| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹39.9 L+₹1.9 L (5.03%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.1 L+₹3.1 L (8.16%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Being not belongs to appropriate category |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Aug 2023, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
REPAIR MAINT OF INTERNAL WIRING, FAN AND ALLIED WORKS IN NP AREA AND EARTHING AT AF STATION GORAKHPUR
2023_MES_600016_2
9048/E8
Open Tender
Civil Works
Item Rate
330 days
GE(AF) GORAKHPUR
Class D Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹80,000
Yes
25 Oct 2023
21 Jul 2023
16 Aug 2023
21 Jul 2023
14 Aug 2023
2 Aug 2023
21 Jul 2023 - 27 Jul 2023
Amount
S&F in replacement copper electrode chemical earthing with high conductive, corrosion resistant, CPRI Tested and CE Certified maintenance free chemical earthing pit (pipe in pipe technology Based) in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondary conductor and between secondary and primary conductor of earthing electrode crystalline compound is to be injected. The length of this electrodes is min 3000 MM (3 meters) having 45 Kg of ground enhancement compound. It contain a homogenous mixture of conductive cement, electrolyte corbon, Hydrous alluminium cilicate and other electrolyte compound complete and 60 Kg contain a homogenous mixture of conductive cement, Coal powder, electrolyte corbon, Hydrous alluminium cilicate and other electrolyte compound. Filled in earth pit of bore hole of 200 to 250 MM dia and depth upto 6.15 meters min length of electrode will be increase with connecting of 32 x 6 mm copper strip extra up to 3.5 meters, and total depth of earthing electrodes in min 6.15 meters for achieve resistance valve less than or equal to 1.0 Ohm including RCC earthing pit cover having 450 x 450 CI chamber cover all as directed. Note: (a) If less than 1.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate).
M&L for replacement earthing complete with Copper plate 600x600x3.15mm thick electrode & 20x3 mm copper strip as earthing lead buried directly in ground (earth pit not less than 3.0 mtr deep below ground level) with top edged of the plate not less than 2.40 mtr below normal ground level, connected to copper earth lead by means of bolt, nut, check nut and washer of copper strip of size 20X3.15mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated and testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggregate, funnel, 20mm dia GI med grade water pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not exceeding 50m, complete testing on completion all complete as shown in electrical plate No. 4 of SSR part No1 all as directed. Note: (a) If less than 2.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate).
M&L for replacement earthing complete with galvanized steel earth plate electrode 600mm X600mmX6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth strip 32x6 mm, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 6 mm dia MS bars both ways complete all as specified & directed. Note:(a) If less than 5.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate.
Supply and spreading in layers Magnesium Sulphate (MgSO4 crystal) for repair to existing earthing pit complete all as specified and directed.
M&L for brazing of earthing strips (GI/Copper/Aluminium) by arc/gas welding approx 50mm long tapper joint complete all as specified and directed.
M&L for replacement of bolts stainless steel of size 1/4"x1" with nuts & washer (01 each) complete all as specified and directed.
M&L in replacement for construction of earth pit chamber of internal dimensions of 300x300x250mm in brick masonry built in PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC cover slab (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia- 2.0mtr long with funnel and wire mesh including taking out and dismantle of unserviceable earth pits complete all as specified and directed.
S&F in replacement pre cast RCC cover slab (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle for earth pit chamber of internal dimensions of 300x300x250mm complete all as specified and directed
S&F in replacement earth continuity conductor or main earthing lead 50mmx6mm copper strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 32mmx6mm copper strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 20mmx3mm copper strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 32mmx6mm GI strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned GI nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed.
S&F in replacement aluminium strip of size 25x3.15 mm complete with saddle, porcelain insulator and fixing screws, washer/accessories for roof and down conductor complete all as specified and directed.
S&F in replacement Air termination, single pointed copper rod 12mm dia and 300mm long fixed/ tightened properly at directed location/ height complete all as specified and directed.
Labour only for dismantling of unserviceable and abandoned earth pits (above ground) and level the surface up to existing ground level complete all as specified and directed.
Boring of holes horizontally for laying of upto 25mm dia pipe (minimum depth 600mm from top level) under road, Pavement, hard standing complete all as specified and directed.
M&L for making PCC foundation of size 30x30x40cm depth (for support of watering pipe as well as lightning spikes as reqd) with cement concrete of ratio 1:3:6 type B-1 using 20 mm graded stone aggregate including plastering in CM 1:4, two coat white washing of masonary surface complete all as specified and directed.
M&L for cutting and threading of existing GI pipe of dia upto 25mm for branch connection including provisioning / insertion of 01 No Tee GI of 15 or 20mm dia outgoing complete all as specified and directed.
S&F galvanised steel water tubes medium grade 15mm dia including all fittings and connection fixed to wall or under the floor complete all as specified and as directed.
S&F galvanised steel water tubes medium grade 20mm dia including all fittings and connection fixed to wall or under the floor complete all as specified and as directed.
S&F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipes 15 mm dia (Minimum weight 90 gms) complete all as specified and directed.
M&L for making computerised made PVC sticker as per existing shape/size not exceeding 200mmx300mm width and writing following details in Capital letters form of 25mm height and 10mm width on single side of the sticker in black colour with red or yellow colour back ground as required at site complete shall be paste properly and make to shape as per size of existing MS board complete all as specified and directed with following:- (a) Type of earthing-GI or Copper or Chemical (b) Earthing for which equipment is being connected (e.g. lightning arrester) (c) Number of earth pit and the total number of particular type of earthing for that Bldg/Equipment (e.g. Number-01 Lightning Arrester pit out of 04 Nos pit of same- "LA-01/04")
S&F in repair High density polyethylene pipes (HDPE) of size 40mm dia laid in trenches as well as fixed to wall with provisioning of suitable sizes of MS clamps (1 mtr apart), screws etc for passing of lightning arrester strips complete all as specified and directed.
S&F in replacment porcelain insulators for fixing roof/down conductor including fixing of screws etc as specifed and directed.
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed for following :- (A) One Light/fan point controlled by one switch
(B) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(C) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(D) One bell point controlled by one 5 Amps bell push.
(E) One light point controlled by two 5 Amps two way switch.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 2 to 7 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
M&L for point wiring controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed FOR THE FOLLOWING POINTS:- (A) One Light/fan point controlled by one switch
(b) One 5 Amps socket point controlled by one 5 Amps switch on same board.
(c) One 5 Amps socket point controlled by one 5 Amps switch on independent board.
(d) One bell point controlled by one 5 Amps bell push.
(e) One light point controlled by two 5 Amps two way switch.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 8 to 12 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 5/6 amp, single pole, two way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Wipro/CG/ Bajaj / CG.
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865SPCWH or equivalent in Bajaj / CG.
S&F recess mounting LED luminaire of size 2'x2' white 34 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Make:- Wipro/CG/ Bajaj / CG..
S&F rechargeable 6 W LED light with frosted PC cover and pull cord complete all as specified and directed.
S&F recess mounting LED luminaire round shape 12 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Make:- Wipro/CG/ Bajaj / CG./Philips
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 25 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Wipro/CG/ Bajaj / CG./Philips
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Make:- Wipro/CG/ Bajaj / CG./Philips
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 70 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Make:- Wipro/CG/ Bajaj / CG./Philips
S&F post top lantern light fitting 25W LED made in die cast aluminium housing with decorative opal acrylic diffuser and IP65 protection, fixed properly at directed location complete all as specified and directed. Make:- Make:- Wipro/CG/ Bajaj / CG./Philips
S&F LED light fitting 1x13.5W LED(wall/Ceiling mounted) with PIR Sensor for automatic operation, switches on automatically in human presence within 5m range powered by in built electronic driver in PC housing with SMPS based constant currnety supply, output short circuit protection and surge voltage protection complete all as specified and directed Make: Philips, CAT No ELLIPSE NEO 13.5W PIR HEXA or equivalent iin Bajaj/Philips/CG/ WIPRO
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Boring of holes horizontally for laying of 40 mm dia pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
S&F 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Supply & fix in repairs , laying and testing 6 Sqmm, 2.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
S&F in replacement brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed.
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 4.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connections of 6 Sqmm size twin core flat solid conductor cable complete from pole to distribution board main controlling switch complete all as specified and as directed.
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F sheet metal enclosure distribution board SPN 2 ways complete all as specified and directed.
S&F MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TP, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F in repairs sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F in replacement U/S and broken exhaust fan (air freshener) single phase 230/240 volt AC 300mm sweep with louvers, plastic body with twisted copper flexible wire 23/0.0076mm including taking down old fan and deposited in MES store complete all as specified and directed.Make: Havells/Bajaj/CG.
S&F in replacement unsv wall mounted fan single phase 230/240 volt AC 400mm sweep, with regulator, oscillation type complete fixed properly on wall and connecting /testing as directed. Note Old unsv fan will be deposited to E/M store yard. Make: Havells/Bajaj/CG.
Repairing of light point (normal/ flameproof), fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type, lamp any type, MCB DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected minor accessories by providing sufficient and skilled manpower. Work shall also include to check & removal of current leakages in Bldgs and any urgent nature of work as and when directed. The scope also include cutting of existing Bakelite sheet to accommodate new elect fittings/fixtures like switches, sockets, fan regulators etc. Note :- (a) The rate quoted by the contractor for Each Job is deemed to be included consisting of minimum 03 complaints in working hours between 0900 AM to 0500 PM in NP area by engaging one electrician and one helper. (b) The contractor or his representative will take complaint from MES complaint Register through MES job card. (c) The contractor will made separate items register with location and signature of user. (d) The contractor will maintain complete details of Job cards (Working/Off working hours) and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor. (f) Risk factor & security pass will be the contractor's end. (g) Material will be measured and paid separately in the relevant item here after. (h) All supply material shall be deposited by contractor in MES store yard and issued in every Job Card as per requirement. (j) The tradesmen should be available at MES area complaint cell (In MES Complex), after completing their daily Job Cards as well as during off working hours / Night / Sunday / Holiday.
All as per Item No. 91 above but for attending the electrical complaints during off working hours / Night / Sunday / Holiday time for 12 hours. Note :- All as per item No 91 above but the rate quoted by the contractor for 'Each Job' is deemed to be included 01 complaint in NP area
Supply only fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
Supply only switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
Supply only modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
Supply only modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
Supply only modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
Supply only modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
Supply only modular bell push pole 1 way, 1 module, 6 Amp complete all as specified and directed.
Supply only switch socket combination multipurpose 5 pin 5/15 Amps
Supply only switch socket combination multipurpose 5 pin 5 Amps
Supply only switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed.
Supply only socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed.
Supply only socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
Supply only bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
Supply onlyceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
Supply only Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
Supply only lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply only in replacement lamp LED 9/12 watt, 240 volts complete all as specified and directed.
Supply only tape insulation, 1100 volts grade 20mm width, 15 mtrs long complete all as specified and directed.
Supply only in replacement ball bearing No. 6200 to 6203 complete all as specified and directed.Make:-SKF/NRB/NBC/TATA
Supply only in replacement gun metal bush of any description and size to suit existing motor shaft complete all as specified and directed.
Supply only in replacement capacitor of capacity 2.5 mfd PVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA
Supply only in replacement capacitor of capacity 3.15 mfd PVC body complete all as specified and directed. Make:- EPCOS/ JYOTI/ USHA
Supply only wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed.
Disconnecting, taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, air circulating fans and pedestal fans etc. of any description, any sweep and from any position/locations for repairs/servicing/numbering, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The replacement of defective/ nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item here-in-after. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.
Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal
All as per item No. 117 above but rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire.
All as per item No. 117 above but rewinding of motor of exhaust fans of 300/400 mm sweep with 200 gram winding wire.
All as per item No. 117 above but rewinding of motor of air circulating fan of 400 mm sweep with 300 gram winding wire.
All as per item No. 117 above but rewinding of motor of pedestal fan of 400 mm sweep with 400 gram winding wire.
Supply only in replacement complete fan hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
Supply only PVC Casing caping of size 25mmx16mm complete all as specified and directed
Supply only modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amps capacity complete all as specified and directed.
Supply only SS Screws of dia 6mm with long plug shaft for fixing of casing caping complete all as specified and directed
Supply only fastener bolts for fixing of geysers complete all as specified and directed
Supply only in replacment single core 1.5sqmm copper cable Heat Resistant Flame Retardant (HRFR) PVC Insulated Industrial flexible cable 1100 volts complete all as specifeid and directed.
Supply only in replacment single core 2.5sqmm copper cable Heat Resistant Flame Retardant (HRFR) PVC Insulated Industrial flexible cable 1100 volts complete all as specifeid and directed.
Supply only in replacement 3 core PVC insulated and FR PVC Round Sheathed, Copper Conductor 2.50sqmm each core, 1100 volts grade complete all as specified and directed.
Supply only in replacment motor, single phase for 200/250mm Exhaust fan as per sample complete all as specified and directed.
Supply only in replacement Switch Socket combination unit with box having 20A Switch, 6A/16A Socket, 240 volts complete all as specified and directed.
S&F in replacement Mi boxes with hinged transparent lid of size 315 x 315 x 170mm for housing of meters of Hensel Make Cat No. Mi 9200 complete all as specified and directed.
M/s A.K Construction
Yaduvanshi Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .