| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAccepted-AOC | ₹3.8 Cr Quoted ₹3.5 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹3.8 Cr+₹26.3 L (7.47%)Rejected-AOC PLOT NO 14 15 N 20 DYNA FILTERS PVT LTD PLOT NO 14 15 20 PUNE SOLAPUR RD HADAPSAR PUNE MAHARASHTRA 411028 UDYAM MH 26 0014110 27AACCD4903E1Z1 R M MII STATUS AS VERIFIED | PUNE | MAHARASHTRA | 411028 | ₹3.8 Cr+₹26.3 L (7.47%) | L2 | Rejected-AOC Reject L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per Technical Evaluation Report |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per Technical Evaluation Report |
Tender Value
₹3.2 Cr
EMD Value
₹3.2 L
Closing Date
10 Aug 2022, 3:00 pmClosed
Managing Director
Maharashtra State Agricultural Marketing Board, Plot No. R-7, Marketyard, Gultekadi, Pune 411 037
CW-4 c - Upgradation and Expansion of Existing Facility at Pune Division - NIPHT, Talegaon
2022_CMTAD_811674_1
MSAMB/ENGG/ADB/MAGNET/CW-4 (c)
Open Tender
Civil Works - Others
Item Rate
365 days
Talegaon, Tal. Maval. District Pune
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
₹3.2 L
Yes
MSAMB, Head office, Pune
13 Apr 2023
24 Jun 2022
10 Aug 2022
24 Jun 2022
10 Aug 2022
8 Jul 2022
24 Jun 2022 - 1 Jul 2022
4 Jul 2022
Export Facility Centre, NIPHT Premises, Talegaon Dabhade, Dist: Pune
CIVIL WORK
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means (SSR 2021-22, Item no.21.02, Page no.115, Additional specification Bd.A.1 Page No.259)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means (SSR 2021-22, Item no.21.06, Page no.115, Additional specification Bd.A.2,Page No.259)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means (SSR 2021-22, Item no.21.10, Page no.115, Additional specification Bd.A.3 Page No.259)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means (SSR 2021-22, Item no.21.14, Page no.116, Additional specification Bd.A.2, Page No.259)
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m) By Mechanical Means (SSR 2021-22, Item no.21.20, Page no.199, Additional specification Bd.A.6 Page No.260)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. (SSR 2021-22, Item no.21.22, Page no.116, Additional specification Bd.A.5 Page No.260)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. (SSR 2021-22, Item no.21.24, Page no.117, Additional specification as directed by Engineer incharge)
Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. (SSR 2021-22, Item no.21.34, Page no.117, Additional specification as directed by Engineer incharge)
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. (SSR 2021-22, Item no.21.36, Page no.117, Additional specification Bd.A.10 Page No. 262)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. (SSR 2021-22, Item no.21.37, Page no.117, Additional specification Bd.A.11 Page No. 263)
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. (SSR 2021-22, Item no.21.38, Page no.117, Additional specification Bd.A.12 Page No. 264)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc complete. (SSR 2021-22, Item no.21.40, Page no.118, Additional specification Bd.A.12 Page No. 264)
Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mildsteel plated, angle brackets, cleats, gussetplates, anchorbolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two.coats of oil painting approved quality and shade etc. complete.(SSR 2021-22, Item no.23.03, Page no.129, Additional specification Bd.C.12 Page No. 277)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc (SSR 2021-22, Item no.24.01, Page no.131, Additional specification Bd.E.1 Page No. 287)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.24.04, Page no.131, Additional specification Bd.E.2 Page No.131 and B.7 Page No 38)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.25.13, Page no.133, Additional specification Bd.C.12 Page No. 275)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as perdetailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.25.33, Page no.134, Additional specification Bd.F.3 Page No.134 and B.7, PageNo.38)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.25.52, Page no.135, Additional specification Bd.F.6 Page No. 135 and B.7, Page No.38)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc (SSR 2021-22, Item no.25.72, Page no.136, Additional specification Bd.F.8 Page No.136 and B.7, Page No.38)
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2021-22, Item no.26.07, Page no.239, Additional specification Bd.F.9 Page No.303 and B.7, Page No.38)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)(SSR 2021-22, Item no.26.19, Page no.240, Additional specification Bd.F.11 Page No.304 and B.7, Page No. 38)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (SSR 2021-22, Item no.26.33, Page no.245, Additional specification Bd.F.17, Page No.306)
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks,laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc. (SSR 2021-22, Item no.26.23, Page no.240, Additional specification Bd. F. 12 Page No.138 and B-7, Pg 38)
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. (SSR 2021-22, Item no.27.12, Page no.144)
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. (SSR 2021-22, Item no.27.13, Page no.144)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. (SSR 2021-22, Item no.27.05, Page no.144, Additional specification Bd.G. 5 Page No.315)
Providing uncoursed rubble masonry of trap / granite / quartzite /gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc. complete. (SSR 2021-22, Item no.28.01, Page no.146, Additional specification Bd.H.1 Page No.329)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. (SSR 2021-22, Item no.31.04, Page no.150, Additional specification As directed by engineer incharge)
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.(S.S.R.2021-12, Item no.31.05, Page no.264, Additional specification As directed by engineer incharge)
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. (SSR 2021-22, Item no.32.02, Page no.153, Additional specification Bd.L.1 Page No.367)
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (SSR 2021-22, Item no.32.03, Page no.153, Additional specification Bd.L.2 Page No.367)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (SSR 2021-22, Item no.32.11, Page no.153, Additional specification Bd.L.7 Page No.369)
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2021-12 Item No 32.26 P.No.270, additional spec no. As directed by Engineer in Charge)
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (SSR 2021-22, Item no.32.34, Page no.155, Additional specification As directed by Engineer in charge.)
Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete. (SSR 2021-22, Item no.33.08, Page no.156, Additional specification Bd.M.3 Page No.380.)
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. (SSR 2021-22, Item no.33.30, Page no.158, Additional specification As directed by Engineer in charge..)
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc complete (SSR 2021-22, Item no.33.35, Page no.158, Additional specification Bd.M. 22/PageNo. 390.)
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS.15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc.complete. (S.S.R.2021-12, Item no.33.42, Page no.279, Additional specification Bd.M.12 Page No.385.)
Providing and laying chequered tiles of approved qualityof size 30 cm x 30 cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. (S.S.R.2021-12, I.No.33.66. P.No.283. Additional Specification Bd. M-12 page No. 385)
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (S.S.R.2021-12, Item no.33.67, Page no.283, Additional specification : Bd. M-12 page No.385 )
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/ moulding the sharp edges wherever necessary, curing, etc. complete. (S.S.R.2021-12, Item no.33.68, Page no.283, Additional specification As directed by engineer incharge )
Providing and applying two coats of lead/zinc base oil paint/ bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete. (excluding primer coat). (SSR 2021-22, Item no.35.04, Page no.164, Additional specification :- Bd.O.5 Page No. 405)
Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. (SSR 2021-22, Item no.35.20, Page no.165, Additional specification As directed by Engineer in charge. )
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR 2021-22, Item no.35.21, Page no.165, Additional specification As directed by Engineer in charge. )
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR 2021-22, Item no.35.21, Page no.165, Additional specification As directed by Engineer in charge. )
Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration etc. Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in-charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete. (SSR 2021-22, Item no.35.29, Page no.166, Additional specification As directed by engineer incharge )
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete.(SSR 2021-22, Item no.35.23, Page no.165, Additional specification As directed by Engineer in charge. )
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R steel quality super durable polyester paint coat (with inorganicpigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anticapillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) (SSR 2021-22, Item no.38.34, Page no.302, Additional specification As directed by engineer incharge )
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) (SSR 2021-22, Item no.39.25, Page no.181, Additional specification BD-T-55 Page No.510 )
Providing and fixing partitions madeup of CCTW frame of size 75mmx50mmat60cmc/cwith9mm thick commercialply and 4mmthick veneer on both sides with French polish etc. complete.(SSR 2019-20, Item no.39.69, Page no.330, Additional specification As directed by engineer incharge)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (SSR 2019-20, I.No.40.01, P.No.338. Additional Specification Bd.U.1 Page No. 537)
Providing and fixing M.S. grill door 24 kg/sqm of various size as perdetailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc (SSR 2021-22, Item no.39.31, Page no.182, Additional specification As directed by engineer incharge)
Providing and Fixing 30 mm thick both side prelaminated solid panel PVC door shutter consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of(SSR 2021-22, Item no.39.47, Page no.186, Additional specification As directed by engineer incharge)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. (S.S.R.2021-12, I.No.39.68, P.No.331. Additional Specification As directed by Engineer incharge.)
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5 mm thick at top, 40 mm diameter and 1.5mm thick vertical supports spaced at 1.5 M center to center and 8 mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding , finishing, buffing to stainless steel pipe etc. complete.(S.S.R.2021-12, I.No.40.07, P.No.339. Additional Specification As directed by Engineer incharge.)
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars,excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (SSR 2021-22, Item no.42.09, Page no.200, Additional specification : Bd.V.41, Page No. 573.)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete (SSR 2021-22, Item no.42.12, Page no.352, Additional specification : Bd.V.43, Page No. 574.)
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (S.S.R.2021-12, I.No.42.20, P.No.353. Additional Specification As directed by Engineer incharge.)
Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SSR 2019-20, I.No.42.28, P.No.354. Additional Specification As directed by Engineer in charge.)
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc.complete. (SSR 2021-22, Item no.42.60, Page no.359, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Dismantling brickmasonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc . complet. (SSR 2021-22, Item no.46.09, Page no.377, Additional specification : As directed by engineer incharge.)
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. (SSR 2021-22, Item no.46.16, Page no.378, Additional specification : As directed by engineer incharge.)
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (SSR 2021-22, Item no.46.19, Page no.378, Additional specification : As directed by engineer incharge.)
Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them with in the specified lead as directed etc. complete. (SSR 2021-22, Item no.46.29, Page no.379, Additional specification : As directed by engineer incharge.)
Providing and fixing single leaf panelled door shutter without fanlight and shutter 35 mm thick as per drawing consisting of T.W. top rail size 100mm x 35 mm and bottom and lock rail 200mm x 35mm insert panel 12 mm thick commercial ply faced T.W. particle board with phenol formaldehyde synthetic resin (Generally confirming to ISI 3097) excluding frame, including stainless steel fixtures fastening and T.W. beading at junction of panels inserts and as instructed by the Engineer in charge including 3 coats of oil painting etc. complete. (SSR 2021-22, Item no.39.06, Page no.179, Additional specification :- As directed by engineer incharge)
Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 mm x 40 mm) weighing 0.39 kg/m at 60 cms center center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 kg/m suspended on 6 mm dia mild steel rod weighing 0.22 kg/m, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 kg/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.(SSR 2021-22, Item no.38.52, Page no.312, Additional specification As directed by engineer incharge)
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/ perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/ crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC endcaps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. (SSR 2021-22, Item no.48.47, Page no.229, Additional specification :As directed by Engineer in charge.)
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. ( SSR 2021-22, Item no.48.48, Page no.229)
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. ( SSR 2021-22, Item no.48.49, Page no.229)
Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20cm in recharge pit, in the required thickness, for all leads & lifts, all complete as per the direction of Engineer in-charge. (SSR 2021-22, Item no.48.51, Page no.230)
Supplying, filling, spreading & leveling gravels of size range 5mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer incharge. (SSR 2021-22, Item no.48.52, Page no.230)
Supplying, filling, spreading & leveling coarse fine aggregate (crushed sand VSI grade finely washed etc.) of size range 1.5mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer in charge. (SSR 2021-22, Item no.48.53, Page no.230)
chair : Furniture 51.42 Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5- prong/Nylon Base with Leather Upholstery (SSR 2021-22, Item no.51.42, Page no.466, Additional specification : As directed by engineer incharge.)
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, (SSR 2021-22, Item no.51.26, Page no.461, Additional specification : As directed by engineer incharge.)
Plumbing
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (S.S.R.2021-12, (I.No.41.74, P.No.349. Additional Specification Bd.V.30 Page No. 565.)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.82, P.No.361. Additional Specification Bd.V.30 Page No. 565.)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.79, P.No.361. Additional Specification As directed by engineer incharge. )
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.(S.S.R.2021-12, Item no.42.80, Page no.361, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (I.No.42.54, P.No.358. Additional Specification As directed by engineer incharge. )
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (S.S.R.2021-12, Item no.42.57, Page no.359, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (S.S.R.2021-12, Item no.42.59, Page no.359, Additional specification : BD.V 5 page 551 and as directed by Engineer in charge)
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.55, P.No.358. Additional Specification As directed by engineer incharge. )
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.37, P.No.355. Additional Specification As directed by engineer incharge. )
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.36, P.No.355. Additional Specification As directed by engineer incharge. )
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (I.No.42.86, P.No.362. Additional Specification As directed by engineer incharge. )
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete (S.S.R.2021-12, Item no.42.12, Page no.352, Additional specification : Bd.V.43, Page No. 574.)
Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) (Item no.42.18, Page no.352, Additional specification : Bd.V.43, Page No. 575.)
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. (Item no.42.19, Page no.352, Additional specification : Bd.V.43, Page No. 576.)
Providing and laying concrete pipes of I.S.NP. class of 150 mm diameter in proper line, level and slope including necessary collars,excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (S.S.R.2021-12, Item no.42.08, Page no.351, Additional specification : Bd.V.41, Page No. 573.)
Electrical
Supplying and erecting submersible pumpset of 3.75KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 70 to 250 LPM discharge at 87 to 48 m head & (max. efficiency at 76 m head & 160 lpm) discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification no. WP-SMP ( Electrical SSR 2021-22, Item no.12-2-10, Page no.210)
Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P ( Electrical SSR 2021-22, Item no.12-4-2, Page no.217)
Supplying & laying (including excavation) 15 cm dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).(PWD DSR 2018-19, Item no.7-6-6,,
Making trench in soft soil of suitable width and depth as per IS for laying provided L.T cable up to 25 sq mm complete. As per specification No. CW-EXN-CTR (PWD electrical SSR -2021-22 Specification no. 16-1-1)
PLANTATION WORK
GARDEN SOIL:- supplying on site garden soil well sieved 90% to pass through IS sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from qurry . The colour of the soil generally be red . the soil will be measuring box.(farma). ( item includes royalty charges, transportation ,loading unloading etc.) lead charges for 30 km is considered. (PWD Park & Garden DSR 2016-2017, I.No.2/1)
FARM YARD MANURE:- Supplying on site well decayed , well dried, well powered, without clods and free from stones, dried grass and other rubbish material. The colour of the manure generally be black . The manure will be measured by measuring box( farma). ( item includes royalty charges, transportation ,loading unloading etc.) lead charges for 30 km is considered. (PWD Park & Garden DSR 2016-2017, I.No.2/2)
PLANTING LARGE FLOWERING/ SHADY TREES:- (minimum height to 2.00 mtr.) digging pit with size 0.90x0.90x0.90 m removing and conveying unwanted stuff to a required distance as directed . Filling the pit with approved excavated material upto height of 0.30m and remaining height of 0.60m with fresh garden soil and manure in 3:1 proportion , mixing soil & manure thoroughly well , levelling as directed, watering previous night , planting two to three years old. minimum 2.0mtr height, healthy trees sapling as per specifications. maintaining till well established by watering, weeding, stirring of soil staking replacing of casualties etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.3/12)
Saplings of flowering/shadytrces Gulmohar, Raintree, Peltophorum etc (Height min. to 1 Mtr.) (PWD Park & Garden DSR 2016-2017, I.No.4/09)
Saplings of Small & medium Ornamental flowering plants , Thuja,Cupresus plants ornamental Ficus, Mussanda etc. (Height min. to 1 Mtr.) (PWD Park & Garden DSR 2016-2017, I.No.4/11)
Rose Plant :- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the fresh garden soil in minor in 3:1 proportion to a required height of 0.3 meter mixing the soil & minor levelling, watering on previous night. Planting 40 to 50 cm height healthy plant of required rose verity mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.3/09)
Mogra Plant/Creepers/Climbers:- Excavating pit with size 0.3x0.3x0.3 meter removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 15 cm. & ramming height of 15 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (1 to 2 year old) healthy plant as per specification mainaining till well established by watering weeding, sturring,prunning, replacing the casualities etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.3/10)
Planting large flowering/shady trees:- (Minimum height 1 Mtr.) Digging pit with size 0.9 x 0.9 x 0.9 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit upto excavated material upto a height 30 cm. & ramming height of 60 cm. with fresh garden soil in minor in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (1 to 2 year old) healthy trees sapling as per specification mainaining till well established by watering weeding, sturring of soil replacing of casualities etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.3/11)
Planting small & medium size ornamental flowering plant:-Digging pit with size 0.6 x 0.6 x 0.6 meter. Removing & conveying unwanted stuff of a required distance as directed filling the pit with fresh garden soil & farm yard minor upto a height of 0.6 meter in 3:1 proportion mixing the soil & minor levelling, watering on previous night. Planting (one year or two year old) healthy plant sapling as per specification mainaining till well established by watering, weeding, sturring of soil replacing of casualities etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.3/13)
Preparing instant Lawn :- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a height of 20 cm. mixing soil & minor throughly well levelling with required slope light watering on previous night, rolling on surface. Fixed readymade lawn truf rolls or slab of reqired verity as directed. ramming on it for proper fixing & mainaining till well establish by watering, weeding, clipping or moving etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.3/3)
Preparing Edging or border:- Excavating the ground to a required depth of 20 cm. removing & conveying unwanted stuff to a required distance as directed filling fresh garden soil in minor in 3:1 proportion to a required height of 20 cm. mixing , levelling , watering the same planting suitable verity of edging plants & rooted cutting at distance of 15 cm. between plants to plants and row to row watering & maintaining till well grown to te stage of prunning. (PWD Park & Garden DSR 2016-2017, I.No.3/4)
Preparing Shrubbery:- Excavating the ground to a required depth of 30 cm. removing & conveying unwanted stuff to a required distance as directed. Providing and filling fresh garden required distance as directed. Providing and filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cm. Mixing , levelling , watering on previous night. Planting well rooted shrubs 0.5 mtrs. apart as directed and maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. (PWD Park & Garden DSR 2016-2017, I.No.8/5)
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm ( 107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer.: 50 liters 2. Disinfectant. : 30 Liters 3. Sodium Hypochlorite. : 30 KG 4. Fogging machine and Liquid for sanitization.: 1 Number 5. 3 Ply Face Mask of good quality. : 500 Numbers 6. Surgical / Latex Gloves of good quality.: 200 Pairs 7. Rubber Gloves of good quality.: 100 Pairs 8. Empty Spray Bottles 100 ml (Plastic).: 20 Numbers 9. Empty Spray Bottles 1000 ml (Plastic).: 5 Numbers 10. PPE kits. : 10 Numbers 10. Temperature Guns. : 3 Numbers 11. Face shield : 30 Numbers
ELECTRO MECHANICAL WORK
THERMAL INSULATION WORK
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-60 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 50 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick)
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job.
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 1 no for each cold storage chamber.
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.
INSULATED DOORS AND DOCK SOLUTION
Staging cold room 1,2,3 Manual Sliding type 1500 mm x 2600 mm ht x 100 mm thick PIR , manual type Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
For ante-room, holding area Insulated Doors -Swing type with double shutter 2000 mm x 2100 mm ht x min 44 mm thick PIR /PUF Providing & fixing of Insulated doors (suitable for fitting on panel structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For Ripening Chambers (General details as per PART – I - INSULATED PANEL STRUCTURE AND THERMAL INSULATION of GTS) for Ripening chambers - Insulated Doors - Swing type with single leaf 1200 mm x 2000 mm ht x 80 mm thick PIR Providing & fixing of Insulated doors (suitable for fitting on panel structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated single leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 42 ± 2 Kg/m3 (insulation thicknesses as mentioned).The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
DOCK DOOR & SEAL Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. acceptable makes: Gandhi Automation/ Metaflex/Infraca/Eqvt (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK Seal : CUSHION type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations. Flexible polyurethane foam, covered with PVC / polyester fabric, supporting the vehicle pressures and perfectly sealing the three sides.
DOCK LEVELER Designed for Hydraulic operation as per General technical specification ,Acceptable makes: Gandhi Automation/ Metaflex/Infraca/Eqvt Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling etc as required for full operation to be included
Strip Curtains SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature
Staging cold room 1,2,3 Suitable for Clear opening Size: 1500mm X 2600mm ht
For Passage Area Suitable for Clear opening Size: 2000mm X 2100mm ht
For Ripening Chambers Suitable for Clear opening size: 1200 mm x 2000 mm ht
Refrigeration System for Staging cold rooms, ante-room Area
AIR COOLED CONDENSING UNITS For staging cold room 1,2,3 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room 1,2 ,3 Capacity: 13 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLED CONDENSING UNITS For Passage Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make scroll compressor working on R513A / R450A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Dock Area Capacity: 9 KW DesignTemperature: 10 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Staging cold room 1,2,3 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 13 Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 15000 External sp. Wg, mm: 5 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 8 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
AIR COOLING UNITS - Air Cooling Units for For Ante-Room Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 9 Evap. Temp. & TD ‘C’: 10 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 4800 External sp. Wg, mm: 5 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 11 m Drain pan insulation:Not Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC+weatherproof coating/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,staging cold room ACUs
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant.
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .
Miscellaneous Items a) Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc. as may be required b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. c) 2000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
Refrigeration System for Ripening Chambers & Ripening System
AIR COOLED CONDENSING UNITS For Ripening Chambers (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make scroll compressor working on R513A / R450A or other approved HFO, Air cooled condenser, Liquid receiver, Base frame for mounting, H.P. / L.P. cut outs and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Dock Area Capacity: 7 KW DesignTemperature: 10 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
SITC OF AIR COOLING UNITS - Air Cooling Units for Ripening chambers (General details as per PART – II A- REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 7 Evap. Temp. & TD ‘C’: 10°C / 4°C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 7200 External sp. Wg, mm: 4 No of Fans/Unit: 2 / 3 Fan Motor -kW each: To be Mentioned Air throw -m: 4 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Offcycle Fan peripheral heating: Not required Suitable Supporting structure from the primary support at roof level to be considered in the costing as well
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC+weatherproof coating/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 19mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support. This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. Only for pre-cooling ,staging cold room ACUs
First charge refrigeration gas and oil etc. as required upto commissioning and handling over of plant. (For Ripening chamber units)
Painting of equipment/piping etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint.
Miscellaneous Items a) Vibration isolators for Condensing units, supporting rods / Frame for A.C. Units with insulation as required etc. ( For full plant ) b) Minor structural openings in walls / panels etc for piping, cabling etc. and finishing. ( For full plant )
PART III - RIPENING SYSTEM SITC of Banana Ripening System as per the general technical specifications consisting of a) Ethylene cylinders 4 nos along with piping, solenoid valves, distribution manifold etc as may be required. b) Ethylene analyzers ( Range 0 - 500 ppm ) for 4 rooms c) Carbon- dioxide gas analizers ( sensor 0% - 5% ) for 4 rooms d) Centralised control panel for monitoring of 4 ripening rooms for control & observing parameters such as temp. , R.H. CO2 level ,Ethylene level etc. e) Temperature indicator & R. H. indicator for each Chamber The ripening system shall be PLC based fully automatic & suitable have the facility to start ripening process in a given room for a fixed time interval & fixed concentration inside the room.The system should have the facility to start ripening process in a given room for a fixed time interval & fixed concentration. The Ethylene & carbon di-oxide gas analyzer monitoring system should have LED display ,built in Ethylene & CO2 sensors.It should analyze & display the ethylene concentration in ppm level ( 0 to 500 ppm ) & CO2 level in 1 % ( 0.01 % to 5 % ) with alarm out puts, analogue outputs. Ethylene sensors will regulate the operation of the cylinders automatically. This system also should control ventilation system as well. Necessary quantity of ethylene solution to achieve 50 cycles of ripening process in each banana ripening store to be included in the cost.
SITC of Ventilation System design to supply fresh air & extract & CO2 laden air with motorised dampers, with exhaust & supply fans ,piping, fittings, timers & controls, power& control wiring etc for all 4 chambers
Humidification system for chamber complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks/ point of supply to humidifier unit, fitting ,valves,solenoid valves with strainers and humidity indicator cum controller etc. to maintain the relative humidity in the design range. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel Humidifier Capacity: 3 Lit/hr.
Charges for Installation, Testing and Commissioning Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
VENTILATION SYSTEM -
- Air Curtains for staging cold room Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1500 mm x 2600 mm ht
Air Curtains for Ante-room , holding area Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 2000 mm x 2100 mm ht
Air Curtains for Ripening Chambers Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: approx. :1200 mm x 2000 mm ht
Miscllanious Items
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance.
Miscellaneous Items : Insect Killer, Stainless Steel Body 304 with stainless steel screws and stainless steel grills with glue board, suitable mounting arrangment. Confirming to CGMP & food safety standards.
Miscellaneous Items : Packing Tables with S.S. tops& SS legs size 2400 x 1200 Size - 1800 x 900
Miscellaneous Items : Lab Equipments of reputed makes a) Temprature Probes to measure temprature of the fruit - 6 nos b) Refractometer to check the total soluble solids - 2 no. c) Calipers to measure size of the fruit - 4 no. d) Differntial Colour Charts to Check Colour of the fruit - 2 no. e) Penetrometer to measure Pulp pressure - 2 no. f) pH measuring probe to measure pH - 2 no. g) Microscope with camera feature - 2 no. h) other related equipments as may be required i) illuminated magnifier- 1 no
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Electrical installation
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode
Supply, Installation, Testing and commissioning of UL Certified / CPRI Tested Maintenance Free Earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron Molecular Copper Bonded Earthing Rod of Length 3m along with 25 kg Carbon Based environment friendly back fill Ground Enhancing compound required to fill up the excavated earth with required quantity as per specification no EA-MOBI (PWD electrical SSR -2021-22 Specification no. 9-1-5)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP). (PWD electrical SSR -2021-22 Specification no. 9-2-3)
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required.As per specification no. EA-EP(PWD electrical SSR -2021-22 Specification no. 9-2-2)
Supplying & laying (including excavation) 15 cm dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet). (PWD electrical SSR -2021-22 Specification no. 7-6-6)
Supplying & laying (including excavation) 15 cm dia RCC Hume pipe with coupling collar of standard thickness at required depth up to 90 cm below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).(PWD electrical SSR -2021-22 Specification no. 7-6-5)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(Except bitumen carpet).(PWD electrical SSR -2021-22 Specification no. 7-6-13)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(PWD electrical SSR -2021-22 Specification no. 7-6-9)
Liaisoning Work for Increase of Existing Sanctioned load from Electricity board & Electrical inspector or any other government authority for sanction of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned, Obtaining work completion report from Electrical inspector & board officials. Successfully charging of entire installation. Client (Owner) will make all official payments as per the requirement of Electricity board.
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.(PWD electrical SSR -2021-22 Specification no. 10-2-22)
Providing Round bottom fire bucket of 9 Litres capacity as per IS :2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.(PWD electrical SSR -2021-22 Specification no. 10-2-24)
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.(PWD electrical SSR -2021-22 Specification no. 10-2-25)
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.(PWD electrical SSR -2021-12 Specification no. 10-2-26)
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.(PWD electrical SSR -2021-12 Specification no. 10-2-23)
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)(PWD electrical SSR -2021-22 Specification no. 10-2-27)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV(PWD electrical SSR -2021-22 Specification no. 10-2-28)
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.(PWD electrical SSR -2021-22 Specification no. 10-2-32)
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.(PWD electrical SSR -2021-22 Specification no. 10-2-36)
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(PWD electrical SSR -2021-22 Specification no. 7-1-19)
Supplying, erecting & terminating XLPE armoured cable 1100 V. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (PWD electrical SSR -2021-22 Specification no. 7-1-22)
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(PWD electrical SSR -2021-22 Specification no. 7-2-32)
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(PWD electrical SSR -2021-22 Specification no. 7-2-31)
Supplying, erecting & terminating XLPE armoured cable 3 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(PWD electrical SSR -2021-22 Specification no. 7-2-16)
Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(PWD electrical SSR -2021-22 Specification no. 7-2-14)
Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(PWD electrical SSR -2021-22 Specification no. 7-2-8)
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV(PWD electrical SSR -2021-22 Specification no. 1-3-28)
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.(PWD electrical SSR -2021-22 Specification no. 7-11-8)
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.(PWD electrical SSR -2021-22 Specification no. 7-11-7)
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner..(PWD electrical SSR -2021-22 Specification no. 7-11-13)
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware in approved manner.(PWD electrical SSR -2021-22 Specification no. 7-11-12)
Supply, Installation, Testing & Commissioning of conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on 5 meters height, The Lightning protection includes the Lightning counter comprising of digital display in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA counter & it should be tested as per IS/IEC, The Job also includes supporting mast using Galvanized Iron pipe of 3 meter length plus 2 meter pipe of FRP complete with base plate, Guy rope wires, Insulator, Clamps, Fasteners, Fan Hooks, hardware, etc. (PWD electrical SSR -2021-22 Specification no. 9-3-1)
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW(PWD electrical SSR -2021-22 Specification no. 1-9-9)
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW(PWD electrical SSR -2021-22 Specification no. 1-9-22)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background(PWD electrical SSR -2021-22 Specification no. 1-8-36)
Supplying and erecting modular type electronic step regulator for fan two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. (PWD electrical SSR -2021-22 Specification no 1-8-23)
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessoriesas per specification No: WG-PW/CW (PWD electrical SSR -2021-22 Specification no.1-9-14)
Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WG-PW/SW(PWD electrical SSR -2021-22 Specification no. 1-9-11)
Supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20mm dia. as per specification No: WG-MA/PC(PWD electrical SSR -2021-22 Specification no. 1-6-4)
Supplying and erecting ISI mark modular type switch 16 / 20A with indicator, duly erected on provided plate and box with wiring connections complete. (PWD electrical SSR -2021-22 Specification no.1-8-6 )
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. (PWD electrical SSR -2021-22 Specification no.1-8-11 )
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background(PWD electrical SSR -2021-22 Specification no. 1-8-36)
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW(PWD electrical SSR -2021-22 Specification no. 1-9-9)
Supplying and erecting ISI mark modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete(PWD electrical SSR -2021-22 Specification no. 1-8-19)
Point wiring for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as per specification No: WG?PW/SW(PWD electrical SSR -2021-22 Specification no.1-9-1)
Supplying and erecting modular type telephone socket one gang with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. (PWD electrical SSR -2021-22 Specification no.1-8-15)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement morter / POP as per required to match the background in an approved manner. (PWD electrical SSR -2021-22 Specification no.1-8-35)
Supplying and erecting modular type T.V. socket single outlet ISI mark approved make duly erected on provided plate and box with wiring connections complete. (PWD electrical DSR -2021-22 Specification no.1-8-14)
Supplying and erecting modular type computer Jack RJ 45 with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. (PWD electrical SSR -2021-22 Specification no 1-8-17)
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (PWD electrical SSR -2021-12 Specification no. 1-1-9 )
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.(PWD electrical SSR -2021-22 Specification no. 1-1-11)
Supplying and erecting UPVC reinforced flexible conduit 25 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.(PWD electrical SSR -2021-22 Specification no. 1-2-2)
Supplying and erecting UPVC reinforced flexible conduit 31/32 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.(PWD electrical SSR -2021-22 Specification no. 1-2-3)
Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG?MA/BW(PWD electrical SSR -2021-22 Specification no. 1-3-4)
Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(PWD electrical SSR -2021-12 Specification no. 1-3-2)
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG?MA/BW(PWD electrical SSR -2021-12 Specification no. 1-3-6)
Supplying & erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG?MA/BW(PWD electrical SSR -2021-12 Specification no. 1-3-8)
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG?MA/BW(PWD electrical SSR -2021-12 Specification no. 1-3-6)
Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG?MA/BW(PWD electrical SSR -2021-22 Specification no. 1-3-4)
Supplying & erecting telephone cable 2 pair with 0.5 mm dia. laid in provided PVC casing / conduit asper specification No. WG-TW (PWD electrical SSR -2021-22 Specification no.1-10-1)
Supplying & erecting jelly filled armoured telephone copper cable 20 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW(PWD electrical SSR -2021-22 Specification no. 1-10-14)
Supplying, erecting & commissioning junction box suitable for 10 pairs as per specification No. WG-TW(PWD electrical SSR -2021-22 Specification no. 1-11-12)
Supplying & installing Co-axial cable low voltage grade RG-11 as per specification No. WG-TW (PWD electrical SSR -2021-22 Specification no.1-10-18)
Supplying & installing UTP networking Cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC (PWD electrical SSR -2021-22 Specification no.1-12-1)
Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG?MA/BOX .(PWD electrical SSR -2021-22 Specification no. 1-2-17)
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire..(PWD electrical SSR -2021-22 Specification no. 2-13-6)
Providing, erecting & commissioning RCCB only of electro magnetic type with 30/100/300 mA sensitivity and having capacity of 16/25 A. 2 pole complete as per specification No. SW-RCCB/RCCB (PWD electrical SSR -2021-22 Specification no. 5-6-1)
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB(PWD electrical SSR -2021-12 Specification no. 5-3-2)
Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB(PWD electrical SSR -2021-22 Specification no. 5-3-16)
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP /TP MCBs of 24 poles/ 8 ways on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB (PWD electrical SSR -2021-22 Specification no. 5-4-11)
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 6 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SWSWR/ MCBDB (PWD electrical SSR -2021-22 Specification no. 5-4-18)
Supplying, fixing and commissioning 2 pole,RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SW-RCCB/RCBO(PWD electrical SSR -2021-12 Specification no. 5-6-11)
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB(PWD electrical SSR -2021-12 Specification no. 5-3-2)
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complet (PWD electrical SSR -2021-22 Specification no. 5-4-23)
Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB(PWD electrical SSR -2021-12 Specification no. 5-3-6)
Supplying & erecting On line UPS pure sine wave of 5 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification No. AP-UPS (PWD electrical SSR -2021-22 Specification no. 3-7-4)
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 4way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supplying and erecting LED square / circular 13 to 15W downlighterhaving pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. (PWD electrical SSR -2021-22 Specification no.2-1-4)
Supplying and erecting LED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type(PWD electrical SSR -2021-22 Specification no.2-1-2)
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 5700/6000K)direct fitting LED bulbs.
Supplying and erecting LED street light fitting suitable for above 70W- 75W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS2(PWD electrical SSR -2021-22 Specification no.2-5-6)
Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC(PWD electrical SSR -2021-22 Specification no.2-9-1)
Supplying and erecting 40W LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 protection on provided pole/ bracket.(PWD electrical SSR -2021-22 Specification no.2-5-26)
Supplying and erecting Five Star Rated Energy Saving Ceiling Fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specifcation no. FG-FN/CF (PWD electrical SSR -2021-22 Specification no.2-12-21)
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.- cfm for ventilation fans is 425 (±10%)
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 1470 (±10%)
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.- cfm for ventilation fans is 2650 (±10%)
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 8 points Annunciator - 1 No Stay-put type push buttons. - 8 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 Mtrs 10Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 150 Mtrs Junction box - 10 pair connection Medium duty PVC conduit of 25 mm size with standard accessories. - 100 Mtrs
Overhauling of Machineries for 1 precooling chamber, 2 cold rooms ,conveyors etc as per the scope given below. It is recommended that bidder shall visit the site and get the idea of quantom of work before quoting.
Scope of Work for Refrigeration System: • Checking of operational log readings recorded by operators during the previous month.& Discussion operational problems, if any, with maintenance/operation staff. • Checking the actual performance of the machines and Checking & correcting the set parameters, if required. • Carrying out minor repairs. Replace parts ,if required. • Making recommendations to client for smooth & trouble free operation of the machines. • Cleaning & combing of ACU’s fins, suction filters, driers, pump ,strainers etc. • To check oil level in the compressor, if less then oil to be charged in to the compressor. • Check liquid sight glass to determine the shortage of refrigerant if any / to check moisture contained in the system. Top up if required. • Inspect system for visible signs of leaks. If found, attend the leaks. If any brazing work involved should be carried out by the contractor at his cost • Inspect & adjust, if required, all safety controls. • carrying out calibration of gauges, temperature , RH sensors etc, wherever caliberation time frame has exceeded • Inspect the condition of refrigerant and drain pipe insulation (drain pipe insulation wherever applicable).To be replaced if found not in good condition. Scope of Work for Insulated Sandwich Panels: • Insulated Panel Structure: Filling of silicon sealant as & where required to stop air leakages if any. • Floor Insulation – checking for gaps created between civil floor and wall insulation and sealing the same with silicon sealant / PUF filling depending on the size of the gap, if created during regular wear and tear or minor damage. • PUF foaming in case condensation due to leakage etc found.
Scope of Work for Insulated Doors, Strip and Air curtains: • Cleaning and oiling of rollers of doors • Gasket checking for leakage. Alignment of gasket if leakage is observed. • Replacement of gasket if gasket is damaged or found in improper condition. • P.V.C. strip Curtains: Replacement of PVC strips if any. • Air Curtains – check the overall condition. Replacement of blower/limit switch /full uUnit,as the case may be to ensure proper operation Scope of work for Electrical System: If anything mentioned below found not normal, same shall be rectified • Check for loose connection of all terminals in the panels. • Clean gently the dust by air pressure in side the panels. • Check the mounting of CTs for its position, ensure that does not make contact with body. • Check for loose connections for all power / neutral cable connections. • Check for all the fuses. • Check for loose connections of all power cables & control cables of panel. • Check for loose connections of cables of meters / contractors. • Check the outgoing & incoming phase, neutral connection of circuit breaker. • Check the thermal trip of circuit breaker. • Check mountings of circuit breaker & tightness of power cables. .
DG set B check with necessary serving changing of filter, oils, Lubricants etc. complete. And with required battery for DG set.
Dyna Filters Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .