Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC 368 MAHESHPUR SECTOR 21 PANCHKULA HR 134112 | PANCHKULA | PANCHKULA | HARYANA | 134112 | ₹4.0 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹4.7 Cr+₹74.8 L (18.8%)Rejected-Finance | ₹4.7 Cr+₹74.8 L (18.8%) | L2 | Rejected-Finance SINCE NOT L1 |
| 3 | L3₹6.2 Cr+₹2.2 Cr (55.6%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹6.2 Cr+₹2.2 Cr (55.6%) | L3 | Rejected-Finance SINCE NOT L1 |
| 4 | L4₹7.5 Cr+₹3.5 Cr (87.7%)Rejected-Finance | ₹7.5 Cr+₹3.5 Cr (87.7%) | L4 | Rejected-Finance SINCE NOT L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Firm do not full fill the requisite criteria as per NIT |
Tender Value
₹3.9 Cr
EMD Value
₹4.7 L
Closing Date
26 May 2021, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD
PROVISION OF FIRE FIGHTING AND EXTERNAL SERVICES INCLUDING ALLIED WORK FOR AD WING AT AF STATION BAMRAULI
2021_MES_409768_2
958986/E-8
Open Tender
Civil Works
Lump-sum
273 days
GE AF BAMRAULI
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) BAMRAULI
₹4.7 L
Yes
5 Jul 2021
8 Apr 2021
31 May 2021
8 Apr 2021
26 May 2021
12 May 2021
Amount
SCHEDULE A PART I (BUILDING WORKS)
Construction of Building and allied Works comprising the following buildings all as specified and as shown on drawings.
Lump sum price worked out by the contractor for Construction of Pump House Building for Water Mist and Water Hydrant as listed in Sch ‘A’ Part I .
Schedule A Part-II ( Internal Electric Supply)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II .
Schedule A Part-III ( External Electric Supply)
Lump sum price worked out by the contractor for External Electric Supply as listed in Sch ‘A’ Part III .
Schedule A Part-IV ( Fire Hydrant system )
Lump sum price worked out by the contractor for Fire Hydrant system as listed in Sch ‘A’ Part IV.
Schedule A Part-V ( WATER MIST SYSTEM )
Lump sum price worked out by the contractor for WATER MIST SYSTEM as listed in Sch ‘A’ Part V
Schedule A Part-VI ( Road, Path & Culvert )
Lump sum price worked out by the contractor for Road path and Culvert as listed in Sch ‘A’ Part VI
Schedule A Part-VII ( ADDN/ ALTN OF EXISTING STATIC WATER TANK )
Lump sum price worked out by the contractor for ADDN/ ALTN OF EXISTING STATIC WATER TANK as listed in Sch ‘A’ Part VII
Schedule A Part-VIII ( EARTH WORK)
Lump sum price worked out by the contractor for EARTH WORK as listed in Sch ‘A’ Part IX
Schedule A Part -IX(Misc item)
M&L for dewatering and cleaning of sludge of static water tank of dia 7.50 mtr and 3.00 mtr depth including removal of sludge to a distance exc 1.50 KM and not exc 5.0 KM complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring using two single core PVC insulated , unseathed , stranded copper conductor cable of size 2x4 Sqmm of voltage rating upto and including 1100V drawn in and including concealed PVC conduit of dia not less than 20 mm with standard accessories along with one run of PVC ( green colour) insulated , unseathed , standard copper conductor of size 1x4 sqmm as earth continuity conductor all as specified and directed . NOTE : 2 run of single core PVC cable with one run of earth conductor and conduit shall be measured and one unit).
S&F factory made epoxy coated Distribution Board SPN 8 Ways 240 volt grade ( SPN MCB DB) with double door ( IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar , neutral bar , standard DIN rail , Earth bar and cable ties for cable management , top and bottom removable gland plates with knockouts complete all as specified and directed.
S & F MCB SPN 40 Amps , 240 volt C curve 10 KA complete all as specified and directed by Engineer-in-charge.
S & F MCB SP 6-32 Amps 240 Volts C Curve 10 KA complete all as specified and directed by Engineer-in-charge.
S & F porcelain PVC seathed connector two way complete all as specified and directed by Engineer-in-charge.
S & F ceiling fan with down rod , 1200 mm sweep with 3 blade and connecting up including provision of three core PVC insulated multi stranded flexible copper conductor cable of size 1.5 sqmm copper wire from connector to fan of length not less than 1.0 mtr complete all as specified and directed by Engineer-in-charge. Make: Crompton ( Model : Aura plus -5 star) , Orient ( Model: Energy Star) , Standard ( Model: Super Speed 50).
S &F Exhaust fan of 300 mm sweep single phase 230 V AC ,1400 RPM with louvered shutter including mounting frame and connecting the fan to ceiling rose including provision of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified and directed by Engineer-in-charge. Make : Usha ( Model : Aeroclean) , Havells ( Model : Ventilair DS) , Standard ( Model : Refresh Air SPS) .
S & F wall mounted endure linear LED light fitting with LED light fitting tube type complete with LED lamp of 1x20/24 watt ( 4 ft) , extruded aluminium heat sink provided for efficient heat dissipation & integrated electreonic driver complete with all acessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with 0.5 sqmm complete all as specified and directed by Engineer-in-charge. Make : Philips ( Cat Part No : BN 021C LED 20S PSU CW GR S2) , Havells (Cat No : ENDURALINEARNEOBS20WLED830SPCWH) , Crompton ( Cat PArt No : LCCLB24-CDL) , Bajaj ( Cat PArt No: BCLAB 20W).
S&F security light fittings new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP-66 roadway luminaire 45 Watt LED 6000K asymmetric optics with driver etc complete internally pre wired and connecting to ceiling rose and fitting with three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm copper wire including fittings arrangement comprising of 40 mm GI pipe light grade 1.5 mtr long bend at 120 degree fixed to wall with 2 Nos clamps made of FI 50x6 mm and necessary nut , bolts and washer complete . Make : Havells Cat Part No. ENDURAPEARLOSL45WLED757SASYPOPC / Bajaj Cat Part No. BRTFG45 W LED I / Crompton ( Cat PArt No: LSTS-45-CDL-M).
M & L for sub class 'B' bricks well burnt old size axis of the bricks perpendicular to the axis of the cable , laid flat over sand coushioning for protection of cable complete all as specified and directed.
M & L for making 'Tercel' High conductive, Non corrosive, Maintenance Free and Repairable 'Chemrod' Electro-Chemical - Gel earth pit using earth enhancing compound ISOGEL as per requirment, CPRI tested of 3 inch dia, 8 ft long and 0.12 inch thick made of 'K' type electrolytic copper with top removal gel filling cap, seepage holes, Stainless steel fasteners, HDP Lockable earth pit cover cum inspection chamber and all required accessories including design modifications, to achieve the required earth termination rod resistance value below 1 ohms or as per the OEM/ International standard recommendation. Make:- Tercel/ Indelec/ Ereko
Supply, installation, Commissioning and testing pedestal mounting type, HV Junction box of size 1.8 m(H) x 1.5 m(W) x 1.0 m(D), suitable for 3 phase 11 KV , AC 50 Hz supply, made out of 3.15 mm thick CRCA MS sheet with 50mm x 50mm x 6mm angle iron frame, supports and legs, dust and vermin proof, suitable for Outdoor applications( IP-65 Protection) having canopy on top, double door in front side (Inner door should be bolted type and outer door should be hinged type with locking arrangement), complete with powder coated epoxy paint (RAL 7032 - SIEMENS GRAY) all over the steel surfaces(both internally & externally) and complete with aluminium bus bar of suitable shape and size and length not less than 1.0mtr for 3 phase rating of 600 amps duly mounted on suitable insulators and suitable bracket for clamping the cables with clamps complete including brick pedestal 450mm height above ground level for fixing M.S angle legs.
S&F Load Break Switch (LBS), HT 11 KV, with integral earth switch & fuse trip confirming to IEC 60265 /IS 9220, Indoor type 2.0mm thick CRCA M.S sheet enclosure with following specification :- a) Panel type designation- CSH 12 rated system voltage 12 KV b) Rated current rating 400 amps c) Nominal system voltage - 11 KV, 50 Hz d) One minute power frequency voltage withstand level -28 KV RMS. e) 1.2/50 micro second impulse voltage withstand level - 75 KV peak f) Type of Insulation - Air insulation, 3 poles g) Rated short time withstand current 25 KA/3 Sec h) Rated short circuit breaking capacity - Not assigned. HT HRC Fuses of 25 KA used to break SC current and trigger the tripping mechanism of load break switch. i) Rated Short Circuit making capacity - 62.5 KA. j) Cable termination - Incoming / Outgoing cables entry/exit from bottom. k) Type of operating mechanism - Quick make, Quick break, manual spring assisted toggle. l) Type of Installation - Indoor Type, Floor Mounted m) Degree of protection - IP 54 n) Paint type and shade - Epoxy based powder painting to shade RAL 7032 Make : ABB / SCHNEIDER / SIEMENS Note : (i) Any item missed out above but is technically required for safe and proper operation of equipment, shall deemed to be included in the quoted rate. (ii) The contractor shall have to arrange for factory visit to witness the Routine and Type Test (Non Destructive) as per relevant IS / IEC codes, in the presence of representative of Accepting Officer.
Outgoing :- (a) MCCB 4 pole 630 Amps with breaking capacity 25 KA adjustable thermal and adjustable magnetic type -01 No.(For Water Mist Pump House Panel) (b) MCCB 4 pole 200 Amps with breaking capacity 25 KA adjustable thermal type -01 No (For AC Plant) (c) MCCB 4 pole 125 Amps with breaking capacity 16 KA adjustable thermal type -01 No (For Fire Hydrant Pump House) (d) MCCB 4 pole 100Amps with breaking capacity 16 KA adjustable thermal type -01 No (Spare) Note :- 1. Cost of Panel Board shall be inclusive of end termination of all LT cables for all incoming / outgoing connections including provision of Cable glands and aluminium cable lugs, Nuts, Bolts & Washers etc.. 2. Cost of Panel Board shall be inclusive of brick platform of suitable length & breadth but height not less than 600mm above FL. 3. Aluminium feeder marker plate of suitable size shall have to be rivetted on the front door as per the marking of ACB / Each MCCB as mentioned above, 4. Spreader Link of suitable rating shall have to be provided to all outgoing MCCBs for internal connections from bus bars and also for terminating the outgoing cables. 5. All internal connections from bus bars to outgoing MCCBs shall have to be carried out by insulated aluminium bars of suitable cross section to carry rated current of the outgoing MCCBs. 6. All control wiring shall have to be carried out with 1100 Volts rated GRAY coloured PVC insulated 1.5 Sqmm copper multiflexible wire of size 1.5 Sqmm duly ferrule marked and lugged.
S&F insulating mats, suitable for laying infront of HT(11KV) switchgears, chemical resistant, anti skid type, made of mixture of rubber & synthetic polymers, ISI marked ( IS : 15652 - 2006) to be embossed on every metre. Suitable for 11 KV ( Class- B, Thickness-2.5mm), Blue colour, Width 1.0mtr and operating temparature -10ºC to +60ºC including all adhesive and pasting materials for fixing on floors / Cable duct cover etc. complete all as specified and as directed. Make : Metro Rubber Corporation / DURATUF / CATU
Supply , Installation , Testing in commisioning of additional exhaust piping ( dia of M.S. Pipe tobe matched with the exhaust pipe of the diesel engine driven pump) with heat resistance asbestoes rope insulation wrapped with POP impregnated bandaging all along the pipe including a cowl at the top with necessary MS clamps on wall / cielling complete all as specified , directed
07 Nos Triplex plunger high pressure pump made of SS body with suitable capacity , 3 phase , 50 Hz , AC motor :- Supply, Installation ,testing and commissioning of complete high pressure water mist system of modular design comprising of the following item including: (i) High pressure pump unit of capacity flow rate of 120 l/min at 120 Bar (ii) SS Strainer ,Safety Valve ,SS filter ,with 100 micron Capacity -1 Lot (iii) Hose NBR (Nitrile butadiene rubber) ,NRV (Non return valve) ,Pressure Gauge : O-250 Bar ,SS,pressure, 0-250Bar ,SS/Brass over flow Valve ,SS Test Valve etc-01 Lot (iv) Interconneting SS pipe and and valves of required dia etc as required for proper functioning of the pump unit and all the equipments are mounted on a single skid complete all as specified & directed by Engr-in-Charge.
Control cabinet for High Pressure unit (6+1)x120 open system numbers: Supply Installation Testing & Commissioning of PLC based floor mounted control cum 3Ph, 415V, power panel made out of 2mm thick CRCA sheet, 1.5mm for the door duly powder coated with RAL 7035 (Light grey ) and having IP 54 protection along with gear accessoris including connection and interconnection with copper busbar wire suitable rating etc. as reqd and a display unit for monitoring signals and indication of faults .control cabinets should have several self -diagnostic functions and failures are detected automatically. Pumps can also be manually operated and tested with push buttons on the door of control cabinet Complete cabling of lntenal system on connector blocks provided for external cabing/signals ,controlling is realised through PLC ,buffer action of the controling through emergency power supply for 30 minutes (2x12 V,7.2 Ah) complete in all aspect.Cable entry from the botten .Panel should have a Potential -free change -over contact 230 V AC /5 A for general faults and Potential -free change-over contact-230V AC /5 A for opreation signal high pressure pump Modules for the operation of Hose Reel Cabinet and a7'' TFT Display complete all as specified & directed by Engr-in-Charge. Indicators and operational controls Operation HP -Pump 1-7 Tank filling solenoid valve ,level measurement Tank level (low level) Pressure sensor pressure -high pressure manifold Power supply 400 V AC /24 V DC Reset Alarm horn off Key switch HP-pump 1-7 Dispaly of current (Amp) Display of Voltage Lamp test via display Horn : 95 dB +/-5 % 0,1 m for general faults Incomer:- (i) MCCB 400 Amp TPN AC -1 Nos Outgoing - (i) 63 Amp MCB TPN (for 7 Pumps )-7 Nos (ii) 32 Amp MCB TPN - 1 Nos for for terrace pump (iii) Stra -Delta Starter of suitable rating (with over laod protection) for High Pressure Pumps -7 Nos (iv) 6 Amps fuse of suitable routing ( For Jockey pump).
Break Tank :-Supply, Installation,Testing and Commissioning of 3000 liter break tank made of Polyethylene (Black) mounted on zinc plated steel frame of required strength with the following accessories:- Main Filter -100 micron solenoid valve 230 V AC with manaul override Overflow via rectangular opening in sidewall of tank including closure flap Pressure sensor for tank level measurement Level gauge for optical filling level indication Suction line with shut-Off and drainage valve .
Supply ,Installation ,Testing and Commissioning of solenoid operated section valve ,for controlling of individual zone Materials (contact to water ) Stainelss Steel Valve operation ; Normally Closed Including : Shut -off ball valve for main pipe and Shut-off ball valve for test connection.
solenoid operated section valve ,size 1/2", 140 bar 24V DC ,0.75 Amps
solenoid operated section valve ,size 1", 140 bar 24V DC ,0.75 Amps
solenoid operated section valve ,size 1½", 150 bar 24V DC ,1.92 Amps
Nozzle:- Supply ,Installation ,Testing & Commissioning of high pressure water mist Stainless open type nozzles having K-factor as following ,operating pressure of 120 bar and Extinguishing droplet spectrum 50 to 100µm .Nozzles should have imbbedded stainless steel micre nozzles with centralised SS316 filters and brass swirling device and including O-ring complete in all aspect.
Nozzle body having multiple discharge ports ,k-factor -0.696
Nozzle body having multiple discharge ports ,k-factor -1.2
Nozzle body having multiple discharge ports ,k-factor -0.464
Industrial Socket :- Supply ,Installation ,Testing & Commissioning of Stainless material Industrial sockets of L 12 size including cuting ring and nut for nozzle mounting complete in al aspect.
Supply ,Installation ,Testing and commisisioning of wall cabinet with Watermist gun comprising of 12 mm 50 meters long high pressure hose and water mist fire fighting gun . The first setting creates a very effective fine droplet water mist ,so even fluid or dust fires can be put out with out splashing .The fine mist can be used in conjunction with a centrally located jet that creates a coarse mist .The water mist gun also produces lateral jets to protect the fire fighter from radiant heat . Material of box Carbon steel & Corrsion resistant painting . Fire Fighting Gun:- Flow 25 ltr/min @ 100 bar with 12 side nozzles 1 center nozzle. Hose : 12 mm ,50 meters with stainless steel fitting Colour : Red (RAL 9000)
Supply ,Installation ,Testing and commisisioning of Mobile Unit (Diesel Driven) comprising of (i) 9 HP diesel engine 60 meter length high pressure hose dia 10 mm , Flame Resistant Extingusihing gun watermist with 5 different spray patterns Nozzle head with very fine fog nozzles and central fog nozzle Optional Operation to operate with Foam .
60 mm dia
50 mm dia
40 mm dia
32 mm dia
28 mm dia
25 mm dia
22 mm dia
18 mm dia
16 mm dia
12 mm dia
S&F rotational moulded double layered polyethylene water storage tank of 5000 litre (Cylinder vertical with closed top) hosted and fixed in position all as specfied in SSR Par-I (For priming of pump)
S&F rotational moulded doble layered polyethylene water storeage tank of 3000 liter (Cylinder vertical with closed top) hoisted and fixed and fixed in position all as specified in SSR Part-I (For priming of pump)
Supply, Fix testing and commisioning RO unit for 1000 litre per hour capacity for purification of water to suit water quality complete all as specified and directed.
Supply ,fix . Installation Commisioning Booster pump for 415 V 3 Phase , 50 Hz confirming to IS -12469 with CI casing Bronze Impeller and stainless steel shaft mounted on heavy duty bearings suitable for 44V ,3 Phase , 50 Hz , 7 mtr Head ,200 Litre /min discharge to be fixed at pump house for supplying water to over head rank ( 1 working + 1 Standby) with low water level sensor ( fitted in over head tank ) duly integrated with sensor for operation Complete all as specified and directed.
Supply, installation, testing and commissioning of UL (Underwriters Laboratories ) listed and The Petroleum and Explosives Saftey Organisation (PESO) Approved Cylinders ,complete with UL Iisted valve assembly and including supervisory switch connection for monitoring cylinder pressure , pressure operated control head,flexible hose, strap ,NRV and a safety cap.(all accessories should be UL listed with UL marking and from same OEM Note : Gas (Quantity would be as per the volume given below and as per the UL certicication) CLEAN AGENT Like Per flouro-ketone, Penta flouro-ethane, Hepta-floro-Propane(HFC 227ea/HFC 125)(UL listed )with zero Ozone depletion potential(ODP) has apperiance /colour. Colourless gas and has citrus like odour.( Gas should be filled in UL listed and PESO approved filling station) Note :- Before commissioning of automatic fire suppression system , it shall be checked for its functionality by using Nitrgen or other dummy gases.
Room -09 & Room 10 (vol -95 cum) 1x67.5 Litres (Cylinder size as per manufacture 's Listing) Cylinder filled with HFC 125 (51 kgs approx)
Room -12 (vol -188 cum) 1x120 Litres (Cylinder size as per manufacture 's UL Listing) Cylinder filled with HFC 125 (101 kgs approx)
Room -13 (vol -100 cum) 1x67.5 Litres (Cylinder size as per manufacture 's UL Listing) Cylinder filled with HFC 125 (53 kgs approx)
Supply, installation, testing and commissioning of piping with ASTM sch. 40 pipe as per design requirement complete with welding work with Required size making good the damages etc as reqd .Rate quoted include fixing with wall /supension from ceiling etc for the following size as under :-
65 mm dia of pipe
50 mm dia of pipe
40 mm dia of pipe
32 mm dia of pipe
25 mm dia of pipe
20 mm dia of pipe
15 mm dia of pipe
Supply Fabrication and commisioning of manifold for marking header of Gas cylinder Complete all as specified and directed.
Supply ,installation ,testing and commissioning of Microprocessor Based Two Loop analogue addressable type fire alarm control panel with 80 chracter LCD display four access levels 500 event historical logging complete all as specified and directed.
Supply ,installation ,testing and commissioning repeater Panel complete all as specified and directed.
Supply ,installation ,testing and commissioning of Aspiration based Smoke Detection Unit with four pipe inlet capable for identifying pipe under alarm ,four channel aspirtation detector with Up to 100 m (382 ft) per sampling pipe . The unit should be UL and VDS approved complete with display of all alarms ,detection technology shall be Laser based having closed/sealed maintenance free detection chamber to avoid any possible contamination during manual maintenance on board 20,000 event log memory without need of any external memory card .Alarm Threshold Setting Range: 0.005-20.00 % obs/m ( 0.0016-6.10 obs/fit)
Supply ,installation ,testing and commissioning of Aspiration based Smoke Detection Unit with six pipe inlet capable for identifying pipe under alarm ,six channel( 3+3/4+2) aspirtation detector with Up to 100 m (382 ft) per sampling pipe . The unit should be UL and VDS approved complete with display of all alarms ,detection technology shall be Laser based having closed/sealed maintenance free detection chamber to avoid any possible contamination during manual maintenance on board 20,000 event log memory without need of any external memory card .Alarm Threshold Setting Range: 0.005-20.00 % obs/m ( 0.0016-6.10 obs/fit)
Supply ,installation ,testing and commissioning of power supply Unit for above detactor 230 V AC to 24 V DC 3 Amp .Power Supply should be with 24 hour
Supply Installation ,Testing and commissioning of Aspirating Tube ,capilary Tube Nozzle ,accessories etc.
Supply ,installation ,testing and commisioning of 25 mm dia FRLS pipe for Aspiration detectors complete all respect as required
Providing & fixing Gas Release Panel/Built in Module with 2-Zone fire detection and 1-Zone gas discharge module with binary switch timer for release delay and potential free contact to relay "Gas Release'signal to main panel (UL Listed)
Supply ,Installation Testing and commisioning of Addressable multicrteria smoke detector ,Address Switch to progrmme the modules from 01-99 ,complete as as required as per sepcifications
Supply ,Installation ,Testing and commissioning of Addressable Manual Call point Address Switch to programme the Manual Pull Station from 01-99 complete as required as per secifications.
Supply ,Installation ,Testing and commissioning of Sounder with 65-120 db(A) output at 1.5 meter distance cum Strobe Lights with 110 cd as per specification complete as required with power supply .
Supply ,Installation ,testing and commissioning of Addressable control module for Hooter ,Address switch to programme the modules from 01-99,complete as required as per specification
Supply ,Installation ,Testing and commissioning of Addressable monitor modules for aspirtation detection system ,Address Switch to programme the modules from 01-99,complete as required as per sepcifications
Supply of Addressable relay module for Cross Zoining ,Address Switch to programme the modules from 01-99 complete as required as per specification
Supply ,Installation ,Testing and commissioning of Fault lsolator Module for isolating shorted ,dewired and loose circuits between two successive fault isolators with automatic resetting arrangememnt
Supply ,installation ,Testing and Commisioning of Manual Abort Station (Pull Type ) complete all as specified and directed.
Supply ,Lnstallation ,Testing and Commisioning of Manual Release Station (Pull Type ) complete all as specified and directed.
Cable tray as required size complete all as specified and directed.
Photoluminiscent Gas Release caution sign board complete with fxing arrangements complete all as specified and directed.
Providing Electric Gas Release caution sign board (24 V DC ) for approved locations complete all as specified and directed.
Supply ,Installation ,Testing and Commissioning of 2Cx1.5 sqmm fire Survival armoured cable complete all as specified and directed.
Supply ,installation ,testing and commissioning of Emergerncy Lighting Control Panel with two lighting lines with maximum of 254 devices on both line ,up to 127 devices per line length 500/1000 Meters.The System shall work on extra low voltage and shall be addressable complete all as specified and directed.
Supply ,installation ,testing and commissioning of ELS (Emergency lighting system ) Panel Transformer 230 V with an output of 35V AC and is placed between mains and ELS Control panel complete all as specified and directed.
Supply ,installation ,testing and commissioning of Key pad with an LCD to control and read the Main ELS Control Panel complete all as specified and directed.
Addressable Exit Signage visible from 2D mtrs with integral battery capacity of 3 hrs and bicoloured LED status indicator . Available in Left , Right , Down signs with batteries incorporated into each luminaries shall be Polynmer Lithium Ion technology and incorporate over voltage , over current and deep discharge protection circuitry . Provides at least 3 hours luminaires operation when full charged.
Supply ,installation ,testing and commissioning of Addressable Closed Area LED Down lighter with integral battery capacity of 3 hrs ans bicoloured LED status indicator complete all as specified and directed.
Supply ,installation ,testing and commissioning of Addressable Open Area LED Down Iighter with battery capacity of 3 hrs and bicoloured LED status indicator complete all as specified and directed.
Supply & testing of screened and twisted single pair 1.5 Sqmm 2core copper cable complete all as specified and directed.
Supply ,Installation,Testing and Commissioning of (19"width x24 Depth) standard alluminium Box with front Acylic door and lock ,rear door with lock ,two fans for Ventilation with side panel lovered ,castor wheels pre-wired power and signal Channel duly powder coated with Gray paint complete all as specified and directed.
Supply ,Installation ,Testing and Commissioning of the controller with buit-in 240 W amplifier ,12 business and emergency control inputs and supporting 6 zones complete all as specified and directed.
Supply ,Installation,Testing and commissioning of the four/Six-zone router with single or dual Channel operation with six EMG input contacts ,six business input contacts, six volume override output contacts ,supervision within the Voice Alarm System complete all as specified and directed.
Supply ,Installation,testing and commissioning of 240W power amplifer in a 2U high housing with 70 V/ 100 V and 8 ohm outputs ,Dual inputs with priority switching 100 V input for slave operation on 100 V speaker line ,Mains ,battery back -up and pilot tone supervision complete all as specified and directed.
Supply ,Installation,testing and commissioning of 6 watt ceiling mounted Speakers complete all as specified and directed.
Supply ,Installation,testing and commissioning of 2C x 1.5 sq.mm fire Survival unarmoued cable complete all as specified and directed.
Supply, installing, commissioning and testing complete of manufacturer or OEM (Original equipment Manufacturer) manufactured and tested silent static Diesel Engine driven generating set capacity of 400 KVA continuous rating 10% overload for 1 hour in 12 hours of operation) 415 volts ( AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG Set shall consist of a diesel engine coupled directly to a matching alternator and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure compete with control panel standardized by manufacturer, fuel tank with mounting arrangement and inlet, outlet return oil arrangement, flexible exhaust pipe complete all as specified and shall comprises of the following:-
(i) Engine (prime mover): Diesel engine 1500 RPM, of suitable BHP, fluid cooled, turbo changed, volts electric 02 numbers maintenance free batteries complete with fly wheel and vibration damper, radiator and all standard fittings /fixture as per standard manufacturing design practices and including suitable instrument panel with RPM meter, lubricant oil temperature & pressure gauge, water temperature gauge and frequency meter (digital type) battery charging ammeter and fuses and also including self starter (24V), battery charging alternator, fuel tank etc and complete with HWT & LLOP alarm and shut down safeties. (ii) Alternator AC alternator, brushless, 415V, AC 50 Hz 3 phase, 4 wire type, rated for continuous outlet of 400 KVA, PF 0.8, 1500RPM insulation class ‘H’ enclosure SPDP (IP23) self excited & self regulated with AVR for + 1 voltage regulation, coupled directly/ suitable to and match the above engine. (iii) Base plate: Made out of structural steel as per manufacturer’s recommended design/specifications. (iv) Fuel tank: fuel tank shall be of 24 hours capacity, made of 14 Gauge CRCA MS Sheet, duly powder coated and provided with level indicator, drain plug, air vent float, gauge and fuel float switch. (v) Safeties: for high enclosures temperature and emergency shut-down from outside. 2 numbers 180AH, 24V lead acid batteries and adequate size copper conductor cable leads.
(vi) Engine control panel: Made of 14 gauge CRCA MS sheet dust and vermin proof, (protection class IP 41 or superior) duly fitted with the equipment/ metres specified in particular specification. (vii) Automatic mains failure (AMF) control panel : fabricated from minimum 14 gauge CRCA steel sheet (including CPRI type certified) dust & vermin proof protection class IP-54 suitable for 414 volts , 3 phase 4 wire , 50 Hz AC supply system with adequate layers of powder coating floor mounting type with front opening & panel shall comprises of all necessary accessories as per complete of manufacturer or OEM including one number onload change over switch 630 Amps, 04 pole, 415 volts, 50 Hz with front operated rotary handle for by pass arrangement of electric supply to be fixed by manufacturer in AMF panel. (viii) Platform/Plinth/Base : Shall be provided as per manufactures recommendations, however minimum 1.0 meter space should be available all around the DG Set and height of plinth shall not less than 0.5 meter. (ix) Tool kit: Operation and Maintenance catalogue 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacture standard practices. (x) Make of Engine : Cummins , Caterpillar , Greaves Make of Alternator : Stamford , Croplton Greaves , Caterpillar
M&L for earthing complete with Galvanised earth plate electrode 600x600x6mm thick buried directly in ground (earth) pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel of size 75mm x 75mm x 25mm, supplying and laying charcoal stone aggregate) chamber and mild steel angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia TMT BARS @ 75mm O/O both ways with mild steel handle 12mm dia, PGI funnel with wire mesh, 20 MM dia GI pipe light grade for watering all as shown in electrical plate No.3 of MES SSR Part - 1( 2009) and connected in earth test including testing completed all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth work (Exe , Returning, Removel) , Earth test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
M&L for earthing complete with Galvanised earth plate electrode 600x600x6mm thick buried directly in ground (earth) pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised iron wire 4 mm as earthing lead by means of bolts, nuts, check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanised Iron/steel of size 75mm x 75mm x 25mm, supplying and laying charcoal dust ,common salt , PCC 1:2:4 type B-1 chamber and mild steel angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with mild steel handle 12mm dia, PGI funnel with wire mesh, 20 MM dia GI pipe medium grade for watering all as shown in electrical plate No.3 of MES SSR Part - 1( 2009) and connected in earth test including testing completed all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth work (Exe , Returning, Removel) , Earth test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
M&L for earthing complete with Galvanised earth plate electrode 600x600x6mm thick buried directly in ground (earth) pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel of size 75mm x 75mm x 25mm, supplying and laying charcoal stone aggregate) chamber and mild steel angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia TMT BARS @ 75mm O/O both ways with mild steel handle 12mm dia, PGI funnel with wire mesh, 20 MM dia GI pipe light grade for watering all as shown in electrical plate No.3 of MES SSR Part - 1( 2009) and connected in earth test including testing completed all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth work (Exe , Returning, Removel) , Earth test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
TRIVENI CONSTRUCTIONS
Leo Air and Power Solution pvt Ltd.
BRITE INDUSTRIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .