Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Award of contract | |
| 2 | L2₹15.8 L+₹1.5 L (10.4%)Rejected-AOC M S KEWAL SONS SHIVA JI NAGAR GALI NO 1 MODEL TOWN PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹17.6 L+₹3.3 L (23.3%)Rejected-AOC | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹19.5 L+₹5.3 L (36.8%)Rejected-AOC | L4 | Rejected-AOC Other than lowest | |
| 5 | L5₹20.2 L+₹5.9 L (41.5%)Rejected-AOC | L5 | Rejected-AOC Other than lowest |
Tender Value
₹21.2 L
EMD Value
₹42,400
Closing Date
14 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL
HEADQUARTERS COMMANDER WORKS ENGINEERS YOL
SPL REP TO INTERNAL AND EXTERNAL ELECT SUPPLY SYSTEM AND ALLIED WORKS AT BAKLOH CANTT
2024_MES_649526_2
CWE/Y-05/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAKLOH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) DALHOUSIE
₹42,400
Yes
28 Sept 2024
21 May 2024
17 Jun 2024
21 May 2024
14 Jun 2024
31 May 2024
Amount
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. and getting out in hard and dense soil including taking out cable/cable cover and GI pipe, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
Supply and laying of 40mm graded crushed stone aggregate including levelling/spreading complete surrounding /under 2/4 pole structure and panel as directed by Engr-in-Charge. (Note:- Rates are deemed to be included for bricks reqd for retaining the aggregate)
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles, including necessary formwork where required complete all as specified and directed.
Chain link MS galvanisd fencing, 3mm dia, PVC Coating wire (mesh size 60x60mm), made upto matress lapped wire , including taking down old fencing all as specified.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, including taking down old sheet as specified, all as specified and directed.
Structural steel work as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.. conforming to grade Fe 410 -W (Gde-E- 250) quality-A for fencing angle/MS fabrication work, including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
75mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregates) as in sub base of flooring/ paving complete all as specified and directed. .
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper onver one coat of primer over and including a coat of 2 mm thick wall care putty complete, all as specified and as directed by Engr-in-Charge
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Point wiring with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size FRLSH (two run with colour code RYB) for one light point ,fan point, exhaust fan point,or bell point controlled by one switch including one run of 1.5 Sqmm (as continous earth wire Green)multistrand PVC concealed conduit of approved size and quality ISI marked,including all other required accessories as specified in preamable 1(a) to (q) of section 19 of SSR Part-II under heading 'point wiring' fixedon wall/ceiling including sunk cast iron terminal boxes grouting/flushing on wall for mounting fittings like switch,sockets etc covered with 3.00 mm thick plastic laminated sheet top cover of brick masonary/Stone masonary wall complete including cutting,chasing,pinning and making good the disturbed surface by using cement mortar 1:3 complete all as specified and directed by Engr-in-charge.,(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete).
All as per serial item No '18' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '18' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '18' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm FRLSH PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch piano flush type, single pole, one way, 16 Amps, all as specified.
Socket outlet, 3pin, , 6 amps flush type, all as specified.
Socket outlet two in one, 3 Pin 5 amps and 15 amps, flush type, all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for angular/ batten fittings complete all as specified & directed.
Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver., 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havell's Cat Part No. LUMILINEBS10WLED865SPCWH of "Havells" or equivalent in makes mentioned in Appendix
Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver., 20 watt LED,6500k, four feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havell's Cat Part No. LUMILINENEOBS20WLED865SPCWH of "Havells" or equivalent in makes mentioned in Appendix
Replacement of 35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket made up og 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specified Make: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
MCB SPN 32-40 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.
XLPE HT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 95 sqmm 3 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- (i)Excavation & Earth work, brick cable cover, GI pipe and sand cushioning shall be measured and paid separetly. (ii) High voltage test shall be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report shall be submitted in triplicate to Engr-n-charge. The cost of the same is deemed to be included in the quoted rate.
Replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified.
Renewal of vertical type air break switch, gang operated, triple pole, mechnically operated, vertically and horizontally mounted on 11 KV post type9 insulator with DO fuse unit, complete set, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 200 Amps current rating complete including dismantling existing air break switch all as specified and as directed.
Renewal of lightning arresters (Set of three) expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts including taking out old unservicable arrester and removing from site complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage 11 KV HT line for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of size 2m x 1m complete all as specified & directed..
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm to 120sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm to 120sqmm including cutting and removing existing unserviceable joint, including earth work complete, near 2 pole structure / HT Panel board / transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
On load chane over switch with SS enclosure, 63 Amp, 415 Volts AC 23 A, 4 Pole, fixed in replacemant with complete fixing arrangement on wall/pole surface and cable connection on both sides , complete all as specified. Make: L&T cat part No. CO10630OOOO or equivalent in Appx
Aluminum strip 25x3.15mm fixed with porcelain/PVC saddles and fixing screws etc including PVC gutties in each one metre length , for roof conductors and down conductors above ground, fixed in reapir , complete all as specified.
Air termination single pointed aluminum rod 12mm dia and 300mm long, including taking down old complete all as specified.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal .head screw including taking down old test point all as specified.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, and taking out old unservicable cable complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends,and taking out old unservicable cable complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, and taking out old unservicable cable complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 25Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, and taking out old unservicable cablecomplete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, and taking out old unservicable cablecomplete all as specified and directed.
Supply, installation , Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:2:4 Type B-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:-
Incoming:- (a) MCCB having current rating 100 Amps with rupturing cap 25 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -03 No) (b) On load change over switch open execution, 100 Amp, 415 Volts , 4 Pole (Qty-01 No.)
Outgoing:- (a) MCCB having current rating 63 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -02 No) (b) MCCB having current rating 40 Amps with rupturing cap 16 KA (Adjustable Thermal & Adjustable Magnetic) , AC 415 Volts,four pole, complete with spreader links. (Qty -01 No) (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Power factor , KW, KV etc. ( Qty-01 No) (d) Current transformer ratio of 200/5 Amps, Current rating primary upto 200 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice ( Qty- 01 set of three) (e) LED phase indicator lamp ( Qty- 01 set of three) (f) 150 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding.
Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble. (ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles. (iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing
Location : Near MES Main office Bakloh
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4) , type B-I using 20mm graded crushed stone aggregates with 40mm thick cover of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25X4 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 25 of tender doucments.
KEWAL SONS
dinesh enterprises
M/s Raj Construction
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .