Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
2 Sept 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dharmendra Kumar
RHQ, NR1, SCO BAY 5-10, SECTOR-16, FARIDABAD-121002, HARYANA
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai
NR1/NT/S-MISC/DOM/I00/24/07273
Open
Civil Works – General
Fixed-rate
New Delhi
Applicable as per Annexure-A (BDS) of Vol-I of tender documents (RFX-5002003566)
₹25,000
₹5 L
5 Aug 2024
5 Aug 2024
4 Sept 2024
5 Aug 2024
2 Sept 2024
5 Aug 2024
Package Name Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Package Code RFX-5002003566
Specification No. Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
1 Fill up only green shaded cells in Sch-3 and Sch-Discount (if any) and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-4b (Maintenance Charges during and after Defect Liability Period) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Not applicable, hence no cell is required to be filled up.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Sole Bidder 1 Sole Bidder 1
Joint Venture 2 or More JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 1 0 Sole Bidder 1 0
Name of Sole Bidder …….. …….. …….. …….. …….. ……..
Address of Sole Bidder …….. …….. …….. …….. …….. ……..
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
PLANT AND EQUIPMENT (INCLUDING MANDATORY SPARES PARTS) TO BE SUPPLIED, INCLUDING TYPE TEST CHARGES FOR TESTS TO BE CONDUCTED Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘ 6 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST Tax as confirmed by Bidder
PART A (Substation Portion)
I Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 28 Included 0.00 0 0.00
23 28 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
II Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 18 Included 0.00 0 0.00
23 18 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
III Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 18 Included 0.00 0 0.00
23 18 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
IV Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
Total Ex-works Price 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 2
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
LOCAL TRANSPORTATION, IN-TRANSIT INSURANCE, LOADING AND UNLOADING
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & unloading Charges Total Freight, In-transit Insurance, loading & unloading Charges
PART A (Substation Portion)
Total F&I Price 0.00
Place: Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 2 Dis
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 3
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
CIVIL & ELECTRICAL WORKS Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
PART A (Substation Portion)
CIVIL WORKS Revaluation of J column Tax Calculation
A SUB HEAD: DISMANTLING AND DEMOLISHING 0.00 0.00
1 Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include but are not limited to, flooring, false ceiling, tiling, partitions, panelling, cladding, brickwork, concrete, RCC, plumbing, internal doors, internal windows, glazing, metal work, cabinetry, electrical work, sanitary work, light fittings, switches, cabling, fire fighting lines and risers. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal. 0 0
1.1 18 Ground Floor Wings B with Toilet Block sqm 304.00 Included 0.00 0 0
1.2 18 Third Floor Wing A and B sqm 370.00 Included 0.00 0 0
1.3 18 Third Floor Wings C and D sqm 442.00 Included 0.00 0 0
1.4 18 Third Floor Reception and Central Zone sqm 93.00 Included 0.00 0 0
1.5 18 Third Floor Toilet Block sqm 32.00 Included 0.00 0 0
1.6 18 External paver blocks and allied works sqm 3000.00 Included 0.00 0 0
2 Credit to the CLIENT for usable/unusable material that is recovered and disposed off from within the premises. Bidders MUST visit the premises and ascertain the items against which credit may be due. 0 0
2.1 18 Ground Floor Wings B with Toilet Block LS -1.00 Included 0.00 0 0
2.2 18 Third Floor Wing A and B LS -1.00 Included 0.00 0 0
2.3 18 Third Floor Wings C and D LS -1.00 Included 0.00 0 0
2.4 18 Third Floor Reception and Central Zone LS -1.00 Included 0.00 0 0
2.5 18 Third Floor Toilet Block LS -1.00 Included 0.00 0 0
3 18 Dismantling of the ACP sheet on out side building area including filling the joints with black colour silicone etc complete as per site conditions sqm 12.41 Included 0.00 0 0
B. SUB HEAD: MASONARY WORK 0 0
4 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) cum 5.36 Included 0.00 0 0
5 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) cum 62.45 Included 0.00 0 0
6 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). cum 1.00 Included 0.00 0 0
7 18 Steel Reinforcement: Thermo-Mechanically Treated bars of grade Fe-500D or more kgs 80.00 Included 0.00 0 0
8 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) cum 16.62 Included 0.00 0 0
9 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) sqm 174.03 Included 0.00 0 0
10 18 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. sqm 174.03 Included 0.00 0 0
11 18 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) sqm 95.96 Included 0.00 0 0
12 18 12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) sqm 95.96 Included 0.00 0 0
13 18 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) sqm 62.05 Included 0.00 0 0
14 18 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window sqm 12.41 Included 0.00 0 0
15 18 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. sqm 102.05 Included 0.00 0 0
16 18 Filling of sunken portion of the toilet area with Brick bats including compacting etc complete as per site conditions. Cum 21.44 Included 0.00 0 0
C SUB HEAD: STEEL WORK 0 0
17 18 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete Kg 2331.00 Included 0.00 0 0
18 18 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 261.00 Included 0.00 0 0
19 18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. Kg 10.00 Included 0.00 0 0
20 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 0 0
20.1 18 M.S. tube Kg 26.10 Included 0.00 0 0
21 18 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Kg 2000.00 Included 0.00 0 0
22 18 Providing and fixing 10mm thk toughened plain glass to be fixed to the stainless steel railing on D-brackets as per direction of Engineer In charge to the required shape and size. (For stairs) Sqm 100.00 Included 0.00 0 0
D SUB HEAD: Finishing 0 0
23 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 0 0
23.1 18 Granite of any colour and shade (Area of slab upto 0.50 sqm) sqm 128.73 Included 0.00 0 0
23.2 18 Granite of any colour and shade (Area of slab over 0.50 sqm) sqm 112.23 Included 0.00 0 0
24 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 0 0
24.1 18 Granite work metre 15.26 Included 0.00 0 0
25 18 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. metre 15.26 Included 0.00 0 0
26 18 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. each 14.00 Included 0.00 0 0
27 18 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sqm 254.34 Included 0.00 0 0
28 18 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours as per the instructions of EIC, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. sq.m. 82.79 Included 0.00 0 0
29 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 0 0
29.1 18 Size of Tile 600x600 mm sqm 1.00 Included 0.00 0 0
29.2 18 Size of Tile 800x800 mm sqm 1.00 Included 0.00 0 0
29.3 18 Size of Tile 1000x1000 mm sqm 1.00 Included 0.00 0 0
30 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 0 0
30.1 18 Size of Tile 600x600 mm sq.m. 956.40 Included 0.00 0 0
30.2 18 Size of Tile 800x800 mm sq.m. 478.20 Included 0.00 0 0
30.3 18 Size of Tile 1000x1000 mm sq.m. 956.40 Included 0.00 0 0
31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 0 0
31.1 18 Size of Tile 600x600 mm sqm 956.40 Included 0.00 0 0
31.2 18 Size of Tile 800x800 mm sqm 478.20 Included 0.00 0 0
31.3 18 Size of Tile 1000x1000 mm sqm 956.40 Included 0.00 0 0
32 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixingAccess Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade(FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 0 0
32.1 18 300 mm Finished Floor Height (FFH) sqm 40.00 Included 0.00 0 0
33 18 Providing and fixing machine cut, mirror polished, Italian Marble stone on walls in required pattern, all complete as per architectural drawings, with 18 mm thick stone slab laid with cement based high polymer modified quick set adhesive (water based) conforming to IS: 15477, in average 6 mm thickness and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Basic Rate of stone is Rs.3767/- per sq.m. Pre-approved chemical Adhesive - for fixing on cement plaster use Keraflex Maxi S1 by Mapei. sq.m. 33.45 Included 0.00 0 0
34 18 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.: 18 mm thick. Italian Marble stone slab. Basic Rate of stone is Rs.3767/- per sq.m. sqm 50.82 Included 0.00 0 0
35 18 Providing and laying 8mm thk Laminated Wooden flooring of approved make in a design combination as per the drawing and instructions on levelled floor, insulating the areas, surface preparation, bedding, finishing etc complete as per the directions and instructions of the Engineer-in-charge. The rate shall be inclusive of edge moulding and end strips at the junction between the floor and the vertical surfaces and mouldings, T grooves and shall also include the underlays as per manufacturers specifications to achieve accoustical and thermal insulating properties etc complete. Basic Rate of Wooden laminates is Rs.3000/- per sq.m. sqm 181.33 Included 0.00 0 0
36 18 Providing and fixing 75mm high skirting in required position to be screewed to the existing walls, panelling surfaces, partitions etc including pre polished moulding etc complete as per manufacturers specifications and directions of EIC.: Laminated Wooden skirting. Basic Rate of Wooden laminates is Rs.3000/- per sq.m. sqm 13.66 Included 0.00 0 0
37 Providing and fixing Panelling on Walls, Columns, Ducts, Around Shafts etc comprising of 50.8x25.4x2.03 Aluminium rectangular hollow sections framing at a maximum spacing of 600 mm centre-centre bothways with 12mm thick Exterior Grade Particle Board. All the members shall be screwed with stainless steel screws rawl plugs etc complete required for fixing frame. All Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically. All the materials like cleat angles, mouldings, beading,.etc complete. The rate shall also include the teak wood beeding and moulding to be melamine polished including raised panels with 6mm thk ply backing wherever directed, t.w moulding etc complete. All works shall be carried out as per . drawings and the directions of Engineer-in-charge. 0 0
37.1 18 Finished with 4.0 mm thk approved Veneer with Melamine polish of approved grade as per the drawing including designed grooves etc complete. sqm 212.82 Included 0.00 0 0
37.2 18 Finished with 1.5 mm thk approved laminate as per the drawing including designed grooves etc complete. sqm 91.21 Included 0.00 0 0
38 18 Providing and fixing of 6mm thick annealed Saint Gobain Planilaque Evolution (premium GRIHA rated lacquered glass from Saint-Gobain) or of approved equivalent, fixed with SGG PlaniFIX (compatible neutral core silicon / double sided tape) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. Lacquered glass must be made industrially (via curtain coating process); opaque (if viewed against a support wall), coated with PU lacquer ; color consistency (measured by Minolta spectrophotometer CM5081); highly durable (passes PERSOZ hardness test for minimum 220 oscillatios); humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strenght (1000 MPa) & tensile strenght (40 MPa),same as float glass as per the detailed drawings and as approved by Engineer In Charge. (Lacquare Glass Panelling) Sqmt 53.76 Included 0.00 0 0
39 18 Single Glazed 12mm Toughened Glass Partition - With Alexa 100 Frame Profiles (with glass) Supply and Fixing of Single Glazed Glass partition of 12mm Toughened Glass using dormakaba Alexa System-100 Frames to a height of maximum 4m or as per drawing.The Fixed glass to be fixed using dormakaba Alexa BP100 Profiles at Top & Bottom & Alexa SP100 at sides. The profile size to be 100x25MM to be fixed on to the floor/wall/ ceiling as per the architect design.dormakaba Alexa H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design.In case of Glass overall panel Alexa OHP100 Overpanel Profile to be used.In case of Open glass edges EP100 End Profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles/Frames: dormakaba Glass : Saint Giobain/Asahi sqm 34.43 Included 0.00 0 0
40 18 Providing and fixing of Frosted Film 80 micron with adissive Permanent acrylic having UV Temperature, Humidity and salt sprey resistance. Create a translusant privacy of desired size as per the direction of Engineer-in-charge. 3M / Garware Sqm 34.43 Included 0.00 0 0
41 Providing and fixing full height double skin partitions with 12mm thk Exterior Grade Particle Board on both sides of the aluminium frame as per drawings. Main frame shall be made of aluminium square hollow section 50.8x50.8x2.4 mm and other horizontal and vertical members shall be made of aluminum rectangular hollow section 50.8x25.4x2.03 at a maximum spacing of 600 mm centre-centre including cleat angle etc. complete wherever required. All the members shall be screwed with stainless steel screws and main frame shall be fixed with rawl plugs etc complete required for fixing the partition frame to the wall or ceiling. All Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically. All works shall be carried out as per drawings and the directions of Engineer-in-charge. 0 0
41.1 18 Both sides of the partition finished with 4.0 mm thk approved veneer, finished with melamine polish of approved grade as per the drawing including designed grooves etc complete. sqm 140.04 Included 0.00 0 0
41.2 18 Both sides of the partition finished with 1.5 mm thk approved laminate as per the drawing including designed grooves etc complete. sqm 60.02 Included 0.00 0 0
42 18 Providing & fixing Urinal Modesty Panels having standard dimension of 1200 mm Height x 450 -500 mm Width and 12 mm thickness(Greenlam Sturdo of Greenlam Industries Ltd /SS Series of Merino Industries or approved equivalent) Panel starts 500-600 mm above ground level, complete with compact Laminate Board: 12 mm thick Compact Laminate (Greenlam Sturdo of Greenlam Industries Ltd /Titan Series of Merino Industries or approved equivalent) made as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard and should be heat, bacteria, water, chemical, scratch and impact resistant 12 mm thick solid compact laminate panels as per approved texture/shade. The product should have Green Guard Certificate. Including all accessories as per approval and direction of Engineer-in-Charge Modesty panels will be fixed with right angle bracket which will provided in stainless steel grade-304. (a) Right Angle Bracket b) Screws & Wall Plugs. Hardware & Fixing Nos 6.00 Included 0.00 0 0
43 18 Providing and fixing of Acoustic wall panel 600x600x25 mm shapes as per drawings, with standard fabric approved by the architect with fixing system. Colour and texture of fabric as per selection by Architect. Gyproc / Saint gobin / Armstrong sqm 67.23 Included 0.00 0 0
E. SUB HEAD: ROOFING/CEILING 0 0
44 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 0 0
44.1 18 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) sqm 469.00 Included 0.00 0 0
44.2 18 12.5 mm thick tapered edge gypsum moisture resistant board sqm 64.40 Included 0.00 0 0
45 18 Extra for above items for necessary designs and patterns in curvature, paragons, sloping, domes of any type, oval, domes with fins on all sides, reverse curves and eliptical shaped etc including the necessary provisions of coved lighting scheme, necessary frame work and supporting arrangement etc complete as per the designs, drawings and instructions of the Engineer-in-charge. No extra amount on account of any shape or design shall be entertained and the quoted rate shall be inclusive of all such designs and shapes including finishing. sqm 93.80 Included 0.00 0 0
46 18 Providing & fixing horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black / White). The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5% at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing of 100mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. Knauf/Gyproc/Armstrong make or equivalent sqm 25.00 Included 0.00 0 0
47 18 Extra for providing for suspension system hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60-80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. sqm 25.00 Included 0.00 0 0
48 18 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. sq.m. 497.00 Included 0.00 0 0
49 18 Making Grooves of size upto 15mm wide and 5mm deep in POP punning in straight lines and sharp edges as per pattern in drawings by architect. mt 100.00 Included 0.00 0 0
50 18 VENEER FALSE CEILING: Providing and erecting false ceiling in veneer with 12 mm thk commercial ply board backing on teak wood frame to be anchored to the main ceiling with cross runners tongued and grooved. The ply to be finished with approved 4mm thk veneer and melamine polish etc. complete as per directions of the Engineer-in-charge sqm 50.00 Included 0.00 0 0
51 18 Providing and fixing reflective sun control film of approved make and shade to the existing glasses as per the drawings, details and instructions of Engineer-in-charge including the adhesives etc complete. sqm 180.54 Included 0.00 0 0
F. SUB HEAD: PAINTING WORK 0 0
52 18 Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. sq.m. 608.81 Included 0.00 0 0
53 Finishing walls with textured interior paint of required shade : 0 0
53.1 18 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 150.00 Included 0.00 0 0
54 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete 0 0
54.1 18 On steel work sqm 50.00 Included 0.00 0 0
54.2 18 On concrete work sqm 100.00 Included 0.00 0 0
55 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 0 0
55.1 18 Two or more coats on new work Sqm 120.00 Included 0.00 0 0
56 18 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 82.77 Included 0.00 0 0
57 18 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. sqm 1267.81 Included 0.00 0 0
58 Two coats 0 0
58.1 18 Melamine polishing on wood work (one or more coat) sqm 100.00 Included 0.00 0 0
59 18 Providing and fixing of Wallpaper Non Woven heavy-weight 350 GSM latex saturated size 53 cmx 10 m roll including installation with required adhesive, (Artisan wall coverings/ UDC make wallpaper. Adhesive make: Bartoline) sqm 12.83 Included 0.00 0 0
G. SUB HEAD: Aluminium Composite Panel 0 0
60 18 Fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall withAluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. sqm 13.65 Included 0.00 0 0
61 18 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). Kg 75.08 Included 0.00 0 0
H. SUB HEAD: Curtain Blinds 0 0
62 18 Providing and Installing Roller Blinds with Max Width 250 cm. Length availiable as per window size. All color ready. 100 % dark Including installation at site, with Control unit of high strength of reinforced plastic with clutch of wrap spring design with high carbon steel springs for transmit motion from drive to drive members of clutch mechanism with clutch to be operated by use of endless beeded chain to rise smoothly to the required height with idler in reinforced plastic of an outside sleeves and centre to rotate freely, smoothly and long wearing operations. Both control unit and idler to be mounted on head rail with M.S brackets (Powder coated) and operating chain of 4.5mm dia and 6mm pitch and brackets to be 2mm M.S, zinc coated and clamped on 0.5mm spring steel-zinc plated and bracket to accomodate face mounting. Sqmt 180.54 Included 0.00 0 0
I. SUB HEAD: WINDOWS, FIRE DOORS AND GLAZED PARTITIONS 0 0
63.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 0 0
63.2 18 Second class teak wood cum 1.13 Included 0.00 0 0
64 18 Providing dash fastners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats) Nos 174.00 Included 0.00 0 0
65 PProviding and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 0 0
65.1 18 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 34.86 Included 0.00 0 0
65.2 18 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 12.96 Included 0.00 0 0
66 18 Providing and fixing 4 mm thk approved veneer on one side and 1.5 mm thk approved laminate on the other side of the exposed surfaces of the flush door shutters including finihshing the veneer with melamine polish of desired shade. The rate shall include the adhesives, labour, materials, nails, screws etc complete and nothing extra shall be paid on this account as per the directions and instructions of the E-I-C. (The rate quoted shall be for the cumulative quantity and only one side area shall be measured for payment). sqm 34.86 Included 0.00 0 0
67 18 Providing and fixing 4 mm thk approved veneer on both sides of the shutters of the flush door shutters including finihshing the same with melamine polish of desired shade. The rate shall include the adhesives, labour, materials, nails, screws etc complete and nothing extra shall be paid on this account as per the directions and instructions of the E-I-C. (The rate quoted shall be for the cumulative quantity and only one side area shall be measured for payment). sqm 12.96 Included 0.00 0 0
68 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 0 0
68.1 18 2nd class teak wood: 50x12 mm meter 50.00 Included 0.00 0 0
68.2 18 3rd class teak wood: 50 x 20 mm meter 50.00 Included 0.00 0 0
69 18 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). sqm 5.19 Included 0.00 0 0
70 18 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. Nos 4.00 Included 0.00 0 0
71 18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, including handles (600x 22mm) on both sides, lock patch fittings, etc. all complete as per direction of Engineer-incharge. Dormakaba / Godrej / Kich make or equivalent Sqm 20.25 Included 0.00 0 0
72 Providing and fixing satin finish Stainless steel tower bolts, ISI marked, colour or shade, with necessary screws etc. complete : 0 0
72.1 18 300x12 mm Nos 20.00 Included 0.00 0 0
73 18 Providing and fixing of stainless steel 304 grade of make PULL HANDLES 300 x 22mm, SS 304, Finish : Satin with necessary screws etc. complete. Dormakaba / Godrej / Kich make or equivalent Nos 40.00 Included 0.00 0 0
74 18 Provinding and fixing of Pull Handle for Door 600 MM length in Stainless Steel finish fixed on one side of the door with necessary screw etc. Nos 4.00 Included 0.00 0 0
75 18 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.: Triple strip vertical type Nos 8.00 Included 0.00 0 0
76 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete 0 0
76.1 18 Twin rubber stopper Nos 20.00 Included 0.00 0 0
77 18 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Nos 20.00 Included 0.00 0 0
78 18 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). metre 26.00 Included 0.00 0 0
79 18 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). sqm 12.05 Included 0.00 0 0
80 18 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of SUB HEAD : 9.0 WOOD AND P.V.C. WORK 206 Code Description Unit Rate No. E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. sqm 0.90 Included 0.00 0 0
81 18 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. Nos 5.00 Included 0.00 0 0
82 Automatic Sliding Door with ST Flex Frames Motorized Sliding Framed Glass Door Providing and fixing Automatic Sliding door operator, Make: DORMA ES 200 Easy 6250, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested for durability of 1 Million Cycles, tested according to the low voltage guidelines, fulfils DIN 18650 standards, for framed glass door application with DORMA ST-Flex Profiles Systems, modular design including internal cover and with 12mm toughened glass for 2 Nos sliding door panels with DORMA ST-Flex framed profile system with Interlocking Seals. Operator & Frame Finish should be in Black, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening size given below. DORMA ES200 Easy Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting. The track profile should be separate from the main profile for enabling reduction in vibration insulation, With backplate for easy Installation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, with SMPS, Class of protection IP 20. IXIO Sensor System. With Electro-mechanical locking, Bistable, Program Switch with Key. ES 200 Easy, Max Panel Weight Carrying Capacity of 2 X 100 Kgs. The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below: Pre-approved make: DORMA ES 200 Easy 6250 Automatic with ST Flex or equivalent 0 0
82.1 18 SLD (Door portion) sqm 10.08 Included 0.00 0 0
83 18 Double Leaf Aluminium Glazed Door of 12mm Toughened Glass with Alexa System-100 Frame Profile Supply & Fixing of Aluminium Glazed Door (Double Leaf) of 12mm Toughened Glass with dormakaba Alexa System-100 frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Alexa STP100 Door Profile frame with clips & seals with dormakaba Flush Hinges (8 Nos) , TGDI D type Offset Pull Handle 600mm x25mm, CTC - 600mm, D -25mm, Back to back fixing (2 Pairs), 917 Narrow stile Dead Lock package (1 Set), ITS Concealed Door closer (as per EN 1154) with Hold Open unit (2 Nos), Manual Flush bolt for Metal doors 172mm (with 300mm length rod) - 1 No, Manual Flush bolt for Metal doors 172mm (with 600mm length rod) - 1 No, Dust proof floor socket for flush bolt (1 No), Automatic door bottom RP8si seal (2 Nos). Necessary seals to be provided all around the door frames. For doors part DP100-SG Door rebate profile to be used.In case of Glass overall panel Alexa OHPDP100-SD/DG Over Panel Door profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles /Frames: dormakaba or equivalent Glass : Saint Giobain/Asahi/ Modiguard sqm 5.04 Included 0.00 0 0
84 18 Single Leaf Aluminium Glazed Door of 12mm Toughened Glass with Alexa System-100 Frame Profile. Supply & Fixing of Aluminium Glazed Door (Single Leaf) of 12mm Toughened Glass with dormakaba Alexa System-100 frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Alexa STP100 Door Profile frame with clips & seals with dormakaba Flush Hinges (4 Nos) , TGDI D type Offset Pull Handle 600mm x25mm, CTC - 600mm, D -25mm, Back to back fixing (1 Pairs), 917 Narrow stile Dead Lock package (1 Set), ITS Concealed Door closer (as per EN 1154) with Hold Open unit (1 No), Automatic door bottom RP8si seal (1 No). Necessary seals to be provided all around the door frames. For doors part DP100-SG Door rebate profile to be used.In case of Glass overall panel Alexa OHPDP100-SD/DG Over Panel Door profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles /Frames: dormakaba or equivalent Glass : Saint Giobain/Asahi/ Modiguard sqm 2.52 Included 0.00 0 0
85 Providing and fixing aluminium glazed door, windows partly fixed partly openable/ sliding /fixed/openable System AW 40.NI The system is non-Thermal Break and with a basic depth of 40mm. Pre-approved model: Alpha series by AGValfab. HARDWARE: HANDLE / HINGES MAKE : ASSA ABLOY/ PULSE EPDM MAKE : SCHUCO or equivalent 0 0
85.1 18 External wall window W1 (1500x1500) Nos 5.00 Included 0.00 0 0
85.9 18 Staff Toilet V1 (860 X 900) Nos 2.00 Included 0.00 0 0
85.10 18 Jaintor room and ladies toilet V2 (600 X 1200) Nos 4.00 Included 0.00 0 0
J. SUB HEAD: PLUMBING & SANITARY FITTINGS 0 0
86 18 Providing and fixing white vitreous china wall mounting type water closet of size 595x385x385 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 liter / 6 liter ( adjustable to 2 liter / 4 liter ) including seat cover & cistern fittings nuts , bolts and gaskets etc complete . ( Make and Model : Roca (THE GAP) RS346477460, Flush Plate - Slendra Plus Push Plate Roca - RE890195001 , Concealed Stop Cock Jaquar LYR - 38083 K , Concealed Cistern Dual Flush -Roca RE890010200. Each 14.00 Included 0.00 0 0
87 18 Providing and fixing White Table Top Ractanguler Wash Basin Size 550 x 370 mm with 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : ( Make and Model : Inspira W B soft 550 x 370 S Ins White- RS 327504000), Bottle Trap ECO - RF9066A1 Each 6.00 Included 0.00 0 0
88 18 Providing and fixing White Viterous China under counter Wash Basin Berna undercounter B 560x 420 White with 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : (Make and Model : RS 32 7871461) + Bottle Trap ECO - RF9066A1. Each 8.00 Included 0.00 0 0
89 18 RCC Counters: Providing and fixing 65 mm thick RCC (mix 1:2:4) countertops in kitchen, toilet etc. including 8 mm reinforcement in both directions @ 100mm C/C. The slab must have min bearing of 65 mm in brick masonry walls. (Additional 115 mm thick support wall shall be paid for separately). Rate to include for scaffolding, formwork, openings for sinks, basins, taps etc. chasing in brick masonry complete. sq.m. 10.00 Included 0.00 0 0
90 18 MS Framing for Vanity Counters: Providing and fixing MS frames and supports for toilet vanity as per "Vanity Counter Support Frame Designed for 100kg" as per specification provided by Saint Gobain in Detailed Specification Document. Frames shall be made of MS RHS (50 x 25 x 3.6mm), 8mm thick base plates, gusset plates 200x100x5mm all painted with red oxide primer and fixed to the GI drywall partition frame and RCC floor slab with necessary screws, bolts, fasteners etc. all complete to the satisfaction of the engineer-in-charge nos 4.00 Included 0.00 0 0
91 18 Providing and fixing Single Lever Wash Basin Mixer Automatic Tap cum Auto Soap Dispenser 2 in 1 with thermostat mixer valve cutting and making good the walls wherever require : ( Make and Model : Euronics KSDT6 & Euronics HCT02 ) Each 14.00 Included 0.00 0 0
92 18 Providing and fixing health faucet CP flexible hose 1000 mm nozzles and swivel hook with CP brass wall flange and CP holder including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : Roca RF9060A1) Each 14.00 Included 0.00 0 0
93 18 Providing and fixing 15 mm dia C.P. brass angle valve for health faucet , wash basin mixer and geyser points with CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : RF525164500 ) Each 64.00 Included 0.00 0 0
94 18 Providing and fixing Toilet Paper Holder CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : ROCA RA816713001) Each 14.00 Included 0.00 0 0
95 18 Providing & Fixing Stainless Steel type 304 towel ring 18-8 with C.P. brass round wall flanges & CP brass screws complete in all respect as per direction of engineer - in - charge . ( Make and Model : ROCA RA816070172) Each 6.00 Included 0.00 0 0
96 18 Providing and fixing of fully automatic "NO TOUCH" hand drier Stainless Steel Body suitable to operate on 220 volts, single phase 50 hz, A.C. power supply and directly plugged to power point complete. (Make and Model : Euronics PLUTO PHD 501) Each 4.00 Included 0.00 0 0
97 18 Providing & Fixing Stainless Steel type 304 twin coat hook 18-8 with C.P. brass round wall flanges & CP brass screws complete in all respect as per direction of engineer - in - charge . (Make and Model : Euronics EC 02) Each 12.00 Included 0.00 0 0
98 18 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 425 x797 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. ( Make and Model : ROCA Euret urinal sensor (BAT) Each 6.00 Included 0.00 0 0
99 Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug . ( Make and Model - Jaquar ELENA Vertical / Horizontal) 0 0
99.1 18 6 Litre Capacity Each 8.00 Included 0.00 0 0
99.2 18 15 Litre Capacity Each 2.00 Included 0.00 0 0
100 18 Providing & Fixing surface mounted hydration station 960(H) x 413(W) x 473(D) made of stainless steel having storage capacity of 60 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . Hydration station OASIS VERSA FILLER-P8SBFY, RO- Oasis 50LPH RO SYSTEM, Pressure tank - Oasis HPT TANK 60LTR with accessories Each 2.00 Included 0.00 0 0
101 18 Providing and fixing Stainless Steel Sanitary Napkin Hygiene Panel 3 in 1 For Feminine washroom CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . (Make and Model : ESN03S) Each 2.00 Included 0.00 0 0
102 18 Providing and fixing Stainless steel paper dispenser( Capacity 450 - 500 Paper Towel ) wherever required complete in all respect as per direction of engineer in charge. (Make and Model : Euronics EP 23 ) Each 10.00 Included 0.00 0 0
103 18 Providing and fixing 6mm thick clear mirror with bevelled edge mounted on 12mm thick plywood with ARALDITE. Rate to include for glue, anchor fasteners to fix ply to wall etc. all inclusive sq.m. 14.90 Included 0.00 0 0
K. SOIL , WASTE VENT AND RAIN WATER PIPE 0 0
104 Providing and fixing uPVC 6kg/cm2 Soil , Waste & RWP pipes (IS: 13592 Class B) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces as per IS : 14735 jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good wherever required. 0 0
104.1 18 110 mm OD Metre 104.30 Included 0.00 0 0
104.2 18 160 mm OD Metre 60.00 Included 0.00 0 0
105 Providing and fixing uPVC waste pipes 6 Kg / cm2 for WB , SINK , URINAL , FD (IS: 4985 Class III ) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces as per IS : 4985 jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good wherever required. 0 0
105.1 18 65 mm OD Metre 27.20 Included 0.00 0 0
106 Providing & fixing in position upvc P"or S" trap of self cleaning design of following sizes for the embedded areas Making proper connection with chemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 0 0
106.1 18 110 mm inlet and 110 mm outlet Each 14.00 Included 0.00 0 0
107 Providing & fixing in position upvc floor drain including cost of cutting and making good the walls and floors wherever required. 0 0
107.1 18 110 mm inlet and 63 mm outlet Each 33.00 Included 0.00 0 0
108 18 Providing and fixing Chrome Polished Floor Drain (SS Jali) Anti Order, Blockage and Overflow Seal floor drain cover in chrome finish. The installation shall be done to the satisfaction / approval of Engineer-in-charge. Each 32.00 Included 0.00 0 0
L. INTERNAL WATER SUPPLY 0 0
109 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.: Concealed work, including cutting chases and making good the walls etc. 0 0
109.1 18 15 mm nominal outer dia Pipes Metre 14.06 Included 0.00 0 0
109.2 18 20 mm nominal outer dia Pipes Metre 112.85 Included 0.00 0 0
109.3 18 25 mm nominal outer dia Pipes Metre 100.00 Included 0.00 0 0
109.4 18 32 mm nominal outer dia Pipes Metre 100.00 Included 0.00 0 0
110 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 0 0
110.1 18 40 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
110.2 18 50 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
111 Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 0 0
111.1 18 25 mm dia nominal bore Each 30.00 Included 0.00 0 0
111.2 18 32 mm dia nominal bore Each 2.00 Included 0.00 0 0
111.3 18 40 mm dia nominal bore Each 1.00 Included 0.00 0 0
111.4 18 50 mm dia nominal bore Each 1.00 Included 0.00 0 0
M. External Finishing 0 0
112 18 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) METER 300.00 Included 0.00 0 0
113 18 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. sqm 3000.00 Included 0.00 0 0
ELECTRICAL WORKS ELECTRICAL WORKS 0 0
A. SWITCH CONTROL LIGHT POINTS 0 0
1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(For Concealed Wiring) 0 0
1.1 18 Group A Points 61 Included 0.00 0 0
1.2 18 Group B Points 100 Included 0.00 0 0
1.3 18 Group C Points 50 Included 0.00 0 0
2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 0 0
2.1 18 Group A Points 100 Included 0.00 0 0
2.2 18 Group B Points 20 Included 0.00 0 0
2.3 18 Group C Points 15 Included 0.00 0 0
B. MCB CONTROL LIGHT POINTS 0 0
3 18 Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr. 950 Included 0.00 0 0
4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 0 0
4.1 18 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Mtrs 60 Included 0.00 0 0
4.2 18 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Mtrs 1650 Included 0.00 0 0
4.3 18 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Mtrs 200 Included 0.00 0 0
4.4 18 4x 10 sqmm+ 2x 6 sqmm earth wire Mtrs 250 Included 0.00 0 0
4.5 18 4x 16 sqmm+ 2x 6 sqmm earth wire Mtrs 175 Included 0.00 0 0
5 Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required. 0 0
5.1 18 25 mm dia. Mtrs. 450 Included 0.00 0 0
5.2 18 32 mm dia. Mtrs. 100 Included 0.00 0 0
6 Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 0 0
6.1 18 5/6 amps switch Each 261 Included 0.00 0 0
6.2 18 3 pin 5/6 amp socket outlet Each 10 Included 0.00 0 0
7 18 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Each 20 Included 0.00 0 0
8 Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 0 0
8.1 18 1or 2 module (75mmx 75mm) Each 10 Included 0.00 0 0
8.2 18 3 module (100mmx 75mm) Each 10 Included 0.00 0 0
8.3 18 4 module (125mmx 75mm) Each 30 Included 0.00 0 0
8.4 18 6 module (200mmx 75mm) Each 10 Included 0.00 0 0
8.5 18 8 module (200mmx 125mm) Each 5 Included 0.00 0 0
9 18 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. Each 160 Included 0.00 0 0
10 18 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. Each 140 Included 0.00 0 0
11 18 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required. Each 65 Included 0.00 0 0
C. SUB HEAD: DISTRIBUTION BOARD 0 0
12 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 0 0
12.1 18 6 way (4+18),Double door Each 6 Included 0.00 0 0
12.2 18 8 way (4+24),Double door Each 6 Included 0.00 0 0
13 Supplying & fixing 5 amps to 32 amps rating 240/415 volts C curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0 0
13.1 18 Single Pole Each 180 Included 0.00 0 0
14 18 Supply & fixing of single pole blanking plate in the existing MCB DB complete etc. as required Each 10 Included 0.00 0 0
15 Supplying and fixing of following rating four pole 415 V isolator in the existing MCB DB complete with connections ,testing and commissioning etc as required. 0 0
15.1 18 40 amps Each 6 Included 0.00 0 0
15.2 18 63 amps Each 6 Included 0.00 0 0
16 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0 0
16.1 18 40 Amps Each 18 Included 0.00 0 0
16.2 18 63 Amps Each 18 Included 0.00 0 0
D. SUB HEAD: CABLE TRAYS & RACEWAYS 0 0
17 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.. 0 0
17.1 18 150 mm width X 50 mm depth X 1.6 mm thickness Mtrs. 30 Included 0.00 0 0
17.2 18 450 mm width X 50 mm depth X 2.0 mm thickness Mtrs. 50 Included 0.00 0 0
18 S/ F powder coated of approved shade MS Cable Tray Tee's 0 0
Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 0 0
18.1 18 300 mm width X 50 mm depth X 1.6 mm thickness Nos. 3 Included 0.00 0 0
Fabricating supplying to site of installation, in floor including chase cutting of floor,leveling, refilling and making good the same from 1.6 mm thick and 2 mm thick cover pregalvanised MS CRCA sheet, totally enclosed, height 40 mm . The two lengths of raceways shall be fitted with Collars , 50 mm wide, 3 mm thick , press fit type. The raceways shall be clamped to the floor slab with GI clamps , 3mm thick and shall be screwed to the floor slab. The joint between raceway and junction box will be made with GI flexible strip( 3 nos), 3 mm thick, 4 inches long ,15 mm wide which will be nut bolted to the Junction box complete as required etc. 0 0
19.1 18 100 mm x 40 mm x 2 mm thick RM 10 Included 0.00 0 0
19.2 18 150 mm x 40 mm x 2 mm thick RM 135 Included 0.00 0 0
19.3 18 200 mm x 40 mm x 2 mm thick RM 24 Included 0.00 0 0
19.4 18 300 mm x 40 mm x 2 mm thick RM 48 Included 0.00 0 0
20 Junction box 0 0
Fabricating supplying to site of installation, Junction boxes for floor raceways made from 2 mm thick , with 2.5 mm thick G.I. cover including providing neoprene gaskets between the cover and the junction box, cadmium plated flat/round head screws, height as per site condition,totally enclosed. Proper cutouts shall be made in the side walls for raceway entry wherever required. The junction box shall be all side walls should be welded expect top cover and all side walls shall have suitable size of rectangular knock out holes for taking raceways / conduits as required and not a complete cut out. The top cover should be sealed with M Seal to make it dust and water proof complete as required etc. 0 0
20.1 18 200 mm x 200 mmx 40 mm (height) Nos. 35 Included 0.00 0 0
20.2 18 250 mm x 250 mmx 40 mm (height) Nos. 9 Included 0.00 0 0
20.3 18 350 mm x 500 mmx 40 mm (height) Nos. 3 Included 0.00 0 0
E. SUB HEAD : LIGHT FIXTURES 0 0
21 18 Supply, Installation, Testing and Commissioning of Philips Essential full glow 2x2 Panel 30w - 40w RC360B LED36S. Philips or Equivalent make Nos. 141 Included 0.00 0 0
22 18 Supply and Installation of Profile Recessed luminaire Slash with HE-High Efficiency LED(Light Emitting Diode) system power: 14W, luminous flux of luminaire 1400lm, colour temperature of 4000K, neutral white,CRI>80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, direct light emission,luminaire profile in anodised aluminium, pre-wired batten luminaire,opal APD (Added Performance Diffuser) diffuser for a homogenous light distribution, ZHLS(ZERO HALOGEN LOW SMOKE) internal wiring, integral electronic control gear, Protection class I, IP40 L = 1178 mm, EL = 1190 B = 48 mm, EB = 61mm, H = 70 mm LED0571RA1411780014J7 Mtr 26.4 Included 0.00 0 0
23 18 Supply, Installation, Testing and Commissioning of 15W-20w Recess Mounted LED circular Downlighter (Cat no- Philips Lighting DN296B LED15S-6500 PSU WH) Philips or Equivalent make Nos. 143 Included 0.00 0 0
24 18 Supply, Installation, Testing and Commissioning of 5W-3w Recess Mounted LED circular Downlighter (Cat no- Philips Lighting DN296B LED12S-6500 PSU WH) Philips or Equivalent make Nos. 15 Included 0.00 0 0
25 18 Supply, Installation, Testing and Commissioning of 5W/mtr. Cove light (LED STRIP LIGHTS-(Cat no- Philips Lighting LED Strip SKYCove 5M WW with driver) Philips or Equivalent make 25 Nos Mtrs 75 Included 0.00 0 0
26 18 Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. Nos. 14 Included 0.00 0 0
F. High End Electrical 0 0
27 18 Supplying and fixing pop up box 8 (2x4) Module Legrand 054023 Brushed Stailness Steel Finish plate with Box for installation on Table Top. Accessories / fittings to be paid for seperately. Each 12 Included 0.00 0 0
28 18 Design, manufacturing and supplying and commissioning of LT Panel (415V) cubicle type Out Door Type as per technical specification and comprising of the following (Refer schematic diagram of LT panel) The panel shall be FRONT operated, suitable for bus duct entry for incomings & outgoing cable entry from the bottom. The fault with standing capacity shall be 50 KA. Continuous earth bus shall be provided with the LT panel board complete as required with following: (A) INCOMER 1 No 250 Amp FP MCCB, 25 kA breaking capacity with Thermal release and rotatry handle. (B) METERING & INDICATION (i) 1 set of R,Y,B phase indicating lamps (ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB (iii) 1 No. (0-300 A) Ammeter with ASS with 3 nos. 250/5A CT's (C) BUS-BAR 1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves (D) OUTGOINGS (i) 4 Nos. 40 Amp FP MCB, 10 kA breaking capacity (ii) 8 Nos. 63 Amp FP MCB, 10 kA breaking capacity Complete with copper wire connection from busbar to out going connector block as rerquired . (iii) 2 Nos 125 Amp TPN MCCB, 25 KA breaking capcity . Set 1 Included 0.00 0 0
29 18 Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications. 3½ x 70 sq. mm ( Assume for Incomming cable for HVAC Panel ) RM 100 Included 0.00 0 0
30 18 Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications. 3½ x 150 sq. mm ( Assume for Incomming cable for HVAC Panel ) RM 200 Included 0.00 0 0
31 18 Laying and fixing of one no PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on Cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Mtrs. 100 Included 0.00 0 0
32 18 Laying and fixing of one no PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on Cable tray as required. Above 120 sq. mm and upto 185 sq. mm (clamped with 25x3mm MS flat clamp) Mtrs. 200 Included 0.00 0 0
33 18 Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required. 3½ x 70 sq. mm Set 4 Included 0.00 0 0
34 18 Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required. 3½ x 150 sq. mm Set 6 Included 0.00 0 0
35 18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. RM 100 Included 0.00 0 0
G. SUB HEAD: STRUCTURED CABLING SYSTEM PASSIVE 0 0
36 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 0 0
36.1 18 1 run of cable Mtr 1000 Included 0.00 0 0
36.2 18 2 run of cable Mtr 3000 Included 0.00 0 0
36.3 18 3 run of cable Mtr 5000 Included 0.00 0 0
37 18 Supply , Installtion , Testing and Comissioning of CAT6 information outlet (I/O) for Camera at user end. Nos. 270 Included 0.00 0 0
38 18 Supply, Installation, Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end. Nos. 6 Included 0.00 0 0
39 18 Supply, Installation, Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Nos. 270 Included 0.00 0 0
40 18 Supply, Installation, Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity. Nos. 270 Included 0.00 0 0
41 18 Supply, Installation, Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Nos. 270 Included 0.00 0 0
42 18 Supply, Installation, Testing and Commissioning of 42 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Nos. 3 Included 0.00 0 0
43 18 Supply & fixing of single HDMI port. Nos. 15 Included 0.00 0 0
44 18 Supply & laying of HDMI Cable 3 mtr. Nos. 15 Included 0.00 0 0
45 18 Supply & laying of HDMI Cable 20 mtr. Nos. 15 Included 0.00 0 0
H. SUB HEAD: MULTI ANTENNA AV SYSTEM 0 0
46 Supply and fixing following signal outlets with grid plate in 2 mm thick GI box complete including cutting, chases, fixing of GI boxes and making good. (Cover plate shall match the colour, size and make of wiring accessories to be used in the project). 0 0
46.1 18 TV Signals outlet Nos 10.00 Included 0.00 0 0
47 18 Supply, laying, connecting and commissioning of RG-11 co-axial cable of MATV as per specification in existing MS conduit RM 150.00 Included 0.00 0 0
48 18 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. RM 675.00 Included 0.00 0 0
49 Supply Installation Testing & Commissioning of Splitters as required. 0 0
49.1 18 2-Way Splitter Nos 5.00 Included 0.00 0 0
49.2 18 4-Way Splitter Nos 2.00 Included 0.00 0 0
50 Supply Installation Testing & Commissioning of Tap-off Box as required. 0 0
50.1 18 2-Way Tap-off Box Nos 5.00 Included 0.00 0 0
50.2 18 4-Way Tap-off Box Nos 5.00 Included 0.00 0 0
51 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 0 0
51.1 18 25 mm dia. RM 150.00 Included 0.00 0 0
I. Variable Refrigerant Flow Air-conditioning System 0 0
52 Outdoor Units 0 0
52.1 18 Supply ,Installation,Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s) , minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant,vibration isolators, with suitable foundation etc.complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%, 3Phase, 50HzAC power supply. The unit shall be filled with first charge of the refrigerant andready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . Per HP 116 Included 0.00 0 0
53 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0 0
53.4 18 1.6 TR Each 4 Included 0.00 0 0
53.5 18 2.0 TR Each 18 Included 0.00 0 0
53.8 18 3.2 TR Each 2 Included 0.00 0 0
54 18 4.0 TR Each 10 Included 0.00 0 0
54 Copper Refrigerant Piping 0 0
541 Supply,Installation,testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF or Non VRV/VRF system, complete with fittings,with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications 0 0
54.2 NOTE:-1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2)Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe. 0 0
54.3 18 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 65 Included 0.00 0 0
54.4 18 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 95 Included 0.00 0 0
54.5 18 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 110 Included 0.00 0 0
54.6 18 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 95 Included 0.00 0 0
54.7 18 19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 65 Included 0.00 0 0
54.8 18 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 70 Included 0.00 0 0
54.9 18 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 55 Included 0.00 0 0
54.1 18 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 75 Included 0.00 0 0
54.11 18 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 50 Included 0.00 0 0
54.12 18 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 60 Included 0.00 0 0
54.13 18 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 25 Included 0.00 0 0
54.14 18 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 20 Included 0.00 0 0
55 DRAIN PIPING 0 0
55.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVCsolventcement and testing of joints complete as per direction of Engineer in Charge. 0 0
55.2 18 25 MM Nominal Outerdia Pipes M 90 Included 0.00 0 0
55.3 18 32 MM Nominal Outerdia Pipes M 80 Included 0.00 0 0
56 Insulation material for Drain Pipe 0 0
56.1 Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suiatable adhesive, as per specifications and as required complete in all respect. 0 0
56.2 18 19 mm Sqm 180 Included 0.00 0 0
57 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 0 0
57.1 18 100 mm width X 50 mm depth X 1.6 mm thickness M 70 Included 0.00 0 0
57.2 18 150 mm width X 50 mm depth X 1.6 mm thickness M 50 Included 0.00 0 0
57.3 18 200 mm width X 50 mm depth X 1.6 mm thickness M 30 Included 0.00 0 0
57.4 18 300 mm width X 50 mm depth X 1.6 mm thickness M 30 Included 0.00 0 0
57.5 18 450 mm width X 50 mm depth X 1.6 mm thickness M 20 Included 0.00 0 0
58 18 Providing and fixing G.I tape 20mm x 3 mm thick onparapet or surface of wall for lightning conductor complete as required. (For horizontal run) M 540 Included 0.00 0 0
59 Factory fabrication GSS Duct 0 0
59.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 0 0
59.2 18 Thickness 0.63 mm sheet (24 Gauge) Sqm 8 Included 0.00 0 0
59.3 18 Thickness 0.80 mm sheet (22 Gauge) Sqm 12 Included 0.00 0 0
60 16 G GI VCD 0 0
60.1 18 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws inkages, flanges etc, as per specifications. Sqm 2 Included 0.00 0 0
61 Supply air Grill 0 0
61.1 18 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. Sqm 12 Included 0.00 0 0
62 Duct Inside Acoustic lining 0 0
62.2 18 Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. Sqm 4 Included 0.00 0 0
63 Supply,installation,testing and commissining of direct driven Tube axial flow fans suitable for installing in any position in Horizontal or vertical with adjustable pitch blade, MS / high duty GSS long Casing , cast aluminium alloy impeller complete with TEFC Sq. Cage Induction type IE 2 motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 Pole, three phase A.C supply of class "F" insulation motor's winding with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep with 25 mm slack at Outlet etc.. 0 0
63.1 For Make Up air in Common Corridor ( In Case of Fire ) 0 0
63.2 18 5000 CFM / 15 mm St. Press. Nos 2 Included 0.00 0 0
63.3 18 4000 CFM / 15 mm St. Press. Nos 2 Included 0.00 0 0
64 Supply, installation, testing and commissioning of Inline Fan with centrifugal blower and motor encased in sheet metal casing, as per specifications. The motor shall be suitable for 220 ± 6% V, 50 Hz AC supply. The price shall include fan speed regulator and cowl with bird screen and electrical wiring from socket to fan considering 3 m distance between socket and fan. 0 0
64.1 18 600 CFM / 15 mm St. Press. - For Toilet Exhaust Nos 10 Included 0.00 0 0
65 18 Supply,installation, testing and commissionig of refrigerant Copper Y-joints. Set 60 Included 0.00 0 0
66 18 Refrigerant R-410A to top up the system if required. Kg 50 Included 0.00 0 0
67 HVAC Panel - For ODU at Terrace 0 0
67.1 Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabrication 0 0
67.2 INCOMING : 0 0
67.3 One No. 400 amps, 35 ka, 4-pole MCCB complete with adustable overload circuit protection. 0 0
67.4 96 x 96 mm square MFM digital type 1 Set 0 0
67.5 Phase indicating lamps with control SP MCB. 0 0
67.6 Aluminum bus bar sleeve type rated at 800 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacity 0 0
67.7 Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for smoke extraction axial fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. 0 0
67.8 OUTGOING : 0 0
67.9 4 Nos 40 amps, 25 k, TPN MCCB with single phase /overload circuit protection. 0 0
67.1 4 Nos 63 amps, 25 k, TPN MCCB with single phase /overload circuit protection. 0 0
67.11 18 2 Nos 100 amps, 25 k, TPN MCCB with single phase /overload circuit protection. Set 1 Included 0.00 0 0
68 HVAC PANEL-2, Emergency panel For Pressurization system & Outgoing feeder for Starter panel of Fresh Air & Smoke Exhaust fans at each floor 0 0
68.1 Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabrication 0 0
68.2 Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for smoke extraction axial fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. 0 0
68.3 INCOMING : 0 0
68.4 One No. 125 amps, 25 ka, 4-pole MCCB complete with adustable overload circuit protection. 0 0
68.5 0-500 Volts 96 x 96 mm square voltmeter digital type with selector switch 1 Set 0 0
68.6 0-200 amps ammeter digital type with 200/5 amps CT's and selector switch 1 Set 0 0
68.7 Phase indicating lamps with control SP MCB. 0 0
68.8 Aluminum bus bar sleeve type rated at 250 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacity 0 0
68.9 OUTGOING : 0 0
68.1 4 Nos. 25 Amps MCB DOL Starter for Supply Fan's Motor, over load relay with built in single phasing protection. The compartment shall contain an indicating lamp with MCB for ‘ON’ status. 0 0
68.11 4 Nos. 16 Amps MCB DOL Starter for Supply Fan's Motor, over load relay with built in single phasing protection. The compartment shall contain an indicating lamp with MCB for ‘ON’ status. 0 0
68.12 18 6 Nos 32 amps, 25 k, TPN MCCB with single phase /overload circuit protection. Set 2 Included 0.00 0 0
69 Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabrication 0 0
69.1 Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for smoke extraction axial fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. 0 0
69.2 INCOMING : 0 0
69.3 One No. 32 amps, 25 ka, 4-pole MCCB complete with adustable overload circuit protection. 0 0
69.4 0-500 Volts 96 x 96 mm square voltmeter digital type with selector switch 1 Set 0 0
69.5 0-40 amps ammeter digital type with 32/5 amps CT's and selector switch 1 Set 0 0
69.6 Phase indicating lamps with control SP MCB. 0 0
69.7 Aluminum bus bar sleeve type rated at 63 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacity 0 0
69.8 OUTGOING : 0 0
69.9 18 2 Nos. 16 Amps MCB DOL Starter for Fan's Motor, over load relay with built in single phasing protection. The compartment shall contain an indicating lamp with MCB for ‘ON’ status. Set 4 Included 0.00 0 0
70 POWER CABLING 0 0
70.1 Supply,of following 1100 volt grade PVC insulated copper conductor armoured cable on cable trays, existing trenches, burried cables including the cost of providing identification tags,route markers etc. complete as per specification and as per site requirements. 0 0
70.2 For Outdoor unit 0 0
70.3 18 4C x 25 Sq. mm RMT 70 Included 0.00 0 0
70.4 18 4C x 16 Sq. mm RMT 50 Included 0.00 0 0
70.5 18 4C x 10 Sq. mm RMT 60 Included 0.00 0 0
70.6 18 4C x 6 Sq. mm RMT 35 Included 0.00 0 0
70.7 18 4C x 4 Sq. mm RMT 150 Included 0.00 0 0
71 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 0 0
71.1 18 Upto 35 sq. mm RMT 1265 Included 0.00 0 0
72 Supply,laying,testing and commissioning of following copper PVC insulated, sheathed unarmoured cable for indoor unit/inline fans.Cabling between 15 amp Switch socket outlet and each of the indoor units shall also be included in this cost. 0 0
72.1 18 3C x 2.5 Sq. mm RMT 300 Included 0.00 0 0
73 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 0 0
73.1 18 4C x 25 Sq. mm Nos 15 Included 0.00 0 0
73.2 18 4C x 16 Sq. mm Nos 20 Included 0.00 0 0
73.3 18 4C x 10 Sq. mm Nos 14 Included 0.00 0 0
73.4 18 4C x 6 Sq. mm Nos 2 Included 0.00 0 0
73.5 18 4C x 4 Sq. mm Nos 14 Included 0.00 0 0
71 CONTROL CABLING 0 0
71.1 Supply & Laying ,testing and commissioning of control cum transmission wiring of Copper conductor shielded cable for looping between indoor & outdoor VRF system & to main Central remote controller system 0 0
71.2 18 3 C X 1.5 Sq. mm RMT 600 Included 0.00 0 0
J. SUB HEAD: CCTV SYSTEM 0 0
72 18 Supply, Installation, testing commisioning of Standalone IP CCTV System comprising of following: Infrared Dome Camera, 1/3" Interline Transfer CCD Sensor, Resolution of 600 TV Lines, 3.6 mm Lens, Automatically activates LED: below 10 lux, Radiant Distance Up to 20M, Power Input voltage - 12V DC Nos 4 Included 0.00 0 0
73 18 Supply, Installation, testing commisioning of Standalone IP CCTV System comprising of following: Bullet Camera Max 25 fps @ 5MP (16:9 Video Output) 120 dB true WDR, 3DNR, 24/7 colour imaging 60 m illumination distance CVI/CVBS/AHD/TVI switchable Built in Mic AutoFocus, 2.7 mm - 13.5mm Motorized Lense, Power Consumtion 11.88 w, 12 V DC. Nos 6 Included 0.00 0 0
74 18 Providing and laying flexible category 6 (CAT 6) cable for video transmission through the conduit (Including cost of conduit and its proper installation on ceiling/ wall etc.) Make D Link Mtr 650 Included 0.00 0 0
75 18 Medium Grade - 25 mm FRPVC Conduit with fitting ISI Marked with GI saddle & spacers at every 0.3 Mtr and Flexible conduits for all drops above false ceiling. Mtr 700 Included 0.00 0 0
76 18 20" colour, Flat Screen Type Professional CCTV Surveillance HD monitor 100-230 Vac 50 Hz.24x7 with wall mounted swivel stand Nos 1 Included 0.00 0 0
77 18 40" colour, Flat Screen Type Professional CCTV Surveiilance HD monitor of reputed make 100-230 VAC 50 Hz. 24x7 with wall mounted swivel stand Nos 1 Included 0.00 0 0
78 18 Redundant Power Supply with Input 230 VAC +/- 2V, load regulation & line regulation less than 0.1%, Electronic protection against overload & short circuit, output ripples less than 1 milli volt RMS5 Amps output Nos 1 Included 0.00 0 0
79 18 Network video Recorder with Monitoring, Viewing & Recording Software Embedded linux/Windows, MPEG4 compression LAN/TCP/IP, Networked Pentaplex operation Schedule/Motion/Alarm sensor recordings/ continuous server to server configuration Upto 8 Alarm input & 4 Relay output Alarm notification Via email Smart search, Post & pre alarm recording Water marking, PTZ control, password protection Minimum 1000 GB HDD, expandable with builtin DVD Writer (minimum 30 days storage) Upto 8 simultaneous views from different DVRS on same LAN on single screen Network bandwidth trottling from 128 Kbps to 19 Mbps 8 Channel - Display 200 fps, Recording 100 fps Nos 1 Included 0.00 0 0
80 18 Providing and laying flexible category HDMI Cable (including cost of conduit and its proper installation on ceiling/ wall etc.) Mtr 150 Included 0.00 0 0
K. SPRINKLER SYSTEMS 0 0
81 PIPES & ACCESSORIES 0 0
Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 0 0
81.1 18 25 mm dia M 300 Included 0.00 0 0
81.2 18 32 mm dia M 140 Included 0.00 0 0
81.3 18 40 mm dia M 50 Included 0.00 0 0
81.4 18 50 mm dia M 40 Included 0.00 0 0
81.5 18 65 mm dia M 55 Included 0.00 0 0
81.6 18 80 mm dia M 110 Included 0.00 0 0
81.7 18 100 mm dia M 30 Included 0.00 0 0
81.8 18 150 mm dia M 6 Included 0.00 0 0
82 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required : 0 0
82.1 18 Single headed Gunmetal Set 2 Included 0.00 0 0
83 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0 0
83.1 18 80 mm dia Set 2 Included 0.00 0 0
84 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 0 0
84.1 18 Gun Metal Set 2 Included 0.00 0 0
85 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 0 0
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 0 0
20 mm nominal internal dia gun metal globe valve & nozzle. 0 0
Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 0 0
85.1 18 30 m Set 2 Included 0.00 0 0
86 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 0 0
86.1 18 Gun metal Nos. 2 Included 0.00 0 0
87 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 0 0
87.1 18 Pendent Sprinkler Each 151 Included 0.00 0 0
87.2 18 Upright Sprinkler Each 95 Included 0.00 0 0
87.3 18 Horizontal side wall sprinkler Each 6 Included 0.00 0 0
88 18 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Each 2 Included 0.00 0 0
89 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 0 0
89.1 18 100mm dia Each 2 Included 0.00 0 0
90 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 0 0
90.1 18 80mm dia Set 2 Included 0.00 0 0
91 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 0 0
91.1 18 1000mm Set 50 Included 0.00 0 0
91.2 18 1200mm Set 40 Included 0.00 0 0
92 18 Providing and fixing of Fire Hose Cabinet size not less than 2.1 x 1.2 x 0.90 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including necessary locking arrangement and painting in PO red colour suitable to accommodate, internal hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man's axe. It shall be fixed inside the FHC Cabinet Complete as required . Each 2.00 Included 0.00 0 0
93 18 Providing and fixing standard firemans axe with heavy rubber handle. Each 2 Included 0.00 0 0
94 18 Providing and fixing Fire Extinguishers (CO2 type powder ) 4.5 Kg Capacity complete with all accessories as per manufacturers specifications. Each 15 Included 0.00 0 0
95 18 Providing and fixing Fire Extinguishers (A, B, C type powder ) 6 Kg Capacity complete with all accessories as per manufacturers specifications. Each 12 Included 0.00 0 0
L. FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) 0 0
INTELLIGENT FIRE ALARM SYSTEM 0 0
96 18 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. Each 2 Included 0.00 0 0
97 18 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Each 100 Included 0.00 0 0
Below the ceiling 0 0
98 18 Supplying, installation, testing & commissioning of Addressable 2 wire optical Multisensor (smoke cum heat) detector with built-in short circuit isolator, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity that can handle upto 5000 Lux, Discreet design for incorporation into any décor, Common mounting base, Drift compensation, detector sensitivity of 2.55+/- 0.33%/ft, Chamber monitoring by panel, option to connect remote indicator. Designed to meet UL268, 7th Edition. Nos. 100 Included 0.00 0 0
Above the ceiling 0 0
99 18 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Each 40 Included 0.00 0 0
100 18 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. Each 4 Included 0.00 0 0
101 18 Supplying, installation, testing & commissioning of fault isolator complete with base as required. Each 20 Included 0.00 0 0
102 18 Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. Each 12 Included 0.00 0 0
103 18 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Each 4 Included 0.00 0 0
104 18 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. Each 2 Included 0.00 0 0
105 18 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Each 2 Included 0.00 0 0
106 18 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. Each 1 Included 0.00 0 0
107 18 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Each 2 Included 0.00 0 0
PUBLIC ADDRESS SYSTEM 0 0
108 18 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. Each 2 Included 0.00 0 0
109 18 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. Each 18 Included 0.00 0 0
110 18 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. Each 4 Included 0.00 0 0
111 18 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. Each 1 Included 0.00 0 0
112 18 Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. Each 2 Included 0.00 0 0
CABLING & WIRING 0 0
113 18 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. Metre 350 Included 0.00 0 0
114 18 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. Metre 350 Included 0.00 0 0
115 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 0 0
115.1 18 speaker cable Two pair, 2-core, 1.5 sqmm Metre 180 Included 0.00 0 0
116 18 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. Metre 45 Included 0.00 0 0
117 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 0 0
117.1 18 20 mm Metre 190 Included 0.00 0 0
117.2 18 25 mm Metre 70 Included 0.00 0 0
117.3 18 32 mm Metre 50 Included 0.00 0 0
118 18 Providing and fixing of solar panel with solar inverter including distribution boxes having electrical equipments on roof/terrace on Galvanised steel structure as design KW 10.8 Included 0.00 0 0
Total Supply & Installation Charges 0.00 0
Total GST as confirmed by Bidder 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 3
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 4
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Training Charges for Training to be imparted
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Training Charges excluding GST Total Training Charges excluding GST Total GST as confirmed by Bidder
Revaluation of J column Tax Calculation
NOT APPLICABLE Revaluation of J column Tax Calculation
Included 0.00 0 0
Total Training Charges 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 4b
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Maintenance Charges during & after Defect Laibility Period
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Maintenance Charges excluding GST Total Maintenance Charges excluding GST Total GST as confirmed by Bidder
0 Revaluation of P column Tax Calculation
A. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
B. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
Total Maintenance Charges during and after Defect Liabilty Period 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 5
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON GOODS Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST on Civil & Electrical works (Supply Installation Services) (Schedule-3) 0.00 #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 5
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES 0.00
Total GST on Installation Services (Schedule-3), Training to be imparted in India (Schedule-4a) and Maintenance Charges during and after Defect Liabilty Period (Schedule-4b)
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 6
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Civil & Electrical works (Supply cum Installation Charges)
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 6 After Discount
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Civil & Electrical works (Supply cum Installation Charges)
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule 7
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
SL. NO. PR No Line Item No Code HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total GST as confirmed by Bidder Revaluation of M column Tax Calculation Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
1 Included 0.00 0 0.00
2 Included 0.00 0 0.00
TOTAL TYPE TEST CHARGES 0.00
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
Bidder’s Name and Address (Sole Bidder) :
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-3 In Rs. 0.00 0.0000000000%
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-3 In Percent (%) 0.00 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : Ex-Works Price 0.0000000000%
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance 0.0000000000%
Schedule-3 : Civil & Electrical works ( S&I Charges) In Rs. 0.00 0.0000000000% Schedule-3 : Erection Charges 0.0000000000%
Schedule-4a : Training Charges In Rs. 0.00 0.0000000000% Schedule-4a : Training Charges 0.0000000000%
Schedule-4b : Maintenance Charges during and after DLP In Rs. 0.00 0.0000000000% Schedule-4b : Maintenance Charges 0.0000000000%
Schedule-7 : Type Test Charges In Rs. 0.00 0.0000000000% Schedule-7 : Type Test Charges 0.0000000000%
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-3 : Civil & Electrical works (S&I Charges) In Percent (%) 0.00 0.00%
Schedule-4a : Training Charges In Percent (%) 0.00 0.00%
Schedule-4b : Maintenance Charges during and after DLP In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00 0.00%
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Civil & Electrical works (S&I Charges). 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 4b Maintenance Charges during & after Defect Laibility Period.
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 1
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY 0 0.00
B) CENTRAL SALES TAX 0 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty % as Excise Duty
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. Statement of Quoted / Corrected Prices Page
Spec. No. Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0 Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. 0 #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
: Attachments : General guidelines for filling up the Attachments Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 5(A), 6, 9, 10, 11, 12, 13, 15, 16, 18. 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 14 Integrity Pact: To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14.
6 Attachment 18 Safety Pact: To be submitted as per ITB Clause No. 9.3(s) and as per remarks in the Attach 18.
7 Attachment 20: Declaration of Key Managerial Person and Power of Attorney holder: Format is annexed Seperetely herewith this Volume
8 Attachment 21: Affidavit (submission of Hard Copy in ‘Original’) signed and stamped with company seal for correctness of all the information/details/data/ documentary evidences
9 Attachment 22: Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1: Format is annexed Seperetely herewith this Volume
10 Attachment 23: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1: Format is annexed Seperetely herewith this Volume
11 Attachment 24: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order, if applicable: Format is annexed Seperetely herewith this Volume
11 Attachment 25: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1: Format is annexed Seperetely herewith this Volume
12 Attachment-25: Bid Securing Declaration to be submitted by the Bidder.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder SOLE BIDDER
Name of Sole Bidder
Address of Sole Bidder
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-3(QR)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
As per Annexure – A (BDS) – QR
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-QR
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Qualifying Requirement Data
Bidder’s Name and Address (Sole Bidder): To:
Contract & Material Department
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region Transmission System - I
SCO BAY 5-10, Sector-16
Faridabad-121002, Haryana
Dear Ladies and/or Gentlemen,
In support of the additional information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our details/documents etc., alongwith other information, as follows:
We are furnishing the following details/document in support of qualifying requirement for the subject package(s).
Qualification of bidder will be based on meeting the minimum pass/fail criteria specified below regarding the Bidder’s technical experience and financial position as demonstrated by the Bidder’s responses in the corresponding Bid Schedules. Technical experience and financial resources of any proposed subcontractor(s) shall not be taken into account in determining the Bidder’s compliance with the qualifying criteria. The bid can be submitted by an individual/ joint venture firm. At any stage of evaluation if any shortcoming/ discrepancy/ deficiency is observed in the documents/ details submitted by the bidder and or it is observed that the bidder is not meeting the stipulated QR, respective bid shall be summarily rejected. The owner may assess the capacity and capability of the bidder, to successfully execute the scope of work covered under the package within stipulated completion period. This assessment shall inter-alia include (i) Document verification; (ii) Bidder’s works visit (if required), (iii) Details of works executed, works in hand, anticipated in future & the balance capacity for the present scope of work; (iv) Details of plants and machinery, manpower and financial resources; (v) Details of quality system in place; (vi) past experience and performance; (vii) customers feedback; (viii) Banker’s feedback; etc.
0.0 Technical Experience:
1.1.1 The bidder should have successfully executed similar works (i.e civil works like PCC/RCC/Painting and other building works including services etc.) for Govt or Semi Govt. or reputed private Sector Organization within the last 7 years from the originally scheduled date of bid opening, as per following i. One single work/ project of a value of not less than Rs. 70.08 Lakhs (80% of estimated cost) or ii. Two works/ projects, each of a value of not less than Rs. 43.80 Lakhs (50% of estimated cost) or iii. Three works/ projects, each of a value of not less than Rs. 35.04 Lakhs (40% of estimated cost)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client Authorised Dealer/Sub dealer
5 Work Order Details Authorised Representative
Date Certificate of Authorized Dealership Submitted
Authorization of Manufacturer Submitted
6 Copy of Work order uploaded
Please upload Work Order Name of Manufacturer
7 Date of Completion of Work No
8 Completed amount for the work (Rs. Lakh) OBD 2016-01-05T00:00:00Z
7 Document submitted as Proof of Completion
Completion Cerificate No
8 Details of Document for Proof of Completion Any other document, authenticated by the client
Reference No. MAAT 127
9 Proof of Completion Uploaded Two Work
Please upload Proof of Completion
Work 2 (if any)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client
5 Work Order Details
6 Copy of Work order uploaded
Please upload Work Order
7 Date of Completion of Work
8 Completed amount for the work (Rs. Lakh)
7 Document submitted as Proof of Completion
8 Details of Document for Proof of Completion
9 Proof of Completion Uploaded
Please upload Proof of Completion
Work 3 (if any)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client Authorised Dealer/Sub dealer
5 Work Order Details Authorised Representative
Date Certificate of Authorized Dealership Submitted
Authorization of Manufacturer Submitted
6 Copy of Work order uploaded
Please upload Work Order Name of Manufacturer
7 Date of Completion of Work No
8 Completed amount for the work (Rs. Lakh) OBD 2016-01-05T00:00:00Z
7 Document submitted as Proof of Completion
Completion Cerificate No
8 Details of Document for Proof of Completion Any other document, authenticated by the client
Reference No. MAAT 127
9 Proof of Completion Uploaded Two Work
Please upload Proof of Completion
0.9 Financial position
Minimum Average Annual Turnover (MAAT)* of the bidder should be Rs. 131.41 Lakhs for best three financial years out of last five financial years commencing from Financial Year 2017-18. *Note: - Annual Gross revenue from operations/ gross operating income as incorporated in the profit & loss account excluding other income.
Performance Report from Client
Acceptance of Final Bill by Client
Sr. No. Financial Year Turnover (in Rs. Lakh) Copy of Balance Sheet & P/L Account Uploaded Certificate from CA
a 2017-18 Any Other (Please Specify)
Average Turnover for Best Three Years
The bidder shall furnish following documents/details with its bid a) The bidder shall submit documents in support of meeting the technical experience mentioned at Para 1.1 above in the form of LOA/ Work order & completion certificate/payment certificate or any other document evidencing the same. b) The bidder shall submit audited / certified copies of Balance Sheet and Profit and Loss account in support of meeting the financial position as mentioned at Para 1.2 . Note-I : In the event the bidder is not able to furnish the information of its own (i.e., separate), being a subsidiary company and its accounts are being consolidated with its group/ holding/ parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/ holding/ parent company) duly certified by any one of the authority [(i) Statutory Auditor of the bidder or (ii) Company Secretary of the bidder certifying that such information / documents are based on the audited accounts as the case may be). Note II: Similarly, if the bidder happens to be group/ holding/ parent company, the bidder should submit the above documents/ information of its own (i.e., exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/ documents are based on the audited accounts as the case may be.
Relaxation for MSEs/ STARTUPS MSEs^/ START-UPs^^ meeting the necessary requirements shall also be considered qualified if they meet 80% (Eighty percent) of the requirements of Minimum Average Annual financial turnover (MAAT ) for the best three financial years out of the last five financial years as above. ^MSEs as defined in bidding documents. ^^START-Ups as defined by DIPP, applicable as on the originally scheduled date of bid
1 Copy of PAN Card Uploaded
Please upload Copy of PAN Card
1.1 PAN Card Number
2 Status of the Bidder
3 MOA & AOA/ Certificate of Incorporation Uploaded
Please upload Copy of Relevent Document
Date : Printed Name :
Place : Designation :
Private Limited Company
Public Limited Company
Affidavit of Proprietorship Uploaded
Parnership Deed Uploaded
MOA & AOA/ Certificate of Incorporation Uploaded
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-4
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries],
country. country. [Name of Countries], [Name of Countries],
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Attachment-4(A)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Attachment-4(B)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-5
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/ sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract (if any) without the prior approval of Employer.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-5(A)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy / avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package.
Sl. No. Item Description Quantity Proposed to be bought / sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms & Procedures, Volume-Iof Bidding Documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Annexure I to
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-9
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
1 Detailed Engineering and drawing submission Shall be as per Delivery Schedule (Completion Period) given in SCC. Hence Not Required to be Filled here.
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-11
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We declare that we are aware of and have gone through the "Code of Business Conduct and Ethics for Senior Management Personnel" and "Code of Business Conduct and Ethics for Board Members" of POWERGRID (hereinafter referred to as the "Code of Conduct"). We further understand that as per the "Code of Conduct", Senior Management Personnel including Board Members, who have retired / resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred "Code of Conduct", within 1 year from the date of cessation of service / directorship unless approved by the Competent Authority.
Accordingly, We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder's organization of such ex-employee is within 1 year from the date of retirement / resignation from POWERGRID, No Objection Certificate / approval from the Competent Authority must be furnished alongwith the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate / approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and Procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard.
We further declare that any misrepresentation or submission of false / forged documenmts / information in this regard shall be dealt with as per the provisions of the Integrity Pact and / or the Bidding Documents and / or POWERGRID's policy and procedure.
Date : Printed Name :
Place : Designation :
1. "Code of Business Conduct and Ethics for Senior Management Personnel" and "Code of Business Conduct and Ethics for Board Members" are available on POWERGRID's website http://www.powergridindia.com.
2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid.
3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated '-' against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby confirm that the prices of Services offered by us will remain FIXED & FIRM during the performance of the contract and will not subject to any variation on any account.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
Attachment 14 Integrity Pact: To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion: NOT APPLICABLE No
Services Portion: NOT APPLICABLE No
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1 Name of the Supplier/ Contractor in whose favour payment is to be made
2 Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order [Indicate Yes / No]
Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment.
3. (c) If 3(b) is 'Yes' please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order [Indicate Yes / No]
Note: Documentary evidence is to be attached.
4 Permanent Account (PAN) No.
5 GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
9 PF Registration No. of the Company
10 PF Regional Office covered (with Address)
11 Name of Contact Person
12 Contact Details
13 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account: Saving Account
14 9 digit MICR code printed at bottom in middle, next to cheque no.
15 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
Remarks: The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC/ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited Companies, at least 51% share shall be held by SC/ST promoters.
Documentary Evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-16
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Additional Information)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
0.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3 q, Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of Bidders/JV Partners Provident Fund Code Number Details
0.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
0.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Total Liability
Current Liability
Profit before taxes
Profit after taxes
4.3 Provident Fund Code Number of the Bidder:
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-17
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-17
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contracts & Materials dept.
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. Northern Region–I, Regional Headquarter,
…… ……. …….. …… ……. …….. SCO Bay No. 5 to 10, Sector 16A,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : Printed Name :
Place : Designation : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Attachment-17
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : Printed Name :
Place : Designation : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
Attachment 18 Safety Pact: To be submitted as per ITB Clause No. 9.3(s) and as per remarks in the Attach 18.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No.: 5 five 5 th 5 May
Date: 6 six 6 th 6 June
7 seven 7 th 7 July
To: 8 eight 8 th 8 August
Contracts & Materials dept. 9 nine 9 th 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Northern Region–I, Regional Headquarter, 11 eleven 11 th 11 November
SCO Bay No. 5 to 10, Sector 16A, 12 twelve 12 th 12 December
Faridabad-121002, Haryana 13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
0.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in single envelope. ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in single envelope. 17 seventeen 17 th
0.0 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
0.0 Attachments to the Bid Form Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(a) Attachment 1: Bid Security Bank Guarantee INR Banks certified Cheque Zero 20 twenty 20 th
(b) Attachment 2 : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if bid validity is less than 07 (seven) months, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3 (QR) & Attach QR: The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). FDR 22 th
SOLE BIDDER CDR/TDR Applicable 23 th
(d) Attachment 4, 4A & 4B : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 0 Not Applicable 24 th
(e) Attachment 5 : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 25 th
(f) Attachment 5(A) : The details of the items, components, raw materials, services which we propose to buy / avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package in case of award, giving details of the name and category of the proposed Micro and Small Enterprises (MSEs).
(g) Attachment 6 : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 26 th
(h) Attachment 7 : NOT APPLICABLE The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 27 th
(i) Attachment 8 : NOT APPLICABLE Manufacturer’s Authorisation Forms. 28 th
(j) Attachment 9 : Work Completion Schedule. 29 th
(k) Attachment 10 : Guarantee Declaration. 30 th
(l) Attachment 11 : Information regarding ex-employees of Employer in our firm. 31 st
(m) Attachment 12 : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13 : Declaration regarding Social Accountability.
(o) Attachment 14 : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15 : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16 : Additional Information.
(r) Attachment 17 : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18 : Safety Pact
(t) Attachment 19 : Declaration.
(u) Attachment 20 : Declaration of Key Managerial Person jointly with Power of Attorney Holder
(v) Attachment 21 : Affidavit (submission of Hard Copy in ‘Original’) signed and stamped with company seal by a full time Director/ CEO/ Chairman-cum-Managing Director
(w) Attachment 22: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(y) Attachment 24: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1
(x) Attachment 23: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division
(y) Attachment 24: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order, if applicable
0.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
0.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
0.9 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
0.9 We also understand that, in case of award on us, you shall pay directly, if so required /reimburse to us octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items, which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit). Further, Service Tax, if applicable, for the services to be rendered by us, the same is included in our bid price in Second Envelope.
0.0 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
0.0 We confirm that no Sales Tax/VAT in any form shall be payable by you for the bought out items which shall be despatched directly by us under the First Contract (as referred in para 5.1 below) [or Letter of Award, if 5.1 Not applicable] to the project site. However, you will issue requisite Sales Tax declaration/Vatable forms in respect of such bought out items, on production of documentary evidence of registration with the concerned Sales Tax Authorities.
0.0 Construction of the Contract
0.9 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
0.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 55.0 Terms of Payment
(d) GCC 8.3 Performance Security
(e) GCC 6.0 Taxes and Duties
(f) GCC 38.0 Liquidated Damages for Delay by Contractor
(g) GCC 39.0 Guarantee
(h) GCC 40.0 Defect Liability
(i) GCC 20.5 Patents and Royalties
(j) GCC 61.0 Limitation of Liability
(k) GCC 57.0 Settlement of Disputes
(l) GCC 59.0 Arbitration
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
0.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award/Letter of Award/Work Order to us, and to achieve the completion within the time stated in the Bidding Documents.
0.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
0.0 We agree to abide by this bid for a period of 180 (One Hundred Eighty) days from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
0.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
0.0 We understand that you are not bound to accept the lowest or any bid you may receive.
0.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
0.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
0.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 (Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 (Specification No.:NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Checklist for Bid Submission
1 Soft copy of First Envelope Bid Form Duly Filled Excel Sheet of Attachment and Bid Form to be uploaded in Soft Copy along with Bid. To be submitted in Soft Copy.
2 Power of Attorney (POA) Duly notarized (on Stamp Paper of requisite value), indicating that the person(s) signing the bid has(ve) the authority to sign the bid. In case of bid submitted by a Joint Venture of two or more firms as partners, if allowed as per stipulated Qualification Requirements in Annexure-A (BDS), bidder shall submit. Power of Attorney for Joint Venture and Joint Venture Agreement as per given format Submission of Hard copy in ‘Original’and uploading of Scanned Copy
3 MSE Status Certificate (if applicable) Udyam Registration Certificate and certificate for Registration under category of Micro/Small enterpises. Submission of Hard copy and uploading of Scanned Copy
4 Bid Security The bid security shall, at the bidder’s option, be in the form of a crossed bank draft in favour of POWERGRID or a bank guarantee from a reputed bank selected by the bidder. Alternatively, same can be submitted as online payment through POWERGRID ONLINE PAYMENT UTILITY- https://epay.powergrid.in, a link of which is provided on the POWERGRID website www.powergridindia.com. The copy of ‘Online Payment Acknowledgement – Suppliers’ generated subsequent to the payment shall be submitted along with hard copy part of the bid. The format of the bank guarantee shall be in accordance with the form of bid security included in the Bidding Documents. Bid security shall be valid upto 250 days from the date of Bid Opening. The Bid Security shall be in favour of Power Grid Corporation of India Limited payable at New Delhi. Submission of Hard copy and uploading of Scanned Copy
5 Bidding Document Fee Bid document cost for amount as specified in BDS- Hard copy of document related to online payment of bid document cost as indicated in BDS or Exemption certificate to be submitted along with hard copy part of bid. Copy of the payment proof may be uploaded online on the portal. Submission of Hard copy and uploading of Scanned Copy
6 Attachment-8: Manufacturers Authorization Form Not applicable
7 Attachment-14: Integrity Pact To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
8 Attachment-18: Safety Pact To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
9 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder Signed by CEO/Managing Director/Company Secretary/ Director/ CFO/ any of the partner in case of partnership firm/ any other officer entrusted with substantial powers of the management of the affairs of the company/firm and POA Holder To be submitted in Soft Copy.
10 Attachment-21: Affidavit regarding correctness of Information To be submitted on Firm/Company's Letterhead. Signed and stamped with company seal by a full time Director/ CEO/ Chairman-cum-Managing Director and attested/ notarized by a Magistrate/ Notary for correctness of all the information/details/data/ documentary evidences etc. as submitted by the bidder are correct. To be submitted in Soft Copy.
11 Attachment-22: Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1. (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) On Firm/Company's Letterhead To be submitted in Soft Copy.
12 Attachment-23: Certification by the Bidder as per order no. F.No.6/18/2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1 (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) On Firm/Company's Letterhead To be submitted in Soft Copy.
13 Attachment 24: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) To be submitted on a non-judicial stamp paper of Rs. 100/-. Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
14 Attachment 25: Compliance for E-REVERSE AUCTION On Firm/Company's Letterhead To be submitted in Soft Copy.
15 Documents for Qualifying Requirement (QR) In support of meeting the qualifying requirements (QR) such as copy of letter of award/ work order, completion certificate, copy of audited balance sheet for five years etc., shall be uploaded by the bidder along on the portal as part of technical bid To be submitted in Soft Copy.
NOTE: This checklist is not exhaustive and issued for the purpose of reference Only. In case of any ambiguity, the provisions of Bidding Documents shall prevail.
Package Name Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Package Code RFX-5002003566
Specification No. Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
1 Fill up only green shaded cells in Sch-3 and Sch-Discount (if any) and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-4b (Maintenance Charges during and after Defect Liability Period) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Not applicable, hence no cell is required to be filled up.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Sole Bidder 1 Sole Bidder 1
Joint Venture 2 or More JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 1 0 Sole Bidder 1 0
Name of Sole Bidder …….. …….. …….. …….. …….. ……..
Address of Sole Bidder …….. …….. …….. …….. …….. ……..
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
PLANT AND EQUIPMENT (INCLUDING MANDATORY SPARES PARTS) TO BE SUPPLIED, INCLUDING TYPE TEST CHARGES FOR TESTS TO BE CONDUCTED Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘ 6 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST Tax as confirmed by Bidder
PART A (Substation Portion)
I Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 28 Included 0.00 0 0.00
23 28 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
II Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 18 Included 0.00 0 0.00
23 18 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
III Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 18 Included 0.00 0 0.00
23 18 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
IV Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
Total Ex-works Price 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 2
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
LOCAL TRANSPORTATION, IN-TRANSIT INSURANCE, LOADING AND UNLOADING
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & unloading Charges Total Freight, In-transit Insurance, loading & unloading Charges
PART A (Substation Portion)
Total F&I Price 0.00
Place: Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 2 Dis
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 3
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
CIVIL & ELECTRICAL WORKS Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
PART A (Substation Portion)
CIVIL WORKS Revaluation of J column Tax Calculation
A SUB HEAD: DISMANTLING AND DEMOLISHING 0.00 0.00
1 Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include but are not limited to, flooring, false ceiling, tiling, partitions, panelling, cladding, brickwork, concrete, RCC, plumbing, internal doors, internal windows, glazing, metal work, cabinetry, electrical work, sanitary work, light fittings, switches, cabling, fire fighting lines and risers. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal. 0 0
1.1 18 Ground Floor Wings B with Toilet Block sqm 304.00 Included 0.00 0 0
1.2 18 Third Floor Wing A and B sqm 370.00 Included 0.00 0 0
1.3 18 Third Floor Wings C and D sqm 442.00 Included 0.00 0 0
1.4 18 Third Floor Reception and Central Zone sqm 93.00 Included 0.00 0 0
1.5 18 Third Floor Toilet Block sqm 32.00 Included 0.00 0 0
1.6 18 External paver blocks and allied works sqm 3000.00 Included 0.00 0 0
2 Credit to the CLIENT for usable/unusable material that is recovered and disposed off from within the premises. Bidders MUST visit the premises and ascertain the items against which credit may be due. 0 0
2.1 18 Ground Floor Wings B with Toilet Block LS -1.00 Included 0.00 0 0
2.2 18 Third Floor Wing A and B LS -1.00 Included 0.00 0 0
2.3 18 Third Floor Wings C and D LS -1.00 Included 0.00 0 0
2.4 18 Third Floor Reception and Central Zone LS -1.00 Included 0.00 0 0
2.5 18 Third Floor Toilet Block LS -1.00 Included 0.00 0 0
3 18 Dismantling of the ACP sheet on out side building area including filling the joints with black colour silicone etc complete as per site conditions sqm 12.41 Included 0.00 0 0
B. SUB HEAD: MASONARY WORK 0 0
4 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) cum 5.36 Included 0.00 0 0
5 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) cum 62.45 Included 0.00 0 0
6 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). cum 1.00 Included 0.00 0 0
7 18 Steel Reinforcement: Thermo-Mechanically Treated bars of grade Fe-500D or more kgs 80.00 Included 0.00 0 0
8 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) cum 16.62 Included 0.00 0 0
9 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) sqm 174.03 Included 0.00 0 0
10 18 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. sqm 174.03 Included 0.00 0 0
11 18 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) sqm 95.96 Included 0.00 0 0
12 18 12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) sqm 95.96 Included 0.00 0 0
13 18 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) sqm 62.05 Included 0.00 0 0
14 18 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window sqm 12.41 Included 0.00 0 0
15 18 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. sqm 102.05 Included 0.00 0 0
16 18 Filling of sunken portion of the toilet area with Brick bats including compacting etc complete as per site conditions. Cum 21.44 Included 0.00 0 0
C SUB HEAD: STEEL WORK 0 0
17 18 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete Kg 2331.00 Included 0.00 0 0
18 18 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 261.00 Included 0.00 0 0
19 18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. Kg 10.00 Included 0.00 0 0
20 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 0 0
20.1 18 M.S. tube Kg 26.10 Included 0.00 0 0
21 18 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Kg 2000.00 Included 0.00 0 0
22 18 Providing and fixing 10mm thk toughened plain glass to be fixed to the stainless steel railing on D-brackets as per direction of Engineer In charge to the required shape and size. (For stairs) Sqm 100.00 Included 0.00 0 0
D SUB HEAD: Finishing 0 0
23 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 0 0
23.1 18 Granite of any colour and shade (Area of slab upto 0.50 sqm) sqm 128.73 Included 0.00 0 0
23.2 18 Granite of any colour and shade (Area of slab over 0.50 sqm) sqm 112.23 Included 0.00 0 0
24 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 0 0
24.1 18 Granite work metre 15.26 Included 0.00 0 0
25 18 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. metre 15.26 Included 0.00 0 0
26 18 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. each 14.00 Included 0.00 0 0
27 18 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. sqm 254.34 Included 0.00 0 0
28 18 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours as per the instructions of EIC, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. sq.m. 82.79 Included 0.00 0 0
29 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 0 0
29.1 18 Size of Tile 600x600 mm sqm 1.00 Included 0.00 0 0
29.2 18 Size of Tile 800x800 mm sqm 1.00 Included 0.00 0 0
29.3 18 Size of Tile 1000x1000 mm sqm 1.00 Included 0.00 0 0
30 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 0 0
30.1 18 Size of Tile 600x600 mm sq.m. 956.40 Included 0.00 0 0
30.2 18 Size of Tile 800x800 mm sq.m. 478.20 Included 0.00 0 0
30.3 18 Size of Tile 1000x1000 mm sq.m. 956.40 Included 0.00 0 0
31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 0 0
31.1 18 Size of Tile 600x600 mm sqm 956.40 Included 0.00 0 0
31.2 18 Size of Tile 800x800 mm sqm 478.20 Included 0.00 0 0
31.3 18 Size of Tile 1000x1000 mm sqm 956.40 Included 0.00 0 0
32 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixingAccess Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade(FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 0 0
32.1 18 300 mm Finished Floor Height (FFH) sqm 40.00 Included 0.00 0 0
33 18 Providing and fixing machine cut, mirror polished, Italian Marble stone on walls in required pattern, all complete as per architectural drawings, with 18 mm thick stone slab laid with cement based high polymer modified quick set adhesive (water based) conforming to IS: 15477, in average 6 mm thickness and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Basic Rate of stone is Rs.3767/- per sq.m. Pre-approved chemical Adhesive - for fixing on cement plaster use Keraflex Maxi S1 by Mapei. sq.m. 33.45 Included 0.00 0 0
34 18 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.: 18 mm thick. Italian Marble stone slab. Basic Rate of stone is Rs.3767/- per sq.m. sqm 50.82 Included 0.00 0 0
35 18 Providing and laying 8mm thk Laminated Wooden flooring of approved make in a design combination as per the drawing and instructions on levelled floor, insulating the areas, surface preparation, bedding, finishing etc complete as per the directions and instructions of the Engineer-in-charge. The rate shall be inclusive of edge moulding and end strips at the junction between the floor and the vertical surfaces and mouldings, T grooves and shall also include the underlays as per manufacturers specifications to achieve accoustical and thermal insulating properties etc complete. Basic Rate of Wooden laminates is Rs.3000/- per sq.m. sqm 181.33 Included 0.00 0 0
36 18 Providing and fixing 75mm high skirting in required position to be screewed to the existing walls, panelling surfaces, partitions etc including pre polished moulding etc complete as per manufacturers specifications and directions of EIC.: Laminated Wooden skirting. Basic Rate of Wooden laminates is Rs.3000/- per sq.m. sqm 13.66 Included 0.00 0 0
37 Providing and fixing Panelling on Walls, Columns, Ducts, Around Shafts etc comprising of 50.8x25.4x2.03 Aluminium rectangular hollow sections framing at a maximum spacing of 600 mm centre-centre bothways with 12mm thick Exterior Grade Particle Board. All the members shall be screwed with stainless steel screws rawl plugs etc complete required for fixing frame. All Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically. All the materials like cleat angles, mouldings, beading,.etc complete. The rate shall also include the teak wood beeding and moulding to be melamine polished including raised panels with 6mm thk ply backing wherever directed, t.w moulding etc complete. All works shall be carried out as per . drawings and the directions of Engineer-in-charge. 0 0
37.1 18 Finished with 4.0 mm thk approved Veneer with Melamine polish of approved grade as per the drawing including designed grooves etc complete. sqm 212.82 Included 0.00 0 0
37.2 18 Finished with 1.5 mm thk approved laminate as per the drawing including designed grooves etc complete. sqm 91.21 Included 0.00 0 0
38 18 Providing and fixing of 6mm thick annealed Saint Gobain Planilaque Evolution (premium GRIHA rated lacquered glass from Saint-Gobain) or of approved equivalent, fixed with SGG PlaniFIX (compatible neutral core silicon / double sided tape) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. Lacquered glass must be made industrially (via curtain coating process); opaque (if viewed against a support wall), coated with PU lacquer ; color consistency (measured by Minolta spectrophotometer CM5081); highly durable (passes PERSOZ hardness test for minimum 220 oscillatios); humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strenght (1000 MPa) & tensile strenght (40 MPa),same as float glass as per the detailed drawings and as approved by Engineer In Charge. (Lacquare Glass Panelling) Sqmt 53.76 Included 0.00 0 0
39 18 Single Glazed 12mm Toughened Glass Partition - With Alexa 100 Frame Profiles (with glass) Supply and Fixing of Single Glazed Glass partition of 12mm Toughened Glass using dormakaba Alexa System-100 Frames to a height of maximum 4m or as per drawing.The Fixed glass to be fixed using dormakaba Alexa BP100 Profiles at Top & Bottom & Alexa SP100 at sides. The profile size to be 100x25MM to be fixed on to the floor/wall/ ceiling as per the architect design.dormakaba Alexa H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design.In case of Glass overall panel Alexa OHP100 Overpanel Profile to be used.In case of Open glass edges EP100 End Profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles/Frames: dormakaba Glass : Saint Giobain/Asahi sqm 34.43 Included 0.00 0 0
40 18 Providing and fixing of Frosted Film 80 micron with adissive Permanent acrylic having UV Temperature, Humidity and salt sprey resistance. Create a translusant privacy of desired size as per the direction of Engineer-in-charge. 3M / Garware Sqm 34.43 Included 0.00 0 0
41 Providing and fixing full height double skin partitions with 12mm thk Exterior Grade Particle Board on both sides of the aluminium frame as per drawings. Main frame shall be made of aluminium square hollow section 50.8x50.8x2.4 mm and other horizontal and vertical members shall be made of aluminum rectangular hollow section 50.8x25.4x2.03 at a maximum spacing of 600 mm centre-centre including cleat angle etc. complete wherever required. All the members shall be screwed with stainless steel screws and main frame shall be fixed with rawl plugs etc complete required for fixing the partition frame to the wall or ceiling. All Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically. All works shall be carried out as per drawings and the directions of Engineer-in-charge. 0 0
41.1 18 Both sides of the partition finished with 4.0 mm thk approved veneer, finished with melamine polish of approved grade as per the drawing including designed grooves etc complete. sqm 140.04 Included 0.00 0 0
41.2 18 Both sides of the partition finished with 1.5 mm thk approved laminate as per the drawing including designed grooves etc complete. sqm 60.02 Included 0.00 0 0
42 18 Providing & fixing Urinal Modesty Panels having standard dimension of 1200 mm Height x 450 -500 mm Width and 12 mm thickness(Greenlam Sturdo of Greenlam Industries Ltd /SS Series of Merino Industries or approved equivalent) Panel starts 500-600 mm above ground level, complete with compact Laminate Board: 12 mm thick Compact Laminate (Greenlam Sturdo of Greenlam Industries Ltd /Titan Series of Merino Industries or approved equivalent) made as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard and should be heat, bacteria, water, chemical, scratch and impact resistant 12 mm thick solid compact laminate panels as per approved texture/shade. The product should have Green Guard Certificate. Including all accessories as per approval and direction of Engineer-in-Charge Modesty panels will be fixed with right angle bracket which will provided in stainless steel grade-304. (a) Right Angle Bracket b) Screws & Wall Plugs. Hardware & Fixing Nos 6.00 Included 0.00 0 0
43 18 Providing and fixing of Acoustic wall panel 600x600x25 mm shapes as per drawings, with standard fabric approved by the architect with fixing system. Colour and texture of fabric as per selection by Architect. Gyproc / Saint gobin / Armstrong sqm 67.23 Included 0.00 0 0
E. SUB HEAD: ROOFING/CEILING 0 0
44 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 0 0
44.1 18 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) sqm 469.00 Included 0.00 0 0
44.2 18 12.5 mm thick tapered edge gypsum moisture resistant board sqm 64.40 Included 0.00 0 0
45 18 Extra for above items for necessary designs and patterns in curvature, paragons, sloping, domes of any type, oval, domes with fins on all sides, reverse curves and eliptical shaped etc including the necessary provisions of coved lighting scheme, necessary frame work and supporting arrangement etc complete as per the designs, drawings and instructions of the Engineer-in-charge. No extra amount on account of any shape or design shall be entertained and the quoted rate shall be inclusive of all such designs and shapes including finishing. sqm 93.80 Included 0.00 0 0
46 18 Providing & fixing horizontal level suspended ceiling comprising of Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black / White). The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5% at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing of 100mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. Knauf/Gyproc/Armstrong make or equivalent sqm 25.00 Included 0.00 0 0
47 18 Extra for providing for suspension system hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60-80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. sqm 25.00 Included 0.00 0 0
48 18 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. sq.m. 497.00 Included 0.00 0 0
49 18 Making Grooves of size upto 15mm wide and 5mm deep in POP punning in straight lines and sharp edges as per pattern in drawings by architect. mt 100.00 Included 0.00 0 0
50 18 VENEER FALSE CEILING: Providing and erecting false ceiling in veneer with 12 mm thk commercial ply board backing on teak wood frame to be anchored to the main ceiling with cross runners tongued and grooved. The ply to be finished with approved 4mm thk veneer and melamine polish etc. complete as per directions of the Engineer-in-charge sqm 50.00 Included 0.00 0 0
51 18 Providing and fixing reflective sun control film of approved make and shade to the existing glasses as per the drawings, details and instructions of Engineer-in-charge including the adhesives etc complete. sqm 180.54 Included 0.00 0 0
F. SUB HEAD: PAINTING WORK 0 0
52 18 Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. sq.m. 608.81 Included 0.00 0 0
53 Finishing walls with textured interior paint of required shade : 0 0
53.1 18 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 150.00 Included 0.00 0 0
54 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete 0 0
54.1 18 On steel work sqm 50.00 Included 0.00 0 0
54.2 18 On concrete work sqm 100.00 Included 0.00 0 0
55 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 0 0
55.1 18 Two or more coats on new work Sqm 120.00 Included 0.00 0 0
56 18 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 82.77 Included 0.00 0 0
57 18 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. sqm 1267.81 Included 0.00 0 0
58 Two coats 0 0
58.1 18 Melamine polishing on wood work (one or more coat) sqm 100.00 Included 0.00 0 0
59 18 Providing and fixing of Wallpaper Non Woven heavy-weight 350 GSM latex saturated size 53 cmx 10 m roll including installation with required adhesive, (Artisan wall coverings/ UDC make wallpaper. Adhesive make: Bartoline) sqm 12.83 Included 0.00 0 0
G. SUB HEAD: Aluminium Composite Panel 0 0
60 18 Fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall withAluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. sqm 13.65 Included 0.00 0 0
61 18 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). Kg 75.08 Included 0.00 0 0
H. SUB HEAD: Curtain Blinds 0 0
62 18 Providing and Installing Roller Blinds with Max Width 250 cm. Length availiable as per window size. All color ready. 100 % dark Including installation at site, with Control unit of high strength of reinforced plastic with clutch of wrap spring design with high carbon steel springs for transmit motion from drive to drive members of clutch mechanism with clutch to be operated by use of endless beeded chain to rise smoothly to the required height with idler in reinforced plastic of an outside sleeves and centre to rotate freely, smoothly and long wearing operations. Both control unit and idler to be mounted on head rail with M.S brackets (Powder coated) and operating chain of 4.5mm dia and 6mm pitch and brackets to be 2mm M.S, zinc coated and clamped on 0.5mm spring steel-zinc plated and bracket to accomodate face mounting. Sqmt 180.54 Included 0.00 0 0
I. SUB HEAD: WINDOWS, FIRE DOORS AND GLAZED PARTITIONS 0 0
63.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 0 0
63.2 18 Second class teak wood cum 1.13 Included 0.00 0 0
64 18 Providing dash fastners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats) Nos 174.00 Included 0.00 0 0
65 PProviding and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 0 0
65.1 18 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 34.86 Included 0.00 0 0
65.2 18 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 12.96 Included 0.00 0 0
66 18 Providing and fixing 4 mm thk approved veneer on one side and 1.5 mm thk approved laminate on the other side of the exposed surfaces of the flush door shutters including finihshing the veneer with melamine polish of desired shade. The rate shall include the adhesives, labour, materials, nails, screws etc complete and nothing extra shall be paid on this account as per the directions and instructions of the E-I-C. (The rate quoted shall be for the cumulative quantity and only one side area shall be measured for payment). sqm 34.86 Included 0.00 0 0
67 18 Providing and fixing 4 mm thk approved veneer on both sides of the shutters of the flush door shutters including finihshing the same with melamine polish of desired shade. The rate shall include the adhesives, labour, materials, nails, screws etc complete and nothing extra shall be paid on this account as per the directions and instructions of the E-I-C. (The rate quoted shall be for the cumulative quantity and only one side area shall be measured for payment). sqm 12.96 Included 0.00 0 0
68 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 0 0
68.1 18 2nd class teak wood: 50x12 mm meter 50.00 Included 0.00 0 0
68.2 18 3rd class teak wood: 50 x 20 mm meter 50.00 Included 0.00 0 0
69 18 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). sqm 5.19 Included 0.00 0 0
70 18 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. Nos 4.00 Included 0.00 0 0
71 18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, including handles (600x 22mm) on both sides, lock patch fittings, etc. all complete as per direction of Engineer-incharge. Dormakaba / Godrej / Kich make or equivalent Sqm 20.25 Included 0.00 0 0
72 Providing and fixing satin finish Stainless steel tower bolts, ISI marked, colour or shade, with necessary screws etc. complete : 0 0
72.1 18 300x12 mm Nos 20.00 Included 0.00 0 0
73 18 Providing and fixing of stainless steel 304 grade of make PULL HANDLES 300 x 22mm, SS 304, Finish : Satin with necessary screws etc. complete. Dormakaba / Godrej / Kich make or equivalent Nos 40.00 Included 0.00 0 0
74 18 Provinding and fixing of Pull Handle for Door 600 MM length in Stainless Steel finish fixed on one side of the door with necessary screw etc. Nos 4.00 Included 0.00 0 0
75 18 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.: Triple strip vertical type Nos 8.00 Included 0.00 0 0
76 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete 0 0
76.1 18 Twin rubber stopper Nos 20.00 Included 0.00 0 0
77 18 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Nos 20.00 Included 0.00 0 0
78 18 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). metre 26.00 Included 0.00 0 0
79 18 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). sqm 12.05 Included 0.00 0 0
80 18 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of SUB HEAD : 9.0 WOOD AND P.V.C. WORK 206 Code Description Unit Rate No. E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. sqm 0.90 Included 0.00 0 0
81 18 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. Nos 5.00 Included 0.00 0 0
82 Automatic Sliding Door with ST Flex Frames Motorized Sliding Framed Glass Door Providing and fixing Automatic Sliding door operator, Make: DORMA ES 200 Easy 6250, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested for durability of 1 Million Cycles, tested according to the low voltage guidelines, fulfils DIN 18650 standards, for framed glass door application with DORMA ST-Flex Profiles Systems, modular design including internal cover and with 12mm toughened glass for 2 Nos sliding door panels with DORMA ST-Flex framed profile system with Interlocking Seals. Operator & Frame Finish should be in Black, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening size given below. DORMA ES200 Easy Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting. The track profile should be separate from the main profile for enabling reduction in vibration insulation, With backplate for easy Installation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, with SMPS, Class of protection IP 20. IXIO Sensor System. With Electro-mechanical locking, Bistable, Program Switch with Key. ES 200 Easy, Max Panel Weight Carrying Capacity of 2 X 100 Kgs. The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below: Pre-approved make: DORMA ES 200 Easy 6250 Automatic with ST Flex or equivalent 0 0
82.1 18 SLD (Door portion) sqm 10.08 Included 0.00 0 0
83 18 Double Leaf Aluminium Glazed Door of 12mm Toughened Glass with Alexa System-100 Frame Profile Supply & Fixing of Aluminium Glazed Door (Double Leaf) of 12mm Toughened Glass with dormakaba Alexa System-100 frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Alexa STP100 Door Profile frame with clips & seals with dormakaba Flush Hinges (8 Nos) , TGDI D type Offset Pull Handle 600mm x25mm, CTC - 600mm, D -25mm, Back to back fixing (2 Pairs), 917 Narrow stile Dead Lock package (1 Set), ITS Concealed Door closer (as per EN 1154) with Hold Open unit (2 Nos), Manual Flush bolt for Metal doors 172mm (with 300mm length rod) - 1 No, Manual Flush bolt for Metal doors 172mm (with 600mm length rod) - 1 No, Dust proof floor socket for flush bolt (1 No), Automatic door bottom RP8si seal (2 Nos). Necessary seals to be provided all around the door frames. For doors part DP100-SG Door rebate profile to be used.In case of Glass overall panel Alexa OHPDP100-SD/DG Over Panel Door profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles /Frames: dormakaba or equivalent Glass : Saint Giobain/Asahi/ Modiguard sqm 5.04 Included 0.00 0 0
84 18 Single Leaf Aluminium Glazed Door of 12mm Toughened Glass with Alexa System-100 Frame Profile. Supply & Fixing of Aluminium Glazed Door (Single Leaf) of 12mm Toughened Glass with dormakaba Alexa System-100 frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Alexa STP100 Door Profile frame with clips & seals with dormakaba Flush Hinges (4 Nos) , TGDI D type Offset Pull Handle 600mm x25mm, CTC - 600mm, D -25mm, Back to back fixing (1 Pairs), 917 Narrow stile Dead Lock package (1 Set), ITS Concealed Door closer (as per EN 1154) with Hold Open unit (1 No), Automatic door bottom RP8si seal (1 No). Necessary seals to be provided all around the door frames. For doors part DP100-SG Door rebate profile to be used.In case of Glass overall panel Alexa OHPDP100-SD/DG Over Panel Door profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles /Frames: dormakaba or equivalent Glass : Saint Giobain/Asahi/ Modiguard sqm 2.52 Included 0.00 0 0
85 Providing and fixing aluminium glazed door, windows partly fixed partly openable/ sliding /fixed/openable System AW 40.NI The system is non-Thermal Break and with a basic depth of 40mm. Pre-approved model: Alpha series by AGValfab. HARDWARE: HANDLE / HINGES MAKE : ASSA ABLOY/ PULSE EPDM MAKE : SCHUCO or equivalent 0 0
85.1 18 External wall window W1 (1500x1500) Nos 5.00 Included 0.00 0 0
85.9 18 Staff Toilet V1 (860 X 900) Nos 2.00 Included 0.00 0 0
85.10 18 Jaintor room and ladies toilet V2 (600 X 1200) Nos 4.00 Included 0.00 0 0
J. SUB HEAD: PLUMBING & SANITARY FITTINGS 0 0
86 18 Providing and fixing white vitreous china wall mounting type water closet of size 595x385x385 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 liter / 6 liter ( adjustable to 2 liter / 4 liter ) including seat cover & cistern fittings nuts , bolts and gaskets etc complete . ( Make and Model : Roca (THE GAP) RS346477460, Flush Plate - Slendra Plus Push Plate Roca - RE890195001 , Concealed Stop Cock Jaquar LYR - 38083 K , Concealed Cistern Dual Flush -Roca RE890010200. Each 14.00 Included 0.00 0 0
87 18 Providing and fixing White Table Top Ractanguler Wash Basin Size 550 x 370 mm with 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : ( Make and Model : Inspira W B soft 550 x 370 S Ins White- RS 327504000), Bottle Trap ECO - RF9066A1 Each 6.00 Included 0.00 0 0
88 18 Providing and fixing White Viterous China under counter Wash Basin Berna undercounter B 560x 420 White with 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : (Make and Model : RS 32 7871461) + Bottle Trap ECO - RF9066A1. Each 8.00 Included 0.00 0 0
89 18 RCC Counters: Providing and fixing 65 mm thick RCC (mix 1:2:4) countertops in kitchen, toilet etc. including 8 mm reinforcement in both directions @ 100mm C/C. The slab must have min bearing of 65 mm in brick masonry walls. (Additional 115 mm thick support wall shall be paid for separately). Rate to include for scaffolding, formwork, openings for sinks, basins, taps etc. chasing in brick masonry complete. sq.m. 10.00 Included 0.00 0 0
90 18 MS Framing for Vanity Counters: Providing and fixing MS frames and supports for toilet vanity as per "Vanity Counter Support Frame Designed for 100kg" as per specification provided by Saint Gobain in Detailed Specification Document. Frames shall be made of MS RHS (50 x 25 x 3.6mm), 8mm thick base plates, gusset plates 200x100x5mm all painted with red oxide primer and fixed to the GI drywall partition frame and RCC floor slab with necessary screws, bolts, fasteners etc. all complete to the satisfaction of the engineer-in-charge nos 4.00 Included 0.00 0 0
91 18 Providing and fixing Single Lever Wash Basin Mixer Automatic Tap cum Auto Soap Dispenser 2 in 1 with thermostat mixer valve cutting and making good the walls wherever require : ( Make and Model : Euronics KSDT6 & Euronics HCT02 ) Each 14.00 Included 0.00 0 0
92 18 Providing and fixing health faucet CP flexible hose 1000 mm nozzles and swivel hook with CP brass wall flange and CP holder including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : Roca RF9060A1) Each 14.00 Included 0.00 0 0
93 18 Providing and fixing 15 mm dia C.P. brass angle valve for health faucet , wash basin mixer and geyser points with CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : RF525164500 ) Each 64.00 Included 0.00 0 0
94 18 Providing and fixing Toilet Paper Holder CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : ROCA RA816713001) Each 14.00 Included 0.00 0 0
95 18 Providing & Fixing Stainless Steel type 304 towel ring 18-8 with C.P. brass round wall flanges & CP brass screws complete in all respect as per direction of engineer - in - charge . ( Make and Model : ROCA RA816070172) Each 6.00 Included 0.00 0 0
96 18 Providing and fixing of fully automatic "NO TOUCH" hand drier Stainless Steel Body suitable to operate on 220 volts, single phase 50 hz, A.C. power supply and directly plugged to power point complete. (Make and Model : Euronics PLUTO PHD 501) Each 4.00 Included 0.00 0 0
97 18 Providing & Fixing Stainless Steel type 304 twin coat hook 18-8 with C.P. brass round wall flanges & CP brass screws complete in all respect as per direction of engineer - in - charge . (Make and Model : Euronics EC 02) Each 12.00 Included 0.00 0 0
98 18 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 425 x797 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. ( Make and Model : ROCA Euret urinal sensor (BAT) Each 6.00 Included 0.00 0 0
99 Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug . ( Make and Model - Jaquar ELENA Vertical / Horizontal) 0 0
99.1 18 6 Litre Capacity Each 8.00 Included 0.00 0 0
99.2 18 15 Litre Capacity Each 2.00 Included 0.00 0 0
100 18 Providing & Fixing surface mounted hydration station 960(H) x 413(W) x 473(D) made of stainless steel having storage capacity of 60 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge . Hydration station OASIS VERSA FILLER-P8SBFY, RO- Oasis 50LPH RO SYSTEM, Pressure tank - Oasis HPT TANK 60LTR with accessories Each 2.00 Included 0.00 0 0
101 18 Providing and fixing Stainless Steel Sanitary Napkin Hygiene Panel 3 in 1 For Feminine washroom CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . (Make and Model : ESN03S) Each 2.00 Included 0.00 0 0
102 18 Providing and fixing Stainless steel paper dispenser( Capacity 450 - 500 Paper Towel ) wherever required complete in all respect as per direction of engineer in charge. (Make and Model : Euronics EP 23 ) Each 10.00 Included 0.00 0 0
103 18 Providing and fixing 6mm thick clear mirror with bevelled edge mounted on 12mm thick plywood with ARALDITE. Rate to include for glue, anchor fasteners to fix ply to wall etc. all inclusive sq.m. 14.90 Included 0.00 0 0
K. SOIL , WASTE VENT AND RAIN WATER PIPE 0 0
104 Providing and fixing uPVC 6kg/cm2 Soil , Waste & RWP pipes (IS: 13592 Class B) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces as per IS : 14735 jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good wherever required. 0 0
104.1 18 110 mm OD Metre 104.30 Included 0.00 0 0
104.2 18 160 mm OD Metre 60.00 Included 0.00 0 0
105 Providing and fixing uPVC waste pipes 6 Kg / cm2 for WB , SINK , URINAL , FD (IS: 4985 Class III ) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces as per IS : 4985 jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good wherever required. 0 0
105.1 18 65 mm OD Metre 27.20 Included 0.00 0 0
106 Providing & fixing in position upvc P"or S" trap of self cleaning design of following sizes for the embedded areas Making proper connection with chemical sealent joint , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors wherever required. 0 0
106.1 18 110 mm inlet and 110 mm outlet Each 14.00 Included 0.00 0 0
107 Providing & fixing in position upvc floor drain including cost of cutting and making good the walls and floors wherever required. 0 0
107.1 18 110 mm inlet and 63 mm outlet Each 33.00 Included 0.00 0 0
108 18 Providing and fixing Chrome Polished Floor Drain (SS Jali) Anti Order, Blockage and Overflow Seal floor drain cover in chrome finish. The installation shall be done to the satisfaction / approval of Engineer-in-charge. Each 32.00 Included 0.00 0 0
L. INTERNAL WATER SUPPLY 0 0
109 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.: Concealed work, including cutting chases and making good the walls etc. 0 0
109.1 18 15 mm nominal outer dia Pipes Metre 14.06 Included 0.00 0 0
109.2 18 20 mm nominal outer dia Pipes Metre 112.85 Included 0.00 0 0
109.3 18 25 mm nominal outer dia Pipes Metre 100.00 Included 0.00 0 0
109.4 18 32 mm nominal outer dia Pipes Metre 100.00 Included 0.00 0 0
110 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 0 0
110.1 18 40 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
110.2 18 50 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
111 Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 0 0
111.1 18 25 mm dia nominal bore Each 30.00 Included 0.00 0 0
111.2 18 32 mm dia nominal bore Each 2.00 Included 0.00 0 0
111.3 18 40 mm dia nominal bore Each 1.00 Included 0.00 0 0
111.4 18 50 mm dia nominal bore Each 1.00 Included 0.00 0 0
M. External Finishing 0 0
112 18 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) METER 300.00 Included 0.00 0 0
113 18 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. sqm 3000.00 Included 0.00 0 0
ELECTRICAL WORKS ELECTRICAL WORKS 0 0
A. SWITCH CONTROL LIGHT POINTS 0 0
1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(For Concealed Wiring) 0 0
1.1 18 Group A Points 61 Included 0.00 0 0
1.2 18 Group B Points 100 Included 0.00 0 0
1.3 18 Group C Points 50 Included 0.00 0 0
2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 0 0
2.1 18 Group A Points 100 Included 0.00 0 0
2.2 18 Group B Points 20 Included 0.00 0 0
2.3 18 Group C Points 15 Included 0.00 0 0
B. MCB CONTROL LIGHT POINTS 0 0
3 18 Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr. 950 Included 0.00 0 0
4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 0 0
4.1 18 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Mtrs 60 Included 0.00 0 0
4.2 18 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Mtrs 1650 Included 0.00 0 0
4.3 18 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Mtrs 200 Included 0.00 0 0
4.4 18 4x 10 sqmm+ 2x 6 sqmm earth wire Mtrs 250 Included 0.00 0 0
4.5 18 4x 16 sqmm+ 2x 6 sqmm earth wire Mtrs 175 Included 0.00 0 0
5 Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required. 0 0
5.1 18 25 mm dia. Mtrs. 450 Included 0.00 0 0
5.2 18 32 mm dia. Mtrs. 100 Included 0.00 0 0
6 Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 0 0
6.1 18 5/6 amps switch Each 261 Included 0.00 0 0
6.2 18 3 pin 5/6 amp socket outlet Each 10 Included 0.00 0 0
7 18 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Each 20 Included 0.00 0 0
8 Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 0 0
8.1 18 1or 2 module (75mmx 75mm) Each 10 Included 0.00 0 0
8.2 18 3 module (100mmx 75mm) Each 10 Included 0.00 0 0
8.3 18 4 module (125mmx 75mm) Each 30 Included 0.00 0 0
8.4 18 6 module (200mmx 75mm) Each 10 Included 0.00 0 0
8.5 18 8 module (200mmx 125mm) Each 5 Included 0.00 0 0
9 18 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. Each 160 Included 0.00 0 0
10 18 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. Each 140 Included 0.00 0 0
11 18 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required. Each 65 Included 0.00 0 0
C. SUB HEAD: DISTRIBUTION BOARD 0 0
12 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 0 0
12.1 18 6 way (4+18),Double door Each 6 Included 0.00 0 0
12.2 18 8 way (4+24),Double door Each 6 Included 0.00 0 0
13 Supplying & fixing 5 amps to 32 amps rating 240/415 volts C curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0 0
13.1 18 Single Pole Each 180 Included 0.00 0 0
14 18 Supply & fixing of single pole blanking plate in the existing MCB DB complete etc. as required Each 10 Included 0.00 0 0
15 Supplying and fixing of following rating four pole 415 V isolator in the existing MCB DB complete with connections ,testing and commissioning etc as required. 0 0
15.1 18 40 amps Each 6 Included 0.00 0 0
15.2 18 63 amps Each 6 Included 0.00 0 0
16 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0 0
16.1 18 40 Amps Each 18 Included 0.00 0 0
16.2 18 63 Amps Each 18 Included 0.00 0 0
D. SUB HEAD: CABLE TRAYS & RACEWAYS 0 0
17 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.. 0 0
17.1 18 150 mm width X 50 mm depth X 1.6 mm thickness Mtrs. 30 Included 0.00 0 0
17.2 18 450 mm width X 50 mm depth X 2.0 mm thickness Mtrs. 50 Included 0.00 0 0
18 S/ F powder coated of approved shade MS Cable Tray Tee's 0 0
Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 0 0
18.1 18 300 mm width X 50 mm depth X 1.6 mm thickness Nos. 3 Included 0.00 0 0
Fabricating supplying to site of installation, in floor including chase cutting of floor,leveling, refilling and making good the same from 1.6 mm thick and 2 mm thick cover pregalvanised MS CRCA sheet, totally enclosed, height 40 mm . The two lengths of raceways shall be fitted with Collars , 50 mm wide, 3 mm thick , press fit type. The raceways shall be clamped to the floor slab with GI clamps , 3mm thick and shall be screwed to the floor slab. The joint between raceway and junction box will be made with GI flexible strip( 3 nos), 3 mm thick, 4 inches long ,15 mm wide which will be nut bolted to the Junction box complete as required etc. 0 0
19.1 18 100 mm x 40 mm x 2 mm thick RM 10 Included 0.00 0 0
19.2 18 150 mm x 40 mm x 2 mm thick RM 135 Included 0.00 0 0
19.3 18 200 mm x 40 mm x 2 mm thick RM 24 Included 0.00 0 0
19.4 18 300 mm x 40 mm x 2 mm thick RM 48 Included 0.00 0 0
20 Junction box 0 0
Fabricating supplying to site of installation, Junction boxes for floor raceways made from 2 mm thick , with 2.5 mm thick G.I. cover including providing neoprene gaskets between the cover and the junction box, cadmium plated flat/round head screws, height as per site condition,totally enclosed. Proper cutouts shall be made in the side walls for raceway entry wherever required. The junction box shall be all side walls should be welded expect top cover and all side walls shall have suitable size of rectangular knock out holes for taking raceways / conduits as required and not a complete cut out. The top cover should be sealed with M Seal to make it dust and water proof complete as required etc. 0 0
20.1 18 200 mm x 200 mmx 40 mm (height) Nos. 35 Included 0.00 0 0
20.2 18 250 mm x 250 mmx 40 mm (height) Nos. 9 Included 0.00 0 0
20.3 18 350 mm x 500 mmx 40 mm (height) Nos. 3 Included 0.00 0 0
E. SUB HEAD : LIGHT FIXTURES 0 0
21 18 Supply, Installation, Testing and Commissioning of Philips Essential full glow 2x2 Panel 30w - 40w RC360B LED36S. Philips or Equivalent make Nos. 141 Included 0.00 0 0
22 18 Supply and Installation of Profile Recessed luminaire Slash with HE-High Efficiency LED(Light Emitting Diode) system power: 14W, luminous flux of luminaire 1400lm, colour temperature of 4000K, neutral white,CRI>80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, direct light emission,luminaire profile in anodised aluminium, pre-wired batten luminaire,opal APD (Added Performance Diffuser) diffuser for a homogenous light distribution, ZHLS(ZERO HALOGEN LOW SMOKE) internal wiring, integral electronic control gear, Protection class I, IP40 L = 1178 mm, EL = 1190 B = 48 mm, EB = 61mm, H = 70 mm LED0571RA1411780014J7 Mtr 26.4 Included 0.00 0 0
23 18 Supply, Installation, Testing and Commissioning of 15W-20w Recess Mounted LED circular Downlighter (Cat no- Philips Lighting DN296B LED15S-6500 PSU WH) Philips or Equivalent make Nos. 143 Included 0.00 0 0
24 18 Supply, Installation, Testing and Commissioning of 5W-3w Recess Mounted LED circular Downlighter (Cat no- Philips Lighting DN296B LED12S-6500 PSU WH) Philips or Equivalent make Nos. 15 Included 0.00 0 0
25 18 Supply, Installation, Testing and Commissioning of 5W/mtr. Cove light (LED STRIP LIGHTS-(Cat no- Philips Lighting LED Strip SKYCove 5M WW with driver) Philips or Equivalent make 25 Nos Mtrs 75 Included 0.00 0 0
26 18 Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. Nos. 14 Included 0.00 0 0
F. High End Electrical 0 0
27 18 Supplying and fixing pop up box 8 (2x4) Module Legrand 054023 Brushed Stailness Steel Finish plate with Box for installation on Table Top. Accessories / fittings to be paid for seperately. Each 12 Included 0.00 0 0
28 18 Design, manufacturing and supplying and commissioning of LT Panel (415V) cubicle type Out Door Type as per technical specification and comprising of the following (Refer schematic diagram of LT panel) The panel shall be FRONT operated, suitable for bus duct entry for incomings & outgoing cable entry from the bottom. The fault with standing capacity shall be 50 KA. Continuous earth bus shall be provided with the LT panel board complete as required with following: (A) INCOMER 1 No 250 Amp FP MCCB, 25 kA breaking capacity with Thermal release and rotatry handle. (B) METERING & INDICATION (i) 1 set of R,Y,B phase indicating lamps (ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB (iii) 1 No. (0-300 A) Ammeter with ASS with 3 nos. 250/5A CT's (C) BUS-BAR 1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves (D) OUTGOINGS (i) 4 Nos. 40 Amp FP MCB, 10 kA breaking capacity (ii) 8 Nos. 63 Amp FP MCB, 10 kA breaking capacity Complete with copper wire connection from busbar to out going connector block as rerquired . (iii) 2 Nos 125 Amp TPN MCCB, 25 KA breaking capcity . Set 1 Included 0.00 0 0
29 18 Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications. 3½ x 70 sq. mm ( Assume for Incomming cable for HVAC Panel ) RM 100 Included 0.00 0 0
30 18 Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications. 3½ x 150 sq. mm ( Assume for Incomming cable for HVAC Panel ) RM 200 Included 0.00 0 0
31 18 Laying and fixing of one no PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on Cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Mtrs. 100 Included 0.00 0 0
32 18 Laying and fixing of one no PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size on Cable tray as required. Above 120 sq. mm and upto 185 sq. mm (clamped with 25x3mm MS flat clamp) Mtrs. 200 Included 0.00 0 0
33 18 Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required. 3½ x 70 sq. mm Set 4 Included 0.00 0 0
34 18 Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required. 3½ x 150 sq. mm Set 6 Included 0.00 0 0
35 18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. RM 100 Included 0.00 0 0
G. SUB HEAD: STRUCTURED CABLING SYSTEM PASSIVE 0 0
36 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 0 0
36.1 18 1 run of cable Mtr 1000 Included 0.00 0 0
36.2 18 2 run of cable Mtr 3000 Included 0.00 0 0
36.3 18 3 run of cable Mtr 5000 Included 0.00 0 0
37 18 Supply , Installtion , Testing and Comissioning of CAT6 information outlet (I/O) for Camera at user end. Nos. 270 Included 0.00 0 0
38 18 Supply, Installation, Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end. Nos. 6 Included 0.00 0 0
39 18 Supply, Installation, Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Nos. 270 Included 0.00 0 0
40 18 Supply, Installation, Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity. Nos. 270 Included 0.00 0 0
41 18 Supply, Installation, Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Nos. 270 Included 0.00 0 0
42 18 Supply, Installation, Testing and Commissioning of 42 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Nos. 3 Included 0.00 0 0
43 18 Supply & fixing of single HDMI port. Nos. 15 Included 0.00 0 0
44 18 Supply & laying of HDMI Cable 3 mtr. Nos. 15 Included 0.00 0 0
45 18 Supply & laying of HDMI Cable 20 mtr. Nos. 15 Included 0.00 0 0
H. SUB HEAD: MULTI ANTENNA AV SYSTEM 0 0
46 Supply and fixing following signal outlets with grid plate in 2 mm thick GI box complete including cutting, chases, fixing of GI boxes and making good. (Cover plate shall match the colour, size and make of wiring accessories to be used in the project). 0 0
46.1 18 TV Signals outlet Nos 10.00 Included 0.00 0 0
47 18 Supply, laying, connecting and commissioning of RG-11 co-axial cable of MATV as per specification in existing MS conduit RM 150.00 Included 0.00 0 0
48 18 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. RM 675.00 Included 0.00 0 0
49 Supply Installation Testing & Commissioning of Splitters as required. 0 0
49.1 18 2-Way Splitter Nos 5.00 Included 0.00 0 0
49.2 18 4-Way Splitter Nos 2.00 Included 0.00 0 0
50 Supply Installation Testing & Commissioning of Tap-off Box as required. 0 0
50.1 18 2-Way Tap-off Box Nos 5.00 Included 0.00 0 0
50.2 18 4-Way Tap-off Box Nos 5.00 Included 0.00 0 0
51 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 0 0
51.1 18 25 mm dia. RM 150.00 Included 0.00 0 0
I. Variable Refrigerant Flow Air-conditioning System 0 0
52 Outdoor Units 0 0
52.1 18 Supply ,Installation,Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s) , minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant,vibration isolators, with suitable foundation etc.complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%, 3Phase, 50HzAC power supply. The unit shall be filled with first charge of the refrigerant andready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . Per HP 116 Included 0.00 0 0
53 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0 0
53.4 18 1.6 TR Each 4 Included 0.00 0 0
53.5 18 2.0 TR Each 18 Included 0.00 0 0
53.8 18 3.2 TR Each 2 Included 0.00 0 0
54 18 4.0 TR Each 10 Included 0.00 0 0
54 Copper Refrigerant Piping 0 0
541 Supply,Installation,testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF or Non VRV/VRF system, complete with fittings,with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications 0 0
54.2 NOTE:-1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2)Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe. 0 0
54.3 18 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 65 Included 0.00 0 0
54.4 18 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 95 Included 0.00 0 0
54.5 18 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 110 Included 0.00 0 0
54.6 18 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 95 Included 0.00 0 0
54.7 18 19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 65 Included 0.00 0 0
54.8 18 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 70 Included 0.00 0 0
54.9 18 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 55 Included 0.00 0 0
54.1 18 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation M 75 Included 0.00 0 0
54.11 18 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 50 Included 0.00 0 0
54.12 18 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 60 Included 0.00 0 0
54.13 18 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 25 Included 0.00 0 0
54.14 18 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation M 20 Included 0.00 0 0
55 DRAIN PIPING 0 0
55.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVCsolventcement and testing of joints complete as per direction of Engineer in Charge. 0 0
55.2 18 25 MM Nominal Outerdia Pipes M 90 Included 0.00 0 0
55.3 18 32 MM Nominal Outerdia Pipes M 80 Included 0.00 0 0
56 Insulation material for Drain Pipe 0 0
56.1 Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suiatable adhesive, as per specifications and as required complete in all respect. 0 0
56.2 18 19 mm Sqm 180 Included 0.00 0 0
57 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 0 0
57.1 18 100 mm width X 50 mm depth X 1.6 mm thickness M 70 Included 0.00 0 0
57.2 18 150 mm width X 50 mm depth X 1.6 mm thickness M 50 Included 0.00 0 0
57.3 18 200 mm width X 50 mm depth X 1.6 mm thickness M 30 Included 0.00 0 0
57.4 18 300 mm width X 50 mm depth X 1.6 mm thickness M 30 Included 0.00 0 0
57.5 18 450 mm width X 50 mm depth X 1.6 mm thickness M 20 Included 0.00 0 0
58 18 Providing and fixing G.I tape 20mm x 3 mm thick onparapet or surface of wall for lightning conductor complete as required. (For horizontal run) M 540 Included 0.00 0 0
59 Factory fabrication GSS Duct 0 0
59.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 0 0
59.2 18 Thickness 0.63 mm sheet (24 Gauge) Sqm 8 Included 0.00 0 0
59.3 18 Thickness 0.80 mm sheet (22 Gauge) Sqm 12 Included 0.00 0 0
60 16 G GI VCD 0 0
60.1 18 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws inkages, flanges etc, as per specifications. Sqm 2 Included 0.00 0 0
61 Supply air Grill 0 0
61.1 18 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. Sqm 12 Included 0.00 0 0
62 Duct Inside Acoustic lining 0 0
62.2 18 Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. Sqm 4 Included 0.00 0 0
63 Supply,installation,testing and commissining of direct driven Tube axial flow fans suitable for installing in any position in Horizontal or vertical with adjustable pitch blade, MS / high duty GSS long Casing , cast aluminium alloy impeller complete with TEFC Sq. Cage Induction type IE 2 motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 Pole, three phase A.C supply of class "F" insulation motor's winding with support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep with 25 mm slack at Outlet etc.. 0 0
63.1 For Make Up air in Common Corridor ( In Case of Fire ) 0 0
63.2 18 5000 CFM / 15 mm St. Press. Nos 2 Included 0.00 0 0
63.3 18 4000 CFM / 15 mm St. Press. Nos 2 Included 0.00 0 0
64 Supply, installation, testing and commissioning of Inline Fan with centrifugal blower and motor encased in sheet metal casing, as per specifications. The motor shall be suitable for 220 ± 6% V, 50 Hz AC supply. The price shall include fan speed regulator and cowl with bird screen and electrical wiring from socket to fan considering 3 m distance between socket and fan. 0 0
64.1 18 600 CFM / 15 mm St. Press. - For Toilet Exhaust Nos 10 Included 0.00 0 0
65 18 Supply,installation, testing and commissionig of refrigerant Copper Y-joints. Set 60 Included 0.00 0 0
66 18 Refrigerant R-410A to top up the system if required. Kg 50 Included 0.00 0 0
67 HVAC Panel - For ODU at Terrace 0 0
67.1 Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabrication 0 0
67.2 INCOMING : 0 0
67.3 One No. 400 amps, 35 ka, 4-pole MCCB complete with adustable overload circuit protection. 0 0
67.4 96 x 96 mm square MFM digital type 1 Set 0 0
67.5 Phase indicating lamps with control SP MCB. 0 0
67.6 Aluminum bus bar sleeve type rated at 800 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacity 0 0
67.7 Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for smoke extraction axial fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. 0 0
67.8 OUTGOING : 0 0
67.9 4 Nos 40 amps, 25 k, TPN MCCB with single phase /overload circuit protection. 0 0
67.1 4 Nos 63 amps, 25 k, TPN MCCB with single phase /overload circuit protection. 0 0
67.11 18 2 Nos 100 amps, 25 k, TPN MCCB with single phase /overload circuit protection. Set 1 Included 0.00 0 0
68 HVAC PANEL-2, Emergency panel For Pressurization system & Outgoing feeder for Starter panel of Fresh Air & Smoke Exhaust fans at each floor 0 0
68.1 Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabrication 0 0
68.2 Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for smoke extraction axial fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. 0 0
68.3 INCOMING : 0 0
68.4 One No. 125 amps, 25 ka, 4-pole MCCB complete with adustable overload circuit protection. 0 0
68.5 0-500 Volts 96 x 96 mm square voltmeter digital type with selector switch 1 Set 0 0
68.6 0-200 amps ammeter digital type with 200/5 amps CT's and selector switch 1 Set 0 0
68.7 Phase indicating lamps with control SP MCB. 0 0
68.8 Aluminum bus bar sleeve type rated at 250 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacity 0 0
68.9 OUTGOING : 0 0
68.1 4 Nos. 25 Amps MCB DOL Starter for Supply Fan's Motor, over load relay with built in single phasing protection. The compartment shall contain an indicating lamp with MCB for ‘ON’ status. 0 0
68.11 4 Nos. 16 Amps MCB DOL Starter for Supply Fan's Motor, over load relay with built in single phasing protection. The compartment shall contain an indicating lamp with MCB for ‘ON’ status. 0 0
68.12 18 6 Nos 32 amps, 25 k, TPN MCCB with single phase /overload circuit protection. Set 2 Included 0.00 0 0
69 Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabrication 0 0
69.1 Note: The AC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder for smoke extraction axial fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him. 0 0
69.2 INCOMING : 0 0
69.3 One No. 32 amps, 25 ka, 4-pole MCCB complete with adustable overload circuit protection. 0 0
69.4 0-500 Volts 96 x 96 mm square voltmeter digital type with selector switch 1 Set 0 0
69.5 0-40 amps ammeter digital type with 32/5 amps CT's and selector switch 1 Set 0 0
69.6 Phase indicating lamps with control SP MCB. 0 0
69.7 Aluminum bus bar sleeve type rated at 63 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacity 0 0
69.8 OUTGOING : 0 0
69.9 18 2 Nos. 16 Amps MCB DOL Starter for Fan's Motor, over load relay with built in single phasing protection. The compartment shall contain an indicating lamp with MCB for ‘ON’ status. Set 4 Included 0.00 0 0
70 POWER CABLING 0 0
70.1 Supply,of following 1100 volt grade PVC insulated copper conductor armoured cable on cable trays, existing trenches, burried cables including the cost of providing identification tags,route markers etc. complete as per specification and as per site requirements. 0 0
70.2 For Outdoor unit 0 0
70.3 18 4C x 25 Sq. mm RMT 70 Included 0.00 0 0
70.4 18 4C x 16 Sq. mm RMT 50 Included 0.00 0 0
70.5 18 4C x 10 Sq. mm RMT 60 Included 0.00 0 0
70.6 18 4C x 6 Sq. mm RMT 35 Included 0.00 0 0
70.7 18 4C x 4 Sq. mm RMT 150 Included 0.00 0 0
71 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 0 0
71.1 18 Upto 35 sq. mm RMT 1265 Included 0.00 0 0
72 Supply,laying,testing and commissioning of following copper PVC insulated, sheathed unarmoured cable for indoor unit/inline fans.Cabling between 15 amp Switch socket outlet and each of the indoor units shall also be included in this cost. 0 0
72.1 18 3C x 2.5 Sq. mm RMT 300 Included 0.00 0 0
73 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 0 0
73.1 18 4C x 25 Sq. mm Nos 15 Included 0.00 0 0
73.2 18 4C x 16 Sq. mm Nos 20 Included 0.00 0 0
73.3 18 4C x 10 Sq. mm Nos 14 Included 0.00 0 0
73.4 18 4C x 6 Sq. mm Nos 2 Included 0.00 0 0
73.5 18 4C x 4 Sq. mm Nos 14 Included 0.00 0 0
71 CONTROL CABLING 0 0
71.1 Supply & Laying ,testing and commissioning of control cum transmission wiring of Copper conductor shielded cable for looping between indoor & outdoor VRF system & to main Central remote controller system 0 0
71.2 18 3 C X 1.5 Sq. mm RMT 600 Included 0.00 0 0
J. SUB HEAD: CCTV SYSTEM 0 0
72 18 Supply, Installation, testing commisioning of Standalone IP CCTV System comprising of following: Infrared Dome Camera, 1/3" Interline Transfer CCD Sensor, Resolution of 600 TV Lines, 3.6 mm Lens, Automatically activates LED: below 10 lux, Radiant Distance Up to 20M, Power Input voltage - 12V DC Nos 4 Included 0.00 0 0
73 18 Supply, Installation, testing commisioning of Standalone IP CCTV System comprising of following: Bullet Camera Max 25 fps @ 5MP (16:9 Video Output) 120 dB true WDR, 3DNR, 24/7 colour imaging 60 m illumination distance CVI/CVBS/AHD/TVI switchable Built in Mic AutoFocus, 2.7 mm - 13.5mm Motorized Lense, Power Consumtion 11.88 w, 12 V DC. Nos 6 Included 0.00 0 0
74 18 Providing and laying flexible category 6 (CAT 6) cable for video transmission through the conduit (Including cost of conduit and its proper installation on ceiling/ wall etc.) Make D Link Mtr 650 Included 0.00 0 0
75 18 Medium Grade - 25 mm FRPVC Conduit with fitting ISI Marked with GI saddle & spacers at every 0.3 Mtr and Flexible conduits for all drops above false ceiling. Mtr 700 Included 0.00 0 0
76 18 20" colour, Flat Screen Type Professional CCTV Surveillance HD monitor 100-230 Vac 50 Hz.24x7 with wall mounted swivel stand Nos 1 Included 0.00 0 0
77 18 40" colour, Flat Screen Type Professional CCTV Surveiilance HD monitor of reputed make 100-230 VAC 50 Hz. 24x7 with wall mounted swivel stand Nos 1 Included 0.00 0 0
78 18 Redundant Power Supply with Input 230 VAC +/- 2V, load regulation & line regulation less than 0.1%, Electronic protection against overload & short circuit, output ripples less than 1 milli volt RMS5 Amps output Nos 1 Included 0.00 0 0
79 18 Network video Recorder with Monitoring, Viewing & Recording Software Embedded linux/Windows, MPEG4 compression LAN/TCP/IP, Networked Pentaplex operation Schedule/Motion/Alarm sensor recordings/ continuous server to server configuration Upto 8 Alarm input & 4 Relay output Alarm notification Via email Smart search, Post & pre alarm recording Water marking, PTZ control, password protection Minimum 1000 GB HDD, expandable with builtin DVD Writer (minimum 30 days storage) Upto 8 simultaneous views from different DVRS on same LAN on single screen Network bandwidth trottling from 128 Kbps to 19 Mbps 8 Channel - Display 200 fps, Recording 100 fps Nos 1 Included 0.00 0 0
80 18 Providing and laying flexible category HDMI Cable (including cost of conduit and its proper installation on ceiling/ wall etc.) Mtr 150 Included 0.00 0 0
K. SPRINKLER SYSTEMS 0 0
81 PIPES & ACCESSORIES 0 0
Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 0 0
81.1 18 25 mm dia M 300 Included 0.00 0 0
81.2 18 32 mm dia M 140 Included 0.00 0 0
81.3 18 40 mm dia M 50 Included 0.00 0 0
81.4 18 50 mm dia M 40 Included 0.00 0 0
81.5 18 65 mm dia M 55 Included 0.00 0 0
81.6 18 80 mm dia M 110 Included 0.00 0 0
81.7 18 100 mm dia M 30 Included 0.00 0 0
81.8 18 150 mm dia M 6 Included 0.00 0 0
82 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required : 0 0
82.1 18 Single headed Gunmetal Set 2 Included 0.00 0 0
83 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0 0
83.1 18 80 mm dia Set 2 Included 0.00 0 0
84 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 0 0
84.1 18 Gun Metal Set 2 Included 0.00 0 0
85 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 0 0
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 0 0
20 mm nominal internal dia gun metal globe valve & nozzle. 0 0
Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 0 0
85.1 18 30 m Set 2 Included 0.00 0 0
86 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 0 0
86.1 18 Gun metal Nos. 2 Included 0.00 0 0
87 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 0 0
87.1 18 Pendent Sprinkler Each 151 Included 0.00 0 0
87.2 18 Upright Sprinkler Each 95 Included 0.00 0 0
87.3 18 Horizontal side wall sprinkler Each 6 Included 0.00 0 0
88 18 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Each 2 Included 0.00 0 0
89 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 0 0
89.1 18 100mm dia Each 2 Included 0.00 0 0
90 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 0 0
90.1 18 80mm dia Set 2 Included 0.00 0 0
91 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 0 0
91.1 18 1000mm Set 50 Included 0.00 0 0
91.2 18 1200mm Set 40 Included 0.00 0 0
92 18 Providing and fixing of Fire Hose Cabinet size not less than 2.1 x 1.2 x 0.90 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including necessary locking arrangement and painting in PO red colour suitable to accommodate, internal hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man's axe. It shall be fixed inside the FHC Cabinet Complete as required . Each 2.00 Included 0.00 0 0
93 18 Providing and fixing standard firemans axe with heavy rubber handle. Each 2 Included 0.00 0 0
94 18 Providing and fixing Fire Extinguishers (CO2 type powder ) 4.5 Kg Capacity complete with all accessories as per manufacturers specifications. Each 15 Included 0.00 0 0
95 18 Providing and fixing Fire Extinguishers (A, B, C type powder ) 6 Kg Capacity complete with all accessories as per manufacturers specifications. Each 12 Included 0.00 0 0
L. FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) 0 0
INTELLIGENT FIRE ALARM SYSTEM 0 0
96 18 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. Each 2 Included 0.00 0 0
97 18 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Each 100 Included 0.00 0 0
Below the ceiling 0 0
98 18 Supplying, installation, testing & commissioning of Addressable 2 wire optical Multisensor (smoke cum heat) detector with built-in short circuit isolator, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity that can handle upto 5000 Lux, Discreet design for incorporation into any décor, Common mounting base, Drift compensation, detector sensitivity of 2.55+/- 0.33%/ft, Chamber monitoring by panel, option to connect remote indicator. Designed to meet UL268, 7th Edition. Nos. 100 Included 0.00 0 0
Above the ceiling 0 0
99 18 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Each 40 Included 0.00 0 0
100 18 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. Each 4 Included 0.00 0 0
101 18 Supplying, installation, testing & commissioning of fault isolator complete with base as required. Each 20 Included 0.00 0 0
102 18 Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. Each 12 Included 0.00 0 0
103 18 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Each 4 Included 0.00 0 0
104 18 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. Each 2 Included 0.00 0 0
105 18 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Each 2 Included 0.00 0 0
106 18 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. Each 1 Included 0.00 0 0
107 18 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Each 2 Included 0.00 0 0
PUBLIC ADDRESS SYSTEM 0 0
108 18 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. Each 2 Included 0.00 0 0
109 18 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. Each 18 Included 0.00 0 0
110 18 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. Each 4 Included 0.00 0 0
111 18 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. Each 1 Included 0.00 0 0
112 18 Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. Each 2 Included 0.00 0 0
CABLING & WIRING 0 0
113 18 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. Metre 350 Included 0.00 0 0
114 18 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. Metre 350 Included 0.00 0 0
115 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 0 0
115.1 18 speaker cable Two pair, 2-core, 1.5 sqmm Metre 180 Included 0.00 0 0
116 18 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. Metre 45 Included 0.00 0 0
117 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 0 0
117.1 18 20 mm Metre 190 Included 0.00 0 0
117.2 18 25 mm Metre 70 Included 0.00 0 0
117.3 18 32 mm Metre 50 Included 0.00 0 0
118 18 Providing and fixing of solar panel with solar inverter including distribution boxes having electrical equipments on roof/terrace on Galvanised steel structure as design KW 10.8 Included 0.00 0 0
Total Supply & Installation Charges 0.00 0
Total GST as confirmed by Bidder 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 3
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 4
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Training Charges for Training to be imparted
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Training Charges excluding GST Total Training Charges excluding GST Total GST as confirmed by Bidder
Revaluation of J column Tax Calculation
NOT APPLICABLE Revaluation of J column Tax Calculation
Included 0.00 0 0
Total Training Charges 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 4b
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Maintenance Charges during & after Defect Laibility Period
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Maintenance Charges excluding GST Total Maintenance Charges excluding GST Total GST as confirmed by Bidder
0 Revaluation of P column Tax Calculation
A. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
B. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
Total Maintenance Charges during and after Defect Liabilty Period 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 5
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON GOODS Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST on Civil & Electrical works (Supply Installation Services) (Schedule-3) 0.00 #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 5
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES 0.00
Total GST on Installation Services (Schedule-3), Training to be imparted in India (Schedule-4a) and Maintenance Charges during and after Defect Liabilty Period (Schedule-4b)
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 6
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Civil & Electrical works (Supply cum Installation Charges)
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule - 6 After Discount
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Civil & Electrical works (Supply cum Installation Charges)
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Schedule 7
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
SL. NO. PR No Line Item No Code HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total GST as confirmed by Bidder Revaluation of M column Tax Calculation Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
1 Included 0.00 0 0.00
2 Included 0.00 0 0.00
TOTAL TYPE TEST CHARGES 0.00
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
Bidder’s Name and Address (Sole Bidder) :
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-3 In Rs. 0.00 0.0000000000%
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-3 In Percent (%) 0.00 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : Ex-Works Price 0.0000000000%
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance 0.0000000000%
Schedule-3 : Civil & Electrical works ( S&I Charges) In Rs. 0.00 0.0000000000% Schedule-3 : Erection Charges 0.0000000000%
Schedule-4a : Training Charges In Rs. 0.00 0.0000000000% Schedule-4a : Training Charges 0.0000000000%
Schedule-4b : Maintenance Charges during and after DLP In Rs. 0.00 0.0000000000% Schedule-4b : Maintenance Charges 0.0000000000%
Schedule-7 : Type Test Charges In Rs. 0.00 0.0000000000% Schedule-7 : Type Test Charges 0.0000000000%
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-3 : Civil & Electrical works (S&I Charges) In Percent (%) 0.00 0.00%
Schedule-4a : Training Charges In Percent (%) 0.00 0.00%
Schedule-4b : Maintenance Charges during and after DLP In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00 0.00%
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566) Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Civil & Electrical works (S&I Charges). 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 4b Maintenance Charges during & after Defect Laibility Period.
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 1
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY 0 0.00
B) CENTRAL SALES TAX 0 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty % as Excise Duty
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. Statement of Quoted / Corrected Prices Page
Spec. No. Specification No.: NR1/NT/S-MISC/DOM/I00/24/07273 (Rfx: 5002003566)
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0 Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. 0 #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
Renovation of Ground Floor and Third Floor (Telecom Deptt) at POWERGRID Office, Katwaria Sarai. Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01-Section - I IFB SSTE Vol-I Civil.docx
docx • 0.05 MB
02 Section-II ITB SSTE Civil (Feb-19).pdf
pdf • 0.67 MB
03 Section - III_BDS Civil.docx
docx • 0.08 MB
04-Annexure-A (BDS)-QR.doc
doc • 0.05 MB
05-Annexure-B(BDS).docx
docx • 0.02 MB
06-Annexure-C(BDS).docx
docx • 0.03 MB
07-Section-IV GCC-Civil Works.pdf
pdf • 0.67 MB
08 Section - V SCC Civil Vol-I.docx
docx • 0.07 MB
09_Appendix-I to SCC.pdf
pdf • 0.35 MB
10_Appendix-II to SCC.pdf
pdf • 0.82 MB
11 Section-VI Forms and procedures.docx
docx • 0.12 MB
DRAWING_FENCING.pdf
pdf • 0.00 MB
DRAWING_OPEN YARD.pdf
pdf • 0.00 MB
Technical Specifications.pdf
pdf • 0.00 MB
DRAWING.pdf
pdf • 10.06 MB
DRAWING_FENCING_1.pdf
pdf • 0.00 MB
DRAWING_OPEN YARD_1.pdf
pdf • 0.00 MB
Technical Specifications_1.pdf
pdf • 0.00 MB
SAMPLE BOQ.xlsx
xlsx • 1.60 MB
SCOPE OF WORK.pdf
pdf • 0.13 MB
SFQP.pdf
pdf • 2.22 MB
TECHNICAL SPECIFICATION_CIVIL.pdf
pdf • 0.18 MB
TECHNICAL SPECIFICATION_ELECTRICAL.pdf
pdf • 0.09 MB
TECJNICAL SPECIFICATION_SOLAR.pdf
pdf • 0.25 MB
01 First Envelope Bid Forms.xls
xls • 1.54 MB
02 Legends for Units.pdf
pdf • 0.03 MB
03-Attachment-3-Bidder Eligibility.doc
doc • 0.04 MB
04 Attachment-18_SAFETY PACT.pdf
pdf • 0.36 MB
05-Attachment 14 INTEGRITY PACT.pdf
pdf • 0.20 MB
06 Attachment-20 KMP Declaration Format.doc
doc • 0.06 MB
07 Attachment 21-Affidavit for correctness of information.docx
docx • 0.02 MB
08 Attachemnt-22_Declaration regarding events encountered.docx
docx • 0.03 MB
09 Attachment 23- Certification by the Bidder as per DoE order in line with ITB 2-1.docx
docx • 0.02 MB
10 Attachment-24_Affidavit for self-certification regarding Minimum Local Content.DOCX
docx • 0.02 MB
11_Attachment-25-Compliance to the process related to the e-RA.docx
docx • 0.02 MB
12_Checklist.xlsx
xlsx • 0.01 MB
Price_Schedule.xlsx
xlsx • 1.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .