REPAIR /MAINTENANCE OF SUMMER/ WINTER APPLIANCE AN
REPAIR /MAINTENANCE OF SUMMER/ WINTER APPLIANCE AND MISC E/M WORKS UNDER AGE (HOSP) AT GE(U) E/M MEERUT CANTT
REPAIR /MAINTENANCE OF SUMMER/ WINTER APPLIANCE AND MISC E/M WORKS UNDER AGE (HOSP) AT GE(U) E/M MEERUT CANTT
2020_MES_381414_1
8255/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Meerut Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
REPAIR /MAINTENANCE OF SUMMER/ WINTER APPLIANCE AN
₹19,800
Yes
7 Feb 2021
20 Oct 2020
26 Nov 2020
20 Oct 2020
19 Nov 2020
4 Nov 2020
20 Oct 2020 - 29 Oct 2020
Amount
S&F ( in repairs) Fancy type Bib taps , CP, cast copper alloy with crutch or butterfly handle , screwed down , scrwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified.
Taking down old unserviceable stop valves and S&F Chromiuim plated, fancy type Stop valves, cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified
Taking down old unserviceable mild steel clapms and M&L mild steel Bands, straps, supports or stays for rainwater , fan clamps Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and pintol hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde -E-165 complete all as specified.
Taking up or down steel tubing and connections , including and removal and M&L 15 mm nominal bore Mild steel galvanised water tubing , medium grade (ISI) marked , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball , suitable for 15 mm bore pipe, screwed for iron pipe and fixed. .(Minimum weight 20mm-210 gms.) complete all as specified.
Renewal of SPN Sheet metal enlosures (factory made) with 10KA, 'B' curve Single pole MCB rated 10 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall,mounted flush including making good distured surfaces to match with the existing complete all as specified.
GEYSERS
Taking down carefully storage type water heater( geysers) of 25 and /or 50 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing/ cutting of holding bolts/ nuts from walls and de-assembling it for repair including taking out inner assembly and scraping scale deposits on the surface of assembly and water pipe, cleaning and washing and re-assembling after repairs and fixing the same in its original position by using new mild steel expsnsion fastners /bolts, nuts and washers of required size , making good disturbed surfaces to match with existing and making necessary water supply and electric connection and testing complete all as specified and directed. Note:- Parts renewed shall be measured and paid separately under appropriate items
Renewal of Bronze non return valve (ISI marked) suitable for 15mm nominal bore of pipe, heavy duty complete all as specified.
Renewal of copper sheathed and nickel plated heating element 1.5 KW (ISI marked) triangilar/ Cup shaped push/ threaded type suitable for horizontal or vertical type water storage type water heater( Geysers) all as specified and directed.
Renewal of copper sheathed and nickel plated heating element 2 KW (ISI marked) triangilar/ Cup shaped push/ threaded type suitable for horizontal or vertical type water storage type water heater( Geysers) all as specified and directed.
Renewal of CP Brass inlet and outlet assembly complete with rubber gasket, nuts, bolts and washers including copper sheathed and nickel plated heating element 2 KW (ISI marked) triangilar/ Cup shaped push/ threaded type suitable for horizontal or vertical type water storage type water heater( Geysers) all as specified and directed.. for 25/ 50 litre capacity storage type water heater complete all as specified and directed.
Renewal of thermostat, minimum 300 mm long, suitable for any make & type of geyser 25 / 50 litres capacity horizontal or vertical type all as specified and directed.
Renewal of Bellow thermostat suitable for any make & type of geyser 25 litres capacity horizontal or vertical type all as specified and directed.
Renewal of Bellow thermostat suitable for any make & type of geyser 50 litres capacity horizontal or vertical type all as specified and directed.
Renewal of neon Indicator Bulb ( Red and green) all as specified and directed.
Renewal of spring loaded air release safety valve 15mm dia made of Brass Nickle/ Chromium plated all as specified and directed.
Renewal of stainless steel inner cell of 25 litres capacity geyser and making connections by brazing including all asseccories all as sepcified and directed.
Renewal of stainless steel inner cell of 50 litres capacity geyser and making connections by brazing including all asseccories all as sepcified and directed.
Renewal of steel assembly heavy duty powder coated to match with the colour of existing geysers suitable for 25 litres capacity all as sepcified and directed.
Renewal of steel assembly heavy duty powder coated to match with the colour of existing geysers suitable for 50 litres capacity all as sepcified and directed.
Renewal of PVC connection heavy duty suitable for Hot/ Cold water connections in geysers braided 450mm long with flare brass nuts on both ends complete all as specfied.
Renewal of hex nipple 15mm bore heavy duty complete all as specfied.
Taking down old existing unserviceable geysers and Supplying, assembling,fixing, testing and commissioning Stationary Storage Type Electric Water Heater ( Geysers) of 25 Litres capacity , ISI marked , single phase, 240V, AC, 50 Hz, Metalic body, white powder coated externally, with stainless steel tank ( vessel) with standard KW heating element, thermostat etc. complete including cutting holes, grouting 12mm dia 100mm long mild steel bolts supplied with nuts and washers, providing twisted 3 core 23/.0076 copper conductor flexible PVC insulated wire of required length including engraving and painting MES number with Black Bold letters with synthetic enamel paint upto 2.50cm high, making conncetions to inlet and outlet water supply system complete including making good to all as specified and directed.
WINDOW TYPE AIR CONDITIONER
Dismantling of unserviceable Hermetically sealed compressors of 1.5 TR capacity from window type air conditioners including disconnecting suction / discharge copper tubing and S&F compressor Model No. AW-1500 of TECUMSEH with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas complete all as directed by EIC. Note :_ (i) Supply and charging of Referengent gas shall be measured separately
Dismantling of unserviceable Rotary compressors of 1.5 TR capacity from window type air conditioners including disconnecting suction / discharge copper tubing and S&F compressor of make LG/Carrier/Tecumseh/Bluestar/Voltas with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas complete all as directed by EIC. Note :_ (i) Supply and charging of Referengent gas shall be measured separately
Dismantling of unserviceable Rotary compressors of 2 TR capacity from window type air conditioners including disconnecting suction / discharge copper tubing and S&F compressor of make LG/Carrier/Tecumseh/Bluestar/Voltas with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas complete all as directed by EIC. Note :_ (i) Supply and charging of Referengent gas shall be measured separately
M&L for Checking of leakage in refrigerant system of Window air conditioners of any capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging with refrigerant gas in required quantity all as directed by Engineer-in-Charge .
Supply & fixing (in repairs) capacitor 6mfd (conforming to IS:2993 - 1975) AC 230/270 volts in plastic container 6 mfd complete all as specified and directed .
Supply & fixing (in repairs) starting capacitor (conforming to IS:2993 - 1975) AC 230/270 volts in plastic container 100-120 mfd complete all as specified and directed .
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) 230 volts in plastic container of 36 Mfd suiatble for split air conditioners complete all as specified and directed.
Supply & fixing (in repairs) relay set suitable for Window type air Conditioners complete all as specified and directed .
Taking out defective burnt motor of 1/10 HP single phase of any make double shafted of 1.5 TR capacity Window type AC and transporting to contactor's workshop, opening of motor taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled aluminium winding wire including insulation varnishing, greasing, reassembling, renewal of bushes testing and fixing in position all as directed by EIC.
Renewal of wiring Kit suitable for 1.5 TR capacity window type air conditioners of any make complete all as specified.
Renewal of Liquid line filter for 1.5 TR Window Type Air Conditioner of any capacity all as specified and directed.
Supply & fixing (in repairs) air filter made out of pressed coco filter / nylon complete all as specified and directed .
Renewal of Condensor , Cooling Coil, of window type Air conditioner of 1.5 TR capacity consisting duly powder coated complete all as specified and directed.
Renewal of Condensor Fan Blade made of Aluminium/ plastic for window type AC 1.5 TR capacity of make as approved by EIC complete all as specified and directed.
Renewal of Blower made of Aluminium/ plastic for window type AC 1.5 TR capacity of make as approved by EIC complete all as specified and directed.
Supply & fixing (in repairs) front grill of window type AC of any make suitable for 1.5 TR capacity window type Air conditioners complete all as specified and directed .
M & L for servicing of Window type Air conditioners by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete of any capacity all as specified and directed by EIC.
SPLIT TYPE AIR CONDITIONERS
Dismantling of unserviceable compressors of 1.5 TR capacity including disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas complete all as directed by EIC. Note :_ (i) Supply and charging of Referengent gas shall be measured separately
Dismantling of unserviceable compressors of 2 TR capacity including disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas complete all as directed by EIC. Note :_ (i) Supply and charging of Referengent gas shall be measured separately
M&L for Checking of leakage in refrigerant system of split Air conditioners of any capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging with refrigerant gas in required quantity all as directed by Engineer-in-Charge .
Renewal of air filter made out of Nylone suitable for 1.5 TR capacity air conditioners of any make complete all as specified.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 230 volts in plastic container of 45 Mfd suiatble for split air conditioners complete all as specified and directed.
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR and supply & fixing new condensing unit ( except compressor) complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as directed .
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing indoor unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same, remote sensor unit with remote all as specified and directed.
Renewal of wiring Kit suitable for 1.5 TR capacity air conditioners of any make complete all as specified.
Renewal of condensing fan Blade made out of Aluminium/ plastic suitable for split air conditioners of any make complete all as specified.
Renewal of blower motor made of plastic suitable for split air conditioners of any make complete all as specified.
Supply & fixing (in repairs) starting capacitor (conforming to IS:2993 - 1975) AC 230/270 volts in plastic container 125-150 mfd complete all as specified and directed .
Supply & fixing (in repairs) relay set suitable for split Air Conditioners complete all as specified and directed .
S&F ( in repairs) suction copper pipe line heavy duty 1/4” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F( in reapirs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F( in reapirs) discharge copper pipe line heavy duty 5/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
M & L for servicing of split type air conditioners comprising Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete of any capacity all as specified and directed by EIC.
Renewal of Printed circuit Board ( PCB) of split/ window type Air conditioners complete all as specified.
Converting the existing AC (window / split) type from cooling system to heating system of the existing AC by using necessary items/ equipments/toggle switch etc. from window/split type of any capacity including S&F reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing , charging refrigerent gas of required quantities and PCB etc. complete all as specified and directed. Note:- Refrigerent gas filled shall be measured separately
WATER COOLERS
Cleaning of water cooler tank with Potassium permanganet solution after removing all dust, mud particles complete all as specified.
Repairing the water cooler storage tank of stainless steel or any other metal by providing welding, brazing/soldering and making the tank leakage proof complete all as specified and directed.
M&L for renewal of harmertically sealed unit Compressor Model no. Kirloskar-4440 with necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of harmertically sealed unit Compressor Model no. Kirloskar-AHR-13 wiith necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of harmertically sealed unit Compressor Model no. Kirloskar-AE-436 wiith necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of harmertically sealed unit Compressor Model no. Tecumseh-4445 wiith necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of harmertically sealed unit Compressor Model no. Tecumseh-AW1000 wiith necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for Checking of leakage in refrigerant system of water cooler of any capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging with 134 Floron refrigerant gas in required quantity all as directed by Engineer-in-Charge .
Renewal of relay set consisting overload protector suitable for water coller compressor any capacity all as directed by Engineer-in-Charge.
Renewal of condenser fan motor single phase, with blade,1/35 HP capacity including moutning clamps, bushes, nuts, bolts and washers of water cooler complete all as specified and directed.
Renewal of condenser fan motor single phase, with blade,1/10 HP capacity including moutning clamps, bushes, nuts, bolts and washers of water cooler complete all as specified and directed.
Renewal of Liquid line filter for water cooler of any capacity all as specified and directed.
Renewal of thermostat for water cooler all as directed by Engineer-in-Charge.
Renewal of Brass CP push cock 15mm bore with brass flex nipple complete all as specified.
Renewal of 32 mm bore PVC flexible pipe complete all as specified and directed.
DEEP FREEZER
M&L for renewal of harmertically sealed unit Compressor of 320 litres capacity DEEP FREEZER of make LG/Videocon/Bluestar/Carrier duly including necessary brazing work to make the system leak proof complete all as specified and directed.
REFRIGERATOR
M&L for renewal of sealed unit Compressor of 320 litres capacity Refrigerator of make LG/Videocon/Whirlpool/Voltas duly including necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of sealed unit Compressor of 165 litres capacity Refrigerator of make LG/Videocon/Whirlpool/Voltas duly including necessary brazing work to make the system leak proof complete all as specified and directed .
M&L for Checking of leakage in refrigerant system of refrigerator and deep freezer of any capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging with 134 Hydro Carbon refrigerant gas in required quantity all as directed by Engineer-in-Charge .
Renewal of Liquid line filter for refrigerator of any capacity all as specified and directed.
Renewal of starting relay, open type for refrigerator of any capacity all as directed by Engineer-in-Charge.
Renewal of over load protector for refrigerator of any capacity all as directed by Engineer-in-Charge.
Renewal of thermostat with knob defrost type/ non defrost type for refrigerator all as directed by Engineer-in-Charge.
Renewal of Evaporation fan motor single phase, 230V, AC for any make and capacity for refrigerator complete all as specified.
Renewal of freezer cabinet with door comprising spring suitable for following capacity refrigerator complete all as specified.
Renewal of condensing coil of any capacity refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as directed. Note: Refrigerant gas supplied and charged shall be measured and paid separately).
DESERT COOLER
Taking out defective burnt exhaust /kit fan motor of 1/10 HP, any sweep and of any make and transporting to contactor's workshop, opening of motor taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled aluminium winding wire including insulation varnishing, greasing, reassembling testing and fixing in position all as directed by EIC.
Renewal of aluminium body kit fan motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 20" sweep size, fixing lungs, nuts, bolts and washers suitable for desert cooler all as specified and directed by EIC.
Renewal of submersible mini water lifting pump, single phase, 230 volt AC, 50 HZ, 1/40 HP ( 18 watts approx) , of 5 meter head all as specified and directed by EIC .
Renewal of wood wool pad suitable for desert cooler all as directed by E.I.C
Renewal of PVC pipe 15mm dia, medium quality for desert cooler all as directed by E.I.C
Renewal of desert cooler body of size 1Mx1Mx1.2M, suitable for 450 mm/500 mm sweep exhaust fan /kit, made out of 18gauge PGI sheet and side panels duly filled with Khas khas including painting the inner surafces with one coat of anticorrosive paint and outer surfaces with two coats of synthetic enamel paint over a coat of primer, deassembling the fan, pump and its connected fittings, grills, regulator and cable etc.from wornout body and fixing the same in renewed Cooler Body complete all as specified and directe.
Renewal of desert cooler side panels of desert cooler, made out of 22 gauge PGI sheet and side panels duly filled with Khas khas including painting the inner surafces with one coat of anticorrosive paint and outer surfaces with two coats of synthetic enamel paint over a coat of primer to match with the Body of desert cooler complete all as specified and directe.
VOLTAGE STABLISER
Rewinding of main power transformer of 5 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
Rewinding of main power transformer of 4 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
Rewinding of main power transformer of 3 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
Rewinding of main power transformer of 2 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
Rewinding of main power transformer of 1 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
Rewinding of main power transformer of .5 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
Renewal of cut off relay suitable for 5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of cut off relay suitable for 4 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of cut off relay suitable for 3 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of cut off relay suitable for 2 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of cut off relay suitable for 1 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of cut off relay suitable for 0.5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of High/ low cut off with time delay circuit suitable for 5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of High/ low cut off with time delay circuit suitable for 4 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of High/ low cut off with time delay circuit suitable for 3 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of High/ low cut off with time delay circuit suitable for 2 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of High/ low cut off with time delay circuit suitable for 1 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of High/ low cut off with time delay circuit suitable for 0.5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Printed circuit Board (PCB) suitable for 5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Printed circuit Board (PCB) suitable for 4 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Printed circuit Board (PCB) suitable for 3 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Printed circuit Board (PCB) suitable for 2 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Printed circuit Board (PCB) suitable for 1 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Printed circuit Board (PCB) suitable for 0.5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Trigger Transformers suitable for 5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Trigger Transformers suitable for 4 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Trigger Transformers suitable for 3 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Trigger Transformers suitable for 2 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Trigger Transformers suitable for 1 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of Trigger Transformers suitable for 0.5 KVA capacity Voltage stabliser complete all as specified and directed.
Renewal of single phase Voltmeter AC, 230 Volts for Voltage stabliser complete all as specified and directed.
Renewal of indicator bulb suiatble for for Voltage stabliser complete all as specified and directed.
CEILING FANS / EXHAUST FANS
Taking down of existing unserviceable ceiling fans and Supplying , fixing and testing ceiling fan 1400mm sweep, white/ coloured comlete with down road, canopy making connections with and including 3 core flexible cable, PVC insulated with Stranded copper conductor of suitable size complete all as specified and directed.
Taking down of existing unserviceable wall fans and S&F wall mounting fan 400 mm sweep including making connections with suitable size of copper wire and making good surfaces complete all as specified.
Taking down existing unserviceable ceiling fan of 1200mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled aluminium winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified.
Taking down existing unserviceable ceiling fan of 1400mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled aluminium winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified.
Taking down existing serviceable ceiling fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified.
Taking down existing unserviceable exhaust fan of 450mm/380mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled aluminium winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified.
Taking down existing unserviceable exhaust fan of 300mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled aluminium winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified.
Taking down existing serviceable Exhaust fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified.
Renewal of cylinder capacitor 2.5 MFD with earthing terminal for ceiling fan / Exhaust fan / cabin fan motor including soldered leads for connections ISI-1709 , MPP ( metallised polypropylene , SH( self healing) , of the following capacities complete all as specified .
Renewal of cylinder capacitor 3.15 MFD with earthing terminal for ceiling fan / Exhaust fan / cabin fan motor including soldered leads for connections ISI-1709 , MPP ( metallised polypropylene , SH( self healing) , complete all as specified .
Renewal of cylinder capacitor 4 MFD with earthing terminal for ceiling fan / Exhaust fan / cabin fan motor including soldered leads for connections ISI-1709 , MPP ( metallised polypropylene , SH( self healing) , complete all as specified .
Renewal of ball bearing of any size for celing fans/ exhaust fans/ wall bracket fan, cabin fans , table fan etc(bearing number 6201,6202,6203 as required). all as specified and directed.
Taking out unserviceable bush from ceiling fan and making arrangement for ball bearing by lathing at workshop complete all as specified and directed.
Renewal of Gunmetal bush bearing of suitable for ceiling fans / exhaust fan / cabin fan etc. of any size complete all as specified and directed.
Renewal of mild steel hanging clamps suitable for any sweep of fans including necessary nuts, bolt and washers and split pin complete all as specified and directed.
Renewal of upper and lower plastic canopy of any sweep of ceiling fans complete all as specified and directed.
Renewal Poly carbonate Body plug top 3 pin, 16 Amps, ,230 Volts complete all as specified.
Renewal Poly carbonate Body plug top 3 pin, 6 Amps, ,230 Volts complete all as specified.
BASANT RAM AND SONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .