Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.0 LAccepted-AOC | ₹52.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹56.6 LRejected-AOC VILL P O PUINAN DIST HOOGHLY PIN 712305 | PUINAN | HOOGHLY | WEST BENGAL | 712305 | ₹56.6 L | L2 | Rejected-AOC L2 |
| 3 | L3₹56.9 LRejected-AOC ALAMGANJ GHATAL PASCHIM MEDINIPUR 721212 | GHATAL | PASCHIM MEDINIPUR | WEST BENGAL | 721212 | ₹56.9 L | L3 | Rejected-AOC L3 |
| 4 | L4₹57.2 LRejected-AOC | ₹57.2 L | L4 | Rejected-AOC L4 |
Tender Value
₹56.6 L
EMD Value
₹1.1 L
Closing Date
13 Feb 2026, 2:00 pmClosed
Executive Engineer(A-M)Midnapore(A-M) Division
Administrative Building.-Dak Banglow Rd, Saratpally, Midnapore, Pin- 72ll0l
Renovation of Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the FY-25-26.
2026_WRDD_995456_1
WBWRDD/EE(AM)MID/eNIT-78/25-26
Open Tender
Project Work
180 days
Executive Engineer(A-M)Midnapore(A-M) Division
Please refer Tender documents.
2 documents required · 2 mandatory
₹1.1 L
2 Mar 2026
29 Jan 2026
16 Feb 2026
29 Jan 2026
13 Feb 2026
29 Jan 2026
Laying of WTA at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000. ( Please see the details in WTA)
Procurement of Material at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000. ( Please see the details in POCUREMENT OF MATERIAL)
Supply of Field Level Material at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000. ( Please see the details in FIELD LEVEL MATERIAL)
Internal Wiring of Pump House at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000. ( Please see the details in IW)
Please Enable Macros to View BoQ information
Percentage BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Laying of WTA at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in excavation of field trenches as per design section and alignment for laying of pipe lines (PVC, RCC, ACP etc.) upto a depth of 1500 mm all sorts of soils including removing, spreading or stacking extra earth as directed. The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Laying of P.v.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. Ø 140 mm pipe
Ø 200 mm pipe :
(i) 315 mm dia.
Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. i) With approved graded stone chips (20 mm size).
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel III. Other Manufacturers not specified
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (c) 15 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m.
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site).
Installation / Erection of SurgeTank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) of Pakur variety of 1250 mm X 1250 mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concretebase including cost of all materials and labour and as perdirection of Engineer-in-Charge.
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i)(a) 150 mm. dia. ERW pipe.
Labour charges for fitting and fixing 140 mm dia Alfa-Alfa valve with 140 mm dia class-II UPVC riser pipe with the help of flanged PVC tail piece by joining the PVC end of Tail piece and riser pipe with coupler and flanged end of tail piece and flap valve with rubber insertion, nuts and bolts etc. complete.
Supplying, fitting and fixing including transportation of sign board for identifying the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base -Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C.
Transportation of Diesel Engine pumping set / Electro-Motor pumping set for Major R.L.I. of any make/brand with necessary fixtures viz. M.S. bend, M.S. Pipes, Rubber Hose Pipe, Manifold, Surge tank, foot valve, non-return valve, tail piece, hose clamp, sluice valve, priming chamber etc. over Pucca/Kancha road from Sub-Divisional Store to worksite including loading at the lifting point and unloading at the delivery point.Distance upto 50 km.B) for Electro motor (a)Carriage by Road ii) Distance up to 50km
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge. (i) For Major R.L.I.
Total Rs.
Add @ 4% Carriage excluding Earth Works
Sub-Total Rs.
Add GST @ 18%
Sub-Total Rs.
Labour welfare Cess @1%
Grand Total Rs.
Say Rs
Percentage BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Procurement of Material at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000.
UPVC and P.V.C. PIPES & ACCESSORIES 315 mm dia P.V.C pipe class-I ( with a loose matching coupler) marking IS No. 4985/1988 with latest amendments with free solvent cement.
200 mm. dia P.V.C. pipe Class- I ( with a loose matching coupler) marking IS No. 4985/ 1988 with latest amendments with free solvent cement.
140 mm. dia P.V.C. pipe Class- I ( with matching coupler ) marking IS No. 4985/1988 with latest amendments with free solvent cement.
140 mm. dia P.V.C. pipe Class-II ( with a loose matching coupler) marking IS No. 4985/ 1988 with latest amendments with free solvent cement.
200X200X200 mm dia P.V.C. Equal Tee with free solvent cement. IS-10124.
140X140X140 mm dia P.V.C. Equal Tee with free solvent cement.IS-10124.
315 mm. dia (IS.No. 10124/88 Part- 8 with latest amendment) F.T.P.
200 mm.. dia ( IS. No. 10124/ 88 Part- 6 with latest amendment) F.T.P.
160 mm. dia ( IS. No 10124/88 Part- 6 with latest amendment) F.T.P..
200 X 140 mm dia.P.V.C. Reducer (Class-II) with free solvent cement. IS-10124
160 X 140 mm dia.P.V.C. Reducer (Class-II) with free solvent cement. IS-10124
200 mm. dia 60deg ( IS. No. 10124/88 Part- 8 with latest amendment ) bend
140 mm. dia 90deg (IS. No. 10124/ 88 Part- 8 with latest amendment) bend
140 mm. dia 60deg ( IS No. 10124/ 88 Part- 8 with latest amendment ) bend
200 mm. dia IS. NO. 10124/ 88 Part- 4 with latest amendment End cap.
140 mm. dia IS. NO. 10124/ 88 Part- 4 with latest amendment End cap.
Extra Coupler for 315 mm. dia P.V.C. pipe (extra) IS. 10124/1988 with latest amendments with free solvent cement.
Extra Coupler for 200 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement.
Extra Coupler for 140- mm. dia P.V.C. pipe (extra) I.S 10124/ 1988, Part- II with free solvent cement.
150 mm dia ISI marked P.V.C.Flexible Hose pipe as per IS 15265
Extra Solvent cement heavy bodied I.S. 14182-1994 with latest amendments
MS / GI ITEMS & ACCESSORIES GI Quadrupped Set and Inlet & Outlet Pipe Fittings, with good quality painting (2 nos. chamber for 1 set) as per annexeure drawing- I for Major RLI. All materials ISI marked (as per appreved drawing & Technical specification.
Sluice valve ISI marked Ø 150 mm P.N 1.6 with hand wheel for water works purpose, C.I flanged type conforming to IS 14846/2000 with latest amendments. Valves shall be tested for (closed end test) hydrostatic test requirement.
C.I Alfa Alfa valve 150 mm dia C-type. ISI Marked- IS-14846
Supply of 150 mm dia Galvanized MS flanged pipe ISI marked (IS 1239)
ELECTROMOTOR PUMP & ELECTRICAL ACCESSORIES 20 H.P Electro Motor Pump set having capacity of 200 cubic meter per hour discharge at 24 meter total head. The Motor shall be designed for operation at 415 V (±10%), 3 Phase, 50 Cycles per Sec (±5%), A.C Supply 1500 r.p.m. The Motor shall be TEFC ISI marked as per IS 12615 with latest amendments thereof. The Pump ( size 150 x150 mm.) shall be horizontal, single stage, split casing, as per IS-6595/1993 with latest amendments hereof. Pump should be directly coupled with Motor and mounted on a common fabricated M.S Base frame. 25 H.P. ,200 m³/hr,24 m head.
Supply of 20 Hp Automatic starters suitable for use with 380/415 volt 3 phase 50 hz AC supply & conforming to IS 13947(pt-4) (20 HP)
Supply of 200Amp four pole Busbar chamber with Copper bars of 30 cmX2.5cmX0.6cm provided with requisite bolts (with insulated cap), nuts, washers in CRCA sheet metal enclosure of thickness 17 swg (1.22mm) having dimension of 36cmX29cmX15cm with rating & WRDD letter embossed on cover, with continuous welded smoothly chamfered edged, dust and vermin proof, stove enameled/ powder coat painted and with raised mounting arrangement.
Sheet metal enclosed rewireable type Fuse, Main Switch, 415 V 3 v Phase , 50 cycles A.C. supply conforming to IS 60947 (Part-3) /1993 for 200 Amp TPN.
Sheet metal enclosed rewireable type Fuse, Main Switch, 415 V 3 v Phase , 50 cycles A.C. supply conforming to IS 60947 (Part-3) /1993 for 63 Amp TPN.
Total Rs.
Add Labour Cess @1%
Grand total
Say Rs
Percentage BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supply of Field Level Material at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000.
M.S. Hose Clamp 150 mm dia heavy duty (As per sample)
Foot Valve 150 mm.dia commercial (Flanged type) confirming IS:4038/1986 with latest ammendment
Foot valve Lather washer 150mm.dia (asper sample)
150 mm NB MS 90 degree short primming bend one flange welded and other end ring welded with free baking flange. IS-1239. (As per sample)
150 mm NB MS 90 degree both end flange. IS 1239. (As per sample)
C.I Non return valve flanged end and swing type side bypass arrangement conforming to IS15312(Part-I/2004)with latest arrangement.
M.S Reducer 200X150 mm both end flanged
Nuts & Bolts (GI) M 20x80 mm.
C.I. Flanged Tail piece/Nipple 150 mm dia. (As per sample)
150 mm NB CI Combined nipple both end grooved (As per sample)
Foundation Bolt For Distribution Chamber (As per sample)
For Motor Pump Sets (As per sample)
Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392) 500 mm.dia (Table-5)
Rubber Insertion (for raised surface of Flange as per IS-6392) 300 mm dia( Table-11) (As per sample)
300 mm dia( Table-5) (as per sample)
200mm.dia( Table-11) (as per sample)
200 mm. dia (Table-5) (as per sample)
150 mm.dia (Table -17) (as per sample)
150mm.dia (Table -5) (as per sample)
80 mm.dia (Table-17) (as per sample)
Total Rs.
Add Labour Cess @1%
Grand total
Say Rs
Percentage BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Internal Wiring of Pump House at Kapastikri Major RLI Scheme at Mouza-Kapastikri, JL No- 530, Plot No- 835, in Keshpur Block of Paschim Medinipur District under E.E.(AM), Midnapore (AM) Division under Sorasori Mukhyamantri (Core Sector) Programme during the F.Y. 2025-26. Project ID- WI252640562S000.
Supplying , fitting and fixing of wooden panel board of size 6' X 4' X 1" fitted with 1" X 1.5" wooden frame with 6 nos. of necessary nut & bots for mounting on the wall of pump house.
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V DP with fuse on L&N 15/16 A Havells
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) including necessary PVC clips, fittings etc. c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] b) Average run 5 mtr
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] a) On Board
Supply & Fixing angular batten holder(Anchor) on 75mm dia PVC round block/round bakelite on wall/ceilling.
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 9 watt LED lamp complete set.
Fixing only 200A, 415V, TPN sheet steel Main Switch (Rewirable type) on flat iron frame/Angle iron frame on wall.
Fixing only MS sheet metal 200 Amps, 4 bars busbar Chamber on angle iron frame on wall. (PWD elec. Sh. Page-C-1,Item -6)
Fixing only 63 A, 415V TPN Sheet Steel Main Switch (Rewirwable type)/ Change over on Angle Iron Frame on wall (PWD elec. Sh. Page-C-1,Item -1)
Fixing only 20 HP Star-Delta starters for 20 HP motor on angle iron frame on wall
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections Ammeter-4, Voltmeter-2
Laying of cables upto 3/4 core 25 sqmm on wall/surface incl. S&F MS saddles with earthing attachment in 10 SWG GI(Hot Dip) wire, making etc. as necessary mending good damages and painting. i) 10 sqmm Copper Cable (from meter to 200A main Switch and 200 A main Switch to Busbar Chamber)
ii) 6 sqmm Copper Cable (from Busbar chamber to 63 Amp Main Switch to Starter to motor)
Earthing with 50 mm (2") dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2") dia X80 mm (3") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe
Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. i) No 10 SWG (Earth Busbar to Every Equipment)
Supply & Fixing EI danger board on wall 20 cm x 30 cm (8"x12") in two distinguishing position in the door of pump house (outside) and at the palce of panel board
Supplying fitting & fixing of shock treatment chart (Bengali) in a wooden frame with brass.
Installation of Diesel Engine Pumping set of any make / brandand for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-incharge. (Pump set and all accessories will be supplied departmentally).
Total Rs.
Add GST @ 18%
Sub-Total Rs.
Labour welfare Cess @1%
Grand Total Rs.
Say Rs
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
Tendernotice_2.pdf
PDF • 0.95 MB
BOQ_2435950.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid