GI pipe and filling earth after alying of pipe including disposal of surplus soil complete all as specified and directed. NOTE: Pipe will be measured and paid separately. Any damage to existing cables/ road of ay tyupe will made good by the tenderer without any extra payment.
Supply and fixing / laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ wall /floor/under road crossing etc complete all as specified and directed for following size:- 80 mm bore
All as per item No 11 but for 50 mm bore.
Supply, install, testing and commissioning, factory made (CPRI approved) LT feeder pillar box indoor type, IP-54 protection, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bars 600 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2.0mm thick CRCA MS sheet with support of angle iron of size 50 x 50 x 5mm to cover all corner and standing legs (min. 45cm) of angle iron work, duly powder coated finish. Front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate with bone & skull complete all as specified and directed. The scope of work includes provision of the following :- Make of MCCB & acessories :- Havells, Legrand, ABB. Incoming :- (a) MCCB 250 amps, 4 pole, 36 KA (Ics = 100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 01 No (b) Bus bar (Aluminium strip) 600Amp, 4 pole, not less than 30cm long mounted on insulators for incomming supply - 01 No. (c) Multifunctional meter with 3 lines LCD display of voltage, current, frequency and power factor with suitable ratio CT complete. - 01 set. (d) LED type Neon indicating lamps (R, Y & B) -01 Set. Outgoing :- (a) MCCB 100 amps, 4 pole, 25 KA (Ics =100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 07 Nos. (a) MCCB 63 amps, 4 pole, 25 KA (Ics =100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 02 Nos.
Supply, install, testing and commissioning, factory made (CPRI approved) LT feeder pillar box indoor type, IP-54 protection, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bars 600 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2.0mm thick CRCA MS sheet with support of angle iron of size 50 x 50 x 5mm to cover all corner and standing legs (min. 45cm) of angle iron work, duly powder coated finish. Front & rear opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate with bone & skull complete all as specified and directed. The scope of work includes provision of the following :- Make of MCCB & acessories :- Havells, Legrand, ABB. Incoming :- (a) MCCB 250 amps, 4 pole, 36 KA (Ics = 100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 01 No. (b) Bus bar (Aluminium strip) 600Amp, 4 pole, not less than 30cm long mounted on insulators for incomming supply - 01 No. (c) Multifunctional meter with 3 lines LCD display of voltage, current, frequency and power factor with suitable ratio CT complete. - 01 set. (d) LED type Neon indicating lamps (R, Y & B) -01 Set. Outgoing :- (a) MCCB 100 amps, 4 pole, 25 KA (Ics =100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 04 Nos. (b) MCCB 63 amps, 4 pole, 25 KA (Ics =100% Icu), with adjustable thermal & adjustable magnetic setting, 50 Hz, 415 volts grade - 02 Nos.
Note for item No. 13 & 14 : (i) All panel shall have platform with PCC (1:4:8) type D-2 using 40mm graded stone crushed stone aggregate 15cm thick in foundation, bricks, masonry in CM (1:6) and 15mm thick rendering in CM (1:6) on exposed surfaces and 100mm thick PCC padding (1:3:6) type C-1 on top and grouting bolts etc for panel. The platform shall be 45cm height from the nearest ground level complete. (ii) All incoming MCCB shall be connected through MCCB spreaders with incoming busbar and incoming cable shall be connected with incoming bus bar. (iii) Drawing shall be got approved well in advance before febrication of LT panel. (iv) Cost of plate form, MCCB spreders, cable glands , locking arrangement with lock and key of approved make and minor addition /alteration if required at site shall be included in the item rate.
Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI earth strip of size 32 x 6mm thick, soldered and revetted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I complete all as specified and directed. . NOTE: GI strip upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately.
Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI wire of size 4mm thick, soldered and revetted to earth plate. GI wire will be protected by using 20mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I complete all as specified and directed. NOTE: GI wire upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately.
M&L for GI strip 32 x 6 mm by taking down the old exiting earth strip any size inside hanger, fixing with proper clamp, saddles, nut bolts , washers etc properly and connected to equipment or panel complete all as specified and directed .
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPN, 4 ways, 415 Volts with 200 Amps rated bus bar suitable for TPN MCB / 4 pole isolator fixed properly on in concealed position and to provode required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed. Make:ABB/Schiender/Legrand/Havells.
S&F MCB TPN 415 volts, 40-63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. Make: ABB/Schiender/Legrand/Havells.
Supply and fixing on wall MCCB 415 Volts 250 Amps capacity , 36 KA, Ics=100% Icu, Four pole with Sheet steel enclosure for sutable size of MCCB with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands and fixing arrengement on pole/wall ,PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed . Make of MCCB:- ABB/Schiender/Legrand/Havells.
S & F LED Aviation light of die-cast aluminum housing with red polycarbonate dome, integral driver with ingress protection IP-65, and voltage range 100-270V AC complete all as specified and directed. Make :- Bajaj (cat part No- BGAV 302 LED) or equivalent in Philips, Wipro.
VEE KAY ENTERPRISES
MITHILA BUILDERS AND ENGINEERS
m/s A.A brothers
SEEMA ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .