Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.5 LAccepted-AOC C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | ₹33.5 L Quoted ₹34.1 L | 1 | Accepted-AOC LOWEST |
| 2 | 2₹44.2 LRejected-Finance | ₹44.2 L | 2 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | M/S Satyam Associates L1 | Kunal Construction Co. L2 |
|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed. | 14 | Cum | 95 ₹1,330 | 20 ₹280 |
| 2.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding and removing debries off the premisis complete all as specified and as directed. | 450 | Sqm | 5 ₹2,250 | 10 ₹4,500 |
| 3.00 | Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. | 700 | Sqm | 5 ₹3,500 | 20 ₹14,000 |
| 4.00 | Demolition of brick work or stone buillder built in cement mortar of any description complete all as specified and as directed. | 1 | Cum | 65 ₹65 | 250 ₹250 |
| 5.00 | M&L for brick work with sub class B works, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed. | 1 | Cum | 2,695 ₹2,695 | 4,500 ₹4,500 |
| 6.00 | M&L for 15 mm thick rendering of Ready mix mortar of approved make on brick/ concrete surfaces on external walls, fascia, parapet wall and RCC chajjas, finished the surface even and fair including water proofing compound by weight as per manufacturer's instructions, including necessary scaffolding up to (G+3 storey) complete all as specified and as directed. | 600 | Sqm | 175 ₹1.1 L | 380 ₹2.3 L |
| 7.00 | M&L for 10 mm thick rendering of Ready mix mortar of approved make on brick/ concrete surfaces on internal walls, surfaces even and fair as per manufacturer's instructions, including necessary scaffolding complete all as specified and as directed. | 120 | Sqm | 175 ₹21,000 | 350 ₹42,000 |
| 8.00 | M&L for 10 mm thick rendering of Ready mix mortar of approved make on brick/ concrete surfaces on ceiling surfaces even and fair including necessary scaffolding complete all as specified and as directed. | 40 | Sqm | 175 ₹7,000 | 350 ₹14,000 |
| 9.00 | M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in sub base of floor etc complete all as specified and directed. | 60 | Sqm | 175 ₹10,500 | 120 ₹7,200 |
| 10.00 | M&L for vitrified tiles as in flooring of size (2400 x 800)mm x 15mm thick, set and jointed in neat cement slurry with and pointed in white or coloured cement to match with and including over 15mm thick screed bed with CM (1: 6) complete all as specified and as directed. | 450 | Sqm | 1,000 ₹4.5 L | 2,500 ₹11.3 L |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Feb 2026, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT 10
GE (AF) PALAM DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF B/R AND E/M WORKS TO OTM AND MD ACCN AT RV AREA AT AF STN PALAM UNDER GE (AF) PALAM DELHI CANTT-10
2026_MES_748270_1
8025/A/T-77/E8
Open Tender
Civil Works
270 days
GE (AF) PALAM DELHI CANTT 10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM DELHI CANTT 10
₹80,000
Yes
11 Apr 2026
13 Jan 2026
17 Feb 2026
13 Jan 2026
10 Feb 2026
27 Jan 2026
Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and removing debries off the premisis complete all as specified and as directed.
Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Demolition of brick work or stone buillder built in cement mortar of any description complete all as specified and as directed.
M&L for brick work with sub class B works, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for 15 mm thick rendering of Ready mix mortar of approved make on brick/ concrete surfaces on external walls, fascia, parapet wall and RCC chajjas, finished the surface even and fair including water proofing compound by weight as per manufacturer's instructions, including necessary scaffolding up to (G+3 storey) complete all as specified and as directed.
M&L for 10 mm thick rendering of Ready mix mortar of approved make on brick/ concrete surfaces on internal walls, surfaces even and fair as per manufacturer's instructions, including necessary scaffolding complete all as specified and as directed.
M&L for 10 mm thick rendering of Ready mix mortar of approved make on brick/ concrete surfaces on ceiling surfaces even and fair including necessary scaffolding complete all as specified and as directed.
M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in sub base of floor etc complete all as specified and directed.
M&L for vitrified tiles as in flooring of size (2400 x 800)mm x 15mm thick, set and jointed in neat cement slurry with and pointed in white or coloured cement to match with and including over 15mm thick screed bed with CM (1: 6) complete all as specified and as directed.
Description all as per ser item no 10 above but on vertical surfaces of wall, skirting with and including over 10mm thick rendering of CM (1:4) etc complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but n exc 0.18 sqm as in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete with and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for vitrified tiles light shade 8 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc, with and including over 15mm thick screed bed in CM (1:6) complere all as specified and as directed.
Description all as per ser item no 13.00 above but in vertical surfaces of wall, skirting with and including over 10mm thick rendering of CM (1:4) complete all as specified and as directed.
M&L for 75mm thick cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen 85/25 and sand in the proportion of (1:3 ) by weight complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
S&F tubes, 'medium grade' 15mm bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Description all as per ser item No 18.00 above but 20mm bore complete all as specified and as directed.
Demolition and breaking up drain pipe 100mm dia ( Salt glazed ware, AC or PVC) of any type complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified and as directed.
S&F in repairs PVC (SWR) bends any radius, 110 mm bore complete all as specified and as directed.
Dismantaling water tank and removal from site of capacity exc 500 ltr and n exc 1000 ltr complete all as specified and as directed.
Dismantalling water tank and removal from site of capacity exc 250 ltr and n exc 500 ltr complete all as specified and as directed.
M&L for 500 litres capacity rotational moulded polyethene water storage tank, white colour, three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
M&L for 1000 litres capacity rotational moulded polyethene water storage tank, white colour, three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
S&F in repair ball brass valves, 20 mm bore, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F in repair gun metal globe or gate valves, 15 mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Dismantling AC/CGI corrugated steel sheeting any gauge thickness including Nainital or similar pattern roof coverings, complete all as specified and as directed.
S&F 35/40 mm thick puf panel typically features a core of rigid polyurethane form with an average density of approximate 40 kg/m and a thermal conductivity of about 0.023 to 0.03 W/mk. The panel is enclosed by outer and inner skins, often made of 0.50mm thick pre-painted galvanised iron ( PPGI) sheet of any colour and fixed in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for preparation of plastered or unplastered old decorated surface of walls by brooming down or with steel wire brushing, scraping down, smoke soot's, moulds, moss efflorescent, salts & trading oil, greasy spots and filling cracks/holes with wall care putty and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparation of plastered or unplastered old decorated surface of walls by brooming down or with steel wire brushing, scraping down, smoke soot's, moulds, moss efflorescent, salts & trading oil, greasy spots and filling cracks/holes with wall care putty and applying two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of plastered or unplastered old decorated surfces by brooming down or steel wire brushing scraping down smoke soot, mould, moss efforescent, salt & trading oil and grease spots and filling cracks/holes with wall care putty and applying one coat of oil bound distemper on ceiling complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood & wood based surfaces of any description not otherwise described over 10 cm width & girth and aplying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and iron surfaces of any description not otherwise described over 10cm width & girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparing new plastered surfaces and applying two coats of distemper oil emulsion on wall surfaces including primer over 2mm thick cement based wall care putty complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper including primer over 2mm thick cement based wall care putty complete all as specified and as directed.
Disconnecting existing tanks of capacity exc 250 and n exc 500 ltr of PVC, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed. Note:- Cleaning, repairing, etc. shall be measured and paid separately.
Disconnecting existing tanks of capacity exc 500 and n exc 1000 ltr of PVC, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed. Note:- Cleaning, repairing, etc. shall be measured and paid separately.
M&L for applying two or more coats of Damp Proof Course (Primeless high built water based elastomeric exterior wall waterproof acrylic coating for exterior surfaces) designed with weather resistance acrylate polymers, UV resistance and good hiding and spreading, developing a strong intercoat adhesion with the substrate therefore no seperate primer is required, features such as waterproofing, UV protection, Anti algae resistance, crack bridging of elastic films covering hair line cracks, long term protection, colour varients. Preparation of surfaces by cleaning the surfaces till it is free from dust, grease and flaking paint, any unstable paint to be removed, using high pressure wash or scraper, whichever is appropriate. Algae and fungus on the wall to be removed by using high pressure wash or coir brush and shall be treated with fungicidal solution, all surface cracks upto 5 mm width shall be treated with fungicidal solution and filled up with crack-X-paste. Crack more than 5 mm and all seperation gaps should be filled up with URP modified mortar or as specified complete all as specified and as directed by Engr-in-Charge. Note :- 1. Application for vertical surface fresh plaster or repainting on old prepared surfaces. 2. Use it directly from the container. stir contents well before use. 3. Brush/roller apply a self priming coat of it on the vertical wall surface in SSD condition, diluting 1 litre with 100 ml clean potable water. Allow it to dry for 4-6 hours. 4. Apply a coat of it without dilution as waterproof top coat, either by roller or brush with force coverage at the rate of 3.7-4.1 Sqm/litre to achieve DFT of 100-110 microns. Allow it to dry for 4-6 hrs lighter shades of white base on the top of dark colours need additional coat for finishing. 5. An additional coat should be applied in case of horizontal surfaces like the top of windows, ledges, parapet wall etc allow the coating to full air cure for 7 days.
M&L for complete removal and preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint over a coat of exterior water based primer of same make with and including over 2mm thick cement based wall care putty complete all as specified and as prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior antifungal acrylic emulsion paint (wall mista of Berger paint or equvalent in Asin paint , Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make, over and including 2mm thick cement base wall care putty complete all as specified and as prescribed by manufacture of paint and as directed at site by Engineer -in Charge. Notes for Ser item No. 41.00 & 42.00:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it shall be made even all as per manufacture instructions before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back gurantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii) All the materials to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v) The colour/ shade will be all as approved by GE. (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor. (vii) Exterior painting shall be having three years of performance warranty by the contractor.
M&L for complete removal of old surface of walls by electrically operated grinder including necessary scaffolding up to (G+3 storey) etc and applying two coats of exterior emulsion paint over a coat of primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engineer - in- charge.
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type complete all as specified and as directed.
Taking down unservesiable sub main wiring with conduits/battens etc complete all as specified and as directed.
Description all as per srl item No 46.00 here-in-before but for 3 pin 5 Amps socket out let on independent board and different wall controlled by one switch complete all as specified and as directed.
Description all as per srl item No. 46.00 here-in-before but for one 3 pin 5 Amps socket out let point on the same board controlled by one switch complete all as specified and as directed.
Description all as per srl item No 46.00 here-in-before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable size 1.5 Sq mm PVC insulated stranded sheathed copper conductor complete all as specified and as directed.
Description all as per srl item No 46.00 here-in-before but for two way switch point controlled by one push button on the same board with other switches or independent with cable size 1.5 Sq mm PVC insulated stranded sheathed copper conductor complete all as specified and as directed.
Description all as per srl item No 46.00 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated FRLSH including earth wire 2.5 Sq mm copper FRLSH conductor cable connected to earth dolly complete all as specified and as directed.
S&F modular switch 1 way 6 Amps one module complete all as specified and as directed.
Supply and fixing of modular socket 6 Amps 2/3 Pin combined 02 module complete all as specified and directed.
S&F modular switch one way 16 Amps, one module complete all as specified and as directed.
S&F socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed.
S&F of ceiling rose, surface type, 65mm x 50mm, 3 terminal complete all as specified and as directed by Engr-in-Charge.
S&F of electric bell, multi music type, 230 volt AC, single pole, complete, all as specified and as directed by Engr-in-Charge.
S&F of modular bell push 6 Amps one module complete all as specified and as directed by Engr-in-Charge.
S&F of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed by Engr-in-Charge.
Supply and fixing stepped type fan regulator 120 watt, 230 volts, 50 Hz, AC supply complete all as specified and as directed.
Supply and fixing modular stepped type fan regulator 100 watt, one module 230 volts, 50 Hz, AC supply complete all as specified and as directed.
Supply and fixing for modular stepped type fan regulator 100 watt, two module 230 volts, 50 Hz, AC supply complete all as specified and as directed.
S&F in replacement modular white cover plate with frame 1 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame 2 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame 3 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame 4 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame 6 module complete all as specified and as directed.
S&F in replacement modular white cover plate with frame 8 module complete all as specified and as directed.
S&F in replacement modular metal flush box suitable for 1/2/3 module complete all as specified and as directed.
S&F in replacement of modular metal flush box suitable for 4 module complete all as specified and as directed.
S&F in replacement of modular metal flush box suitable for 6 & 8 module complete all as specified and as directed.
S&F indoor decorative LED battens- integrated type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as specified and as directed.
S&F indoor decorative LED battens- integrated type 10 watt 2 feet white fixture with extruded aluminium body, suitable for LED tube 10 watt , bipin holder, connector block, LED rod 10 watt etc complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as specified and as directed.
S&F bulk head LED fitting 10 watt with PDC aluminium housing and milky diffuser complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as specified and as directed. Make: Halonix Cat Pt No HLBH-02-10-CW or equivalent in Wipro/Philips/Havels/ Syska.
S&F decorative LED wall bracket light fitting made up of Polycarbonate suitable for B-22 base including one No 12 watt LED bulb, complete all as specified and directed.
S&F in replacement of LED lamp E 27 base 4.9 W 3000 K complete all as specified and as directed.
S&F in replacement of LED lamp E 22 base 6 W 3000 K complete all as specified and as directed.
Supply and fixing in replacement of sheet metal enclosure for distribution board SPN (when MCBs to be used ) 4 way double door, 200 Amps, rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed.
Supply and fixing in replacement of sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 ways double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed.
Supply and fixing in replacement of sheet metal enclosure for distribution board SPN (when MCBs to be used ) 12 way, double door , 415 Volts 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed.
Supply and fixing in replacement of vertical type load line distribution board, double door, 8 way, IP 43 IK09 AC, 3 phase, 415 volts, TPN bus bar 250 Amps rating and earth bar & din rail complete all as specified and as directed.
Supply and fixing in replacement of for vertical type load line distribution board, double door, 4 way, IP 43 IK09 AC, 3 phase, 415 volts, TPN bus bar 250 Amps rating and earth bar & din rail complete all as specified and as directed.
Supply and fixing in replaccement of metel clad socket outlet 3 pin, two phase one neutral, 20 Amp suitable for metal clad AC box complete all as specified and as directed.
Supply and fixing in repalcement of metel clad plug top 3 pin, two phase one neutal 20 Amp suitable for metal clad AC box complete all as specified and as directed.
Supply and fixing in replacement of MCCB, 3 pole 100 A, 16kA, 415 Volts complete all as specified and as directed.
S&F MCCB, 4 pole 100 Amp, 16kA, 415 Volts complete with connections complete all as specified and as directed.
Supply and fixing in replacement of MCCB, 3 pole 160 A, 25kA, 415 Volts complete all as specified and as directed.
S&F MCCB, 4 pole 160 Amp, 25kA, 415 Volts complete with connections complete all as specified and as directed.
S&F in replacement PVC 3.5 core copper conductor flexible cable 2.5 sqmm for connection etc complete all as specified and as directed.
S&F in replacement PVC 3 core copper conductor flexible cable 2.5 sqmm for connection etc complete all as specified and as directed.
S&F in replacement PVC 3 core copper conductor flexible cable 1.5 sqmm for connection etc complete all as specified and as directed.
S&F in replacement LED bldg light/ security light 35 watt IP66 with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed.
S&F in replacement LED gate light 25 watt IP66 with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed.
S&F in replacement LED security light/ SL 90 watt IP66 with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and as directed.
Supply and fixing in replacement Decorative wall light/ wall lamp comet indoor wall lamp grey/white colour sconce for living room & bedroom B22 base complete all as specified and as directed.
Supply and fixing in replacement combined box 16 Amp 6 pin 3 module complete all as specified and as directed.
Supply and fixing in replacement combined box 16 Amp 6 pin flush type complete all as specified and as directed.
Supply and fixing in replacement combined box 6 Amp 3 pin flush type complete all as specified and as directed.
Supply and fixing in replacement bollard light upto 12 watt including PCC work with nuts & bolts complete all as specified and as directed.
S&F BLDC 1200mm sweep ceiling fan with remote 5 star rated 380 RPM, low noise air flow 225 CMM low wattage 30 watt complete all as specified and as directed.
Supply and fixing in replacement of fan capacitors of 2.5 Mfd made up of plastic with copper terminal wire including MS / PVC clamp of required size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of fan capacitors of 3.15 Mfd made up of plastic with copper terminal wire including MS / PVC clamp of required size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of ventilating fan 200 / 230mm dia, 230 volt 50 Hz 32 watt complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of ventilating fan 300mm dia, 230 volt 50 Hz 40 watt complete all as specified and directed by Engineer-in-Charge.
Supply only exhaust fan motor 0.16 HP, suitable for 230/ 320mm sweep size of exhaust fans, AC single phase, 50 Hz, 1500 RPM, frame B42, double bearing, trusted copper winding, high speed complete all as specified and directed by Engineer-in-Charge.
Supply only exhaust fan motor 0.25 HP, suitable for 450mm sweep size of exhaust fans, AC single phase, 50 Hz, 1500 RPM, frame B48, double bearing, trusted copper winding, high speed complete all as specified and directed by Engineer-in-Charge.
Material and labour for submain wiring with 2 run of 4.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one run of 4.0 sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed.
Material and labour for submain wiring with 2 run of 6.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one run of 6.0 sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed.
Material and labour for submain wiring with 2 run of 10.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one run of 10.0 sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed.
S&F in repair 1.5 sqmm (nominal area) FRLS PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor complete all as specified and as directed.
S&F in repair 2.5 sqmm (nominal area) FRLS PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor complete all as specified and as directed.
S&F in repair 4.0 sqmm (nominal area) FRLS PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor complete all as specified and as directed.
S&F in repair 6.0 sqmm (nominal area) FRLS PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor complete all as specified and as directed.
S&F in repair 10.0 sqmm (nominal area) FRLS PVC insulated and unsheathed single core cable 1100 volts grade with stranded copper conductor complete all as specified and as directed.
M&L for earthing complete for building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_837966.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
tender.pdf
Tender Documents • 1.10 MB
BOQ_837966.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid