Loading…
Loading…
Tender Value
₹40.6 L
EMD Value
₹81,200
Closing Date
5 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
TELE JAT
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIIB of Northern Railway Standard Tender Document 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
(a) The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (i) In case of tender for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges- substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated /registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender
64 conditions · 29 needing a document upload
1. Tender fee (if asked) need to be deposited online on www.ireps.gov.in. 2. EMD need to be deposited online on www.ireps.gov.in. 3. For the tenders costing above 50 Lacs: Details of "total contractual payments" in the previous three financial years. 4. For the tender costing above 50 Lacs: Details of technical credentials have successfully completed or substantially completed similar nature work as mentioned in tender condition. Completion certificate issued by competent authority should mandatorily mention Name of work, name of agency, Contract agreement number, date of completion/date of completion of substantially completed work, Completed Cost/substantially completed cost of work, Nature of firm (Partnership/Proprietorship etc.) and details of its constituents, if any, PAN/GSTIN etc. so that evaluation may be done accordingly. 5. If Tenderer is sole proprietor: Notarized copy of Affidavit on Stamp paper of appropriate value declaring that his/her concern is a Proprietary concern. 6. If Tenderer is Partnership firm: Self attested copy of (i) Registered/Notarized partnership deed (ii) Original/Notarized power of attorney. 7. If Tenderer is JV/Limited Company: Copy of Memorandum and Articles of Association of the company. Power of Attorney (duly registered/notarized as per prevailing law) by the company authorizing the person to do/act on behalf of the company. 8. If Tenderer is Company: Copies of MOA (Memorandum of Association) & AOA (Articles of Association) of the company. Power of attorney duly registered/notarized by the company in favour of the individual signing the tender on behalf of the company. Resolution of Board of directors in regards of approving Power of attorney issued. 9. If Tenderer is Society: Attested copy of the certificate of registration. Deed of formation. Power of attorney in favor of the tender signatory.10. Copy of PAN number and TIN number.
Please submit the copy of the registration certificate of firm, PAN, GSTIN etc.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please submit the copy of the registration certificate of firm, PAN, GSTIN etc.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Signal & Telecom(S&T) rehabilitation works required in the PTK-SVDK section for GM inspection over the Jammu Division.
433_TELE_JAT_19_25-26~NR
433_TELE_JAT_19_25-26
Open
Works - General
60 Days
Jammu, Jammu And Kashmir
₹0
₹81,200
5 Jan 2026
12 Dec 2025
22 Dec 2025
55 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 40,59,858.3 | ||
| — | 4.00 | — | — | ||
| Excavation of trench (manual or using JCB), careful shifting and relaying of cable, providing protection (sand cushioning, tiles/HDPE pipe/stone slabs as required), backfilling with proper compaction, and reinstatement of route, including all tools, labour, and materials, complete in all respect as per Railway Representative at Site. | — | — | — | 4,06,972.68 | |
| — | 60.00 | — | — | ||
| Repairing & Protection of existing underground telecom cable. The work involves complete repairing and protection of the existing underground telecom cable, including carrying out Emergency Joints/Derivation Joints and Straight Joints as required at emergency sockets, block sections, and at locations where existing joints are found damaged or defective. Emergency joints shall be made using required jointing kits(not Straight joint kits) as per Technical specification attached , which shall be arranged and supplied by the contractor. Straight joint kits required for permanent restoration shall be provided by the Railways. All jointing work shall be executed by team consisting of one skilled cable jointers and two helpers, equipped with the necessary tools, testing instruments and safety gear to ensure reliable and durable restoration of the cable. As per Railway Representative at Site. | — | — | — | 3,24,000 | |
| — | 2.00 | — | — | ||
| Deploying maintenance team consist of one skilled (Cable jointer) and three un- skilled at designated location which will do technical audit/preventive maintenance periodically and also will involve in any cable fault rectification and in which if any trenching and laying involved for item no. 1 will be done. (This item consist of One team for 3 Months ). | — | — | — | 3,21,104 | |
| — | 17.00 | — | — | ||
| Telecom wiring in ASM Room and OFC Room for operational facilities, including drawing and fixing of jelly-filled twisted pair cable in duct/indoor telephone cable, termination on Krone-type MDF/IDF blocks, connection of operational circuits between ASM equipment, control telephones, PA system, and MUX, dressing of cables with numbering ferrules, and proper clamping/concealing with PVC casing-capping/conduits. Work includes wiring between MUX and U- Link panel, complete with testing and labeling. This also includes Wiring of VHF Antenna System, including installation of GP Antenna on mast or rooftop, routing and fixing of VHF feeder cable from antenna mast to VHF base station, laying of feeder cable through PVC/GI conduit pipe in exposed areas and at wall or roof entries for mechanical protection, clamping along mast/wall using suitable cable ties and saddles. Includes connection of feeder cable to transceiver equipment, testing of VSWR and signal strength, and releasing/removal of old faulty cable.All items required like - ferrules,clamps,conduits,cable ties,labels and any other associated items shall be supplied by the contractor.All work shall be completed as per Telecom Manual and instructions of Site supervisor . | — | — | — | 42,500 | |
| — | 10.00 | — | — | ||
| Supply of GP Antenna.This vertically polarized antenna operates within the 134-174 MHz frequency range, offering a bandwidth of 4% of the specified center frequency and a 50-ohm impedance with VSWR less than 1.5. It delivers a gain of 0 dBd (2.1 dBi) and supports a maximum input power of 200 W. Constructed from aluminium alloy with a chrome finish, it stands approximately 100 cm tall (at 160 MHz), weighs 1.0 kg, and is designed for mounting on a 38 mm diameter pole (not supplied), typically installed on towers. The unit features a UHFfemale connector, ensures IP66 ingress protection, and operates reliably across a temperature range of -40°C to +70°C. (INSPECTION BY CONSIGNEE) | — | — | — | 50,000 | |
| — | 10.00 | — | — | ||
| Supply of 30 m long VHF Feeder Cable RG-217, 50 , suitable for interconnection between 25 W VHF set and outdoor GP antenna, constructed with stranded copper inner conductor, solid PE dielectric, copper tape + braid shielding (90% coverage), attenuation approx. 2.4 dB/100 m @ 50 MHz, velocity factor 66%, factory-fitted N-type (M-M) connectors with VSWR 1.3 in VHF band, provided with flame-resistant PVC outer jacket suitable for outdoor installation.( MUST HAVE TEST CERTIFICATE ). (INSPECTION BY CONSIGNEE) | — | — | — | 74,930 | |
| — | 10.00 | — | — | ||
| Supply of Maintenance-Free (SMF) Battery 12V, 100AH for VHF equipment. specs as per Telecom Manual and Engineer's instructions.(INSPECTION BY CONSIGNEE) | — | — | — | 87,838.8 | |
| — | 10.00 | — | — | ||
| Supply , Installation, testing, and commissioning of Float-cum-Boost Charger / Power Supply Unit for Maintenance-Free (SMF) with Battery 12V, 100AH with , interconnection wiring, labeling, terminal protection, and integration with VHF equipment. Complete as per Telecom Manual and Engineer's instructions. (INSPECTION BY CONSIGNEE) | — | — | — | 16,402 | |
| — | 100.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6 scattered at different places for items not covered in above schedule. Volume of foundation also includes volume of C.I. base, anchor bolts. Coarse sand, aggregate 25mm and cement to be supplied by contractor. | — | — | — | 2,86,488 | |
| — | 30.00 | — | — | ||
| "SUPERVISION: QUAD/OFC Cable parameter testing mobile platform for testing characteristics of OFC Cable, splicing, OFC Terminal Equipment, Cable Joints, EMC sockets etc. The Mobile Platform will carry sophisticated measuring instruments and electronic gadgets to be made available by Railway .All other materials, maintenance and accessories along with required manpower to be supplied by the contractor.If required two numbers of Mobile platforms to be provided keeping the parameters same or as instructed by Site-In-Charge. (i) Charges per day as per the log book entry." | — | — | — | 49,978.5 | |
| — | 130.00 | — | — | ||
| Supply of Emergency socket box as per RDSO Drg. No.TCA-20060(ADV).(INSPECTION BY RITES) | — | — | — | 5,44,898.9 | |
| — | 130.00 | — | — | ||
| Supply of 6 pin Emergency socket as per RDSO specification IRS: TC-42/2020 Version:1.1. (INSPECTION BY CONSIGNEE) | — | — | — | 34,095.1 | |
| — | 16.00 | — | — | ||
| Supply of V F Transformers (1 Quad/2T) As Per RDSO specification IRS:TC 76/2000 with Amendment No.1. (INSPECTION BY CONSIGNEE). | — | — | — | 20,697.6 | |
| — | 10.00 | — | — | ||
| Supply of True RMS Digital Multimeter, 4000 Count, Voltage: 1000V AC/DC.Make/ Model : Fluke 17B+, DI-LOG 9206,Meco or similar or better. Inspection by consignee. | — | — | — | 1,05,933 | |
| — | 13.00 | — | — | ||
| Supply of MaintenanceTool kit : Each kit consists of item No. 1 to 13 as per list below: - i) Spanner D/E 30x32 mm =1 No. ii) Spanner D/E 18x19 mm =1 No. iii) Spanner combination Ring and open end 19 mm = 1 No. iv) Spanner open end 50 mm = 2 Nos. v) Spanner combination ring & open end 30 mm = 01 No. vi) Spanner combination ring & open end 40 mm = 02 No. vii) handle extension = 01 No. viii) Lhandle = 01 No. ix) Box Spanner 30 & 19 mm = 01 Nos. x) Cutter cum stripper 4" = 01 No. xi) Screw driver 6" = 02 Nos. xii) Adjustable wrench 375 mm = 01 No. xiii) Hammer ball 1.5 lb = 01 Nos. (Inspection: Consignee) | — | — | — | 1,54,961.3 | |
| — | 7.00 | — | — | ||
| Supply of Digital AC/DC low current Clamp meter model Metravi Digital AC/DC Leakage Current Clamp Meter 17mm Blue & Black,4673 or similar or better.( Inspection by Consignee). | — | — | — | 53,950.19 | |
| — | 1000.00 | — | — | ||
| Supply of Reflective Tape Yellow :- Highlighter grade retro reflective tape is made of non metelised polycarbonate micro primatice visible from 1000 meters highly durable ASI 90 specified reflection value will not detroinate as sure clean application and endures protection against seepage and dirt are to confirm compliance to ASI 90 size per four feet width in roll make EGP/ NBL/3M & AVERY or similar or better. Inspection by Consignee. | — | — | — | 4,86,960 | |
| — | 140.00 | — | — | ||
| Composing ,Printing & Binding of different types of registers and history cards which consistist of 1. Point Crossing joint inspection register consisting of at least 100 pages.- 1 nos. 2. TWS point & Crossing Joint Register consisting at least 100 pages-o1 No's. 3. Rolling Block resister consisting of at least 100 gages-o1 No's 4. Battery Maintenance Register consisting of at least 100 pages--1 nos. 5. Axel Counter Register consisting of at least 100 pages- 1 nos. 6. Block Instrument Register consisting of at least 100 pages- 1nos. 7.Lifting Barrier Register consisting of at least 100 pages- 01 nos. 8. BPAC Register consisting of at least 100 pages- 1nos. 9. Cable Testing Register (SPIRAL) consisting of at least 100 pages-- 1nos. 10. Track Circuit Register consisting of at least 100 pages- 01 nos. 11. Earth Testing Registerconsisting of at least 100 pages.- 01 nos. 10. 12.Signal history Card (size A4).-10 nos. , 13.Printing of Motor Point history Card (size A4).- 12 nos. 14 Track Circuit history Card (FEED END) (size A4)-- 30nos. 15.Printing of Track Circuit historyCard (Relay END) (size A4).- 30 nos. 16. SSDAC Track History Card (size A4)- 04 nos. " 16. EI maintenance resister consisting of at least 100 gages - 01 No's | — | — | — | 4,75,344.8 | |
| — | 200.00 | — | — | ||
| Supply of Plastic cover for 2 Aspect signal unit cover is opened from front side and bottom side and made of black polythene sheet of 100 micron thickness size 1200mm x 46mm x 205mm on back side 75mm wide corner to corner diagonal cross mark of silver of 100 micron thickness to be provided to the up cover with signal unit suitable to nylon rope of 5mm dia and 4mtrs length to be provided on front side and of 1.5mtr. length at center. Inspection by Consignee | — | — | — | 12,574 | |
| — | 100.00 | — | — | ||
| Supply of 3 aspect weather proof Rain Protection Signal Covers made with Polyolefin, polythin sheet avg random thickness 200 microns or more and the sheet processed with CX slurry polymerization to meet good rigidity, less draw down and malleability stress crack resistance and suitable to fix at rear side of the 3 aspect IPS unit duly provided with pre-stitched gripping elastic on the edge of the cover with suitable lacing rope of good quality to bind the cover over the base. For Aspect signal Unit size: 150 cm x 45 cm x 23 cm. With on back side 75 mm wide cross mark of silver colors of 100micron thickness to provided on Back with good quality adhesive (pressure sensitive adhesives) used in Duct tape or better . (Inspection by Consignee). | — | — | — | 24,496 | |
| — | 30.00 | — | — | ||
| Supply of 4 aspect weather proof Rain Protection Signal Covers made with Polyolefin, polythin sheet avg random thickness 200 microns or more and the sheet processed with CX slurry polymerization to meet good rigidity, less draw down and malleability stress crack resistance and suitable to fix at rear side of the 4 aspect IPS unit duly provided with pre-stitched gripping elastic on the edge of the cover with suitable lacing rope of good quality to bind the cover over the base. For 4 Aspect signal Unit size: 200 cm x 45 cm x 23 cm. With on back side 75 mm wide cross mark of silver colors of 100micron thickness to provided on Back with good quality adhesive (pressure sensitive adhesives) used in Duct tape or better . NOTE: One sample to be got approved by consignee before bulk supply.iNSPECTION: CONSIGNEE | — | — | — | 7,752.6 | |
| — | 200.00 | — | — | ||
| Supply of Points william stretcher bar insulation complete set as per RDSO Drg. No. SA 9151-52 or latest with latest amendments complete with nut bolts etc.INSPECTION BY CONSIGNEE | — | — | — | 60,454 | |
| — | 120.00 | — | — | ||
| Engagging mechanical excavators like JCB or other machinaries for regrading & leveling the formation, dismantling any infringing structures, cleaning & removing debris etc. with all lead & lift etc complete as per instructions of Rly representative at site. (Inspection: consignee) | — | — | — | 1,16,484 | |
| — | 10000.00 | — | — | ||
| Charging of secondary cell (with contractors own charging equipment) as per standard charging procedure. Two number of charged/discharged cycles should take place as per standard practice. All the charging materials including sulphuric acid conforming to latest IRS spec. and battery grade distilled water conforming to latest IRS spec. will be supplied by the contractor. (Inspection:Consignee) | — | — | — | 26,000 | |
| — | 20.00 | — | — | ||
| Supply of Micro Controlle based Light weight High Lumen LED Torch light as per technical specification attached.(INSPECTION BY CONSIGNEE) | — | — | — | 29,122.4 | |
| — | 1.00 | — | — | ||
| Supply and Installation of Demineralizer plant of aquaguard make or similarcapacity 65 Litres per hour approx. This includes all the pipe connections from water source to unit and also to collection unit. (Inspection:Engg representative) | — | — | — | 35,920.43 | |
| — | 1500.00 | — | — | ||
| Protection, rehanging, and fixing of existing telecom cable on girder and concrete bridges, including removal of old/damaged clamps, providing and fixing new galvanized mild steel (MS) clamps, saddles, GI wire, or PVC spacers as required; alignment and securing of cable along bridge structure; applying protective paint on clamps; ensuring mechanical safety and uniform spacing; complete in all respect as per site requirement and instructions of Railway Representative at Site. | — | — | — | 2,10,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .