| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | ₹3.7 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹4.4 L+₹70,332.72 (18.8%)Rejected-Finance | ₹4.4 L+₹70,332.72 (18.8%) | L2 | Rejected-Finance Rejected as not L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected as per NIT |
| 4 | Rejected-Technical BHARECH NAGAR SANDI NEAR MIDAS TYRE RAMGARH 829117 JHARKHAND INDIA | RAMGARH | RAMGARH | JHARKHAND | 829117 | - | - | Rejected-Technical Rejected as per NIT |
| 5 | Rejected-Technical AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | - | - | Rejected-Technical Rejected as per NIT |
| Sl No | Description | Qty | Unit | M/S P. L. CONSTRUCTION L1 | M/s. M K ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductorsingle core cable in surface/Recessed PVC conduit, with piano type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cableetc. as required. (Group –“B”) | 52 | Nos | 800 ₹41,600 Lowest | 950 ₹49,400 |
| 1.02 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required(2x1.5Sq.mm+ 1.5sq.mm earth wire) | 263 | Mtr. | 125 ₹32,875 Lowest | 195 ₹51,285 |
| 1.03 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire | 139 | mtr | 200 ₹27,800 Lowest | 230 ₹31,970 |
| 1.04 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required. 2 x 6 sq.mm + 1 x 6 sq. mm earth wire | 97 | mtr | 325 ₹31,525 Lowest | 375 ₹36,375 |
| 1.05 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required. 2 x 10 sq.mm + 1 x 10 sq. mm earth wire | 44 | mtr | 450 ₹19,800 Lowest | 487 ₹21,428 |
| 1.06 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 5/6Amps.switch | 38 | Nos | 50 ₹1,900 Lowest | 65 ₹2,470 |
| 1.07 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 5/6Amps. Socket outlet | 23 | Nos | 90 ₹2,070 Lowest | 102 ₹2,346 |
| 1.08 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 15/16 Amps Switch | 12 | Nos | 100 ₹1,200 Lowest | 132 ₹1,584 |
| 1.09 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 15/16 Amps Socket outlet | 12 | Nos | 150 ₹1,800 Lowest | 167 ₹2,004 |
| 1.10 | Supplying and fixing of modular type electronic regulator Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. | 26 | Nos | 300 ₹7,800 Lowest | 315 ₹8,190 |
Tender Value
₹4.4 L
EMD Value
₹5,500
Closing Date
19 Dec 2025, 11:00 amClosed
Staff Officer(ENM),Kathara Area
Office of the Staff Officer(ENM),Kathara Area AT KATHARA DIST BOKARO
Providing and laying of Power cable with control switch , bus bar, earth pit and electrical repairing / rewiring of some damaged point of (sr. wing) at DAV PUBLIC SCHOOL SAWANG under kathara Area
2025_CCL_348910_1
GM(KTA)/SO(EnM)/e-Ten/25-26/25 DT05.12.2025
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Kathara Area
AS PER NIT
5 documents required · 5 mandatory
₹5,500
13 Aug 2026
5 Dec 2025
20 Dec 2025
6 Dec 2025
19 Dec 2025
6 Dec 2025
6 Dec 2025 - 17 Dec 2025
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductorsingle core cable in surface/Recessed PVC conduit, with piano type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cableetc. as required. (Group –“B”)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required(2x1.5Sq.mm+ 1.5sq.mm earth wire)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required. 2 x 6 sq.mm + 1 x 6 sq. mm earth wire
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required. 2 x 10 sq.mm + 1 x 10 sq. mm earth wire
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 5/6Amps.switch
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 5/6Amps. Socket outlet
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 15/16 Amps Switch
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. 15/16 Amps Socket outlet
Supplying and fixing of modular type electronic regulator Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
Supplying and fixing metal box of 150mm X 75nnm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outletand 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplyingand fixingPVC batten/ angle holder including connections etc as required.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(4 pole MCCB, 100A, 30KA)
Supplying and fixing of following sizes of medium class PVC conduit/ cashing along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.(20mm dia PVC conduit/ cashing )
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Details of cost for 1 Metres
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr. long etc. with charcoal/coke and salt asrequired.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing following rating, double pole, (single phase and neutral),240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing of 1.1kv 3 core 6 sq mm copper cable pvc armoured etc. as required
Providing of change over switch 100Amp, 4 pole 415volts
Providing of 3 pole main swich fuse unit 415volts 100 amp etc. as required
Providing of 2.5 sqmm pvc unarmoured cable twin core cpper for park light connection
Laying of one number additional PVC insulated and PVC sheathed! XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.( 86 mtr +32 mtr departmental supply 35 sqmm alluminium cable 3 core armured 1.1 kv grade)
Labour charges in Sl. No. 23 &24 and other expenses
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.28 MB
BOQ_361646.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .