This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | |||||
| 1.02 | Make:- Legrand (Myrius)/ Schneider(Livia)/Anchor Roma (Plus) | - | - | - | - |
| 1.03 | Group C. | 121 | Per point | 1,202 | ₹1,45,442 |
| 2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Make:- KEI/Anchar/ Finolex | |||||
| 2.01 | 2x2.5 Sq. mm. | 180 | Per metre | 249 | ₹44,820 |
| 2.02 | 2x4.0 Sq. mm. | 390 | Per metre | 311 | ₹1,21,290 |
| 2.03 | 2x10.0 Sq. mm. | 48 | Per metre | 571 | ₹27,408 |
| 3 | Wiring for circuit / sub-main with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. (4X4+2X4)HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI/Anchar/Finolex | 250 | Per metre | 524 | ₹1,31,000 |
| 4 | Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI/Anchar/Finolex | 7 | Per metre | 1,045 | ₹7,315 |
| 5Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.Make:- KEI/Anchar/Finolex | |||||
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_199450.xls
BOQ • 0.36 MB
Churrah.pdf
Tender Documents • 4.04 MB
DECLARATION.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .