Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹27.2 L+₹1.4 L (5.52%)Rejected-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹28.5 L+₹2.7 L (10.5%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹31.0 L+₹5.2 L (20.1%)Rejected-AOC | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹33.8 L+₹8.0 L (31.0%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Feb 2020, 6:00 pmClosed
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION ELECTRICAL FITTINGS FIXTURE AT DK-I DK-II AND ADJOINING AREA UNDER GE (C) DELHI CANTT10
2020_MES_321736_1
GE/C-54/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Ceentral) Delhi Cantt
₹80,000
Yes
14 Jul 2020
4 Feb 2020
26 Feb 2020
4 Feb 2020
24 Feb 2020
19 Feb 2020
4 Feb 2020 - 19 Feb 2020
Amount
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete excluding fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc and shall be measured separately and making good disturbed surfaces of walls, floors etc complete all specified and direc ted by Engineer-in-Charge.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit incl new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for the follwing point controlled by one No one way switch all as specified and directed by Engr-in-Charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
ne 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per above item No 2 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all specified and direc ted by Engineer-in-Charge.
All as per above item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4.0 Sqmm single core stranded copper cable for one AC/geyser point on independent board complete all specified and direc ted by Engineer-in-Charge..
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in new PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one follwing point controlled by one No one way switch all as specified and directed by Engr-in-Charge.
One light/Exh fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 5 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all specified and direc ted by Engineer-in-Charge..
All as per item No 5 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4.0 Sqmm single core stranded copper cable for one AC/geyser point on independent board complete all specified and direc ted by Engineer-in-Charge Note (i) PVC conduit shall be Medium grade, ISI marked. Make:- " Polycab, AKG and Finolex" (ii) PVC Cable Make:- "RR Kable, Havells & polycab" Note : Make of wire:- "RR Kable, Havells & polycab"
M&L for point wiring with 2 single core PVC insulated, unsheathed stranded copper conductor of size 1.5 sqmm and including 1 single core of size 1.5 Sqmm as Earth continuty conductor and PVC casing/caping 20mm dia medium grade and PVC board for mounting switches/socket combination all as directed and specified by Engr-in-Charge :- Note:- (i) PVC casing/caping shall be Medium grade, ISI marked. Make:- " Polycab, Kalinga Premium and AKG" (ii) PVC Cable Make:- "RR Kable, Havells & polycab"
One light point or one fan point or bell point controlled by one switch SP, one way, 230 volts.
One 3 pin socket outlet 5 Amps on independent board
One power point with pre insulated unsheathed standerd copper conductor cable & 2.5 sqmm single core (FRLS) and pre unsheathed copper conductor 2.5 sqmm single core on earth wire connected to earth doly complete..
M&L in replacement of switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement of Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement of switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge. ISI marked Make:- Legrand/Havells/ ABB
M&L in replacement of Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement of Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement of switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
All as item 15 here-in-before but single pole 6 Amps two way complete all as specified and directed by Engineer in charge.Make:- Legrand/Havells/ ABB
M&L bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement socket outlet 6 Amp flush button type acomplete all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. Make:- Legrand/Havells/ ABB
M&L in replacement regulator electronic socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. Make : Havells Reo or equivalent in legrand/Schneider/Polycab .
M&L in replacement bell electric (dingdong) 230 volt, SP complete all as specified and directed by Engineer in charge. Make : Havells Reo/ legrand/Schneider/Polycab .
M&L in replacement Buzzer, AC, 230 Volts, single pole, all as specified and directed. Make : Havells / Crompton Greaves/ Bajaj.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed. Make : Havells / Crompton Greaves/ Bajaj.
S&F ceiling rose surface PVC 65x50 mm type with three terminals complete all as specified and directed by Engineer in charge. Make:- Havells/Polycab/Anchor.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge. Make:- Legrand/Havells/ ABB
M&L in replacement white cover plate with frame 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10 A capacity all as specified and directed. Make:- Legrand /siemens/ABB.
All as per item no 32 but with single pole MCB 'C' series 20 Amps complete all as specified and directed by Engineer in charge. Make:- Legrand /siemens/ABB.
Supply and fix LED in replacement of batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CG
Supply and fix in replacement of LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light) Make:- Philips/Wipro/Jaquar/CG
Supply and fix in replacement of LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/cG
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge. Make:- Philips/Wipro/Jaquar/CG
Supply and Fixing in replacement of LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base. Make:- Philips/Wipro/Jaquar
Supply and fix in replacement of LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CG
Supply and fix in replacement of surface ceiling mounted down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. Make:- Philips/Wipro/Jaquar/CG
Supply and Fixing in replacement of LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base. Make:- Philips/Wipro/Jaquar
Supply and Fix in replacement of 40W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed. Make:- Philips/Wipro/Jaquar/CG
S & F electronic driver with high voltage protection upto 380 Volt AC suitable for LED recessed mount 2"x2", 36/40 watt including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge. Make:as per sample
S & F electronic driver with high voltage protection upto 380 Volt ACdriver suitable for LED surface mounted 12/15 watt ceiling light including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge. Make:as per sample
S & F electronic driver with high voltage protection upto 380 Volt AC suitable for LED building security light, 30 watt including connecting complete with connected accessories at given site complete all as specified and directed by engr-in-charge. Make:as per sample
Supply and fix in replacement of MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. Make:- Legrand/SEIMENS/ABB. /BALENO
Supply and fix in replacement of MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. Make:- Legrand/SEIMENS/ABB./BALENO
Supply and fix MCB DB SPN 2 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. Make:- Legrand/SEIMENS/ABB./BALENO
Supply and fix in replacement of MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. .Make:- Legrand/SEIMENS/ABB. /BALENO
Supply and fix in replacement of MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. .Make:- Legrand/SEIMENS/ABB./BALENO
Supply and fix in replacement of MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. Make:- Legrand/SEIMENS/ABB/BALENO.
Supply and fix in replacement of MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. Make:- Legrand/SEIMENS/ABB/BALENO.
Supply and fix in replacement of MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. Make:- Legrand/SEIMENS/ABB./BALENO
Supply and fix in replacement of MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. Make:- Legrand/SEIMENS/ ABB./BALENO
S & F exhaust fan 230 mm sweep in replacement against BER in BOO metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site complete all as specified and directed by Engineer in charge. Make : Orient /Bajaj/Havells
Supply and fixing Ventilating Fan 230 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmmincluding writing MES NO. 2 CM height with synthetic enamelled black paint complete all as specified and as directed Make : Orient /Bajaj/Havells
Supply and fix in replacement of Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Make : RR Kable, Havells & polycab Note: Three runs of 6 sqmm cable shall be measured as one RM.
Supply and fix in replacement of Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Make : RR Kable, Havells & polycab Note: Three runs of 10 sqmm cable shall be measured as one RM.
S&F in repair Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. Make for wiring cable :-RR KABLE/Finolex/Havells/Polycab. Note:- PVC rigid conduit ISI marked FRLS Grade Make: POLYCAB/AKG/BAJAJ Three runs of 6 sqmm cable and one run of pvc conduit shall be measured as one RM.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
S&F in relacement plug top 16 Amps 3 pin 230- volts complete all as specified and directed by Engineer in charge. Make:- Havells /Reo/Polycab.
S&F in replacement plug top 6 Amps 3 pin 230- volts complete all as specified and directed by Engineer in charge. Make:- Havells /Havells Reo/Polycab.
S & F PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) . Make- Legrand /Havells/Crabtree/Polycab.
S & F PVC Gang box surface type heavy duty suitable for single 5 Amps switch & socket (ISI Marked) Make- Legrand /Havells/Crabtree/Polycab.
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked) Make- Legrand or equivalent in Havells/Crabtree/Polycab.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
Sheet 4" x 4" single cutting suitable for one piano switch
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. Make: RR cable/HavellsH/Polycab
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. Make: RR cable/HavellsH/Polycab
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.Make: RR cable/HavellsH/Polycab
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.Make: RR cable/HavellsH/Polycab
M&L in replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. Make: RR cable/HavellsH/Polycab.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge. Make: RR cable/Havells/Polycab
M & L in replacement for only twin core PVC insulated unarmoured cable 10 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor and drawing in existing concealed conduits, hanging or suspended over GI wire 2 mm dia and binding with real minsulators not more than 2 mtr space complete all as specified and directed by Engr-in-Charge. Make:- " RR KABLE/POLYCAB/ HAVELLS".
M & L in replacement for only twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor and drawing in existing concealed conduits, hanging or suspended over GI wire 2 mm dia and binding with real minsulators not more than 2 mtr space complete all as specified and directed by Engr-in-Charge. Make:- " RR KABLE/POLYCAB/ HAVELLS".
S & F hole fastner madeup of MS 6" long with complete nut boltcomplete all as specified and directed by Engineer in charge. Make:as per sample
S & F hole fastner madeup of MS 4" long with complete nut bolt complete all as specified and directed by Engineer in charge. .Make:as per sample
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 32/40mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including MS clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge . Make:As per sample
Refixing of Ceiling fan / exhaust fan/ fresh air/ Wall mounted fan after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only.
Refixing carefully geysers 25/50 ltrs capacity opening for inspection reassembling in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
Taking down carefully old unserviceable heating element, thermostat, connection pipe, NRV, Pressure valve plug top and socket from geyger of any storage capacity and make complete all as specified and directed.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan to the entire satisfaction of Engr-in-Charge.
All as per item No81 above but 1400mm sweep complete. Testing of the ceiling fan to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of Exhaust fan 225/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan to the entire satisfaction of Engr-in-Charge.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed by Engineer in charge.
M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engineer in charge.
Supply & fixing Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement as per existing complete all as specified and directed by Engineer in charge.
Supply & fixing Ceiling fan blade suitable for 1400mm sweep of any make with suitable size as per site requirement as per existingcomplete all as specified and directed.
Supply & fixing exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed.
Supply & fixing PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per existing sample approved .
Taking down old unserviceable down rod and supply and fix 60 cm long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed.
S&F in replacement capacitor of 2.5 MFD, complete all as specified and directed by Engineer in charge. Make :Orient/Epcos/Havells.
S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer in charge. Make : Orient/Epcos/Havells.
Supply & fixing ball bearing No. 6202, complete all as specified and directed by Engineer in charge. Make: SKF/NBC/TATA
Supply & fixing ball bearing No. 6203, Make: complete all as specified and directed by Engineer in charge. SKF/NBC/TATA
Supply & fixing gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm complete all as specified and directed by Engineer in charge.
Supply & fixing worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed.
M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed. Make - Havells / Jaquar / Bajaj.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed. Make - Havells / Jaquar / Bajaj.
S&F heating element of 2 KW triangular type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
S&F heating element of 2 KW circular type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
S&F heating element of 1.5 KW triangular type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
S&F of thermostat for 25/50 ltrs capacity of geysers complete all as directed.
M & L neon lamp/indicator lamp for geysers complete all as directed.
M&L for soldering and brazing inner copper tank 25/50 ltrs with brass solder and refixing complete .
Supply & fixing base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed.
Supply & fixing inner copper tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed
Supply & fixing outer body/cover suitable for 25 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body including two coat of white synthetic enamel paint over one coat of red oxide (spray painting) all asdirected by Engineer-in-charge.
Supply & fixing top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade complete all as specified and directed by Engineer in charge.
Supply & fixing bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces.
Supply & fixing Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply alongwith 1 MFD capacitor and cap suitable for 250/200 mm size Fresh air fan as per sample complete all as spd and directed.
S&F plug top, 3 pin, 10/20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F socket 3 pin 10/20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
Supply & fixing exhaust fan motor capacity 1/4 HP 230 volts suitable for 230 mm size exhaust fan complete all as directed.
Supply & fixing PVC fresh air fan blade suitable for 250/200 mm size with all fixing accessories complete all as spd and directed.
S&F in replacement factory made epoxy powder coated switch disconnector fuse unit TPN with sheet metal enclosure confirming to IS 60947-3, 100Amps, positive isolation suitable for DIN & Bolted HRC fuse links fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts complete all as specified and directed by Engineer in charge. .
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system against declared BER by BOO complete all as specified and directed by Engineer in charge.
S&Fin replacement factory made epoxy powder coated switch disconnector fuse unit TPN with sheet metal enclosure confirming to IS 60947-3, 200Amps, positive isolation suitable for DIN & Bolted HRC fuse links fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts complete all as specified and directed by Engineer in charge. .
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. complete all as specified and directed by Engineer in charge. Make:- Legrand/ IndoAsian/Havells/BANELO
Note :- Total amount of Sch of credit is Rs 159419.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S Sunil Steel Works
M/S ANIL KUMAR
Pall Associates
SANJEEV ENTERPRISES
LAMBA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .