Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹18.2 L+₹1.6 L (9.74%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹18.4 L+₹1.8 L (10.5%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹19.3 L+₹2.7 L (16.1%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹20.8 L+₹4.2 L (25.1%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
₹22.8 L
EMD Value
₹45,600
Closing Date
23 Dec 2019, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPL REPAIRS TO COVERED SHED (BLDG NO P-23 AND P-24) AND TOILETS (BLDG NO P-28) AT SUKHI SEWANIA FIRING RANGE BHOPAL
2019_MES_233397_1
83401
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE BHOPAL
₹45,600
Yes
1 Feb 2020
29 Nov 2019
30 Dec 2019
29 Nov 2019
23 Dec 2019
13 Dec 2019
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories).
Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in section in unframed work.
Cutting holes in brick walls exc half brick but not exc one brick in cement mortar ore cement lime mortor for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) Type B-1 as required as specified and directed
Cutting chase, pinning in making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landing etc complete all specified and directed.
S&F MS rolled section/tubular sections in purling , cross, beam, rafter,posts etc. incl connected cleats, hold fasts etc of grade conforming to Fe 410-O or Fe 310-O complete all as specified and direcetd. Note: Weight shall be verified by the GE.
S&F MS wind ties for roof truss including necessary drilling bolting as riveting etc and similar work to FE 410-S or FE 310-S complete all as specified and direcetd. Note: Weight shall be verified by the GE.
S&F pre-painted galvatume aluminium zinc coating GI based corrrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self-tapping screws on angle iron frame of each side as directed by Engr-in-Charge. Make: Tata blue scope / Everest industries/ Jindal.
Ditto all as per Ser item No. 10.00 above but plain sheet. Make: Tata blue scope / Everest industries / Jindal.
Dismantling wall and ceiling boards, fiber, pulp, insulation, etc. of any description fixed in any position, any thickness including cover fillets.
S&F galvanised cold rolled steel section framed work size 600x600 mm grid size 24x38x0.30 mm Tee (bottom precoated) and 24x24x0.30 mm thick wall angle galvanised cold rolled steel section incl expansions fasteners as in ceiling.
S&F 6 mm thick Asbestos free calcium silicate board of size 600mmx600mm fixed to frame of galvanised cold rolled steel frame work as in ceiling including applying two coats of oil bound distemper over a coat of primer all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete.
M&L for coloured joint free Non Skid ceramic tiles 7 to 8 mm thick (square/rectangular) are of each tile exc 0.11 Sqm but n.exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & incl 15 mm thick screed bed or bedding layer with CM (1:6) complete all as specified and directed.
M&L for Hand cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing complete incl 15mm thick screed bed or bedding layer with CM (1:6) complete all as specified and directed.
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto
M&L for Glazed ceramic concept tiles (approved design/pattern with highligher tiles)of size not less than 300x450x7mm in vertical surfaces such as dados,etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement mortar (1:4) complete all as specified and directed.
M&L for Endura joint free colour tiles 8 to 10 mm thick (square/rectangular) area of each tiles not exceeding 0.11 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer with CM (1:4) all as specified and directed.
Taking down shutters of any descripition n exc 1.00 Sqm each.
Taking down shutters of any descripition exc 1.00 Sqm and n exc 2.00 Sqm each.
Taking down chowkhats or frames with shutters ( with taking of shutters from the frames) n exc 1.50 Sqm each.
Taking down chowkhats or frames with shutter exc 1.50 Sqm but n exc 4 Sqm with shutters (without taking off shutters from the frame)
S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
S&F Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.
S&F 2nd class HW factory made 35 mm thick plain framed, panneled shutter (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats complete all as specified and directed.
S&F 2nd class HW factory made 35 mm thick glazed and skelton shutter, open rebated and prepared to receive glass, gauges, etc ( with or without sash bars) , edges of framing plain, chamfered or rounded, fitted with cut and mitreated beads for securing glass, etc fixed to chowkats all as specified and directed.
Ditto all as per Ser item No 28.00 above but 30 mm thick for window / ventilators complete all as specified and directed.
S&F Composite type steel windows (Wiremesh & Glazed type) with side hung shutters including Box type hinges with steel handle, and steel peg stay, complete with one shutter glazedbar and other shutter without glazing bars, dovetailed or welded.
S&F Solid PVC Door frame of Size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S squre tube,supplying &fixing in opening as per specification & drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail: paneling of plain colour PVC sheet to be fitted in the Aluminium frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement suppling and fixing the frame at site as per specification and drawing including 2.00 Nos aluminium tower bolts 150 mm long, 2.00 Nos aluminium anodized handles 150 mm size and 3.00 Nos MS butt hinges 100mm size fixed on each shutter.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr in charge.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed by engr in charge.
S&F 150 mm long aluminium handles, cast type, anodised fixed to shutters, complete all as specified and directed by Engr in charge.
S&F 100mm size butt hinges medium weight cold rolled mild steel, complete all as specified and directed.
S&F Powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleats, screws sash fasteners, plug for fixing with wall, columns etc complete all as specified and directed. Note: Weight shall be verified by the GE.
S&F Tinted glass 4.80 mm thick in glazing to aluminium door, window & partition incl pad/gasket complete all as specified and directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty/wooden bead in squares n exc 0.50 Sqm in each pane all as specified and directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 150mm length door stopper of aluminium alloy body and tongue, powder coated, with hard drawn steel spring fixed with doors complete all as specified and directed.
S&F in repair Aluminium (extruded section body) door closer hydraulically regualted, designation No 3.00 universal type, suitable for door shuttes of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by engr in charge.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
S&F PVC(SWR) pipes 110 mm bore single socketed in any length with rubber rings joints fixed to walls with clamps and brackets complete as specified and directed.
S&F PVC (SWR) pipe bend of 75 mm bore.
S&F PVC (SWR) pipe bend of 110mm bore.
S&F PVC (SWR) junction single, (SingleT) equal or unequal of 75 mm bore.
S&F PVC (SWR) junction single, (SingleT) equal or unequal of 110 mm bore.
S&F 110 mm PVC(SWR) vent cowl.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and directed.
M&L for Brick work with sub class 'B' Brick (modular brick) straight or curved on plan exc 6 m mean radius built in CM (1:6), complete all as specified and directed by Engr in Charge.
M&L for Brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls build in CM (1:4), complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM (1:6) and to be finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 15mm thick in CM (1:4) after dubbing out of average 15mm thick on irregular face of wall in cement plaster including water proofing compound all as specified and directed. Note:Water proofing compound shall be measured and paid seperately.
M&L for 10 mm thick rendering in CM (1:3) on fair face of brick/ concrete surfaces as in ceiling.
Supplying Integral water proofing compound.
S&F in Plaster Weld Wire Mesh with 25 x 25 mm mesh size made from 1.20 mm galvanised carbon wire before plastering the welded mesh mounted on wall by a solid dowel-nails or anchor bolts with small metal piece complete as directed by Engr-in-Charge.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (Using 40mm graded crushed stone aggregate) 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (Using 20 mm graded crushed stone aggregate) as in coping all as specified and directed.
M&L for PCC (1:2:4) type B-0 (Using 12.5 mm graded crushed stone aggregate) as in floor finishes 25 mm thick complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (Using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar.
M&L for stone dust layed in floors or paving etc spread, levelled and rammed including watering complete all as specified and directed by engr in charge.
M&L for machine pressed precast concrete interlocking paver block (Reflective type)in any shape and size confirming to IS-15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment.
M&L for TMT Bars 6 to 8 mm dia and over, cut to length and bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less 0.9 mm dia or securing with clips specified and directed.
M&L for Reinforced Cement Concrete M-25 (Using 20mm graded crushed stone aggregate) to Foundations, including rafts, footings, foundation beams, plinth beams ,bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as specified and directed.
S&F in repair drapery rod 20mm dia decorative type incl end knobs and brackets complete all as specified and directed.
M&L for granite 18-20 mm thick (of any type/ colour) (table rubbed and polished/ moulding) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing and white cement (1:2) using marble dust with admixture of pigment to match with shade or granite complete.
S&F in repair Bib tap chromium plated with flange any colour high pressure screwed for iron pipe and fixed. Make: Prayag or Equivalent as approved by the GE.
S&F in repairs 15 mm bore stop valves, fancy type, chromium plated srewed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions. Make: Prayag or Jaquar or Equivalent as approved by the GE.
S&F in repairs 15 mm bore stop valves, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions. Make: Prayag or Jaquar or Equivalent as approved by the GE.
S&F in repairs vitrous china squatting pan orissa 580x440 mm white with traps incl provn of concrete bedding and all necessary connection excluding flushing cistern and flush pipe.
S&F in repairs PVC low level flushing cistern of 10 Litres with all internal fittings incl flush pipe, PVC connection of 450 mm long and fixing to supply pipe, complete all as specified and directed.
S&F in repairs overhead square shower with rubit cleaning system 150mmx150mm, complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.50 mm thick sheet glass shelf 12 cm wide with CP bracket guard and railing 60 cm long fixed in repair.
S&F in repair tubular towel rail chromium plated 24'' long, complete all as specified and directed by engr in charge. Make: Jaquar or Equivalent as approved by the GE.
S&F corner glass shelf (with bracket), complete all as specified and directed. Make: Jaquar or Equivalent as approved by the GE.
S&F in repair for vitreous china wash basin, white,flat back, size 550x400 mm with brackets, incl PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc, complete all as specified and directed.
S&F in repair of 15mm bore dia of pipe pillar taps cast copper alloy, with capstan head chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed.
S & F in repairs CP grating with or without waste hole fixed in cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate, 100 mm bore.
S&F PVC connections 15mm size with PTMT nuts of length 450mm.complete as in repairs.
S&F in repair of 20 mm bore Gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed.
M&L for complete removal of existing treatment and applying two coats of exterior weather proof water base emulsion paint over and incl a coat white cement based putty all as specified and directed. Make: Shalimar (shaktiman) / Asian (ACE) / Burger or Equivalent as approved by the GE.
M&L for preparation of newly plastered surface of wall and applying two coats of exterior weather proof water base emulsion paint over and incl a coat white cement based putty all as specified and directed. Make: Shalimar (shaktiman) / Asian (ACE) / Burger or Equivalent as approved by the GE.
M&L for preparation of old decorated surfaces and applying two coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and iron surface of any description and applying two coats of synthetic enamel paint complete as specified and directed.
M&L for preparation of new untreated surface of steel and iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete as specified and directed.
M&L for Preparation of new plastered surface and applying two coats of oil emulsion distemper over one coat of white cement based putty all as specified and directed. Make: Shalimar/ Asian / Burger or Equivalent as approved by the GE.
M&L for complete removal existing treatment and applying two coats of oil emulsion distemper over one coat of white cement based putty all as specified and directed. Make: Shalimar/ Asian /Burger or Equivalent as approved by the GE.
M&L for Preparation new wooden surface of any description and applying two coats of synthetic enamel painting over a coat of pink primer all as specified and directed.
S&F Vitreous China bowl urinal flat back, size of 465x355x265 mm white (minimum), with grating and union for discharge pipe including waste pipe.
Preparation of old painted surfaces of wood/wood based materials exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as directed and specified.
Taking down existing old roof treatment of any description, any type including removal old Tar felt, screed etc, complete all as specified and directed.
M&L for provn of water proofing roof treatment to accessible RCC roof with APP modified membrane with non woven polyster reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal; insulation with white mineral/ gravel finish on upper side of membrane uniformely embedded during manufacturing process. All as per following specifications (100.01 to 100.07):
10 mm thick plaster in CM (1:4) mixed with and incl water proofing compound @3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding with water for seven days for any seepage / leakages etc. if any seepage is oberved the rectification will be carried out by pressure grouting under the pressure of 5 Kg/Sqcm using cement based cement grout. After the surface is repaired the slab will be tested for watertightness aginst before processing further treatments.
The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the grove shall be cut around to tuck in the treatment as pipes, chimneystacs etc. and other similar situations to ease up about corners.
Bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied an prepared surface till the surface is properly impregnated.
APP modified water proofing membrene as specified shall be laid on the primer surface by torch application method as per manufacturers instructions, The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer.
All joints & changes in direction should be curved with cement motor (1:3) mixed with SBR latex @ 200 ml per beg of cement and cured well before laying the membrane.
A fillet of PCC (1:2:4) type B-0 of 100 mm x 100 mm shall be provided at all junctions of vertical and horizontal surfaces and where ever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners / junctions should be rounded.
M&L for precast machine pressed cement concrete tiles with grey cement and no pigments of size 250x250x20 - 25mm thick conforming to IS 1237-1980 set in cement slurry laid jointed and pointed in neat cement slurry including bedding layer of 15mm thick screed in CM (1:4) as in roof complete all as specified & directed.
Taking down carefully the old U/S aluminum point wiring (light, fan, socket or power) complete fitting such as switches ,ceiling roses ,pendants, sockets ,regulators,light fittigs etc and making good disturbed surfaces of walls including necessary touch up with the same finishes to surrounding wall, floors etc complete all as specified and directed.
M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & including PVC conduit, medium grade of size not less than 20 mm dia ISI marked ivory white with all accessories such as tees, bends, elbows, reducers, bell mouth tube ends , couplers, lock nuts, saddles pipe hook, MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3 mm thick for mounting of switches/ sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 Sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green, complete all as specified for following :
One light /fan point controlled by one way switch
One 3 pin socket outlet 5 amps independent
One 3 pin socket outlet 5 amps point on same board
One 3 pin socket outlet 15 amps on independent board with cable 2.5 Sqmm and 1.5 Sqmm as earth wire. Note: For item No-102.00 (i) Cutting chases for concealed conduit and making good in cement mortar shall be deemed to be included in quoted unit rates. (ii) No cutting shall be done in roof for laying PVC conduit for ceiling point wiring. In this specific portion wire shall run through the existing conduit or surface new conduit shall be provided as reqd.
S&F switch piano, flush type 5 Amps single pole one way.
S&F socket outlet, 2 in 1 , 3 Pin 5 & 15 Amps.
S&F of switch piano, flush type 15 Amps single pole one way.
S&F Socket out let, 2 in 1, 3 Pin 5 Amps flush type.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals.
S&F stepped type electronic fan regulator flush type on the phenolic laminated sheet etc. suitable for ceiling fan 1200/1400mm sweep 240V, complete all as spcified and directed.
S&F lamp holder insulated with back plate suitable for Angle/Batten fitting.
S&F LED Tube light fitting 18/20 watt for surface mounted lumanaires batten with extrued aluminium housing and robust long life corrosion resistance impact proof surface mounting IP66 Lumanires PC housing in opeal finish coverwith high brightness including 18/20 W LED lamp and LM 79 & LM 80 certified (certificate to be enclosed). Make: Bajaj Product Code: 112410 or Equivalent make in Wipro / Crompton Greaves.
S&F 10 watt LED bulk head fitting energy saving generation 10W LED IP65, LM-79 & LM 80 certified luminaire with opal diffuser epoxy white powder coated heat resistant prismatic glass cover with specially designed gasket complete with spiral integrated including 10 watt LED lamp complete all as specified and directed. Make: Bajaj Product Code: 112334 or Equivalent make in Wipro/ Crompton Greaves.
S&F 2' X 2' ultra slim LED recess mounting luminaire 24 watt white powder coated CRCA housing luminaire with full window acrylic diffuser suitable for grid ceiling complete all as specified and directed. Make: Bajaj Product Code: 112412 or Equivalent make in Wipro / Crompton Greaves.
S&F 10 watt LED mirror light for surface mounted lumanaires complete all as specified and directed. Make: Bajaj, Product Code: 112408 or Equivalent make in Wipro / Crompton Greaves.
S & F LED lamp 9/10 W B-22 holder base with complete all as directed. Make: Wipro / Surya / Havells.
S&F Exhaust fan 225 mm sweep metal body with louvre 240V complete with all accessories with Heritage look including making hole in stone/brick wall grouting suitable size MI nuts/bolts & making good in all respects as directed by Engr-in-charge Make: Crompton Greaves Model No: Drift Air 9" or Equivalent make in Havells / Orient.
Taking down 1200/1400 mm sweep ceiling fan and refixing the same after cleaning/greaing/servicing complete all as specified and directed by Engr-in-charge
S&F SPN DB 8 way double door type(IP:43 protection) with metal door flush mounting to the wall and making good the disturbed surfaces including connecting cable to the SPN/MCB using the dolly and the wires in the DB which should be properly tied according to the colour code including taking down old unsv SPN DB complete all as specified and directed. Make: Legrand / Hager / Schneider.
S&F SPN 32 Amps, 240 volts complete all as specified and directed. Make: Legrand / Schneider or equivalent as approved by the GE.
S&F MCB SP 6 to 32 Amps 240V 10 KA C curve all as specified and directed. Make: Legrand / Schneider or equivalent as approved by the GE.
S&F factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space for MCCB as In comer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 100 Amp copper bus bar for each phase, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts including taking down old unsv VTPN DB complete all as specified and directed. Note: Rate of MCCB are excluding in the rate quoted for this item. Make: Legrand / Schneider or equivalent as approved by the GE.
M&L for MCCB 3 pole,415V, 100 amps with breaking capacity 36 KA all as specified and directed. Make: Legrand / Schneider or equivalent as approved by the GE.
M&L for MCCB 3 pole,415V, 160 amps with breaking capacity 36 KA all as specified. Make: Legrand / Schneider or equivalent as approved by the GE.
S&F LED building security/ street light fittings 35/36 Watt suitable for including GI brackets made out of 40 mm bore GI pipe light grade 1.5 mtr long bend to shape and fixed to the pole/wall with necessary MS clamp made out of 50X5mm flat end nut bolt and washer incl provn two single core PVC sheathed cable of suitable length 2.5 Sqmm copper conductor cable and connection complete all as specified and directed. Make: Bajaj, Product Code: 169913 or equivalent make in Wipro/ Crompton Greaves.
M&L for concealed sub main wiring with two single core PVC insulated, unsheathed copper conductor stranded 1100 volt grade cable of size 6 sqmm (FRLS) drawn in and incl PVC rigid conduit medium grade of size not less than 20 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc PVC insulated, unsheathed copper conductor stranded 1100 volt grade cable of size 4 Sqmm (FRLS) cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green Note: Two runs of 6 sqmm with one run of 4 sqmm copper conductor shall be measured as one unit length.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 (Using 20 mm graded crushed stone aggregate) Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as per SSR and connected to earth test point including testing as directed by Engr-in-Charge.
Supply and Laying in replacement cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested all as specified and directed at site
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for Sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directed. Note: Punned thickness shall be measured & paid.
Supply and laying burnt bricks sub class 'B' old size for cable protection complete all as specified and directed.
S&F GI Pipe light grade on wall/ Floor/ Trench for cable protection with fixing arrangement size 40 mm dia.
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
RAJPATI CONSTRUCTION
MODI CORPORATION
M/S RAKESH TRADERS
m/s Om Constructins
CREATIVE CONSTRUCTION
Vee kay construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .