Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | ₹36.0 L Quoted ₹37.4 L | L1 | Accepted-AOC Accepted being lowest as per NIT |
| 2 | L2₹43.9 LRejected-Finance | ₹43.9 L | L2 | Rejected-Finance Rejected being L2 bidder |
| Sl No | Description | Qty | Unit | M/S Sky Engineers L2 | VEDA INFRASTRUCTURE L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for dehydration and filteration of existing transformer oil of Power transformer of capacity 1 MVA to 8 MVA and distribution transformer of capacity 63 KVA to 630 KVA using transformer oil filteration plant to eliminate moisture and foreign particles till upto achieving improved di-electric strength of oil upto 45 KV (minimum) at a 2.5mm electrode gap and to bring the acidity within the permissible limit below 0.5 mg KOH/Cm all as specified and directed.
Note: Transformer oil filteration & dehydration by Ultra High Vacuum double stage machine should be done on existing installation place on same day and report of the same be obtained from the vendor. | 25,000 | Ltrs | 15 ₹3,75,000 | 3 ₹75,000 Lowest |
| 2.00 | M&L for topping up of power transformer oil having BDV value not less than 60 complete all as specified and directed. | 4,600 | Ltrs | 90 ₹4,14,000 Lowest | 90 ₹4,14,000 Lowest |
| 3.00 | S&F in repair/ renewal Epoxy Arm-01 No for power transformer 6.3 MVA/1 MVA (OLTC), AC 3 phase, outdoor type for following items complete all as specified and directed. | 1 | Each Set | 1,000 ₹1,000 Lowest | 1,000 ₹1,000 Lowest |
| 3.01 | Supply only transit resistance coil-03 Nos | 1 | Each Set | 1,000 ₹1,000 | 500 ₹500 Lowest |
| 3.02 | Supply only main moving contact-03 Nos | 1 | Each Set | 1,500 ₹1,500 | 500 ₹500 Lowest |
| 3.03 | Supply only Arc/resistance contact-03 Nos | 1 | Each Set | 1,200 ₹1,200 | 500 ₹500 Lowest |
| 3.04 | Supply only OLTC Auxiliary PVC insulated armoured copper cable 4 core 25 sqmm 1100 volt
Note: For all supply only item shall be deemed inclusive in quoted rate of item No 03. | 30 | RM | 800 ₹24,000 Lowest | 800 ₹24,000 Lowest |
| 4.00 | S&F in renewal transformer protection and control relay installed in CR panel consisting with voltage-24-60V VDC current-1 A &5 A Diff port low stage , Diff Port high stage, over current relay, restricted earth fault, Earth fault, Breaker Failure, NPS of thermal overload, disturb rec. triggered etc. complete all as specified and directed.
Make: ABB cat part No RET615 or equavalent in L&T /SCHIENDER. | 1 | Each | 1,60,000 ₹1,60,000 Lowest | 1,70,000 ₹1,70,000 |
| 5.00 | S&F in renewal of earth fault and over current relay suitable for 11 KV VCB complete all as specified and directed.
Make: As per existing model CG cat part No CGI 14N or equavalent in L&T/ ABB/SCHIENDER | 4 | Each | 20,000 ₹80,000 | 8,000 ₹32,000 Lowest |
| 6.00 | S&F in renewal of master trip relay 24 V, DC suitable for 11 KV VCB complete all as specified and directed.
Make: As per existing model Avana cat part No EMR151 or equavalent to L&T/ SCHIENDER. | 4 | Each | 1,500 ₹6,000 Lowest | 4,000 ₹16,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Jun 2026, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, C/O 56 APO, PIN- 914133
CWEK-____/864 EWS/2026-27 DEHYDRATION OF POWER TRANSFORMER, CALIBRATION OF 33 KV VCB, SERVICING OF CTs, PTs AND GOD, BUS BAR INCLUDING CONNECTED WORK AT MRS UNDER GE 864 EWS
2026_MES_765340_2
CWEK-____/864 EWS/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 864 EWS
Class D and above and Category b (iii)
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹96,000
13 Aug 2026
8 Jun 2026
30 Jun 2026
8 Jun 2026
22 Jun 2026
15 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for dehydration and filteration of existing transformer oil of Power transformer of capacity 1 MVA to 8 MVA and distribution transformer of capacity 63 KVA to 630 KVA using transformer oil filteration plant to eliminate moisture and foreign particles till upto achieving improved di-electric strength of oil upto 45 KV (minimum) at a 2.5mm electrode gap and to bring the acidity within the permissible limit below 0.5 mg KOH/Cm all as specified and directed.
Note: Transformer oil filteration & dehydration by Ultra High Vacuum double stage machine should be done on existing installation place on same day and report of the same be obtained from the vendor. | 25,000 | Ltrs | - | - |
| 2 | M&L for topping up of power transformer oil having BDV value not less than 60 complete all as specified and directed. | 4,600 | Ltrs | - | - |
| 3 | S&F in repair/ renewal Epoxy Arm-01 No for power transformer 6.3 MVA/1 MVA (OLTC), AC 3 phase, outdoor type for following items complete all as specified and directed. | 1 | Each Set | - | - |
| 3.01 | Supply only transit resistance coil-03 Nos | 1 | Each Set | - | - |
| 3.02 | Supply only main moving contact-03 Nos | 1 | Each Set | - | - |
| 3.03 | Supply only Arc/resistance contact-03 Nos | 1 | Each Set | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
Tender11.pdf
Tender Documents • 1.22 MB
BOQ_862735.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].